Copyright:Hitachi Elevator (China) Co., Ltd. TX 2019.07
RE-C001Q 0719
,
Hitachi s brand-new TX series escalators materialize to its design concepts of Safety, Reliability,
Comfort and Durability, and continue its commitment to environment-considered and energy-saving,
CONTENTS
as well as its pursuits of high quality, which provides efficient and convenient transportation solu-
Safe and Reliable 01-06
tions for buildings.
Efficiency and Energy-saving 07-10
Note: CGs presented in this catalogue are based on the recommended specification of Hitachi, with some options are Product Specification 15-18
included. Actual product may vary depending on selected specifications.
SAFE
AND RELIABLE
Provide all-around protection for
passengers.
Note: These CGs are based on the recommended specification of Hitachi, with
some options are included. Actual product may vary depending on
selected specifications.
01 02
Safety of step
Optional Optional
8mm raised cleats on both sides of step, 0.5mm convex surface on each stainless
unique four sides demarcation lines design steel step the demarcation line area at the rear
effectively guide passenger onto the safe of each step, which enhance the passenger’s
standing area to prevent entrapment. touch feeling of stepping onto,to reduce the
risks of slipping.
Standard
The safe tooth pitch of step cleat is
8.4mm ,e ff e c t i v e l y p r e v e n t t h e
8.4mm
high-heeled shoes and umbrellas
from being entrapped into its teeth.
Anti-slip
Anti-collapse
The anti-slip pattern meet the assessment The embedded retangular landing plate
group of R10 , to effectively prevent the is fitted onto safe and reliable support
passengers from slipping.(Conforming to structure, to avoid any shifting and
DIN51130 standard). falling of landing plate.
Note: These CGs are based on the recommended specification of Hitachi, with some options are included. Actual
product may vary depending on selected specifications.
03 04
Safety detection Full range of safety protection devices
Anti-reversal
Handrail inlet safety device (TIS)
Emergency Braking Safety Gear can be provided When the sensor detects passenger movement beyond the
for H≤6m in addition to the main operation brake, for handrail, a voice announcement will alert the passenger.
safe braking in the event of chain breakage.
*Note:Sensor is usually set up on one side where there is obstacle.
In case of customer requesting to have sensor on both sides,
please contact Hitachi.
Skirt guard safety brush
Skirt guard safety device (SGS)*
Auxilary brake(ABS)*
Emergency stop button
Electronic safety monitor Standard (Standard for H>6m)
TX escalator entirely enhance the electronic system safety performance. By comparing the operating status of main
Driving chain safety
Machine and Step which improve the redundancy detection, avoiding overspeed and reversal situation, the electronic Step sinking safety Landing plate close
device (DCS)
safety integrity level achieve to SIL3 (higher than EN Standard of SIL2). device (STS) abnormity detection(MIS)
Emergency braking
safety gear(H≤6m)
Step operation detection Main machine operation detection Comb plate safety device (CMS)
*: Optional
05 06
EFFICIENCY
AND ENERGY
SAVING
Assist the environmentally
conscious saving operation,
energy-saving buildings.
Comprehensively improve the drive technology, to achieve better
customer's benefits .
ISO 25745-3:2015
A+++ ≤ 55%
A +++
A++ ≤ 60%
A+ ≤ 65%
A ≤ 70%
B ≤ 80%
C ≤ 90%
D ≤ 100%
E > 100%
Operation mode:
walks -- Part 3”
07 08
Energy Saving Mode Optional
When the sensor detects no passenger for a predetermined period of time, the escalator automatically enters
the energy-saving mode. When the sensor detects an approaching passenger, the escalator gradually
accelerates to the rated speed.
Standby speed
(Energy-saving mode) Rated speed
Detection of
passenger
Standby speed
(Without passenger)
Time
Standby Speed Acceleration Rated Speed Deceleration Standby speed
Rated speed
(With passenger)
Detection of
passenger
Rated speed
(With passenger)
Detection of
passenger
Standby Speed
Stop Time
Stop Acceleration Rated Speed Deceleration Stop
Note: These CGs are based on the recommended specification of Hitachi, with some options are included. Actual
product may vary depending on selected specifications.
09 10
DIVERSIFIED
DESIGN
Match perfectly with buildings.
Escalators are important features for building passenger traffic. The
Note: These CGs are based on the recommended specification of Hitachi, with
some options are included. Actual product may vary depending on
selected specifications.
11 12
Enhance the space utilization LED lighting
Standard Optional
Balustrade design
Simple appearance design of the balustrade,will naturally guide passengers to slip the handrail.Optional LED handrail lights will
further enhance architecture design.
Handrail colors
Standard Optional
Step design
Standard Optional Optional
Note: These CGs are based on the recommended specification of Hitachi, with some options are included. Actual product may vary depending on selected
specifications.
13 14
PRODUCT
SPECIFICATION
Note: These CGs are based on the recommended specification of Hitachi, with
some options are included. Actual product may vary depending on
selected specifications.
15 16
Functional Configuration Standard specifications by escalator model
Function Standard Optional 1200 Type 1000 Type
Handrail running speed abnormity detection(HSD) √ Power supply 50/60Hz,AC 3-phase 220/230/380/400/415/440/460/480V, Single-phase 110/220/230/240V
Landing plate close abnormity detection(MIS) √ Operation method Key switch operation,reversible
Emergency stop button √ Interior panel Transparent tempered glass Hairline stainless steel
Overload,loss of phase and phase reversal protection √ Handrail lighting - LED (White) -
Safe stopping distance detection √ Balustrade Skirt guard Indoor: Painted steel, Outdoor: Raw stainless steel
Emergency braking safety gear √(H≤6m) Inner and outer deck Indoor: Painted steel, Outdoor: Hairline stainless steel
Protection against electrostatic loading √ Skirt guard lighting Hidden-type/Strip-type LED (White)
Optional
Auxiliary brake(ABS) √(H>6m) √(H≤6m) Footlight LED (White)
Skirt guard safety device(SGS) √ Comb Reinforced synthetic resin (Fluorescent Yellow)
17 18
Escalator planning data for 30°inclination escalator Escalator planning data for 30°inclination escalator
Applicable for Rise H ≤ 6000mm (Unit: mm) Applicable for Rise 6000mm<H≤9500mm (Unit: mm)
Finished Floor Level(By others) Finished Floor Level(By others) Finished Floor Level(By others) Finished Floor Level(By others)
Landing plate Landing plate
W3
W6
W6
W3
WP WP WP WP
(Lower) Barrier(By others) (Upper) (Lower) Barrier(By others) (Upper)
Escalator side view Escalator front view Escalator side view Escalator front view
φ150 Suspension Hole(By others) φ 150 Hoisting Hole(By others) φ 150 Hoisting Hole(By others)
【 】:With the condition of H≤6000 with 3 flat steps (optional spec)
(Max.Load:7.2H+43100N) (Max.Load:7.2H+49000N) (Max.Load:7.2H+49000N)
200 200
L*4(=1.732H+2280+A)【(=1.732H+2680+A)】
L*4( =1.732H+2680+A)
50*5 2180 1.732H A 50*5 20 W5 20 50*5 2580 1.732H A 50*5
【2580】 ≥1.732x(o.h+2300)+A+50 W2
