1. PURPOSE

This standard defines and describes the drawing form requirements (drawing sizes, title block, revision
history block, etc.) for a CNH Industrial Ag/CE supplier drawing form. It also describes the usage and
application of the various elements of the supplier drawing form.

In addition, this standard defines and describes the practices and procedures for using the supplier drawing
form to display a drawing or a document from a supplier for internal use at CNH Industrial Ag/CE.

2. SCOPE

CNH Industrial supplier drawing form is to be used by CNH Industrial Ag/CE, its subsidiaries, joint ventures
and associated design services or agencies when officially releasing a supplier drawing or document.

Significant additions and / or revisions to the text have been highlighted in grey.
Figure captions and table titles for new or revised figures or tables will also be highlighted.

Added multiple sheet text to Section 11.3, Removed


O VIEIRA
35248722 D repeated Engineering Approved Source text from G MORTIER 31OCT16
G MUSSELL
Section 13 replaced with reference to DWGA125
Added Service Parts List definition; Revised Section
7.3.4 to allow CHECKED BY field to be completed by
the system; Expanded Section 7.3.5 regarding
special material notes; Revised Table 3 and Section
G MUSSELL
35241794 C 10 to replace Engineering Parts List by Service Parts G MORTIER 12JUL16
O VIEIRA
List; Added Figure 5 and Figure 6 with sample of
Service Parts List; Revised Section 13 to add
reference to DWGA125, Revised Section 14
Implementation Added Section 15 Legacy Drawings
Revised and Updated to reflect changes to Supplier
drawing forms as released with Pro/Engineer® Creo
2 software. Expanded Section 1 Purpose, Reduced
Section 2 Scope, moved some content to new
Section 5 Conformance, Added Supplier Drawing
Form definition to Section 3.2. Section 5 Drawings
moved to Section 11 and replaced by Conformance
material. Revised Section 6 Drawing Designation
and Size, Updated Section 7 Title Block to align with
Creo 2 title blocks for supplier drawing forms.
Removed Figure 1, Replaced Figure 2 with new
Figure 1, New Figure 2, Updated Table 2 contents,
35199254 B G MUSSELL S HILE 15JUL14
Revised Sections 7.3.1 thru 7.3.3 and added
Sections 7.3.4 thru 7.3.8. Added Table 3, Added
new Section 8, Renumbered Sections 9 and 10.
Added New Figure 4, Documented Location and
Content for Applicable Standards Block and
Engineering Parts List. Section 11 Revised,
removed supplier tag information and added
Drawings (was Section 5). Added Section 11.3
Renumbered Sections 12, 13 as 14, 15. Added new
Section 12 Drawing Content. New Section 13 was
Section 11. Removed old Figures 4 and 6. Updated
Figure 5.
ECO REV CHANGES AUTHOR APPROVED BY DATE
THE INFORMATION HEREON IS THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF CNH INDUSTRIAL N.V. AND/OR
ITS SUBSIDIARIES OR DIVISIONS. ANY USE, EXCEPT THAT FOR WHICH IT MAY BE LOANED, IS PROHIBITED.
UNCONTROLLED COPY When Printed
DWGA101
Drawing Standard 87317383
Rev D
Supplier Drawing Form
Page 2 of 17

1. PURPOSE ............................................................................................................................................ 1
2. SCOPE ................................................................................................................................................. 1
3. ACRONYMS/DEFINITIONS ................................................................................................................. 3
3.1 ACRONYMS.................................................................................................................................. 3
3.2 DEFINITIONS................................................................................................................................ 3
4. RELATED DOCUMENTS ..................................................................................................................... 3
4.1 REFERENCE STANDARDS ......................................................................................................... 3
4.2 REPLACED STANDARDS ............................................................................................................ 3
4.3 ORDER OF PRECEDENCE .......................................................................................................... 3
5. CONFORMANCE ................................................................................................................................. 3
6. DRAWING DESIGNATION AND SIZE ................................................................................................. 4
7. TITLE BLOCK ...................................................................................................................................... 4
7.1 PURPOSE ..................................................................................................................................... 4
7.2 LOCATION AND SIZE ................................................................................................................... 4
7.3 CONTENT ..................................................................................................................................... 5
8. REVISION HISTORY BLOCK ............................................................................................................ 11
8.1 LOCATION .................................................................................................................................. 11
8.2 CONTENT ................................................................................................................................... 11
9. APPLICABLE STANDARDS BLOCK ................................................................................................ 11
9.1 LOCATION .................................................................................................................................. 11
9.2 CONTENT ................................................................................................................................... 12
10. SERVICE PARTS LIST ............................................................................................................... 12
10.1 LOCATION .................................................................................................................................. 12
10.2 CONTENT ................................................................................................................................... 13
11. DRAWINGS ................................................................................................................................ 13
11.1 COMPUTER AIDED DESIGN (CAD) DRAWING ......................................................................... 13
11.2 MANUAL DRAWING ................................................................................................................... 13
11.3 MULTIPLE SHEET DRAWING .................................................................................................... 13
12. DRAWING CONTENT ................................................................................................................. 13
13. ENGINEERING APPROVED SOURCE ...................................................................................... 17
14. IMPLEMENTATION .................................................................................................................... 17
15. LEGACY DRAWINGS ................................................................................................................. 17

