Sl.

# Question Name Answer Remarks


1 Permit to work G.I. G.I. 2.100
2 Tool Box Meeting when should be held Every new activity
3 Crane out rigger pad should be 150%
4 Wire rope load capacity 1” 8 Ton Formula: 1” * 8ton = 8
ton
5 Excavation slope should be in 45 degree
6 Excavation slope formula 1.5 e.g. if deep 3 meter and
wide 4 meter: should be
4.5 meter should slop
distance
7 Hard barricading / top rail of scaffold 200 pounds
capacity should be
8 Between Camp building and fence distance 15 feet
9 Can Diesel / oil store in a heavy plastic gallon False Should be metal
10 Scaffolding planks size 2” * 9” / 2” * 12”
11 Gas Testing Procedure according to G.I.2.709
12 Crane Lifts Procedures according to G.I.7.028
13 Crane should stay away from trench or 1.8 meter
excavation edge.
14 Wind speed max. for crane lifting 20mph
15 Every platform max. distance 9 meter (30 feet)
E.g. a tower scaffold means then ladder
should not go direct, after 9 meter shall be a
platform.
16 Scaffolding procedure should be according G.I.8.001
17 Fire for combustible materials A type Fire extinguisher
18 Electrical max volte can use should be 125v
19 After hot work fire watch shall stay till 30 minute
20 From a fire extinguisher how much time 8 to 15 second Depend on kg.
fight
21 If deep excavation more than 1.2m Call confined space
meter
22 If an excavation more than 75 feet length, Every 25 feet should be
Then how many ladder should use as access a ladder as access.
23 Soil type C Muddy, soft etc..
24 Diesel generator should away from 20 meter (50 feet)
combustible material / gas cylinder.
25 Site toilet how many for workers 1 toilet for 15 worker
26 Between laydown to site distance min. 50 meter
27 Spoil pills from edge of excavation or 2 feet
trench
28 Scaffolding bracing zigzag should be 32 degree to 53 degree
between
29 Noise levels 85 dB For 8 hours
30 Man basket should not use more than wind 25kmph.
31