1800 ≥2500 ≥1.732x(o.h+2300)+A+50 20 W5 20
W Access restriction device
vertical deflector*2 (By others) Barrier(By others) 【2200】 W1 vertical deflector*2(By others) 2200 ≥2500 W2
φ150 Suspension Hole(By others) (By others) Barrier(By others) W
φ 150 Hoisting Hole(By others) Access restriction device
(Max.Load:7.2H+29400N) W1
(By others)
o.h ≥1200
(Max.Load:7.2H+33300N)
o.h ≥1200
F.F.L
920
700
200 A-150 200
1025
A-150
700
Finished Floor Level
80
≥2300
≥2300
0
(By others) Finished Floor Level
80
200(90)
88
(By others)
0
0
88
Exterior Panel
450
Rise H
20
Power Supply on right hand
Rise H
Power Supply on right hand Exterior Panel
(By others)
0(7
R3
20
side of top machine(By others) side of top machine(By others) (By others)
0)*
0(7
1
Finished Floor Level
0)*
450
(By others)
(By others)
450
R4
920
920
30°
F.F.L
30°
WP
WP
1100
1000
1100
1100
1100
1000
≥4790
【4790】
≥4390 M*4 J*4 K*4 W4
W4
N*4 K*4 W6 N*4 W6
No. of A (mm) W4
Code Type Rise
flat steps
380~415V 220,230,440,460,480V
50/60Hz 50/60Hz
2 2430 2830
100
H≤6000
3 Truss
No. of flat step Intermediate Support
Standard 1000Type W4-230
450
2830
6000<H≤7500 3
(100)
EN115-1 2008+A1(2010) 1200Type Bearing Plate(400(L)×305(W)×20(T)) Bearing Plate
3230 Support Beam (By others) (By others)
(By others)
7500<H≤9500 3 2930
2
2
3 9.2H+38600 9.2H+31360 - - W1 (Step) 1004 802
Details of supports on Frame supporting portion Frame supporting portion
1200 Type both ends (Construction)
3 3 2/3 5.2K+14000 5.2N+4000 5.2(K+N)+5000 -
W2 (Handrail) 1236 1036
320
4 4 2/3 5.2K+14000 5.2M+4000 5.2(K+J)+5000 5.2(J+M)+2000
H≤9500 W3 (Landing plate) 1550 1350 140
5 2 8.4H+33000 8.4H+26000 - -
Bearing Plate*3(By others)
2 W4 (Truss) 1510 1310
6 3 8.4H+36200 8.4H+28960 - - Floor Finishing Level(By others) (welded to the reinforced steel bars)
Length of
1000 Type bearing plate
Landing Plate Finished Floor Level(By others)
4.6K+14000 4.6N+4000 4.6(K+N)+5000 - W5 (Total width of escalator) 1550 1350 Frame of 140
7 3 2/3 Truss
landing plate
80
130
130
Note: *1. If no bottom lights or pipelines need to be installed between the truss and the exterior panel, this dimension is 70mm at the inclined section and 90mm at the horizontal section.
Bearing plate*3(By others)
*2. When the distance between the center line of handrail and the escalator or any obstacle in the building is less than 500mm, vertical deflector without any sharp edges shall be Steel Angle
110±10
110±10
20
installed at the intersection. 200×200×20
*3. Dimension of bearing plate for both ends : 150mm (W)×20mm (T)×1590mm (L) [1200 type]/1390mm(L) [1000type]. 1200 type: 485 Truss
30 150
*4. If L is more than 15102mm, an intermediate support beam is required. K,M,N,J≤15100 mm. 50 270
270
*5. Upon planning, the gaps(clearances) between Escalator and building at both upper and lower part must be designed within the range of 40~90mm including the tolerance at the
building side.