THE INFORMATION HEREON IS THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF CNH INDUSTRIAL N.V. AND/OR
ITS SUBSIDIARIES OR DIVISIONS. ANY USE, EXCEPT THAT FOR WHICH IT MAY BE LOANED, IS PROHIBITED.
UNCONTROLLED COPY When Printed
DWGA101
Drawing Standard 87317383
Rev D
Supplier Drawing Form
Page 3 of 17

3. ACRONYMS/DEFINITIONS

3.1 ACRONYMS

Ag/CE—Agricultural and Construction Equipment


CAD—Computer Aided Design
ECO—Engineering Change Order
EPL—Engineering Parts List

3.2 DEFINITIONS

Multiple Sheet Drawing—a drawing consisting of two or more sheets or rolls having the same drawing
number.

Service Parts List—a list of individual parts, components and kits serviced separately showing the
supplier’s part number and correlating CNH Industrial part number. It is not intended to be the Bill of
Material.

Supplier Drawing Form—a standard drawing form that has been modified and includes a title block that
identifies the drawing form as such and contains a notation on restricted circulation or drawing use.

4. RELATED DOCUMENTS

4.1 REFERENCE STANDARDS

CNH DWGA100—Drawing Sheet Sizes and Forms


CNH DWGA112—Multiple Sheet Drawings
CNH DWGA115—Notes on Drawings
CNH DWGA120—Drawing Revision Practices
CNH DWGA125—Document Source Management on Drawings and Parts Categorization
CNH DWGA160—Part Naming Conventions
CNH DWGA300—Abbreviations and Symbols
CNH DWGB001—Drawing Tolerance and Interpretation
CNH ENPH100—Engineering Design Control Locations
CNH ENPH111—Date Format in Engineering Documents and Systems
CNH ENPJ100—Significant Characteristics – Application Procedures

4.2 REPLACED STANDARDS

This standard completes the replacement of New Holland FNHA-3-B-130.00-Drawings of Supplier Parts.

4.3 ORDER OF PRECEDENCE

In the event of a conflict between the text of this standard and the references cited, the text of this standard
shall take precedence.

5. CONFORMANCE

For the purpose of this standard, the term “part” will be inclusive for both parts and assemblies.

The supplier drawing forms defined within this standard will be created and supported on all CNH Industrial
Ag/CE CAD systems and will be supplied when required to any contracted design service or agency.
THE INFORMATION HEREON IS THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF CNH INDUSTRIAL N.V. AND/OR
ITS SUBSIDIARIES OR DIVISIONS. ANY USE, EXCEPT THAT FOR WHICH IT MAY BE LOANED, IS PROHIBITED.
UNCONTROLLED COPY When Printed
DWGA101
Drawing Standard 87317383
Rev D
Supplier Drawing Form
Page 4 of 17

The supplier drawing forms defined within this standard will be created using English text.

The CNH Industrial supplier drawing form is not identified or labeled as being metric or inch.

All dimensions in this standard are in millimetres unless otherwise specified. The forms themselves have
been defined as metric and are based on the International System of Units (SI).

6. DRAWING DESIGNATION AND SIZE

CNH Industrial Ag/CE supplier drawing forms are identified as S2 and S0. Unless otherwise noted, the two
forms must respectively comply with the size and margin requirements for A2 and A0 drawing forms as
described in CNH Drawing Standard DWGA100 – Drawing Sheet Sizes and Forms.

7. TITLE BLOCK

7.1 PURPOSE

The title block provides a uniform arrangement of blocks or fields for recording the general information that
applies to all supplier drawings. See Figure 1.

