Group 30: Electrical system Malfunctions, MID 128

Fault tracing FMI 4: Abnormally high voltage or short


circuit to earth (ground) has been
If the charge pressure gauge shows that there is
detected
charge pressure when the engine is stopped, this can
be caused by an open circuit to battery negative, be- Fault code conditions:
tween the charge pressure/temperature sensor and
the engine control unit. The voltage on pin 47 in the engine control unit is less
than 0.07 Volt.
FMI 0: Excesive charge air temperature.
Possible reason
Fault code conditions
D9 ● Short circuited signal cable to battery negative.
● Fault in sensor.
Charge air temperature exceeds 125 °C (257 °F).
D12
Suitable action
Charge air temperature exceeds 80 °C (orange lamp).
Charge air temperature exceeds 85 °C (185 °F) (red 1
lamp). Check cables between the sensor and engine control
unit.

Suitable action
2
1 Check sensor.
Check that the engine temperature has a normal value.

2
Check sensor.

FMI 5: The current is less than the normal


value or there is an open circuit.
Fault code conditions:
The voltage on pin 47 in the engine control unit ex-
ceeds 4.95 Volt.

Possible reason
● Short circuited signal cable to battery voltage or 5 V
voltage.
● Open circuit in signal cable.
● Fault in sensor.

Suitable action
1
Check cables between the sensor and engine control
unit.

2
Check sensor.

53

You might also like