You are on page 1of 14

Hitachi

TX
SERIES

Escalator
Copyright:Hitachi Elevator (China) Co., Ltd. TX 2019.07
RE-C001Q 0719

Hitachi s brand-new TX series escalators materialize to its design concepts of Safety, Reliability,
Comfort and Durability, and continue its commitment to environment-considered and energy-saving,
CONTENTS
as well as its pursuits of high quality, which provides efficient and convenient transportation solu-
Safe and Reliable 01-06
tions for buildings.
Efficiency and Energy-saving 07-10

Diversified Design 11-14

Note: CGs presented in this catalogue are based on the recommended specification of Hitachi, with some options are Product Specification 15-18
included. Actual product may vary depending on selected specifications.
SAFE
AND RELIABLE
Provide all-around protection for
passengers.

Note: These CGs are based on the recommended specification of Hitachi, with
some options are included. Actual product may vary depending on
selected specifications.
01 02
Safety of step

Optional Optional

8mm Convex surface

8mm raised cleats on both sides of step, 0.5mm convex surface on each stainless
unique four sides demarcation lines design steel step the demarcation line area at the rear
effectively guide passenger onto the safe of each step, which enhance the passenger’s
standing area to prevent entrapment. touch feeling of stepping onto,to reduce the
risks of slipping.

Standard
The safe tooth pitch of step cleat is
8.4mm ,e ff e c t i v e l y p r e v e n t t h e
8.4mm
high-heeled shoes and umbrellas
from being entrapped into its teeth.

Safety of landing plate

Anti-slip

Anti-collapse

Anti-slip Standard Anti-collapse Standard

The anti-slip pattern meet the assessment The embedded retangular landing plate
group of R10 , to effectively prevent the is fitted onto safe and reliable support
passengers from slipping.(Conforming to structure, to avoid any shifting and
DIN51130 standard). falling of landing plate.

Note: These CGs are based on the recommended specification of Hitachi, with some options are included. Actual
product may vary depending on selected specifications.

03 04
Safety detection Full range of safety protection devices

Landing plate close abnormity detection (MIS)

Anti-reversal
Handrail inlet safety device (TIS)

Magnetic brake safety device (MGS)

Emergency stop button

Comb plate safety device (CMS)

Missing step protective device (MSD)

Skirt guard safety device (SGS)*

Area safety detection device*

Handrail running speed


abnormity detection (HSD)

Reversal protection Standard Area safety detection Optional

Emergency Braking Safety Gear can be provided When the sensor detects passenger movement beyond the
for H≤6m in addition to the main operation brake, for handrail, a voice announcement will alert the passenger.
safe braking in the event of chain breakage.
*Note:Sensor is usually set up on one side where there is obstacle.
In case of customer requesting to have sensor on both sides,
please contact Hitachi.
Skirt guard safety brush
Skirt guard safety device (SGS)*

Auxilary brake(ABS)*
Emergency stop button
Electronic safety monitor Standard (Standard for H>6m)

TX escalator entirely enhance the electronic system safety performance. By comparing the operating status of main
Driving chain safety
Machine and Step which improve the redundancy detection, avoiding overspeed and reversal situation, the electronic Step sinking safety Landing plate close
device (DCS)
safety integrity level achieve to SIL3 (higher than EN Standard of SIL2). device (STS) abnormity detection(MIS)

Emergency braking
safety gear(H≤6m)

Overload, loss of phase and phase


reversal protection

Over-speed, under-speed and reversal safety protection Handrail breaking safety


device (HRS)* Step chain safety
device (TCS)

Step operation detection Main machine operation detection Comb plate safety device (CMS)

Handrail inlet safety device (TIS)

Missing step protective device (MSD)

*: Optional

05 06
EFFICIENCY
AND ENERGY
SAVING
Assist the environmentally
conscious saving operation,
energy-saving buildings.
Comprehensively improve the drive technology, to achieve better

efficiency and energy saving; in addition, provide choices of

operation modes according to passenger flow, to maximize

customer's benefits .

