You are on page 1of 1

SOAK WELL(OPTIONAL) SOAK WELL

SEPTIC TANK
SOAK WELL
SEPTIC TANK POSITION

SEPTIC TANK POSITION (OPTIONAL)



E
SLOP

150m

SUBMERSIBLE PUMP POSITION (OPTIONAL)


(OPTIONAL)

150mm Ø
25 Ø GI RAISING MAIN FROM

SLOPE
50mm Ø VENT

EL ± 0.00
CATTLE ENTRY
SUBMERSIBLE PUMP STACK
PIPE COVERED WITH GRATINGS
SLOPE SLOPE 150mm Ø SLOPE 150mm Ø
SLOPE 150mm Ø 150mm Ø SLOPE 150mm Ø
R
S S
R
OVER FLOW PIPE

150mm Ø
100mm Ø RAIN WATER DOWN PIPE STAIR
R
PIPE COVERED WITH GRATINGS

25mmØ

1050mm
PROTECTION WORK OUTER SIDE OF 100 Ø WASTE DISPOSAL PIPE SLOPE
TO DRAIN DOWN THE WASTE & URINE OF CATTLE/ LIVESTOCK
2000mm

150mm Ø SLOPE
1050mm
SEPTIC TANK

1ST FLOOR MN PUMP SLOPE


BORING LOCATION
150mm Ø

2000mm

100mm Ø WASTE WATER STACK


SLOPE

PIPE COVERED WITH GRATINGS


Tubewell

100mm Ø SOIL STACK


50mm Ø VENT STACK
SLOP
E
150m
mØ S
100mm Ø WASTE WATER STACK SIDE- Z
S
50mm Ø VENT STACK
100mm Ø SOIL STACK
SIDE- X

150mm Ø SLOPE

EL ± 0.00
ENTRY
100mmØ VERTICAL PIPE TO DRAIN DOWN THE WASTE & URINE

EL + 900
EL + 900 OF CATTLE/ LIVESTOCK INCLUDING CI GRATING AT THE
OPENING IN 1ST FLOOR SLAB
150mm Ø
R
SLOPE
150mm Ø
150mm Ø SLOPE

EL + 900
EL ± 0.00
ENTRY

EL + 900

SLOPE
38 Ø GI VERTICAL PIPE

SLOPE
FROM HAND P UMP
ENTRY
EL ± 0.00
PIPE COVERED WITH
GRATINGS

R 100mmØ VERTICAL PIPE TO DRAIN DOWN THE WASTE & URINE


OF CATTLE/ LIVESTOCK INCLUDING CI GRATING AT THE
OPENING IN 1ST FLOOR SLAB
S
LAYOUT OF RAIN WATER PIPE LINE , WASTE DISPOSAL

ENTRY
EL + 900 EL ± 0.00
PIPES & SEPTIC TANK OF OPTION-5 (GR. FLOOR)

150mm Ø
NOTE:

SLOPE
(a) SUFFICIENT CLAMP MUST BE PROVIDED.
(b) ALL 100mm Ø RAIN WATER DOWN PIPE OUTLET
S
SLOPE COVERED WITH GRATINGS.
1ST FLOOR MN PUMP

150mm Ø
BORING LOCATION

150mm Ø

SLOPE
SLOPE
1050mm

1050mm
EL + 900
SLOPE
SIDE- Y
150mm Ø SLOPE
R R
S S
SLOPE

SLOPE
150mm Ø

150mm Ø
100mm Ø SOIL STACK

SLOPE

SLOPE
50mm Ø VENT STACK ENTRY
100mm Ø WASTE STACK
EL ± 0.00
PIPE COVERED WITH GRATINGS
Rev. No. Date Description
PROJECT : NAME, TYPE, LOCATION, PACKAGE & SCHOOL CODE : CLIENT : CONSULTANTS : DRAWING TITLE : Drawn by : Md. Golam Hossain
Designed by :
Name : Unique ID :
APPROVED BY :
MULTIPURPOSE DISASTER SHELTER LAYOUT OF RAIN WATER PIPE LINE,WASTE DISPOSAL PIPES Md . Towhid Ahasan
Type : Option -05 School Code :
Line Ministry :
PROJECT(MDSP) Government of & SEPTIC TANK OF OPTION-5 (GR. FLOOR) Checked by :
Upazila : Ministry of LGRD Drg. No. : MDSP/ PD - OPT.05
Funded by World Bank Peoples Republic of Dr. S.M. Parvez Mohit
District : Implementing Agency :Local Govt. Sheet No. : PD - 01 Team Leader Javed Karim
Bangladesh
Package : Engineering Department (LGED) Date : August, 2020 Susil Somasiri Project Director