Problem Mode Level machine


Machine / Cost_Ctr. PM 8 Area ; Location PM-1st Floor
Notif_st chest
Feb 17, 22
(from - to) (from - to)

Problem Description
Buburan di machine chest habis
Clarification / Control valve tutup bersamaan dengan control valve dilution starch tutup juga
Turbo 1 trip
Problem
Phenomena (What,
When, Where, On reel ada putus lagi di 1D, white water consistency belum stabil
Which, How ) Speed turun 1206 Efek
Root Cause Analysis ( WWA, etc. ) Activity Req. End Date
Pers. Respon sible / PIC
Problem Mode Notif_st (1st Lv.Sub-bone) [ Restoration, Prevention ] / Deadline

1 Kenapa pick up rise dan stock bubur?

Karena pompa machine chest mati

2 Kenapa pompa machine chest mati?

Karena level machine chest habis

3 Kenapa level machine chest habis?

Karena buburan dipompa ke silo, tapi tidak


mendapat supply dari mixing chest

4 Kenapa buburan dipompa ke silo, tapi tidak


mendapat supply dari mixing chest

Karena pompa mixing chest stop alarm


thermal relay

5 Kenapa pompa mixing chest stop alarm


thermal relay

P: Ubah parameter program jadi bila motor


I/O sudah function reduction benar-benar trip, baru kasih indikasi thermal Haryadi A. 18-Feb-22
relay di DCS
Doc.No./ Ref. Prepared by Acknowledged by
Manager
RCA/22/02/02 [ Signature & La Ode G. [ Signature & Jarwono
Name ] Name ]
Losses
01:04-02:14 70 min
(type - qty)

eq. End Date


Status & Notes
/ Deadline

18-Feb-22 Close