ISO 25745-3:2015

Low energy consumption

A+++ ≤ 55%
A +++
A++ ≤ 60%

A+ ≤ 65%

A ≤ 70%

B ≤ 80%

C ≤ 90%

D ≤ 100%

E > 100%

High energy consumption

Operation mode:

Power off Auto start Slow speed

Label No:I0215765 Valid until:14.11.2021

Hitachi TX Escalator satisfies Class A+++, the highest level specified

in ISO 25745-3“Energy performance of lifts, escalators and moving

walks -- Part 3”

07 08
Energy Saving Mode Optional

When the sensor detects no passenger for a predetermined period of time, the escalator automatically enters
the energy-saving mode. When the sensor detects an approaching passenger, the escalator gradually
accelerates to the rated speed.

Standby speed
(Energy-saving mode) Rated speed

Auto dual speed operation


Speed
Rated speed
(With passenger)

Detection of
passenger

Standby speed
(Without passenger)

Time
Standby Speed Acceleration Rated Speed Deceleration Standby speed

Auto start-stop operation


Speed

Rated speed
(With passenger)

Detection of
passenger

Without passenger Time


Stop Acceleration Rated Speed Deceleration Stop

Auto dual speed + Auto start-stop operation


Speed

Rated speed
(With passenger)
Detection of
passenger

Standby Speed

Stop Time
Stop Acceleration Rated Speed Deceleration Stop

Note: These CGs are based on the recommended specification of Hitachi, with some options are included. Actual
product may vary depending on selected specifications.

09 10
DIVERSIFIED
DESIGN
Match perfectly with buildings.
Escalators are important features for building passenger traffic. The

decorative configuration of escalator will affect the overall space

architecture in the buildings. As for the upgrade of products, Hitachi

promotes the diversified design, to adapt to the different decoration

styles of shopping malls and buildings.

Note: These CGs are based on the recommended specification of Hitachi, with
some options are included. Actual product may vary depending on
selected specifications.
11 12
Enhance the space utilization LED lighting
Standard Optional

TX series escalators brand new technological innovation White Handrail lighting


(Standard color) ( L Model only )
optimizes truss structure size, saving additional space to be
White Skirt guard lighting
used for more valuable purposes for the customers. (Standard color) ( Stripe-type )
Green Step demarcation
(Standard color) lighting
White
Footlight
(Standard color)

Green Comb lighting


(Standard color)

Expand available space

White Skirt guard lighting


(Standard color) ( Hidden-type )

( LED color selection: white, green, red, blue and light-yellow )

Balustrade design
Simple appearance design of the balustrade,will naturally guide passengers to slip the handrail.Optional LED handrail lights will
further enhance architecture design.

TX-EN Model TX-L Model TX-P Model


Transparent tempered glass Transparent tempered glass + handrail lighting Hairline stainless steel

Handrail colors
Standard Optional

Black Gray Red Blue Beige Green Brown Charcoal


Note: Printed color and actual color may differ slightly

Step design
Standard Optional Optional

Standard for Indoor Option for Indoor Standard for Outdoor


Aluminum alloy Stainless steel Aluminum alloy
No painting Painting Painting
(No demarcation line) Reinforced synthetic resin 3 edges yellow boundary
Around 4 edges (Painting)
(Fluorescent yellow)

Note: These CGs are based on the recommended specification of Hitachi, with some options are included. Actual product may vary depending on selected
specifications.

13 14
PRODUCT
SPECIFICATION

Note: These CGs are based on the recommended specification of Hitachi, with
some options are included. Actual product may vary depending on
selected specifications.
15 16
Functional Configuration Standard specifications by escalator model
Function Standard Optional 1200 Type 1000 Type

Step chain safety device(TCS) √ Nominal width (mm) 1200 1000

Driving chain safety device(DCS) √ Step width (mm) 1004 802

Comb plate safety device(CMS) √ Maximum capacity (persons/h) 6000 4800

Handrail inlet safety device(TIS) √ Rated speed(m/s) 0.5

Step sinking safety device(STS) √ Angle of inclination 30°/ 35°

Handrail running speed abnormity detection(HSD) √ Power supply 50/60Hz,AC 3-phase 220/230/380/400/415/440/460/480V, Single-phase 110/220/230/240V

