You are on page 1of 1

ELECTRICAL NOTES

1. ALL ELECTRICAL NOTES SHALL COMPLY WITH THESE PLANS AND


SPECIFICATIONS. THE APPLICABLE PROVISIONS OF THE LATEST
LOADSCHEDULE EDITION OF THE PHILIPPINES ELECTRICAL CODE (PEC), THE
RULES AND REGULATIONS OF THE LOCAL ENFORCING
OVER CURRENT PROTECTION AUTHORITY, AND THE REQUIREMENTS OF THE LOCAL POWER
CKT NO. LOAD DESCRIPTION WATTAGE VOLT A NO., SIZE & TYPE OF WIRE CONDUIT SIZE COMPANY.
AF P AT

1 LIGHT OUTLET, 3 -- 100W 300 230 1.30 50 2 20 2 -- 3.50 mm2 THWN 20mm Ø RSC
2. THE ELECTRICAL SERVICE POWER SHALL BE 1-PHASE, 3-WIRE,
230V AC, 60Hz.
2 LIGHT OUTLET, 3 -- 100W 300 230 1.30 50 2 20 2 -- 3.50 mm2 THWN 20mm Ø RSC
3. THE WIRING METHOD SHALL BE AS FOLLOWS:
3 LIGHT OUTLET, 4 -- 100W 400 230 1.40 50 2 20 2 -- 3.50 mm2 THWN 20mm Ø RSC RIGID STEEL CONDUIT (RSC) OR POLYVINYL CHLORIDE CONDUIT (PVC)
SCHEDULE 40 SHALL BE USED AS SPECIFIED IN THE PLAN.
4 LIGHT OUTLET, 3 -- 100W 300 230 1.30 50 2 20 2 -- 3.50 mm2 THWN 20mm Ø RSC

LIGHT OUTLET, 3 -- 100W


4. ALL WIRES SHALL BE COPPER AND THERMOPLASTIC INSULATED
5 300 230 1.30 50 2 20 2 -- 3.50 mm2 THWN 20mm Ø RSC
TYPE "THHN" UNLESS OTHERWISE INDICATED IN THE PLAN. THE
6 LIGHT OUTLET, 3 -- 100W 300 230 1.30 50 2 20 2 -- 3.50 mm2 THWN 20mm Ø RSC MINIMUM SIZE WIRE FOR POWER AND LIGHTING CIRCUIT
HOMERUNS SHALL BE 3.5 mm2 AND INSULATED FOR 600VOLTS.
7 LIGHT OUTLET, 3 -- 100W 300 230 1.30 50 2 20 2 -- 3.50 mm2 THWN 20mm Ø RSC LIKEWISE, ALL CONDUCTORS SHALL BE COLOR-CODED.
SMALLEST RACEWAY SHALL BE 15mmØ. (NOMINAL) M
8 LIGHT OUTLET, 2 -- 100W 200 230 0.87 50 2 20 2 -- 3.50 mm2 THWN 20mm Ø RSC
40 AT/AF, 2 POLE
5. ALL OUTLET BOXES SHALL BE GALVANIZED GAUGE NO. 16 DEEP 230 VOLTS BOLT-ON, 10KAIC

9 LIGHT OUTLET, 3 -- 100W 300 230 1.30 50 2 20 2 -- 3.50 mm2 THWN 20mm Ø RSC TYPE.
1 2
10 LIGHT OUTLET, 3 -- 100W 300 230 1.30 50 2 20 2 -- 3.50 mm2 THWN 20mm Ø RSC LIGHT OUTLET 20 AT 20 AT LIGHT OUTLET

6. ALL MATERIALS TO BE USED SHALL BE BRAND NEW AND 3 CONVENIENCE 20 AT 20 AT SPARE


4

11 LIGHT OUTLET, 4 -- 100W 400 230 1.74 50 2 20 2 -- 3.50 mm2 THWN 20mm Ø RSC APPROVED FOR THE PARTICULAR LOCATION AND USAGE. OUTLET

12 LIGHT OUTLET, 3 -- 100W 300 230 1.30 50 2 20 2 -- 3.50 mm2 THWN 20mm Ø RSC 7. EQUIPMENT GROUNDING SYSTEM SHALL BE PROVIDED TO THE
ELECTRICAL SYSTEM AS PER PHILIPPINE ELECTRICAL CODE 2 SINGLE LINE DIAGRAM
13 LIGHT OUTLET, 3 -- 100W 300 230 1.30 50 2 20 2 -- 3.50 mm2 THWN 20mm Ø RSC REQUIREMENT. E-2 SCALE NTS

14 LIGHT OUTLET, 3 -- 100W 300 230 1.30 50 2 20 2 -- 3.50 mm2 THWN 20mm Ø RSC
8. MOUNTING HEIGHT OF WIRING DEVICES SHALL BE AS FOLLOWS:
15 LIGHT OUTLET, 3 -- 100W 300 230 1.30 50 2 20 2 -- 3.50 mm2 THWN 20mm Ø RSC
LIGHT SWITCH 1200mm ABOVE THE FINISH FLOOR OVERHEAD SERVICE ENTRANCE:
230 V, 1Ø, 2W, 60 Hz A.C. W ITH
CONVENIENCE OUTLET 300mm ABOVE FINISH FLOOR 25mm Ø TYPE "F" CONDULET
WEATHERHEAD

