FOUNDATIONS LOADS TABLE

CONTRACTOR DOCUMENT Class: R


Acceptance Discipline Checker
Date
Status Code Abbreviation Name Signature

Acceptance Status Description:


A Accepted
CONTRACTOR’s acceptance of this document does in no way relieve the
AC Accepted with Comments
VENDOR of its contractual obligation
CR Commented
NA Not Accepted

4239-FB-VD-LF9859170B0203003-IS00
filename: 4239-FB-VD-LF9859170B0B203003_IS00.xlsx

02
01
00 29.Dec.21 IFI - Issue for Information
IFI V. Canavesi F.Caldiroli M.Ferrara

Issue Date Reason for Issue – Revision Description Prepared Checked Approved
Digital signature

This document is Tecnimont’s property, and cannot be used by others for any purpose, without prior written consent
E-Sign - P: Valerio.Canavesi C: Fabio.Caldiroli C: Marsilio.Resente C: A: Marzio.Ferrara ON: 23-Dec-2021
0 00 29/12/2021 IFI V.Canavesi F.Caldiroli M.Resente M.Ferrara
Rev. Rev. Data Descrizione / Description Comp. Con. 1 Con. 2 Visto
MAC rev. Date Prepared 1st check 2nd check Approv.

Address: Piazza Buffoni, 3 - 21013 Gallarate (VA) - Italy


Tel. +39 0331 738111 - Fax: +39 0331 738377
E-Mail: macchi@macchiboiler.it - Web Site: http://www.macchiboiler.it

Cliente: Impianto : Fg. 2 di 3


PORT HARCOURT REFINERY
client :
TECNIMONT plant : Sheet 2 of 3
COMPANY - NIGERIA
Titolo / title : Rev. 00
FOUNDATIONS LOADS TABLE Job No. : 1252-0-C-023
Client Doc. No.: 4239-FB-VD-LF9859170B0B203003
Questo documento e tutte le informazioni in esso contenute This document and all information thereon are strictly
sono strettamente riservate di proprietà Sofinter S.p.a . reserved and property of Sofinter S.p.A. Div. Macchi
Divisione Macchi, da non utilizzare per scopi diversi da quelli They have not to be used for any purposes other
per cui sono state fornite. than those they have been provided
Title :
FOUNDATIONS LOADS TABLE

Client: Plant : Doc. nr. 1252-0-M-023 sh. 3 of 3


PORT HARCOURT REFINERY Rev. 0
GALLARATE (VA) – ITALY TECNIMONT
COMPANY - NIGERIA
Structural Engineering Dept. Date 29/12/2021

DEAD LOADS LIVE LOADS WIND ± X LOADS WIND ± Y LOADS ± THERMAL LOADS PRESSURE LOADS OPERATING LOADS TEST LOADS
Plinth SERVICE
FX FY FZ MX MY MZ FX FY FZ MX MY MZ FX FY FZ MX MY MZ FX FY FZ MX MY MZ FX FY FZ MX MY MZ FX FY FZ MX MY MZ FX FY FZ MX MY MZ FX FY FZ MX MY MZ
kN kN kN kNm kNm kNm kN kN kN kNm kNm kNm kN kN kN kNm kNm kNm kN kN kN kNm kNm kNm kN kN kN kNm kNm kNm kN kN kN kNm kNm kNm kN kN kN kNm kNm kNm kN kN kN kNm kNm kNm
M1 Boiler - - -95 - - - - - - - - - - - -90 - - - - - -40 - - - 45 45 - - - - - - - - - - - - -10 - - - - - -15 - - -
P3 Boiler - - -95 - - - - - - - - - - - -90 - - - - - -40 - - - 45 45 - - - - - - - - - - - - -10 - - - - - -15 - - -
M2 Boiler - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
P4 Boiler - - -95 - - - - - - - - - - - -90 - - - - - 40 - - - 45 -45 - - - - - - - - - - - - -10 - - - - - -15 - - -
M3 Boiler - - -95 - - - - - - - - - - - -90 - - - - - 40 - - - 45 -45 - - - - - - - - - - - - -10 - - - - - -15 - - -
M4 Boiler - - -285 - - - - - -15 - - - 110 - 130 - - - 25 - -55 - - - -45 135 - - - - 15 - - - - - - - -60 - - - - - -80 - - -
P1 Boiler - - -395 - - - - - -15 - - - 35 - 50 - - - 25 - -55 - - - -45 195 - - - - - - - - - - - - -100 - - - - - -130 - - -
M5 Boiler - - -400 - - - - - -5 - - - 35 - - - - - - 210 - - - - - - - - - - - - - - - - - - -125 - - - - - -150 - - -
P2 Boiler - - -405 - - - - - -15 - - - 35 - 50 - - - -25 - 55 - - - -45 -195 - - - - - - - - - - - - -85 - - - - - -120 - - -
M6 Boiler - - -300 - - - - - -15 - - - 110 - 130 - - - -25 - 55 - - - -45 -135 - - - - - - - - - - - - -40 - - - - - -60 - - -

