midas Gen Academic SEIS LOAD CALC.

PROJECT TITLE :
Company Client
Author Ramzi File Name BENOLIRAO FINAL EXAM RSA.spf

* MASS GENERATION DATA FOR LATERAL ANALYSIS OF BUILDING [UNIT: kN, m]


_________________________________________________________

STORY TRANSLATIONAL MASS ROTATIONAL CENTER OF MASS


NAME (X-DIR) (Y-DIR) MASS (X-COORD) (Y-COORD)
----------- ----------- ----------- ----------- ----------- -----------
Roof 290.697284 290.697284 23236.9711 11.2668257 7.37918858
8F 440.519403 440.519403 36417.295 11.2654257 7.37795269
7F 440.519403 440.519403 36417.295 11.2654257 7.37795269
6F 440.519403 440.519403 36417.295 11.2654257 7.37795269
5F 440.519403 440.519403 36417.295 11.2654257 7.37795269
4F 440.519403 440.519403 36417.295 11.2654257 7.37795269
3F 440.519403 440.519403 36417.295 11.2654257 7.37795269
2F 440.519403 440.519403 36417.295 11.2654257 7.37795269
1F 0.0 0.0 0.0 0.0 0.0
----------- ----------- ----------- ----------- ----------- -----------
TOTAL : 3374.33311 3374.33311

* ADDITIONAL MASSES FOR THE CALCULATION OF EQUIVALENT SEISMIC FORCE


_____________________________________________________________________

Note. The following masses are between two adjacent stories or on the
nodes released from floor rigid diaphragm by *Diaphragm Disconnect command.
The masses are proportionally distributed to upper/lower stories according
to their vertical locations. For dynamic analysis, however, floor masses
and masses on vertical elements remain at their original locations.

STORY TRANSLATIONAL MASS


NAME (X-DIR) (Y-DIR)
-------------- ----------- -----------
Roof 0.0 0.0
8F 0.0 0.0
7F 0.0 0.0
6F 0.0 0.0
5F 0.0 0.0
4F 0.0 0.0
3F 0.0 0.0
2F 0.0 0.0
1F 42.6760283 42.6760283
-------------- ----------- -----------
TOTAL : 42.6760283 42.6760283

* EQUIVALENT SEISMIC LOAD IN ACCORDANCE WITH UNIFORM BUILDING CODE 1997 [UNIT: kN, m]
_____________________________________________________________________________________________

Seismic Zone Factor (Z) : 0.40


Importance Factor (I) : 1.00
Soil Profile Type : SD

Seismic Source Type : A


Closest Distance To Known Seismic Source [km] : 10.00
Near Source Factor, Na (UBC-97 Table 16-S) : 1.00
Near Source Factor, Nv (UBC-97 Table 16-T) : 1.20

Seismic Coefficient, Ca (UBC-97 Table 16-Q) : 0.44


Seismic Coefficient, Cv (UBC-97 Table 16-R) : 0.77

Fundamental Period Associated With X-dir. (Tx) : 1.0820


R Factor of Lateral System for X-direction (Rx) : 8.5000
Seismic Coefficient for X-dir. UBC-97(Para.1630.2.1) : 0.083506

Fundamental Period Associated With Y-dir. (Ty) : 1.0820

Modeling, Integrated Design & Analysis Software Print Date/Time : 05/08/2022 00:36
http://www.MidasUser.com
Gen 2021 -1/4-
midas Gen Academic SEIS LOAD CALC.

PROJECT TITLE :
Company Client
Author Ramzi File Name BENOLIRAO FINAL EXAM RSA.spf

R Factor of Lateral System for Y-direction (Ry) : 8.5000


Seismic Coefficient for Y-dir. UBC-97(Para.1630.2.1) : 0.083506

Total Effective Weight For X-dir. Seismic Loads (Wx) : 33088.710459


Total Effective Weight For Y-dir. Seismic Loads (Wy) : 33088.710459

Scale Factor For X-directional Seismic Loads : 1.00


Scale Factor For Y-directional Seismic Loads : 0.00

Accidental Eccentricity For X-direction (Ex) : None


Accidental Eccentricity For Y-direction (Ey) : None

Torsional Amplification for Accidental Eccentricity : Do not Consider


Torsional Amplification for Inherent Eccentricity : Do not Consider

Total Base Shear Of Model For X-direction : 2763.114548


Total Base Shear Of Model For Y-direction : 0.000000
Summation Of Wi*Hi Of Model For X-direction : 460022.886780
Summation Of Wi*Hi Of Model For Y-direction : 0.000000
--------------------------------------------------------------------------------------

===========================
ECCENTRICITY RELATED DATA
===========================

X - D I R E C T I O N A L L O A D Y - D I R E C T I O N A L L O A D

STORY ACCIDENTAL INHERENT ACCIDENTAL INHERENT ACCIDENTAL INHERENT ACCIDENTAL INHERE


NT
NAME ECCENT. ECCENT. AMP.FACTOR AMP.FACTOR ECCENT. ECCENT. AMP.FACTOR AMP.FA
CTOR
---------- ---------- ---------- ---------- ---------- ---------- ---------- ---------- ------
----
Roof 0.0 0.0 1.0 0.0 0.0 0.0 1.0
0.0
8F 0.0 0.0 1.0 0.0 0.0 0.0 1.0
0.0
7F 0.0 0.0 1.0 0.0 0.0 0.0 1.0
0.0
6F 0.0 0.0 1.0 0.0 0.0 0.0 1.0
0.0
5F 0.0 0.0 1.0 0.0 0.0 0.0 1.0
0.0
4F 0.0 0.0 1.0 0.0 0.0 0.0 1.0
0.0
3F 0.0 0.0 1.0 0.0 0.0 0.0 1.0
0.0
2F 0.0 0.0 1.0 0.0 0.0 0.0 1.0
0.0
G.L 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.0
---------------------------------------------------------------------------------------------------
----