Missing step protective device(MSD) √ Motor Three-phase AC induction motor

Landing plate close abnormity detection(MIS) √ Operation method Key switch operation,reversible

Magnetic brake safety device(MGS) √ Operating environment Indoor/Outdoor

Skirt guard safety brush √


Safety device Over-speed,under-speed and reversal safety protection √ Name Model TX-EN TX-L TX-P

Emergency stop button √ Interior panel Transparent tempered glass Hairline stainless steel

Overload,loss of phase and phase reversal protection √ Handrail lighting - LED (White) -

Fault detection on important components of control panel Handrail Polyurethane (Black)


Standard

Safe stopping distance detection √ Balustrade Skirt guard Indoor: Painted steel, Outdoor: Raw stainless steel

Emergency braking safety gear √(H≤6m) Inner and outer deck Indoor: Painted steel, Outdoor: Hairline stainless steel

Protection against electrostatic loading √ Skirt guard lighting Hidden-type/Strip-type LED (White)
Optional
Auxiliary brake(ABS) √(H>6m) √(H≤6m) Footlight LED (White)

Skirt guard safety device(SGS) √ Comb Reinforced synthetic resin (Fluorescent Yellow)

Handrail breaking safety device(HRS) Standard Comb plate Aluminum alloy


Floor

Area safety detection device Landing plate Aluminum alloy

Optional Comb lighting LED (Green)
Auto Lubrication √(Outdoor) √(Indoor)
Auto dual speed Step cleat and step riser Indoor:Aluminum alloy (No painting) , Outdoor: Aluminum alloy

Auto start-stop Standard Indoor: No demarcation line

Step Demarcation line
Outdoor: 3 edges yellow boundary (Painting)
Automatic running Auto dual speed+auto start-stop √
Constant speed only Optional Demarcation lighting LED (Green)

Running direction indicator √
Required
Fault alarm Building Side Required Minimum
Power Supply Source Control Panel

Escalator Motor Circuit Breaker Building Side Section Area
Fault recording from Building Model Rise H(mm) Circuit Breaker for GND (earthing)
Capacity (kW) Transformer
3-Phase/ Frequency

Fault handling Size (A) Wire
Current(A)*1 Curve (kVA) (sqmm)
Fault display at control panel √

Fault display at skirt guard √ H≤ 5500 5.5 40 ≥ 40 D 12.5 4


Monitoring Dry contact interface √ 1000 Type 5500< H ≤ 7500 7.5 50 ≥ 50 D 16 8
7500< H ≤ 9500 11 63 ≥ 63 D 18 10
EN115-1:2008+A1:2010 √ 220V,230V
50/60Hz H≤ 4500 5.5 40 ≥ 40 D 12.5 4
Fire alarm,shutter gate ,earthquake operation interface
(when escalator receives signal, escalator stops)
√ 1200 Type 4500< H ≤ 6000 7.5 50 ≥ 50 D 16 8
Other functions
6000< H ≤ 9500 11 63 ≥ 63 D 18 10
Earthquake sensor √
H≤ 5500 5.5 32 ≥ 32 D 12.5 4
Automatic broadcast √
1000 Type 5500< H ≤ 7500 7.5 32 ≥ 32 D 16 6
7500< H ≤ 9500 11 40 ≥ 40 D 18 8
380-415V,440V,460V,480V
50/60Hz H≤ 4500 5.5 32 ≥ 32 D 12.5 4
1200 Type 4500< H ≤ 6000 7.5 32 ≥ 32 D 16 6
6000< H ≤ 9500 11 40 ≥ 40 D 18 8

*1:Setting value of leakage current detector ≥300 (mA)

17 18
Escalator planning data for 30°inclination escalator Escalator planning data for 30°inclination escalator
Applicable for Rise H ≤ 6000mm (Unit: mm) Applicable for Rise 6000mm<H≤9500mm (Unit: mm)

Escalator plan view Escalator plan view

Finished Floor Level(By others) Finished Floor Level(By others) Finished Floor Level(By others) Finished Floor Level(By others)
Landing plate Landing plate

W3
W6
W6
W3

WP WP WP WP
(Lower) Barrier(By others) (Upper) (Lower) Barrier(By others) (Upper)

