You are on page 1of 7

1.

Examples of EWIS are:


A. Wires, cables, busbars, connectors
B. Fiber optical cables
C. Portable electrical devices

2. What is ESPM?
A. Electrical Standard Practices Manual
B. Electrical Supplemental Procedure Manual
C. Electrical Supplemental Practices Manual

3 . Circuit Breaker has auxiliary contact use for purpose:


A. Monitored
B. Not monitored
C. Back-up

4. Route 1M is meaning:
A. Not safety route
B. Sensitive route
C. EFCS route

5. To test scrimping tool


A. GO-NoGO tool must be used for test
B. NoGO side must go through the crimping tool
C. Tool must be brought to national calibration center for test

6. Which tool use for bonding test


A. Milliohm meter
B. Megaohm meter
C. Voltmeter

7. Checking ground point


A. Must be tightened to aircraft structure, and protective coating is not damaged, and no
corrosion
B. Must be tightened to aircraft structure
C. The protective coating must not be damaged

8. What is GVI means?


A. General Variable Interconnection
B. General Visual Inspection
C. Ground Visual Inspection

9. Detail Inspection is:


A. Visual examination of an internal or external area
B. Visual check of the system, powerplant or structure
C. Full examination of a specific component

10. Which one follwing is the main cause for lethality?


A. Voltage
B. Current
C. Resistance

11. When checking circuit breaker, relays, make sure that:


A. They are correctly installed,
B. There is no sign of overheat
C. Both answer are correct.
12. Repair for wire damage grade 0 is?
A. No repair required
B. Permanent repair
C. Minor repair

13. How many type of EWIS inspection ?


A. 2
B. 3
C. 4

14. A wire marks 2313-0035 on its body, 4 last digits bring what information?
A. Wire number
B. Wire type
C. Wire size

15. What following is the result for ESD affect?


A. Wires are burnt or broken
B. Integrated Circuits are damaged
C. Relays are broken

16. A wire has P/N ASBE0261CF24. Letters ‘CF’ mean?


A. Wire number
B. Wire type
C. Wire size

17. You want to clean a surface by cloth with liquid, you do?
A. Put cloth to the liquid
B. Put the liquid to cloth
C. Whatever above is ok provided efficiency

18. Which wire gauge has smallest section.


A. E0260BF24
B. E0260BF20
C. E0260BF18

19. Which statement is not correct about wire harness?


A. Cable bend radius are not less than the minimum value necessary
B. Dust and lint do not need to be collect
C. There is no loose harness or incorrectly attached harness

20. You want to clean a surface by agent, you do?


A. Apply firstly agent to small area for test then clean if no serious reactions
B. Apply agent then clean as usual
C. Dry the surface in the air

21. Color of extract tool?


A. Blue
B. Yellow
C. White

22. Do you need to use special tool for GVI?


A. No needed
B. Needed
C. For clear defect, should use special tool

23. Which ATA chapter give EWIS inspection task


A. ATA 25.
B. ATA 20.
C. ATA 12.
24. Which Tool does use for wiring isolation check
A. Megaohm meter
B. Milliohm meter
C. Volt meter

25. What is AWM?


A. Aircraft Wiring Manual
B. Aircraft Working Menu
C. Aircraft Wiring Modification

26. Which ones following are applicable in EPA for ESD prevention?
A. wrist strap, anti-static bags, humid control, anti-static mat
B.wrist strap, ESD jacket, anti-static bags, humid control, anti-static mat
C.wrist strap, ESD jacket, humid control, anti-static mat

27. How many ways to protect EWIS components during maintenance?


A. Plastic bag, protective cap, screened room
B. Protective cap, screened room
C.Plastic bag, dummy receptacle, protective cap

28. For the dry human skin, the resistance could be


A. Less than 1000 ohms
B. Over 500,000 ohms
C. Only 100 ohms

29. If you let a current more than 50 miliamps goes through you, you will

A. Get severe pains


B. Can’t let go
C. Probable fatal

30 What is ESD ?

A. sudden flow of electricity between two electrically charged objects caused by contact,
an electrical short, or dielectric breakdown
B. a flow of electricity between two electrically charged objects caused by contact
C. sudden flow of electricity between two electrically charged objects caused by
disconnection.
31 Where could we set up an EPA ?