---------------------------------------------------------------------------------------------------
----
The accidental amplification factors are automatically set to 1.0 when torsional amplification effe
ct
to accidental eccentricity is not considered.
The inherent amplification factors are automatically set to 0 when torsional amplification effect
to inherent eccentricity is not considered.
The inherent amplification factors are all set to 'the input value - 1.0'.(This is to exclude the t

Modeling, Integrated Design & Analysis Software Print Date/Time : 05/08/2022 00:36
http://www.MidasUser.com
Gen 2021 -2/4-
midas Gen Academic SEIS LOAD CALC.

PROJECT TITLE :
Company Client
Author Ramzi File Name BENOLIRAO FINAL EXAM RSA.spf

rue
inherent torsion)
---------------------------------------------------------------------------------------------------
----

** Story Force , Seismic Force x Scale Factor + Added Force

S E I S M I C L O A D G E N E R A T I O N D A T A X - D I R E C T I O N

STORY STORY STORY SEISMIC ADDED STORY STORY OVERTURN. ACCIDENT. INHERENT TOTA
L
NAME WEIGHT LEVEL FORCE FORCE FORCE SHEAR MOMENT TORSION TORSION TORS
ION
---------- -------- ------- -------- -------- -------- -------- --------- --------- --------- -----
----
Roof 2850.578 25.6 614.3992 0.0 614.3992 0.0 0.0 0.0 0.0
0.0
8F 4319.733 22.4 537.1788 0.0 537.1788 614.3992 1966.078 0.0 0.0
0.0
7F 4319.733 19.2 460.439 0.0 460.439 1151.578 5651.127 0.0 0.0
0.0
6F 4319.733 16.0 383.6992 0.0 383.6992 1612.017 10809.58 0.0 0.0
0.0
5F 4319.733 12.8 306.9593 0.0 306.9593 1995.716 17195.87 0.0 0.0
0.0
4F 4319.733 9.6 230.2195 0.0 230.2195 2302.676 24564.44 0.0 0.0
0.0
3F 4319.733 6.4 153.4797 0.0 153.4797 2532.895 32669.7 0.0 0.0
0.0
2F 4319.733 3.2 76.73983 0.0 76.73983 2686.375 41266.1 0.0 0.0
0.0
G.L. -- 0.0 -- -- -- 2763.115 50108.07 --- --- --
-
---------------------------------------------------------------------------------------------------
----

S E I S M I C L O A D G E N E R A T I O N D A T A Y - D I R E C T I O N

STORY STORY STORY SEISMIC ADDED STORY STORY OVERTURN. ACCIDENT. INHERENT TOTA
L
NAME WEIGHT LEVEL FORCE FORCE FORCE SHEAR MOMENT TORSION TORSION TORS
ION
---------- -------- ------- -------- -------- -------- -------- --------- --------- --------- -----
----
Roof 2850.578 25.6 614.3992 0.0 0.0 0.0 0.0 0.0 0.0
0.0
8F 4319.733 22.4 537.1788 0.0 0.0 0.0 0.0 0.0 0.0
0.0
7F 4319.733 19.2 460.439 0.0 0.0 0.0 0.0 0.0 0.0
0.0
6F 4319.733 16.0 383.6992 0.0 0.0 0.0 0.0 0.0 0.0
0.0
5F 4319.733 12.8 306.9593 0.0 0.0 0.0 0.0 0.0 0.0
0.0
4F 4319.733 9.6 230.2195 0.0 0.0 0.0 0.0 0.0 0.0
0.0
3F 4319.733 6.4 153.4797 0.0 0.0 0.0 0.0 0.0 0.0
0.0
2F 4319.733 3.2 76.73983 0.0 0.0 0.0 0.0 0.0 0.0
0.0
G.L. -- 0.0 -- -- -- 0.0 0.0 --- --- --

Modeling, Integrated Design & Analysis Software Print Date/Time : 05/08/2022 00:36
http://www.MidasUser.com
Gen 2021 -3/4-
midas Gen Academic SEIS LOAD CALC.

PROJECT TITLE :
Company Client
Author Ramzi File Name BENOLIRAO FINAL EXAM RSA.spf

-
---------------------------------------------------------------------------------------------------
----

=================================================
COMMENTS ABOUT TORSION
=================================================

---------------------------------------------------------------------------------------------------
----
If torsional amplification effects are considered :
---------------------------------------------------------------------------------------------------
----
Accidental Torsion , Story Force * Accidental Eccentricity * Amp. Factor for Accidental Eccentricit
y
Inherent Torsion , Story Force * Inherent Eccentricity * Amp. Factor for Inherent Eccentricity

---------------------------------------------------------------------------------------------------
----
If torsional amplification effects are not considered :
---------------------------------------------------------------------------------------------------
----
Accidental Torsion , Story Force * Accidental Eccentricity
Inherent Torsion , 0

---------------------------------------------------------------------------------------------------
----
The inherent torsion above is the additional torsion due to torsional amplification effect.
The true inherent torsion is considered automatically in analysis stage when the seismic force is
applied to the structure.
---------------------------------------------------------------------------------------------------
----

Modeling, Integrated Design & Analysis Software Print Date/Time : 05/08/2022 00:36