7.2 LOCATION AND SIZE

The title block is located in the lower right hand corner of the drawing form in alignment with the right hand
and bottom borderlines. See Figure 2. The title block will only be created in the two sizes listed in Table 1
below for corresponding S2 and S0 supplier drawing forms.

TABLE 1: Title Block Sizes


Drawing Form Width mm Length mm
S2 32 263
S0 48 395

FIGURE 1: Example of a CNH Industrial Ag/CE Supplier Drawing Title Block

THE INFORMATION HEREON IS THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF CNH INDUSTRIAL N.V. AND/OR
ITS SUBSIDIARIES OR DIVISIONS. ANY USE, EXCEPT THAT FOR WHICH IT MAY BE LOANED, IS PROHIBITED.
UNCONTROLLED COPY When Printed
DWGA101
Drawing Standard 87317383
Rev D
Supplier Drawing Form
Page 5 of 17

7.3 CONTENT

Table 2 lists the title block information including whether or not it is mandatory. The item number in the
table correlates with the block location within the title block as shown in Figure 1.

TABLE 2: Supplier Drawing Title Block Data

See Figure 2 for the location of the listed items

Item Block Name or Mandatory/Optional at


Block Contents
Number Description the time of release
Fixed Text
SUPPLIER
1 Mandatory Supplier Drawing Heading to designate
DRAWING
and convey supplier drawing form
Fixed Text
Restricted Restrictive Notation to show Circulation Of
2 Circulation Mandatory Drawing Outside CNH Is Prohibited. For
Statement details, see CNH Drawing Standard
DWGA125 Sections 12 and 14.
3 Unlabeled Field Not Applicable Not Applicable
Confidentiality
4 Mandatory Fixed Text
Statement
DOC NO. –
HOM NO. Document Number and Homologation
5 Document Number Optional Number used by some locations
– Homologation Input is formatted as X.XX.XXX-XX
Number)
SIZE/SYS Form size and originating method selected
6 (Drawing Mandatory to make the drawing.
Size/System) See Section 7.3.1.
The scale used to create the CNH
DWG SCALE
7 Mandatory Industrial controlled content.
(Drawing Scale)
See Section 7.3.2.
Two letter code for the location which
DSGN CTRL released the drawing. For a list of location
8 Mandatory
(Design Control) codes, see CNH Engineering Procedure
ENPH100 See Section 7.3.3.
The first initial, space and full last name of
DRAWN BY and the CNH employee who created or is
9 Mandatory responsible for the creation of the drawing
Date
and the date it was created. See Section
7.3.4.

THE INFORMATION HEREON IS THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF CNH INDUSTRIAL N.V. AND/OR
ITS SUBSIDIARIES OR DIVISIONS. ANY USE, EXCEPT THAT FOR WHICH IT MAY BE LOANED, IS PROHIBITED.
UNCONTROLLED COPY When Printed
DWGA101
Drawing Standard 87317383
Rev D
Supplier Drawing Form
Page 6 of 17

See Figure 2 for the location of the listed items

Item Block Name or Mandatory/Optional at


Block Contents
Number Description the time of release
The first initial, space and full last name of
CHECKED BY and who checked or was responsible for the
10 Optional
Date checking of the drawing and the date it
was checked. See section 7.3.4
The first initial, space and full last name of
MATERIAL BY
11 Optional the CNH employee who approved the
and Date
material and the date it was approved.
The first initial, space and full last name of
APPROVED BY
12 Optional the CNH employee who approved the
and Date
drawing and the date it was approved.
Approximate mass (kg) of the part or
APPROXIMATE Mandatory that the field
13 assembly, rounded off to the nearest
MASS display content
single decimal place. See Section 7.3.8.
14 Unlabeled Field Not Applicable Not Applicable
The part number or numbers of a part or
REFERENCE Mandatory that field parts that have a design relationship with
15
PART display content the drawing part number. Default value is
NONE. See Section 7.3.6.
Material designation. See Section 7.3.5.
Mandatory
16 MATERIAL Also, see CNH Drawing Standard
With some exceptions
DWGA125 Sections 10 and 16.
The part description, in English, with a limit
DESCRIPTION
of 40 characters, including spaces. For
17 (Noun Phrase plus Mandatory
details, see CNH Drawing Standard
Modifier)
DWGA160 – Part Naming Conventions.
Optional but The model or project for which the drawing
18 MODEL
Recommended is first released. See Section 7.3.7.
TEAMCENTER Teamcenter Item Identification
19 System Generated
ITEM ID For example CA00AAF00001
TC REV
Teamcenter revision level
20 (Teamcenter System Generated
For example .001, .002, .003
Revision Level)
SHEET n Sheet number for that specific sheet and
21 Mandatory
OF n the total number of drawing sheets
CNH Industrial
22 Mandatory Fixed Text
Logo
Fixed Text
23 CAGE CODE Mandatory Commercial and Government Entity Code
for CNH Industrial