Escalator side view Escalator front view Escalator side view Escalator front view
φ150 Suspension Hole(By others) φ 150 Hoisting Hole(By others) φ 150 Hoisting Hole(By others)
【 】:With the condition of H≤6000 with 3 flat steps (optional spec)
(Max.Load:7.2H+43100N) (Max.Load:7.2H+49000N) (Max.Load:7.2H+49000N)

200 200
L*4(=1.732H+2280+A)【(=1.732H+2680+A)】
L*4( =1.732H+2680+A)
50*5 2180 1.732H A 50*5 20 W5 20 50*5 2580 1.732H A 50*5
【2580】 ≥1.732x(o.h+2300)+A+50 W2
1800 ≥2500 ≥1.732x(o.h+2300)+A+50 20 W5 20
W Access restriction device
vertical deflector*2 (By others) Barrier(By others) 【2200】 W1 vertical deflector*2(By others) 2200 ≥2500 W2
φ150 Suspension Hole(By others) (By others) Barrier(By others) W
φ 150 Hoisting Hole(By others) Access restriction device
(Max.Load:7.2H+29400N) W1
(By others)
o.h ≥1200

(Max.Load:7.2H+33300N)

o.h ≥1200
F.F.L

920

200(90) 1025 920


WP
WP

700
200 A-150 200

1025
A-150

700
Finished Floor Level

80
≥2300

≥2300

0
(By others) Finished Floor Level
80

200(90)

88
(By others)
0

0
88

Exterior Panel

450
Rise H

20
Power Supply on right hand

Rise H
Power Supply on right hand Exterior Panel
(By others)

0(7
R3
20

side of top machine(By others) side of top machine(By others) (By others)

0)*
0(7

≥2500 1550 Exterior Panel ≥2500 1950 Exterior Panel

1
Finished Floor Level
0)*

【1950】 Side & Bottom(By others) Finished Floor Level


1

Side & Bottom(By others)

450
(By others)
(By others)
450

R4

920
920

30°
F.F.L
30°

WP
WP

1100

1000
1100

1100
1100

1000

≥4790
【4790】
≥4390 M*4 J*4 K*4 W4
W4
N*4 K*4 W6 N*4 W6

External Dimension(Length)(mm) Intermediate frame supporting beam portion

No. of A (mm) W4
Code Type Rise
flat steps
380~415V 220,230,440,460,480V
50/60Hz 50/60Hz
2 2430 2830

100
H≤6000
3 Truss
No. of flat step Intermediate Support
Standard 1000Type W4-230

450
2830
6000<H≤7500 3

(100)
EN115-1 2008+A1(2010) 1200Type Bearing Plate(400(L)×305(W)×20(T)) Bearing Plate
3230 Support Beam (By others) (By others)
(By others)
7500<H≤9500 3 2930

Reaction Load(N) Overall Dimension (Width)(mm) 180


Support Beam
(By others)
≥50 300 ≥50 ≥25 230 ≥50 ≥50 230 ≥25
Number of
No. Model Rise
H(mm) supporting Number
flat step
of
R1 R2 R3 R4 1200 Type 1000 Type
beam
1 2 9.2H+35000 9.2H+28000 - - W (Balustrade) 1226 1026

2
2
3 9.2H+38600 9.2H+31360 - - W1 (Step) 1004 802
Details of supports on Frame supporting portion Frame supporting portion
1200 Type both ends (Construction)
3 3 2/3 5.2K+14000 5.2N+4000 5.2(K+N)+5000 -
W2 (Handrail) 1236 1036
320
4 4 2/3 5.2K+14000 5.2M+4000 5.2(K+J)+5000 5.2(J+M)+2000
H≤9500 W3 (Landing plate) 1550 1350 140
5 2 8.4H+33000 8.4H+26000 - -
Bearing Plate*3(By others)
2 W4 (Truss) 1510 1310
6 3 8.4H+36200 8.4H+28960 - - Floor Finishing Level(By others) (welded to the reinforced steel bars)
Length of
1000 Type bearing plate
Landing Plate Finished Floor Level(By others)
4.6K+14000 4.6N+4000 4.6(K+N)+5000 - W5 (Total width of escalator) 1550 1350 Frame of 140
7 3 2/3 Truss
landing plate

