Professional Documents
Culture Documents
BS5950
Client Sattva Calculation By Abhijit Kolhe
Project Name Sattva Knowledge Park Company Name JSSL
Project Ref. Date 04-Mar-19
Slab Ref. Location Hyderabad
Comments
Revision
1 Overall Summary
Construction Stage PASS Max. UF 0.91
Composite Stage PASS Max. UF 0.59
Fire Stage PASS Max. UF 0.96
2 Input Parameters
about:blank 04-Mar-19
Elements Calculation Summary Page 2 of 2
3 Design Criteria
Fire Period 2.0 hrs Fire Analysis Method Fire Engineering
Proportion of Live Load 0% Fire Load Factor 0.80
Live Load Factor 1.60 Dead Load Factor 1.40
Superimposed Load Factor 1.40
4 Construction Stage
Applied Capacity/Limit Unity Factor
Web Shear 12.52 kN/m 60.90 kN/m 0.21
Web Crushing 25.04 kN/m 54.29 kN/m 0.46
Bending (Sagging) 7.71 kNm/m 8.96 kNm/m 0.86
(Note: A 51 % redistribution of hogging is taken into accou nt)
Bending (Hogging) 4.37 kNm/m 6.49 kNm/m 0.67
Bending & Web Crushing 1.13 1.25 0.91
Bending & Shear 0.50 1.00 0.50
Deflection 11.8 mm 19.7 mm 0.60
(Deflection limit is the lesser of Span/180 and 20mm)
5 Composite Stage
Average Composite Inertia 14597200 mm4
Applied Capacity/Limit Unity Factor
Horizontal Shear 22.18 kN/m 37.95 kN/m 0.58
Vertical Shear 29.47 kN/m 54.72 kN/m 0.54
Bending Resistance 26.05 kNm/m 44.13 kNm/m 0.59
Imposed Load Deflection 3.7 mm 10.3 mm 0.36
(Deflection limit is the lesser of Span/350 and 20 mm)
Total Load Deflection 5.8 mm 14.4 mm 0.40
(Deflection limit is the lesser of Span/250 and 20 mm)
Dynamic Deflection 0.34 mm[1]
6 Fire Stage
Applied Capacity/Limit Unity Factor
Moment Resistance 16.19 kNm/m 16.85 kNm/m 0.96
about:blank 04-Mar-19