THE INFORMATION HEREON IS THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF CNH INDUSTRIAL N.V. AND/OR
ITS SUBSIDIARIES OR DIVISIONS. ANY USE, EXCEPT THAT FOR WHICH IT MAY BE LOANED, IS PROHIBITED.
UNCONTROLLED COPY When Printed
DWGA101
Drawing Standard 87317383
Rev D
Supplier Drawing Form
Page 7 of 17

See Figure 2 for the location of the listed items

Item Block Name or Mandatory/Optional at


Block Contents
Number Description the time of release
SC CLASS Part Classification based on Significant
(Significant Characteristics on the drawing (CNH0,
24 Mandatory
Characteristic CNH1 or CNH2). For details, refer to CNH
Classification) Engineering Procedure ENPJ100.
Number of Critical Characteristics / Total
CRITICAL/TOTAL number of Significant Characteristics on
25 Mandatory
SC’S the drawing, if one or both are none, enter
zero, e.g. 0/2 or 0/0.
Part number assigned to the drawing
26 PART NUMBER Mandatory
Typically eight characters

Additional information on some specific fields is listed below.

7.3.1 SIZE/SYSTEM (Item 6) – The drawing form size is entered as a two-digit code, e.g. A2 or A0,
followed by a slash and a two- or three-digit code indicating the CAD system generating the drawing, e.g.
PRO for Pro/ENGINEER®, MEX for Microsoft Excel etc. (for additional codes see CNH Drawing Standard
DWGA100). For example, A0/PRO, A2/MEX. The code MNL will be used on manual drawings and RST
on raster generated drawings.

7.3.2 DWG SCALE (Item 7) – The scale of CNH Industrial controlled orthographic views placed on the
drawing is displayed in this field. Additional non-projected views such as Detail, Section and Isometric
views must include their individual scale unless it matches the drawing scale. If no scale is provided the
word NONE must then be entered. The preferred drawing scales are 1:2, 1:3, 1:4, 1:5 and 1:10 for smaller
than full size and 2:1, 3:1, 4:1, 5:1 and 10:1 for larger than full size.

7.3.3 DSGN CTRL (Item 8) – An alpha code used to indicate the design engineering location (per CNH
Engineering Procedure ENPH100 – Engineering Design Control Locations) which initially released or
subsequently revised the drawing. The indicator is linked to the location of the officially released ECO that
releases or revises the drawing.

7.3.4 DRAWN BY, CHECKED BY, APPROVED BY and Date (Items 9, 10 and 12) – The name of the
person who created the drawing is entered using the first initial, space and the full last name, with no
period after the initial. Adding the middle initial is optional, if space permits. The creation date is entered
above the name on the right.

Per CNH Engineering Procedure ENPH111 – Date Format in Engineering Documents and Systems, the
date is presented in a DDMMMYY format that reflects when the drawing was created where the month is
entered in uppercase using the first three characters in the name, e.g. 09SEP01. The same name and
date formatting applies to items 10, 11 and 12.

The DRAWN BY field is a mandatory attribute and is to be completed as follows:

THE INFORMATION HEREON IS THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF CNH INDUSTRIAL N.V. AND/OR
ITS SUBSIDIARIES OR DIVISIONS. ANY USE, EXCEPT THAT FOR WHICH IT MAY BE LOANED, IS PROHIBITED.
UNCONTROLLED COPY When Printed
DWGA101
Drawing Standard 87317383
Rev D
Supplier Drawing Form
Page 8 of 17

1) When the drawing is created by a CNH employee, the first initial (without a period), a space and full
last name of the primary preparer of the drawing must be placed in the DRAWN BY field along with
a date.

2) When the drawing is created by someone other than a CNH employee, the first initial (without a
period), a space and full last name of the CNH employee responsible for the preparation of the
drawing must be placed in the DRAWN BY field along with a date.