1200 type: 970 (1000 type: 770) 140


1200 type: 1590 (1000 type: 1390)
8 4 2/3 4.6K+14000 4.6M+4000 4.6(K+J)+5000 4.6(J+M)+2000 W6 (Min.pit/opening) 1590 1390

(1000 type: 385)


5×M20 Bolt

80

130

130
Note: *1. If no bottom lights or pipelines need to be installed between the truss and the exterior panel, this dimension is 70mm at the inclined section and 90mm at the horizontal section.
Bearing plate*3(By others)
*2. When the distance between the center line of handrail and the escalator or any obstacle in the building is less than 500mm, vertical deflector without any sharp edges shall be Steel Angle

110±10

110±10
20
installed at the intersection. 200×200×20

*3. Dimension of bearing plate for both ends : 150mm (W)×20mm (T)×1590mm (L) [1200 type]/1390mm(L) [1000type]. 1200 type: 485 Truss
30 150
*4. If L is more than 15102mm, an intermediate support beam is required. K,M,N,J≤15100 mm. 50 270
270
*5. Upon planning, the gaps(clearances) between Escalator and building at both upper and lower part must be designed within the range of 40~90mm including the tolerance at the
building side.

19
20
Escalator planning data for 35°inclination escalator Architectual requirement for outdoor escalator
Applicable for Rise H ≤ 6000mm (Unit: mm) (Unit: mm)

Escalator plan view Escalator plan view

Finished Floor Level(By others) Finished Floor Level(By others)


Landing plate
Finished Floor Level(By others)
Finished Floor Level(By others)
W6
W3

U
WP WP

S T

S T
(Lower) Barrier(By others) U T S
(Upper)

W3
S T U

390
420

Escalator side view Escalator front view Drain(By Others) Barrier(By Others)

φ150 Suspension Hole(By others)


(Max.Load:7.2H+43100N) (Lower) (Upper)

200
L(=1.428H+2310+A)
50*4 2210 1.428H A 50*4
20 W5 20
≥1.428x(o.h+2300)+A+50
W2
vertical deflector*1(By others) Barrier(By others) 1870 ≥2500 W Access restriction device
φ150 Suspension Hole(By others) W1
(By others)
(Max.Load:7.2H+29400N)
Escalator front view
o.h ≥1200

Escalator side view

920
F.F.L
WP
A-150 700

1025
200
Finished Floor Level
R1
≥2300

(By others) Canopy(By Others)


80

200(90)
0
90
Rise H

Power Supply on right hand Exterior Panel


0

20 W5 20
(By others)
20

side of top machine(By others) W2


0(7

≥2500 1580 Exterior Panel ≥30°


0)

Finished Floor Level ≥2500 W


*

Barrier(By Others)
1

Side & Bottom(By others) Barrier(By Others)


(By others) Vertical deflector(By Others) W1

F.F.L
920

35°

≥1200
WP
1000

1100
1100

W6
R2 WP
≥4180 W4 E F E
W6 Finished Floor Level
(By others)

≥2300
Exterior Panel(By Others)

Details of supports on Frame supporting portion Frame supporting portion Step

Rise H
both ends (Constrution) Exterior Panel
320 Sides & Bottom(By Others
≥2500 Finished Floor Level
140 R1 (By others)

20
Bearing Plate*3(By others)

0(7
Floor Finishing Level(By others) Truss
(welded to the reinforced steel bars)

0)
Length of Landing Plate Finished Floor Level(By others)
bearing plate 140
Truss Frame of
W6
landing plate WP
1200 type: 970 (1000 type: 770) 140
1200 type: 1590 (1000 type: 1390)

F F E
80
(1000 type: 385)

130

130

5×M20 Bolt

1450
1450
Bearing plate*3(By others) Steel Angle Drain(By Others) Drain slope 1/10(By Others)
110±10

110±10
20

W4
200×200×20 Drain hole(200×200×200)
(By Others)
420
Drain Diameter R2 W6
Truss φ100(By Others)
1200 type: 485

