PROJECT TITLE :
Company Client
Author Ramzi File Name BENOLIRAO FINAL EXAM RSA.spf
Note. The following masses are between two adjacent stories or on the
nodes released from floor rigid diaphragm by *Diaphragm Disconnect command.
The masses are proportionally distributed to upper/lower stories according
to their vertical locations. For dynamic analysis, however, floor masses
and masses on vertical elements remain at their original locations.
* EQUIVALENT SEISMIC LOAD IN ACCORDANCE WITH UNIFORM BUILDING CODE 1997 [UNIT: kN, m]
_____________________________________________________________________________________________
Modeling, Integrated Design & Analysis Software Print Date/Time : 05/08/2022 00:36
http://www.MidasUser.com
Gen 2021 -1/4-
midas Gen Academic SEIS LOAD CALC.
PROJECT TITLE :
Company Client
Author Ramzi File Name BENOLIRAO FINAL EXAM RSA.spf
===========================
ECCENTRICITY RELATED DATA
===========================
X - D I R E C T I O N A L L O A D Y - D I R E C T I O N A L L O A D
---------------------------------------------------------------------------------------------------
----
The accidental amplification factors are automatically set to 1.0 when torsional amplification effe
ct
to accidental eccentricity is not considered.
The inherent amplification factors are automatically set to 0 when torsional amplification effect
to inherent eccentricity is not considered.
The inherent amplification factors are all set to 'the input value - 1.0'.(This is to exclude the t
Modeling, Integrated Design & Analysis Software Print Date/Time : 05/08/2022 00:36
http://www.MidasUser.com
Gen 2021 -2/4-
midas Gen Academic SEIS LOAD CALC.
PROJECT TITLE :
Company Client
Author Ramzi File Name BENOLIRAO FINAL EXAM RSA.spf
rue
inherent torsion)
---------------------------------------------------------------------------------------------------
----
S E I S M I C L O A D G E N E R A T I O N D A T A X - D I R E C T I O N
STORY STORY STORY SEISMIC ADDED STORY STORY OVERTURN. ACCIDENT. INHERENT TOTA
L
NAME WEIGHT LEVEL FORCE FORCE FORCE SHEAR MOMENT TORSION TORSION TORS
ION
---------- -------- ------- -------- -------- -------- -------- --------- --------- --------- -----
----
Roof 2850.578 25.6 614.3992 0.0 614.3992 0.0 0.0 0.0 0.0
0.0
8F 4319.733 22.4 537.1788 0.0 537.1788 614.3992 1966.078 0.0 0.0
0.0
7F 4319.733 19.2 460.439 0.0 460.439 1151.578 5651.127 0.0 0.0
0.0
6F 4319.733 16.0 383.6992 0.0 383.6992 1612.017 10809.58 0.0 0.0
0.0
5F 4319.733 12.8 306.9593 0.0 306.9593 1995.716 17195.87 0.0 0.0
0.0
4F 4319.733 9.6 230.2195 0.0 230.2195 2302.676 24564.44 0.0 0.0
0.0
3F 4319.733 6.4 153.4797 0.0 153.4797 2532.895 32669.7 0.0 0.0
0.0
2F 4319.733 3.2 76.73983 0.0 76.73983 2686.375 41266.1 0.0 0.0
0.0
G.L. -- 0.0 -- -- -- 2763.115 50108.07 --- --- --
-
---------------------------------------------------------------------------------------------------
----
S E I S M I C L O A D G E N E R A T I O N D A T A Y - D I R E C T I O N
STORY STORY STORY SEISMIC ADDED STORY STORY OVERTURN. ACCIDENT. INHERENT TOTA
L
NAME WEIGHT LEVEL FORCE FORCE FORCE SHEAR MOMENT TORSION TORSION TORS
ION
---------- -------- ------- -------- -------- -------- -------- --------- --------- --------- -----
----
Roof 2850.578 25.6 614.3992 0.0 0.0 0.0 0.0 0.0 0.0
0.0
8F 4319.733 22.4 537.1788 0.0 0.0 0.0 0.0 0.0 0.0
0.0
7F 4319.733 19.2 460.439 0.0 0.0 0.0 0.0 0.0 0.0
0.0
6F 4319.733 16.0 383.6992 0.0 0.0 0.0 0.0 0.0 0.0
0.0
5F 4319.733 12.8 306.9593 0.0 0.0 0.0 0.0 0.0 0.0
0.0
4F 4319.733 9.6 230.2195 0.0 0.0 0.0 0.0 0.0 0.0
0.0
3F 4319.733 6.4 153.4797 0.0 0.0 0.0 0.0 0.0 0.0
0.0
2F 4319.733 3.2 76.73983 0.0 0.0 0.0 0.0 0.0 0.0
0.0
G.L. -- 0.0 -- -- -- 0.0 0.0 --- --- --
Modeling, Integrated Design & Analysis Software Print Date/Time : 05/08/2022 00:36
http://www.MidasUser.com
Gen 2021 -3/4-
midas Gen Academic SEIS LOAD CALC.
PROJECT TITLE :
Company Client
Author Ramzi File Name BENOLIRAO FINAL EXAM RSA.spf
-
---------------------------------------------------------------------------------------------------
----
=================================================
COMMENTS ABOUT TORSION
=================================================
---------------------------------------------------------------------------------------------------
----
If torsional amplification effects are considered :
---------------------------------------------------------------------------------------------------
----
Accidental Torsion , Story Force * Accidental Eccentricity * Amp. Factor for Accidental Eccentricit
y
Inherent Torsion , Story Force * Inherent Eccentricity * Amp. Factor for Inherent Eccentricity
---------------------------------------------------------------------------------------------------
----
If torsional amplification effects are not considered :
---------------------------------------------------------------------------------------------------
----
Accidental Torsion , Story Force * Accidental Eccentricity
Inherent Torsion , 0
---------------------------------------------------------------------------------------------------
----
The inherent torsion above is the additional torsion due to torsional amplification effect.
The true inherent torsion is considered automatically in analysis stage when the seismic force is
applied to the structure.
---------------------------------------------------------------------------------------------------
----