Professional Documents
Culture Documents
MPR Format Feb 2022
MPR Format Feb 2022
Km. 11+500 (Design Km. 11+500 meerut) to Km. 39+240 (Design Km. 39+250 Behsuma) and from km. 86+590(Design CH. 79+500 Bijnor) to
Km.112+545 (Design CH 105+700 Jalalabad) (Design Length = 53.950 Km.) of NH-119 (New NH-34) in the State Uttar Pradesh Under Bharatmala Pariyojna on Hybrid Annuity Mode.
A OGL
2 tests for 1000
Sand Content mtr. IS 2720 P4 Nos. 0 0 0 0 0 0 0 0 0 0
Proctor Density Test (MDD & OMC) 2 tests for 1000 IS 2720 P8 Nos.
mtr. 0 0 0 0 0 0 0 0 0 0
Proctor Density Test (MDD & OMC) 2 tests for 3000 m3 IS 2720 P8 Nos. 0 0 0 38 38 0 38 38 0 38
Free Swelling Index of Soil 2 tests for 3000 m3 IS 2720 P40 Nos. 0 0 0 38 38 0 38 38 0 38
CBR Test for Subgrade/Embankment 1 test for 3000 m3 IS 2720 P16 Nos. 0 0 0 19 19 0 19 19 0 19
Atterberg Limit
One test per 400 lS2720 (Part-5) Nos. 0 0 0 52 52 0 52 52 0 0
cubic meter
1 Test per 3000
Unconfined Compressive Strength IS ; 4332 P- 5 Nos. 0 0 0 0 0 0 0 0 0 0
cum of Mix
Source
Wet AIV Approval/As IS 2386 P4 Nos. 0 0 0 0 0 0 0 0 0 0
required
Source
Water Absorption Approval/As IS 2386 P3 Nos. 0 0 0 0 0 0 0 0 0 0
required
Source
Proctor Density Test Approval/As IS 2720 P8 Nos. 0 0 0 0 0 0 0 0 0 0
required
Atterberg Limit
One test per 400 lS2720 (Part-5) Nos. 0 0 0 40 40 0 40 40 0 0
cubic meter
Regularly , through
Cement Content procedural check Nos. 0 0 0 0 0 0 0 0 0 0
Source
Wet AIV Approval/As IS 2386 P4 Nos. 0 0 0 0 0 0 0 0 0 0
required
Source
Water Absorption Approval/As IS 2386 P3 Nos. 0 0 0 0 0 0 0 0 0 0
required
Source
Proctor Density Test Approval/As IS 2720 P8 Nos. 0 0 0 0 0 0 0 0 0 0
required
Unconfined Compressive Strength test 1 Test per 3000 IS; 456 / IS ; 4332 Nos.
on a set of 3 specimen cum of Mix P- 5 0 0 0 5 5 0 5 5 0 0
Initial Setting Time & Final Setting Time For Every Batch / IS 4031 P5 Nos.
Lot 0 0 0 4 4 0 4 4 0 0
Gradation Test for Coarse Agg 1 Test / Day / Plant IS 383 Nos. 0 0 0 57 56 1 57 56 1 0
Gradation Test for Fine Agg 1 Test / Day / Plant IS 383 Nos. 0 0 0 29 28 1 29 28 1 0
1 Test/Source/As
Flakiness Index required IS 2386 P1 Nos. 0 0 0 0 0 0 0 0 0 0
1 Test/Source/As
Aggregate Impact Value required IS 2386 P4 Nos. 0 0 0 0 0 0 0 0 0 0
8 Lab CBR testing equipment for conducting CBR testing, load frame with 5
Tonne capacity, electrically operated with speed control as per IS:2720 Nos 1
(Part 16) and consisting of following:
a. CBR moulds 150 mm dia- 175 mm ht. Nos 53
b. Tripod stands for holding dial gauge holder Nos 1
c. CBR plunger with settlement dial gauge holder Nos 1
d. Surcharge weight 147 mm dia 2.5 kg wt. Nos 53
e. Spacers disc 148 mm dia 47.7 mm ht. With handle Nos 1
f. Perforated plate (Brass) Nos 53
g. Soaking tank for accommodating 6 CBR moulds Nos 3
h. Proving rings of 3000 kg, 5000 kg capacity each set 1
i. Dial gauges 25 mm travel-0.01 mm/division Nos 4
9 Standard penetration test equipment Nos 1
10 Speedy moisture meter complete with chemicals Nos 11
(C) FOR BITUMEN AND BITUMINOUS MIXES
1 Constant temperature bath for accommodating bitumen test specimen,
electrically operated, and thermostatically controlled (to accomm date Nos 2
minimum six Specimens)
2 Penetrometer automatic type, including adjustable weight arrangement
and needles as per IS: 1203-1958 Nos 1
2 Moulds
a 7.06x7.06x7.06 cm Cement mortar moulds
Nos 9