30 150
50 270
270

Overall Dimension (width)(mm) External Dimension(Length)(mm)

1200 Type 1000 Type A (mm)


No. of
W (Balustrade) 1226 1026
Code Type Rise flat steps 380~415V
50/60Hz
220,230,440,460,480V
50/60Hz
Detail E(F and E are symmetric)
W1 (Step) 1004 802 Standard 1000Type 2 2500 2900
H≤6000
EN115-1 2008+A1(2010) 1200Type Joint Of The Escalator And Floor Cover Plate(By Others)
W2 (Handrail) 1236 1036
W3 (Landing plate) 1550 1350
100≤S≤300 300≤T≤500 U

h≥30
W4 (Truss) 1510 1310
W5 (Total width of escalator) 1550 1350 Reaction Load(N)
W6 (Min.pit/opening) 1590 1390

β=1/10
Model Rise H (mm) No. of supporting point R1 R2
Note: S: 100-300mm.
Note: *1. If no bottom lights or pipelines need to be installed between the truss and
the exterior panel, this dimension is 70mm at the inclined section and 1200 Type 8.2H+36000 8.2H+28000 T: 300-500mm(Slope1/10).
H≤6000 2
90mm at the horizontal section. 1000 Type 7.5H+33000 7.5H+26000 U: Cutter(With Cover Plate).
*2. When the distance between the center line of handrail and the escalator or
any obstacle in the building is less than 500mm, vertical deflector without Consumer should set the slope and gutter according to Detail E.
any sharp edges shall be installed at the intersection.
*3. Dimension of bearing plate for both ends:
150mm (W)×20mm(T)×1590mm (L) [1200 type]/1390mm(L) [1000type].
*4. Upon planning, the gaps(clearances) between Escalator and building at
both upper and lower part must be designed within the range of
40~90mm including the tolerance at the building side.

21 22
Work done by others for escalators

Construction related work (Supply and install)

Item Work Description

1. Opening of holes in floor slabs for installation use and recovery work.

2. Installation of supporting beams for installation use.

3. Opening of suspension holes in floor slabs or sleeve holes for carrying the escalator into place and performing recovery work.

Lowest floor and escalator bottom pits and waterproofing work.


4. (if there is any resident room below the lower machine room, the pit work will be of refractory construction).

5. Finishing work for floors and ceilings around the escalator after completion of escalator installation.

6. Installation & finishing works to barrier and walls around the escalator.

7. External panels on escalator frame (truss).

8. Installation of triangular caution mark in places where the escalator and building ceiling or one escalator and another intersects.

9. If the space between escalators is a stairwell, installation of intermediate down walls, ceilings, handrails, and advance prevention partitions.

10. Joint work in places where the escalator and the building's ceiling border.

Installation of fall protection nets, etc, if the space between the escalator and the building's floor is stairwell or the space between
11.
one escalator and another is a stairwell.

12. Preparation of an entrance to carry in the escalator and perform recovery work if the escalator is to be installed in an existing building.

13. Protection work around the escalator if the escalator is to be installed in an existing building.

14. Opening of a hole in the wall if the operation panel of the escalator is to be installed in the building's wall.

Electrical equipment related work(Supply and install)

Item Work Description

15. Main power supply for the drive motor: lead-in up to the upper control board of the escalator.

16. Power supply for inspection and maintenance : lead-in up to the upper control board of the escalator.

17. Grounding wire: lead-in up to the upper power receiving panel of the escalator.

18. Piping and wiring for the supervisory panel: lead-in from the installation area of the supervisory panel to the power receiving panel of the escalator.

19. Piping and wiring work if the escalator's operation panel is separately installed (built into the wall, etc).

20. Selector switch and its installation for escalator bottom lighting.

21. Installation of emergency lighting.

22. Installation of sprinklers, broadcasting speakers, guide lights, etc.

23. The intensity of illumination at the entrance and exit of escalator shall be at least 50 lux and 15 lux respectively.

Note: These CGs are based on the recommended specification of Hitachi, with some options are included. Actual product may vary depending on selected
specifications.

23 24

You might also like