The CHECKED BY field is optional, however, if used; the field is to be completed as follows:

1) When the drawing is being checked through the Drawing Checking Application, the CHECKED BY
field will be left blank by designer. The application will enter the first initial (without a period), a
space and full last name of the person checking the drawing along with a date (Note: it is not
mandatory that the checker be a CHN employee).

2) When the drawing is not being checked through the Drawing Checking Application, the first initial
(without a period), a space and full last name of the CNH employee responsible for checking the
drawing must be entered in the CHECKED BY field along with a date.

The APPROVED BY field is optional, however, if used the field is to be completed as follows:

Regardless of who created or checked the drawing, the first initial (without a period), a space and full last
name of the CNH employee responsible for approving the release of the drawing must be entered into the
APPROVED BY field along with a date.

7.3.5 MATERIAL (Item 16) – The base material specification is as follows: Generic Description, CNH
MATXXXX, followed by any grade classifications thereof. For designation of metallic materials, refer to
CNH Material Specification MAT1003. This specification also deals with procedures to be followed when
a) the material description is too long to fit within the field, b) the material is restricted or special and c) an
alternate material needs to be specified.

For materials not covered by CNH Material Specification MAT1003, legacy company specifications (such
as Case MS, FNHA and O&K) or FIAT should be avoided and replaced by a current CNH material
specification. When it is impossible to avoid using legacy company specifications, they are to be listed in
the MATERIAL field.

The material designation could be a part number where the part described by the drawing is made from a
casting, forging or other semi-finished part with its own, unique part number. In such cases, MATERIAL is
not to be filled with a part number; but a material note as defined within CNH Drawing Standard DWGA115
– Notes on Drawings must be used.

The user may fill this field using the special notes below:
• NOT APPLICABLE
This is used when a material is not applicable, for example, where it is not meaningful to provide a
generic material description.
• SEE NOTES
This note is used when the specification is displayed by means of a material note as defined by
CNH Drawing Standard DWGA115.
• SEE CHART
This note is used when the specification is displayed by means of a chart in the body of drawing.

THE INFORMATION HEREON IS THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF CNH INDUSTRIAL N.V. AND/OR
ITS SUBSIDIARIES OR DIVISIONS. ANY USE, EXCEPT THAT FOR WHICH IT MAY BE LOANED, IS PROHIBITED.
UNCONTROLLED COPY When Printed
DWGA101
Drawing Standard 87317383
Rev D
Supplier Drawing Form
Page 9 of 17

If none of the previous paragraphs apply to a part or an assembly, then a brief, generic description of the
primary material(s) used for the part, e.g. STEEL, PLASTIC, ALUMINUM, etc. must be placed in the
MATERIAL field.

The use of the word PURCHASED as a material description is not allowed.

7.3.6 REFERENCE PART (Item 15)

It is mandatory that the REFERENCE PART field display content If the designer fails to enter any
reference part information he or she is prompted during image creation to either display appropriate
reference part information or the word NONE in the field. When revising a drawing, the designer must edit
or purge default REFERENCE PART text as needed to remove any ambiguity.

The REFERENCE PART field displays the part number of a part that has a design relationship with the part
number shown in the lower right hand corner of the drawing.

This design relationship is typically based on similarity in form (for example, right hand – left hand) but it
may be based on function, tooling, manufacturability, cost, material or it may be based on recording the
part number(s) of the item(s) being replaced by the new part number in at least one application.

Multiple part numbers may be displayed. Multiple part numbers must be separated by commas and not
spaces or any other characters.

If information exceeds allotted space then SEE NOTE n must be shown in this field and a NOTE n which
contains the reference part information must be added to the drawing.

For a full understanding of the impact on the Bill of Material and disposition of any replaced part numbers
listed in the REFERENCE PART field, internal users of the drawing must refer to the Engineering Change
Order (ECO) listed in the revision history portion of the drawing.

REFERENCE PART
88888888,87654321,12345678

The designer must use caution when revising the reference part information since this information is now
synched with Engineering Central. This is especially true when a multiple part number drawing such as
painted parts are involved.

When adding an additional part number to an existing group, the designer must determine if the initial
reference information is still appropriate or should it be revised to reference a different part resulting in a
corresponding update in Engineering Central.

7.3.7 MODEL (Item 18)

Model information is optional but when used the model number of the product that the drawing is initially
being released on is placed in this field. If the model number is not known, the user may place a project
designation into this field. If more than one model or a model series, for example E-SERIES CHEX, is
affected the designer must select a specific model for this field, typically this is the first model on which the
item is used.

7.3.8 APPROXIMATE MASS (Item 13)

It is mandatory that the APPROXIMATE MASS field display content.


THE INFORMATION HEREON IS THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF CNH INDUSTRIAL N.V. AND/OR
ITS SUBSIDIARIES OR DIVISIONS. ANY USE, EXCEPT THAT FOR WHICH IT MAY BE LOANED, IS PROHIBITED.
UNCONTROLLED COPY When Printed
DWGA101
Drawing Standard 87317383
Rev D
Supplier Drawing Form
Page 10 of 17

If the designer fails to enter an Approximate Mass value, the default value 0 kg will be displayed.

For further details, see CNH Drawing Standard DWGA100, Appendix A.

FIGURE 2: Example of a Supplier Drawing Title Block, Revision History Block and Applicable
Standards Block

TABLE 3: Revision History Block, Applicable Standards Block and Engineering Parts List Data

ENTRIES IN THE REVISION HISTORY BLOCK - See Figure 3


ECO (8 character) Mandatory Engineering Change Order (ECO) number.
REV (2 character) Mandatory Drawing Revision Level
CHANGES Details of changes made to the drawing, with zone references
(variable character Mandatory where necessary. For more details, see CNH Drawing Standard
count) DWGA120 – Drawing Revision Practices.
The first initial, space and full last name of the CNH employee
BY (13 character) Mandatory who changed or is responsible for the drawing change and the
date it was changed.
DATE Date the change was recorded (format DDMMMYY).
Mandatory
(7 character) See DRAWN BY & Date in title block for format.
ENTRIES IN THE APPLICABLE STANDARDS BLOCK - See Figure 4
STANDARD Referenced Standard Number(s). Mandatory text DWGB001 is
Mandatory
(12 character) displayed on the first line.
DESCRIPTION The title of the Standard(s) referenced. Approved abbreviations
Mandatory
(30 character) per CNH Drawing Standard DWGA300 are permitted.
ENTRIES IN THE SERVICE PARTS LIST
SUPPLIER P/N The supplier part number assigned to the item related to CNH
Mandatory
(16 character) Industrial Part Number
ITEM (4 character) Mandatory A listing number given to each unique part in an assembly.
QUANTITY
Mandatory The total amount of the item used in that assembly.
(8 character)
The unit of measurement in which the item is measured, e.g.
U/M (3 character) As required by
litre, kg, etc. When left blank a default value of “Piece” is
Unit Of Measure the type of part
assigned, Not required for regular component parts.
THE INFORMATION HEREON IS THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF CNH INDUSTRIAL N.V. AND/OR
ITS SUBSIDIARIES OR DIVISIONS. ANY USE, EXCEPT THAT FOR WHICH IT MAY BE LOANED, IS PROHIBITED.
UNCONTROLLED COPY When Printed
DWGA101
Drawing Standard 87317383
Rev D
Supplier Drawing Form
Page 11 of 17

PART NUMBER The CNH Industrial part number assigned to the item related to
Mandatory
(16 character) Supplier Part Number
DESCRIPTION Description of the item, not to exceed a total of 40 characters,
Mandatory
(40 character) including commas and spaces.

FIGURE 3: Example of a Drawing Revision History Block

8. REVISION HISTORY BLOCK

The Revision History Block as defined in CNH Drawing Standard DWGA100 is required. See Figure 3.

8.1 LOCATION

The Revision History Block is a single block located at the bottom of the drawing and is the same height as
the title block. The right edge of the Revision History Block aligns with the left edge of the title block and
the bottom edge aligns with the bottom borderline.

On a multiple sheet drawing, the Revision History Block is displayed on every sheet.

8.2 CONTENT

The Revision History Block consists of five fields as shown in Figure 3. Table 3 lists the informational
requirements and the minimum number of characters for a Revision History Block. The CHANGES field is
not limited to a specific number of characters but is determined by the available amount of space on the
drawing form after the title block and all other related fields have been created.

9. APPLICABLE STANDARDS BLOCK

The Applicable Standards Block as defined in CNH Drawing Standard DWGA100 is required to be on the
Supplier Drawing Form and may not be removed. See Figure 4.