P5 Steel Structure - - -5 - - - - - -5 - - - 5 - 35 - - - - - -10 - - - - - - - - - - - - - - - - - - - - - - - - - - -


P6 Steel Structure - -15 -20 - - - - -35 -50 - - - ± 5 ± 10 ± - 15 - - - - ± 60 ± 70 - - - - - - - - - - - - - - - - - - - - - - - - - - -
P7 Steel Structure 10 15 -55 - - - 30 35 -135 - - - ± 35 - ± - 35 - - - ±-5 ± 15 ± - 50 - - - - - - - - - - - - - - - - - -5 - - - - - -10 - - -
P8 Steel Structure -10 - -65 - - - -25 - -145 - - - ± 35 - ± 20 - - - ±-5 - ± 20 - - - - - - - - - - - - - - - - - -10 - - - - - -15 - - -
P9 Steel Structure - - -15 - - - - - -25 - - - - ± - 10 ± - 20 - - - - ± 40 ± 75 - - - - - - - - - - - - - - - - - - - - - - - - - - -
P10 Steel Structure - - -35 - - - - - -75 - - - - - - - - - - - ± - 15 - - - - - - - - - - - - - - - - - -5 - - - - - -10 - - -
P11 Steel Structure - - -35 - - - - - -55 - - - - - ± - 90 - - - - - ± - 20 - - - - - - - - - - - - - - - - - -10 - - - - - -15 - - -
P12 Steel Structure - - -20 - - - -5 - -20 - - - ± 35 - ± 105 - - - ± 10 - ± - 70 - - - - - - - - - - - - - - - - - -5 - - - - - -10 - - -
- -
P13 Steel Structure - - -15 - - - - - -30 - - - ± 10 - ± - 40 - - - - ± 10 ± - 20 - - - - - - - - - - - - - - - - - - - - - - - - - - -
P14 Steel Structure - - -15 - - - - - -30 - - - ± 10 - ± 40 - - - - ± 40 ± - 35 - - - - - - - - - - - - - - - - - - - - - - - - - - -
P15 Steel Structure - - -10 - - - - - -25 - - - ± 10 - ± - 35 - - - - - ± 10 - - - - - - - - - - - - - - - - - - - - - - - - - - -
P16 Steel Structure - - -20 - - - - - -45 - - - ± 10 - ± 35 - - - - - ± 45 - - - - - - - - - - - - - - - - - - - - - - - - - - -
P17 Steel Structure - - -10 - - - - - -15 - - - ± 5 - ±-5 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
P18 Steel Structure - - -5 - - - - - -10 - - - ± 10 - ± - 35 - - - - - ± 15 - - - - - - - - - - - - - - - - - - - - - - - - - - -
P19 Steel Structure - - -20 - - - - - -35 - - - ± 10 - ± 35 - - - - - ± - 15 - - - - - - - - - - - - - - - - - - - - - - - - - - -
P20 Steel Structure - - -10 - - - - - -15 - - - ± 5 - ± 5 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

P21 Steel Structure - 5 -25 - - - - - -20 - - - - - ± - 65 - - - - ± 10 ± - 20 - - - - - - - - - - - - - - - - ± 15 -115/+105 - - - - - -10 - - -


P22 Steel Structure - - - - - - - - -5 - - - ± 20 - ± 60 - - - - - - - - - - - - - - - - - - - - - ± 20 - +75/-70 - - - - - - - - -
P23 Steel Structure - - -5 - - - - - -15 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
P24 Steel Structure - - -5 - - - - - -10 - - - - ± 5 ± 10 - - - - - ± - 20 - - - - - - - - - - - - - - - - - ± 30 - - - - - - - - -
P25 Steel Structure - -5 -20 - - - - - -10 - - - - - ± 5 - - - - ± 5 ± 15 - - - - - - - - - - - - - - - - ± 15 +35/-45 - - - - - -10 - - -
P26 Steel Structure - - -5 - - - - - -10 - - - - ±-5 ± - 10 - - - - ± 10 ± 25 - - - - - - - - - - - - - - - - ± - 10 ± 30 - - - - - - - - -

P27 Steel structure of ECO - - -20 - - - - - -45 - - - ± 10 - ± - 10 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -


P28 Steel structure of ECO - - -20 - - - - - -45 - - - - - ± 10 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
P29 Steel structure of ECO - 25 -210 - - - - - -20 - - - ± 130 ± 80 ± - 240 - - - ±-5 ± 25 ± - 30 - - - - - - - - - 15 15 -50 - - - - - -10 - - - - - -15 - - -
P30 Steel structure of ECO - 20 -180 - - - - - -20 - - - - ± - 80 ± 240 - - - - ± 20 ± - 35 - - - - - - - - - - -15 50 - - - - - -10 - - - - - -15 - - -
P31 Steel structure of ECO - -25 -185 - - - - - 0 - - - ± 25 ± 70 ± 25 - - - ± 5 ± 25 ± 40 - - - - - - - - - 5 10 15 - - - - - -10 - - - - - -15 - - -
P32 Steel structure of ECO - -20 -160 - - - - - 0 - - - ± 25 ± - 70 ± - 25 - - - - ± 20 ± 25 - - - - - - - - - 5 -5 -15 - - - - - -10 - - - - - -15 - - -

P33 Air Duct - - -45 - - - - - - - - - ± 45 - ± - 150 - - - - ± 15 ± 15 - - - - ± 10 - - - - - 10 -25 - - - - - - - - - - - - - - -


P34 Air Duct - - -45 - - - - - - - - - ± 45 - ± 150 - - - - ± 15 ± 15 - - - - ± 10 - - - - - 10 -25 - - - - - - - - - - - - - - -
P35 Air Duct - - -25 - - - - - - - - - ± 30 - ± - 30 - - - - - ± - 15 - - - - ± - 10 - - - - - - - - - - - - - - - - - - - - - -
P36 Air Duct - - -25 - - - - - - - - - ± 30 - ± 30 - - - - - ± - 15 - - - - ± - 10 - - - - - - - - - - - - - - - - - - - - - -
P37 Wind Box - - -55 - - - - - - - - - ± 15 - ± - 20 - - - - - - - - - - - - - - - - - -25 - - - - - - - - - - - - - - -
P38 Wind Box - - -55 - - - - - - - - - ± 15 - ± 20 - - - - - - - - - - - - - - - - - -25 - - - - - - - - - - - - - - -

P50 Stack - - -200 - - - - - -120 - - - ± 105 - - - ± 1900 - - ± 105 - ± - 1900 - - - - - - - - - -2 - 10 - - - - - - - - - - - - - -


P51 Fuel Gas Skid - HOLD - - -30 - - - - - - - - - ± 20 - - - ± 10 - - ± 15 - ± 5 - - - - - - - - - - - - - - - - - - - - - - - - - -
P52 Fuel Oil Skid - HOLD - - -20 - - - - - - - - - ± 20 - - - ± 15 - - ± 20 - ± - 15 - - - - - - - - - - - - - - - - - - - - - - - - - -
P53 F.D. Fan - HOLD see 1252-0-M-024 see 1252-0-M-024 see 1252-0-M-024 see 1252-0-M-024 see 1252-0-M-024 see 1252-0-M-024 see 1252-0-M-024 see 1252-0-M-024
P54 Lube Oil Skid - HOLD - - -40 - - - - - - - - - ± 20 - - - ± 20 - - ± 20 - ± - 20 - - - - - - - - - - - - - - - - - - - - - - - - - -
P55 Sampling System - HOLD - - -20 - - - - - - - - - ± 15 - - - ± 15 - - ± 5 - - - - - - - - - - - - - - - - - - - - - - - - - - - -

PS1 Stair - - -5 - - - - - -20 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

NOTES:
[1] FOR REFERENCE SYSTEM SEE DOCUMENT N. 1252-0-M-020
[2] MOMENTS FOLLOW THE RIGHT HAND RULE
[3] - MEANS "NOT APPLICABLE"
[4] HOLD MEANS "LOAD DATA IS PRELIMINARY TO BE CONFIRMED BY MACCHI"
[5] FOR F.D. FAN LOADS FOR BOILER REFER TO DOCUMENT 1252-0-M-024
[6] DEAD LOAD = EMPTY LOAD OF BOILER OR SELF WEIGHT OF SERVICE STRUCTURE INCLUDING EQUIPMENT (EMPTY) AND PIPING VERTICAL LOAD
[7] TEST LOAD = FLUID DURING HYDROSTATIC TEST
[8] OPERATING LOAD = LOADS DURING OPERATING CONDITION OF THE BOILER AND BATTEY LIMITS LOAD
[9] WIND AND THERMAL LOAD MUST BE CONSIDERED IN BOTH DIRECTIONS
[10] PRESSURE LOAD IS DUE TO FLUE GAS THRUST
[11] WIND LOAD = DERIVED ACCORDING TO ASCE 7-16 PRESCRIPTIONS; BASIC WIND SPEED 122 mph; EXPOSURE CATEGORY C; RISK CATEGORY III
[12] WIND LOADS FOR STACK = CALCULATED IN ACCORDANCE WITH STACK DESIGN CODE (CICIND), ASD METHOD; TO BE COMBINED TO OTHER LOADS (CALCULATED AS PER ASCE 7-16 CODE, LRFD METHOD) USING PROPER LOAD FACTORS