1.0 SCOPE:
This procedure describes the method and technique of Hydro Test for Pressure
Vessels and Heat Exchangers after completion of fabrication.
3.0 SYSTEM:
C. The blanks and the fasteners shall be compatible with the original material
specification used for the construction.
• The water filled shall be stored in the equipment for a sufficient time,
so as to stabilize the temperature of the water and the metal.
• Ensure that the air pockets are totally eliminated, before applying
pressure.
E. Ensure that the equipment is examined to see that it is tight and all other
filling lines and appurtenances are removed/ disconnected.
F. Completed dry the spilled water and make the total external surface dry.
I. Fix at least two pressure gauges, one at the highest point and other at the
water inlet nozzle. The applied test pressure shall be measured at the
highest point of the equipment. The range of Pressure gauges selected
shall be 1 ½ to 4 times the Test Pressure.
L. Check for any leakages on weld joins, base metal, flange joints etc.
M. Identify/ witness, if any and dry the wet areas by using compressed air.
O. QA and QC Engineer shall carry out the inspection and record the results
in Pressure Test Report. Any leakage or any pressure drop from the joint,
or metal is not accepted.
Q. If specified in QAP and ITP, QA and QC Engineer shall offer the hydro
test to, customer or inspection agency and prepare Pressure Test Report.
R. After acceptance by, inspection agency, customer, remove the hydro test
pump connection, open out the vent value and drain the water. Ensure
vacuum is not created in the equipment.
S. After the pressure test the pressure gauge shall be subjected to verification
of calibration.
SPACETECH EQUIPMENTS & Procedure No : SES-HYD-01
Revision No : 0
STRUCTURALS PVT. LTD. Date : 21/02/2018
An ISO 9001:2015 Certified Company Page No : 5 of 5
A-17, ADDITIONAL MIDC, ANAND NAGAR, AMBERNATH (EAST) PIN –
421 506 DIST: THANE, MAHARASHTRA
T. After water is drained out, use compressed air for about ½ hour so as to
remove the moisture from the equipment and dry the equipment and
record in report.
U. Get the Pressure test report endorsed by the witnessing and accepting
authorities.
4.0 RESPONSIBILITIES: