Professional Documents
Culture Documents
Test Report
Model: SMU01 Controller with NGP BMS
Test Results
Test
Test Result Remark
Items
1 Verify the monitoring software and
controller LCD screen analog data PASS
display
2 Verify the alarm and protection
PASS
reporting display
1 Functions
1、 Verify the monitoring software and controller LCD screen analog data display
The battery pack information can be read and shown correctly in both the
Requirement
monitoring software and LCD screen analog display
Connect the communication cable, use the PC software and controller to
Test Method check the battery pack information, change the battery pack address, and
observe whether the corresponding information can be recognized correctly.
Result PASS
Screen Shots:
Battery 1 Battery 10
Test status: Standby
Screen Shots:
Discharge Over Current Alarm
~ End of Report ~