9.1 LOCATION

THE INFORMATION HEREON IS THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF CNH INDUSTRIAL N.V. AND/OR
ITS SUBSIDIARIES OR DIVISIONS. ANY USE, EXCEPT THAT FOR WHICH IT MAY BE LOANED, IS PROHIBITED.
UNCONTROLLED COPY When Printed
DWGA101
Drawing Standard 87317383
Rev D
Supplier Drawing Form
Page 12 of 17

On both S2 and S0 drawing forms, the right edge of the Applicable Standards Block aligns with the left
edge of the Revision History Block and the bottom edge aligns with the bottom borderline.

The Applicable Standards Block is displayed on Sheet 1 and only Sheet 1 on a multiple sheet drawing.

FIGURE 4: Example of an Applicable Standards Block

9.2 CONTENT

The Applicable Standards Block consists of two fields as shown in Figure 4. The two fields are
STANDARD and DESCRIPTION. Table 3 lists the informational requirements and the minimum number of
characters for the Applicable Standards Block.

Per CNH Drawing Standard DWGB001 - Drawing Tolerance and Interpretation, the first line of the
Applicable Standards Block will display DWGB001 DRAWING TOL AND INTERPRETATION. See CNH
Drawing Standard DWGA100 for additional content requirements.

10. SERVICE PARTS LIST

Where some or all of the components of a purchased part will be serviced separately, a list of parts
showing the supplier’s part number and correlating CNH Industrial part number is to be created. For
further details, see CNH Drawing Standard DWGA125 – Document Source Management on Drawings and
Parts Categorization.

To support the display of service parts a Service Parts List as described below may be placed on the
drawing.

10.1 LOCATION

On a S2 size supplier drawing form the Service Parts List is 235 mm wide. To accommodate an increase
in the size of the text, the list is enlarged to 286 mm on a S0 size supplier drawing form. The right edge of
Service Parts List is aligned with right side border of the drawing form and unless otherwise specified the
bottom edge of the list is aligned with the top edge of the title block. See Figures 5 and 6.

FIGURE 5: Example of a Service Part List in a S2 Supplier Drawing Form

THE INFORMATION HEREON IS THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF CNH INDUSTRIAL N.V. AND/OR
ITS SUBSIDIARIES OR DIVISIONS. ANY USE, EXCEPT THAT FOR WHICH IT MAY BE LOANED, IS PROHIBITED.
UNCONTROLLED COPY When Printed
DWGA101
Drawing Standard 87317383
Rev D
Supplier Drawing Form
Page 13 of 17

FIGURE 6: Example of a Service Part List in a S0 Supplier Drawing Form

10.2 CONTENT

The Service Parts List consists of six fields. The six fields are, SUPPLIER P/N, ITEM (Item Number),
QUANTITY, U/M (Unit of Measure), PART NUMBER, and DESCRIPTION. Table 3 lists the informational
requirements and the minimum number of characters for a Service Parts List.

11. DRAWINGS

11.1 COMPUTER AIDED DESIGN (CAD) DRAWING

A CAD drawing is made by placing the suppliers electronically transferred drawing onto a supplier drawing
form as defined within this document. To support this activity, the supplier drawing forms must be made
available on all CNH Industrial Ag/CE CAD systems and said forms will be supplied when required to any
CNH Industrial Ag/CE contracted design service or agency.

A CAD drawing may or may not have a CAD model. If a model is available, an ISO view of the model will
be shown. If there is no model, a note indicating that the drawing is only a 2D representation must be
added.

11.2 MANUAL DRAWING

Creating manual drawings, as a rule, is not encouraged. A manual drawing may be made by placing a
supplier’s print on a printed copy of the supplier drawing form. SIZE/SYS must indicate that the released
drawing is A2/MNL or A0/MNL, no other sizes are allowed. The past practice of attaching a “supplier tag”
to a supplier print has been eliminated and is no longer permitted.

11.3 MULTIPLE SHEET DRAWING

Where the need to convey additional information requires it, a multiple sheet drawing may be made. The
information is placed on a standard drawing form as defined by CNH Drawing Standard DWGA100. CNH
Industrial Ag/CE supplier drawing form(s) may be attached to an existing part drawing or may be used to
create a new multiple sheet drawing as needed. Wherever practical, all sheets are to be the same size.
The revision level, assigned by CNH Industrial Ag/CE, will be the same for all sheets. See CNH Drawing
Standard DWGA112 – Multiple Sheet Drawings, for more information.

12. DRAWING CONTENT


As previously described in Section 7 Title Block, the approximate mass value of the part must be
determined and displayed in kilograms in the title block. For further details, see CNH Drawing Standard
DWGA100.

Supplier dimensions must not be modified but are to be maintained and displayed in their native units of
measurement.
Supplier tolerance information takes precedence over CNH Industrial Ag/CE tolerance standards.

THE INFORMATION HEREON IS THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF CNH INDUSTRIAL N.V. AND/OR
ITS SUBSIDIARIES OR DIVISIONS. ANY USE, EXCEPT THAT FOR WHICH IT MAY BE LOANED, IS PROHIBITED.
UNCONTROLLED COPY When Printed
DWGA101
Drawing Standard 87317383
Rev D
Supplier Drawing Form
Page 14 of 17

The placing of any additional information such as inspection dimensions, tolerances, notes, etc. on or
within the supplier’s drawing is not permitted. Any additional information will be placed within the CNH
Industrial Supplier Drawing form but outside of the border of the supplier’s drawing or a multiple sheet
drawing may be created as defined above.

For additional information on notes, see CNH Drawing Standard DWGA115.


For additional information on content, see CNH Drawing Standard DWGA125

THE INFORMATION HEREON IS THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF CNH INDUSTRIAL N.V. AND/OR
ITS SUBSIDIARIES OR DIVISIONS. ANY USE, EXCEPT THAT FOR WHICH IT MAY BE LOANED, IS PROHIBITED.
UNCONTROLLED COPY When Printed
DWGA101
Drawing Standard 87317383
Rev D
Supplier Drawing Form
Page 15 of 17

FIGURE 7: Example of an S2 Supplier Drawing Form

THE INFORMATION HEREON IS THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF CNH INDUSTRIAL N.V. AND/OR
ITS SUBSIDIARIES OR DIVISIONS. ANY USE, EXCEPT THAT FOR WHICH IT MAY BE LOANED, IS PROHIBITED.
UNCONTROLLED COPY When Printed
DWGA101
Drawing Standard 87317383
Rev D
Supplier Drawing Form
Page 16 of 17

FIGURE 8: Example of an S0 Supplier Drawing Form

THE INFORMATION HEREON IS THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF CNH INDUSTRIAL N.V. AND/OR
ITS SUBSIDIARIES OR DIVISIONS. ANY USE, EXCEPT THAT FOR WHICH IT MAY BE LOANED, IS PROHIBITED.
UNCONTROLLED COPY When Printed
DWGA101
Drawing Standard 87317383
Rev D
Supplier Drawing Form
Page 17 of 17

13. ENGINEERING APPROVED SOURCE

Refer to DISPLAYING APPROVED SOURCES in CNH Drawing Standard DWGA125 for guidance on how
to display approved sources.

14. IMPLEMENTATION

All CNH Industrial Ag/CE drawings first revision published on the corporate drawing viewer system after the
Engineering Release date of this revision of CNH Drawing Standard DWGA101 must be drawn in
accordance with this document.

All CNH Industrial Ag/CE drawings released prior to the publication and adoption of this standard; need not
be modified but can retain their original drawing size and format.

All revised CNH Industrial Ag/CE drawings are to follow instructions as provided in CNH Drawing Standard
DWGA120 – Drawing Revision Practices.

It is in the best interest of CNH Industrial to implement recommended practices as these may become
mandatory in future revisions of this standard, whereas, alternate practices may no longer be allowed.

15. LEGACY DRAWINGS

Legacy CNH Industrial Ag/CE drawings may have any one of several former company drawing formats
associated with them. These formats need not be replaced with the ones defined by this standard unless
there are reasons to do so as judged by Product Engineering or imposed by CNH Industrial systems and
tools as part of release process.

When a legacy format is replaced, the designer needs to pay attention to critical information displayed in
the title block such as General Tolerances, Drawing View Projection Standards, Material Specifications,
Drawing Revision Information, etc. The designer must make and record any changes, as needed and
unless intentionally revised must make sure that the original form, fit and function are not affected.
Engineering Standards should be consulted whenever there is a question about interpretation of legacy
data, drawing standards, etc.

THE INFORMATION HEREON IS THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF CNH INDUSTRIAL N.V. AND/OR
ITS SUBSIDIARIES OR DIVISIONS. ANY USE, EXCEPT THAT FOR WHICH IT MAY BE LOANED, IS PROHIBITED.
UNCONTROLLED COPY When Printed

You might also like