19
20
Escalator planning data for 35°inclination escalator Architectual requirement for outdoor escalator
Applicable for Rise H ≤ 6000mm (Unit: mm) (Unit: mm)
U
WP WP
S T
S T
(Lower) Barrier(By others) U T S
(Upper)
W3
S T U
390
420
Escalator side view Escalator front view Drain(By Others) Barrier(By Others)
200
L(=1.428H+2310+A)
50*4 2210 1.428H A 50*4
20 W5 20
≥1.428x(o.h+2300)+A+50
W2
vertical deflector*1(By others) Barrier(By others) 1870 ≥2500 W Access restriction device
φ150 Suspension Hole(By others) W1
(By others)
(Max.Load:7.2H+29400N)
Escalator front view
o.h ≥1200
920
F.F.L
WP
A-150 700
1025
200
Finished Floor Level
R1
≥2300
200(90)
0
90
Rise H
20 W5 20
(By others)
20
Barrier(By Others)
1
F.F.L
920
35°
≥1200
WP
1000
1100
1100
W6
R2 WP
≥4180 W4 E F E
W6 Finished Floor Level
(By others)
≥2300
Exterior Panel(By Others)
Rise H
both ends (Constrution) Exterior Panel
320 Sides & Bottom(By Others
≥2500 Finished Floor Level
140 R1 (By others)
20
Bearing Plate*3(By others)
0(7
Floor Finishing Level(By others) Truss
(welded to the reinforced steel bars)
0)
Length of Landing Plate Finished Floor Level(By others)
bearing plate 140
Truss Frame of
W6
landing plate WP
1200 type: 970 (1000 type: 770) 140
1200 type: 1590 (1000 type: 1390)
F F E
80
(1000 type: 385)
130
130
5×M20 Bolt
1450
1450
Bearing plate*3(By others) Steel Angle Drain(By Others) Drain slope 1/10(By Others)
110±10
110±10
20
W4
200×200×20 Drain hole(200×200×200)
(By Others)
420
Drain Diameter R2 W6
Truss φ100(By Others)
1200 type: 485
30 150
50 270
270
h≥30
W4 (Truss) 1510 1310
W5 (Total width of escalator) 1550 1350 Reaction Load(N)
W6 (Min.pit/opening) 1590 1390
β=1/10
Model Rise H (mm) No. of supporting point R1 R2
Note: S: 100-300mm.
Note: *1. If no bottom lights or pipelines need to be installed between the truss and
the exterior panel, this dimension is 70mm at the inclined section and 1200 Type 8.2H+36000 8.2H+28000 T: 300-500mm(Slope1/10).
H≤6000 2
90mm at the horizontal section. 1000 Type 7.5H+33000 7.5H+26000 U: Cutter(With Cover Plate).
*2. When the distance between the center line of handrail and the escalator or
any obstacle in the building is less than 500mm, vertical deflector without Consumer should set the slope and gutter according to Detail E.
any sharp edges shall be installed at the intersection.
*3. Dimension of bearing plate for both ends:
150mm (W)×20mm(T)×1590mm (L) [1200 type]/1390mm(L) [1000type].
*4. Upon planning, the gaps(clearances) between Escalator and building at
both upper and lower part must be designed within the range of
40~90mm including the tolerance at the building side.
21 22
Work done by others for escalators
1. Opening of holes in floor slabs for installation use and recovery work.
3. Opening of suspension holes in floor slabs or sleeve holes for carrying the escalator into place and performing recovery work.
5. Finishing work for floors and ceilings around the escalator after completion of escalator installation.
6. Installation & finishing works to barrier and walls around the escalator.
8. Installation of triangular caution mark in places where the escalator and building ceiling or one escalator and another intersects.
9. If the space between escalators is a stairwell, installation of intermediate down walls, ceilings, handrails, and advance prevention partitions.
10. Joint work in places where the escalator and the building's ceiling border.
Installation of fall protection nets, etc, if the space between the escalator and the building's floor is stairwell or the space between
11.
one escalator and another is a stairwell.
12. Preparation of an entrance to carry in the escalator and perform recovery work if the escalator is to be installed in an existing building.
13. Protection work around the escalator if the escalator is to be installed in an existing building.
14. Opening of a hole in the wall if the operation panel of the escalator is to be installed in the building's wall.
15. Main power supply for the drive motor: lead-in up to the upper control board of the escalator.
16. Power supply for inspection and maintenance : lead-in up to the upper control board of the escalator.
17. Grounding wire: lead-in up to the upper power receiving panel of the escalator.
18. Piping and wiring for the supervisory panel: lead-in from the installation area of the supervisory panel to the power receiving panel of the escalator.
19. Piping and wiring work if the escalator's operation panel is separately installed (built into the wall, etc).
20. Selector switch and its installation for escalator bottom lighting.
23. The intensity of illumination at the entrance and exit of escalator shall be at least 50 lux and 15 lux respectively.
Note: These CGs are based on the recommended specification of Hitachi, with some options are included. Actual product may vary depending on selected
specifications.
23 24