You are on page 1of 1

SOAK WELL(OPTIONAL)

SEPTIC TANK

PIPE
POSITION OF SUBMERSIBLE


PUMP (OPTIONAL)

150m
POSITION OF SEPTIC TANK (OPTIONAL)
150mm Ø
SLOPE

H G F E
PIPE
D C B A
100mmØ VERTICAL PIPE TO DRAIN DOWN THE WASTE & URINE OF CATTLE/
EL ± 0.00

25 Ø GI RAISING MAIN FROM PIPE COVERED WITH


GRATINGS
LIVESTOCK INCLUDING CI GRATING AT THE OPENING IN 1ST FLOOR SLAB
CATTLE ENTRY

SLOPE
SUBMERSIBLE PUMP

E
SLOP
PIT PIT
PIPE COVERED WITH GRATINGS MASTER PIT
PIT
3'
SLOPE 150mm Ø PIPE SLOPE 150mm Ø PIPE SLOPE 150mm Ø PIPE SLOPE
PIT
PIT
W PIT PIT 150mm Ø PIPE SLOPE
PIT R R S
SLOPE

PIT
PIPE COVERED WITH
GRATINGS R
R 3
GATE VALVE 25mm OVER FLOW PIPE
100mmØ VERTICAL PIPE TO DRAIN DOWN THE WASTE & URINE OF CATTLE/
100mm Ø RAIN WATER DOWN PIPE
100mm Ø RAIN WATER LIVESTOCK INCLUDING CI GRATING AT THE OPENING IN 1ST FLOOR SLAB

2000mm
DOWN PIPE 25mmØ GI PIPE TO CONNECT THE SUBMERSIBLE

100mm Ø RAIN WATER DOWN PIPE


50mm Ø VENT STACK

150mm Ø PIPE
PUMP TO UNDER GROUND WATER TANK
150mm Ø PIPE

ENTRY
2000mm
ENTRY

SLOPE
50m STAIR
mØ GI SU
SLOPE

EL + 900 PPLY PIPE


EL ± 0.00

100mm Ø WASTE WATER STACK


EL ± 0.00 EL + 900
50mm Ø VENT STACK

100mm Ø SOIL STACK


50mm Ø VENT STACK
150mm Ø PIPE
100mm Ø SOIL
W STACK PI
38 Ø
GI H
P E FOR ORIZON

SLOPE
150m
mØ P 100mm Ø WASTE 2ND TA
IPE
SLOPE FLO L & VE
GROUND WATER TANK O R
WATER STACK R H AND TICAL
POSITION OF SEPTIC TANK (OPTIONAL)

(For Detail See Architectiural


& Structural Drawing) PUM
P

PIT
S S
SIDE - X
2
SEPTIC TANK

PIT

W 1ST FLOOR MN PUMP


1ST FLOOR MN PUMP BORING LOCATION 100mmØ VERTICAL PIPE TO DRAIN DOWN THE WASTE & URINE OF CATTLE/ BORING LOCATION SIDE -Y

150mm Ø PIPE
150mm Ø PIPE

LIVESTOCK INCLUDING CI GRATING AT THE OPENING IN 1ST FLOOR SLAB

SLOPE
SLOPE

750 mm

750 mm
EL + 900 SLOPE
600 mm 600 mm
R R 1
SLOPE
PIT

SLOPE 150mm Ø PIPE 150mm Ø PIPE


W W W W W W

PIT
150mm Ø PIPE 150mm Ø PIPE SLOPE SLOPE
PIT PIT PIT PIT PIT PIT

SLOPE
SLOPE
100mm Ø RAIN 100mm Ø RAIN
SLOPE

WATER DOWN PIPE WATER DOWN PIPE


ENTRY ENTRY
EL ± 0.00 EL ± 0.00
NOTE:
SOAK WELL
(OPTIONAL) LAYOUT OF RAIN WATER PIPE LINE , WASTE DISPOSAL (a) SUFFICIENT CLAMP MUST BE PROVIDED.
PIPES & SEPTIC TANK OF OPTION-1 (GR. FLOOR) (b) ALL 100mm Ø RAIN WATER DOWN PIPE OUTLET
COVERED WITH GRATINGS.
Rev. No. Date Description
PROJECT : NAME, UNIQUE ID, TYPE, LOCATION, PACKAGE & SCHOOL CODE : CLIENT : CONSULTANTS : DRAWING TITLE : Drawn by : Md. Golam Hossain
Designed by : APPROVED BY :
MULTIPURPOSE DISASTER SHELTER Name : Unique ID : Md . Towhid Ahasan
Line Ministry :
PROJECT(MDSP) Type : Option -01 School Code : Government of Checked by :
Upazila :
Ministry of LGRD Drg. No. : MDSP/ PD - OPT.01
Funded by World Bank Peoples Republic of Dr. S.M. Parvez Mohit
District : Implementing Agency :Local Govt. Sheet No. : PD - 01 Team Leader Javed Karim
Bangladesh
Package : Engineering Department (LGED) Date : August, 2020 Susil Somasiri Project Director
Printed on Aug 14, 2020