16 CONVENIENCE OUTLET, 4 -- 360W 1440 230 6.26 50 2 20 2 -- 3.50 mm2 THWN 20mm Ø RSC PROPOSED REINFORCED CONCRETE PEDESTAL

9. ALL ELECTRICAL WORKS SHALL BE DONE UNDER THE DIRECT POLE: SIZE AS REQUIRED

17 CONVENIENCE OUTLET, 5 -- 360W 1800 230 7.83 50 2 20 2 -- 3.50 mm2 THWN 20mm Ø RSC AND IMMEDIATE SUPERVISION OF A DULY REGISTERED 2 -- 8.00mm2 THWN + 1 -- 5.0mm2 THWN (G)
IN 25mm Ø RSC
ELECTRICAL ENGINEER.
18 CONVENIENCE OUTLET, 3 -- 360W 1080 230 4.70 50 2 20 2 -- 3.50 mm2 THWN 20mm Ø RSC

19 CONVENIENCE OUTLET, 3 -- 360W 1080 230 4.70 50 2 20 2 -- 3.50 mm2 THWN 20mm Ø RSC

20 CONVENIENCE OUTLET, 5 -- 360W 1800 230 7.83 50 2 20 2 -- 3.50 mm2 THWN 20mm Ø RSC ELECTRICAL LEGEND M
PB

8mm2^ THHN GROUND WIRE

1800
21 CONVENIENCE OUTLET, 2 -- 360W 720 230 3.13 50 2 20 2 -- 3.50 mm2 THWN 20mm Ø RSC IN 25mmØ C-CLAMPED TO
POWER LINE COPPER-CLAD GROUNDING ROD

22 CONVENIENCE OUTLET, 3 -- 360W 1080 230 1.30 50 2 20 2 -- 3.50 mm2 THWN 20mm Ø RSC FINISHED FLOOR LINE

SWITCH LINE NATURAL GRADE LINE

23 CONVENIENCE OUTLET, 3 -- 360W 1080 230 4.70 50 2 20 2 -- 3.50 mm2 THWN 20mm Ø RSC GROUNDING SYSTEM
16mmØ x 2400mm LENGTH
COPPER-CLAD GROUNDING ROD

24 CONVENIENCE OUTLET, 3 -- 360W 1080 230 4.70 50 2 20 2 -- 3.50 mm2 THWN 20mm Ø RSC LIGHTING OUTLET
25 AIR CONDITIONING UNIT, 1-- 1500W 1500 230 6.52 50 2 20 2 -- 3.50 mm2 THWN 20mm Ø RSC 3 RISER DIAGRAM
SCALE NTS
LIGHTING OUTLET E-2

26 AIR CONDITIONING UNIT, 1-- 1500W 1500 230 6.52 50 2 20 2 -- 3.50 mm2 THWN 20mm Ø RSC

27 AIR CONDITIONING UNIT, 1-- 1500W 1500 230 6.52 50 2 20 2 -- 3.50 mm2 THWN 20mm Ø RSC CIRCUIT HOMERUN
#
28 AIR CONDITIONING UNIT, 1-- 1500W 1500 230 6.52 50 2 20 2 -- 3.50 mm2 THWN 20mm Ø RSC

29 AIR CONDITIONING UNIT, 1-- 1500W 1500 230 6.52 50 2 20 2 -- 3.50 mm2 THWN 20mm Ø RSC PANEL BOARD

30 AIR CONDITIONING UNIT, 1-- 1500W 1500 230 6.52 50 2 20 2 -- 3.50 mm2 THWN 20mm Ø RSC

TOTAL 26920
CONVENIENCE OUTLET

IT = [ 23260/230 ] [ 80% D.F. ] = 80.90 A FOR FEEDER & UNIT SIZE FOR PROTECTION
USE: 2 -- 8.0 mm2 THWN Cu WIRE USE: 40 AT/AF 230 V MAIN DISCONNECT ABBREVIATIONS:
1 -- 5.0 mm2 THWN Cu WIRE
IN 25 mm Ø PVC
S1 SINGLE POLE WALL SWITCH
IN ONE SWITCH PLATE (10 AMP, 230 VOLTS)

1 ELECTRICAL LOAD SCHEDULE


E 3 Scale 1:125

REPUBLIC OF THE PHILIPPINES PROJECT NAME AND LOCATION: SHEET CONTENTS: DRAFTED: REVIEWED: SUBMITTED: RECOMMENDED: APPROVED: SET NO. SHEET NO.
DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS
NATHANIEL CHRISTIAN MARCELINO
REGIONAL OFFICE NO. 02 ELECTRICAL NOTES
Basic Infrastructure Program (BIP) - Multi-Purpose AND SCHEDULE
ENGINEERING ASSISTANT

ISABELA FOURTH Buildings/ Facilities to support Social Services,


PREPARED: MARLON S. LUCAS ANACLETO SANTOS A. BUMAGAT JR. EMMANUEL A. MANSIBANG JOCELYN P. PALEG E 28
DISTRICT ENGINEERING OFFICE Construction of Multi-Purpose Building, Brgy.
ENGINEER II CHIEF, PLANNING AND DESIGN SECTION ASSISTANT DISTRICT ENGINEER DISTRICT ENGINEER 3 3
QUEZON, SAN ISIDRO, ISABELA Dubinan east, Santiago City JOSE C. BAYAUA JR. 28
ARCHITECT II DATE: DATE: DATE: DATE: