1 Area of application
Pressure gauges to this standard are used to measure pressures in hydraulic systems.
2 Dimensions
Housing ∅ 63 Housing ∅ 100
48
8
32
6.5
100
o107
o68
62
15.5
87 +1
13
54 +1
SW14 SW22
20
5
3
13
o5 o6
G1/4A G1/2A
3 Type code
Example Manometer AB 31-11 / 063 - 060 bar/psi
AB standard
Housing
63 = 063
100 = 100
Measurement range
(see selection tables, table 1 - 3)
Design
Single scale = no code
Dual scale with pressure range bar and psi = bar/psi
Dual scale with pressure range bar and mpa = bar/mpa
Options
No options = no code
Red marker on pressure gauge face 1) e.g. at 200 bar = RM 200
Medium
Standard = no code
Low temperature version silicone filled = MT
Note:
Pressure gauge with red marker, power unit department assembly Pos. 9.
5 Selection tables
5.1 Pressure gauge with single scale, indication range bar
Table 1
Measurement Housing ∅ 63 Housing ∅ 100
range Designation: Manometer AB 31-11/...
bar Material no. Material no.
10 063- 010 R900061944 100- 010 R900067161
16 063- 016 R900020605 100- 016 R900067162
25 063- 025 R900002680 100- 025 R900027991
40 063- 040 R900002681 100- 040 R900027992
60 063- 060 R900002682 100- 060 R900008343
100 063- 100 R900002683 100- 100 R900006489
160 063- 160 R900002684 100- 160 R900005961
250 063- 250 R900002685 100- 250 R900005962
400 063- 400 R900002686 100- 400 R900005963
600 063- 600 R900061432 100- 600 R900006955
1000 063-1000 R900067156 100-1000 R900211528
″Copyright reserved″
Page 3 / 4
Glycerine filled pressure gauge AB-E 31-11 : 2002-11-08
6 Suitability
Table 4
Pressure fluids NG 63 NG 100
Mineral oil HLP to DIN 51524
Water emulsion HFC
Phosphate ester HFD-R to VDMA 24317
Organic ester HFD-U suitable
Polyglycole based synthetic fluids HEPG
Vegetable oil based hydraulic fluids HETG to VDMA 24568
Ester based synthetic fluids HEES
″Copyright reserved″
Page 4 / 4
AB-E 31-11 : 2002-11-08 Glycerine filled pressure gauge
7 Technical data
Table 5
NG 63 NG 100
Build form
Caution:
For temperatures from -40 °C to +60 °C the gauges must be silicon filled.
8 Assembly guidelines
When fitting a test hose to the pressure gauge connection piece a counter spanner should be used on the
pressure gauge.
″Copyright reserved″