You are on page 1of 3

1.

Color of extract tool:


A. Red
B. Green
C. White
2. Examples of EWIS are:
A. Wires, cables, busbars, connectors
B. Fiber optical cables
C. Portable electrical devices
3. What is GVI means?
A. General Variable Interconnection
B. General Visual Inspection
C. Ground Visual Inspection
4. Detail Inspection is:
A. Visual examination of an internal or external area
B. Visual check of the system, powerplant or structure
C. Full examination of a specific component
5. When checking ground point, make sure that:
A. The ground equipment tighten to aircraft structure or avionic rack
B. The protective coating is not damaged
C. The ground equipment tighten to aircraft structure or avionic rack, the protective coating is
not damaged, and no corrosion
6. Which statement is not correct about wire harness?
A. Cable bend radius are not less than the minimum value necessary
B. Dust and lint do not need to be collect
C. There is no loose harness or incorrectly attached harness
7. What is not acceptable when you do connector checking
A. Cable tie is missing
B. Make sure there is locking wire
C. There is no loosen connector or backshell
8. What is ESPM?
A. Electrical Standard Practices Manual
B. Electrical Supplemental Procedure Manual
C. Electrical Supplemental Practices Manual
9. Which wire size is the smallest wire?
A. 18
B. 20
C. 22
10. About wire/cable identification, what does the first 4 digit (number) means?
A. No. of the wire/cable in the circuit
B. No. of the circuit define by ATA Spec 100
C. No. of the color code
11. When checking circuit breaker, relays, make sure that:
A. They are correctly installed,
B. There is no sign of overheat
C. Both answer are correct.
12. AWM is:
A. Aircraft Wiring Manual
B. Aircraft Working Manual
C. Aircraft Wiring Menu
13. To find a high resistance or open circuit, carry out.
A. a milli-volt drop test.
B. a continuity check.
C. a bonding check.
14. In a front release connector the pin will be.
A. released from rear and extracted from the front.
B. released from the front and extracted from the front.
C. released from the front and extracted from the rear.
15. With a rear release connector, the pin will be.
A. released from the front and extracted from the rear.
B. released from the rear and extracted from the front.
C. released from the rear and extracted from the rear.
16. The maximum operating temperature for a nickel plated copper or aluminium connector is.

A. 260°C.
B. 135°C.
C. 200°C.
17. Before effecting a crimp, the bare ends of a cable should be.
A. tightly twisted.
B. twisted lightly in the direction of the lay.
C. straightened out.
18. A hole is placed in the lowest point of electrical cable conduit.
A. to allow for pull-through of the cables.
B. to secure the conduit to a piece of aircraft structure.
C. to allow for drainage of moisture.
19. The minimum distance between electrical cable splices is.
A. 3 feet.
B. 12 inches.
C. 500 mm
20. When splicing a cable with a soldered joint, the operation is finished when.
A. the solder has melted.
B. the solder sleeve disappears.
C. the solder and insulation have formed.
21. When manufacturing an electrical connector the unused holes are.
A. filled with connectors.
B. filled with connectors and blanked.
C. covered with blanks.
22. Why are copper wires used in electrical systems?.
A. They have high permeability.
B. They do not give off a magnetic field.
C. They have a low resistance to current.
23. A white/blue insertion-extraction tool would be used on a cable of what size?.
A. 10.
B. 22.
C. 16.
24. What gauge of pin would a blue plastic insert / extract tool be used on?.
A. 12 - 10.
B. 16 - 14.
C. 22 - 18.
25. What gauge of pin would a yellow plastic insert/extract tool be used on?.
A. 16 - 14.
B. 12 - 10.
C. 22 - 18.