You are on page 1of 8

Nama : Hendra Gunawan N Kamis, 10 Des 20

NIM : 2211181009

Kelas : A

Tugas #3 PLC

1. Make the following picture below


a. I/O addressing assingnment
b. Flowchart
c. Program coding
d. Ladder diagram
e. FBD
f. Instruction List
g. Sequencial F. C.

Tugas #4 PLC

2. Make the following picture below


a. I/O addressing assingnment
b. Flowchart
c. Program coding
d. Ladder diagram
e. Timming Diagram
Jawaban

1. a. I/O addressing assingnment

Komponen Nama Statu I/O Number


s
Push button Stop NC Input I: (0.00)
Push button Start NO Input I: (0.02)
Limit Switch Sensor Box NC Input I: (0.03)
Counter Meter Sensor Apel NO Input I: (0.04)
Motor 1 Conveyor Box NO Output Q: (100.00)
Motor 2 Conveyor Apel NO Output Q: (100.01)
Internal Relay Internal Relay NO Output Q: (200.00)
b. Flowchart

Start

Deklarasi
I/O

Ya Tidak
Start== Stop== IR=ON
NC? NO? Conveyor Box =ON

Tidak Ya

IR=OFF Tidak
Sensor
M2=OFF
Box==
NO?

Selesai

Conveyor Box=OFF
Conveyor Apel=ON

S.O.C=ON

Tidak
P.D==
NC?

S.O.C=OFF
C. Program Coding

D. Ladder Diagram
2. a. I/O addressing assingnment

Komponen Symbol Status I/O Number


PB ON Start NO I (0.00)
PB OFF Stop NC I (0.01)
Proximity Snsr Brg NC I (0.02)
Counter Snsr Brg N.OFF I (CNT000)
Timer Tim1 N.OFF I (TIM000)
Motor Konveor Konveyor N.OFF O (100.01)
Selenoid Valve Solenoide N.OFF O (100.02)
Internal Relay I.R N.OFF O (100.00)
b. Flowchart

Start

Declaration
I/O

Ya Tidak
I.R = ON
Start== Stop== M konveyor = ON
NC? NO?

Tidak Ya
Tidak
M konveyor =
Snr Brg==
OFF
NC?

Ya

Tidak
Terdektsi
Selesai ==5unit ?

Ya

I.R = ON
M konveyor = OFF
Solenoid V = ON

Tidak
Tim 00
== 0?

Ya

I.R = ON
M konveyor = ON
Solenoid V = OFF
c. Program Coding

Input Output

0.00 100.0
Start
I.R
I.R
0.01
Stop 100.1

0.02 Konveyor
Snsr Brg

100.2
CTR000
Counter Solenoid

TIM000
Timer
d. Ladder diagram

You might also like