You are on page 1of 1

DPWH - BRS

CIVIL ENGINEERING LABORATORY ACCREDITED LABORATORY


DOOR 3 & 8 NEOTRINITY BUILDING, VALID UNTIL : 12 - 22 -2021
HIGHWAY, KAUSWAGAN, CDO CITY
Page
CELLPHONE NO.: : 09178214796 1 of 1
Date : May 04, 2020
Laboratory No. : AMTL - 2003 - 3003
DETERMINATION OF CHEMICAL AND PHYSICAL PROPERTIES OF PORTLAND CEMENT
18KO0122: Road Widening along Butuan City - Cagayan de Oro City - Iligan
Project Name :
City Road K1417+067 - K1417+362, K1417+004 - K1417+890
Contractor : Legacy Construction Corporation
Matl's Description : Cement Type I Sample Identification : CMT-311,405-Q1
ASTM C114,C184, C151,
Quantity Represented : 10,000 bags Spec's Item No. : C188, C191 & C109
Holcim Phils. Inc.,
Proposed Used : PCCP / Structural Concrete Original Source :
Lugait, Mis. Or.
Holcim Phils. Inc.,
Sampled At : Project site Owner / Supplier :
Lugait, Mis. Or.
Melvin Padillos/ William G.
Sampled By : Legacy Const. Corp./ DPWH X 03-27-2020
Galgo - QC/MLT
(Name & Designation) (Office) (Date)

Submitted By : Rosemarie B. Gamos - ME DPWH X 03-30-2020


(Name & Designation) (Office) (Date)
R.P. Estrella/ R.B. Mencede- 04-03-2020 to
Tested By : RCh/MLT
Allied Material Testing Lab.
05-01-2020
(Name & Designation) (Office) (Date)

CHEMICAL ANALYSIS TO ASTM C114


REQUIREMENTS ASTM C150
CHEMICAL MEASURAND/ COMPONENT RESULTS REMARKS
(Table 1)
Calcium Oxide (CaO), % 61.3
Magnesium Oxide (MgO), % 1.07 6.0 max Complies
Sulfur Trioxide (SO3), % 2.15 3.5 max Complies
Loss on Ignition, % 2.42 3.0 max Complies
Insoluble Residue, % 0.70 0.75 max Complies
PHYSICAL ANALYSIS TO ASTM C184, C151, C188, C191, C109
REQUIREMENT
PHYSICAL MEASURAND/ COMPONENT TEST METHOD RESULTS REMARKS
ASTM C150 (Table 3)
Fineness, % ASTM C184 98.50
Autoclave expansion, % ASTM C151 0.05 0.80 MAX Complies
Specific Gravity ASTM C188 3.11
Time of Setting, Vicat Test ASTM C191
Time of Setting, Initial 94.0 minutes MIN. 45 MINUTES Complies
Time of Setting, Final 187.0 minutes MAX. 375 MINUTES Complies
Compressive Strength, Mpa ASTM C109/C109M
Mortar cubes strength (Avg.), Mpa
3 days 16.40 MIN. 12 MPa Complies
7 days 25.60 MIN. 19 MPa Complies
28 days 33.60 MIN. 28 MPa Complies
Test Witnessed By: Prepared By :

ROCHELLE P. ESTRELLA
MELVIN PADILLOS Laboratory Analyst / Chemist - PRC#0014821
Quality Control Allied Material Testing Laboratories
Legacy Construction Corporation
Checked & Attested By :

ROSEMARIE B. GAMOS
Material Engineer CRISTY B. CERBAS
DPWH X Laboratory Head / Material Engineer II
Allied Material Testing Laboratories

This Laboratory is responsible for test only. Results were carried out based on samples submitted to Allied Material Testing