A. Small work station


B. Large manufacturing area
C. Either small work station or large manufacturing area

32.If the wire repairing is grade 3, we have to perform


A. Permanent repair
B.Tempo repair only and must not stay on aircraft more than 24months
C.A regular check of repair is necessary at intervals that must not be more than 24 months

33.How may repair grade for cable


A. 3
B. 4
C. 5
34. What is not acceptable when you do connector checking
A. Cable tie is missing
B.Make sure there is locking wire
C.There is no loosen connector or backshell

35. General Inspection is:

A Visual examination of an internal or external area, installation or assembly


B Must be used special tool for inspection.
C Full examination of a specific component.
36. What is additional check when replacement LRU?
A. This is the check LRU P/N
B. This is the extra check LRU after replacement for operation/functional test
C. This is the check by reading LRU P/N from OBRM whether it matches with P/N in front face
or not

37. . When checking ground point, make sure that:


A. The ground equipment tighten to aircraft structure or avionic rack
B. The protective coating is not damaged, and no corrosion.
C. Both of above

38. Which document for repair or replacement of damaged engine cables


A. ESPM 20-53
B. AMM 70-71
C. ESPM 20-46

39. To do the electrical bonding ref:


A. AMM 20-28
B. CMM 20-21
C. ESPM 20-48

40. How many splice permitted for damaged repair on the same wire.
A. Only one splice
B. Not more three slices
C. No required

1. Most electric shocks from tools have been caused by :


A. the failure of insulation between the current- carrying parts and the metal frames of tools
B. the failure of insulation between the metal frame parts of tools
C. the failure ofinsulation between the insulationparts and the metal frames of tools

2. A ground fault is
A. an intentional electrical path between a power source and a grounded surface
B. an unintentional electrical path between power sources
C. an unintentional electrical path between a power source and a grounded surface
3. . Fora direct current, the value indicated on the ammeter is:
A. Voltage
B. Resistance
C. Current

4. A voltmeter measures
A. The potential difference between two points
B. The potentialof one point
C. The resistance difference between two points

5. The voltage is measured by connecting the voltmeter


A. Insequence to thecircuit
B. In parallel to the circuit
C. Inparallel or Insequence to thecircuitif you like

6. In accordance with Ohm’s law, the value of the resistance


is equal to
A. the multiplication of thevoltage across the resistor and current passing through
theresistor
B. the division of the current passing through the resistorand the voltage across the
resistor
C. the division of the voltage across the resistor and current passing through the
resistor

7. The acronym ARINC means:


A. Aircraft Rack Inclusion.
B. Aircraft Radar Incoming.
C. Aeronautical Radio Incorporated.

8. In EWIS Symbol ˷ is :

A. alternating current
B. direct current
C. earth ground

9. In EWIS, ATA stand for


A. Air Transport Association
B. Advanced Technology Attachment
C. Advanced Tactical Aircraft

10. Testing the continuity of a circuit requires use the


A. an oscilloscope.
B. a multimeter
C. a bond tester

11. To test the electrical insulation, use


A. megohm-meters
B. bond tester
C. multimeter
12. In order to check continuity with a multimeter, set the multimeter to the
A. volts setting
B. ohm setting
C. Amps setting

13. In a front release connector the pin will be.


A. released from rear and extracted from the front.
B. released from the front and extracted from the front.
C. released from the front and extracted from the rear.

14. The reason for cutting back properly a wire before crimping is to:
A. complies with ARINC specification.
B. keeps as short as possible wire length
C. ensure that area of contact will not be oxidized

15. With a rear release connector, the pin will be.

A. released from the front and extracted from the rear.


B. released from the rear and extracted from the front
C. released from the rear and extracted from the rear.
16. When manufacturing an electrical connector the unused holes are.
A. filled with connectors.
B. filled with connectors and blanked.
C. covered with blanks.
.