IS 1608: 2005

ISO 6892: 1998

Finally. it should be appreciated that when suitable reference materials become avaiblable they will offer
a useful means of measuring the total measurement uncertainty on any given testing machine including
the influence of grips, bending, etc. which at present have not been quantified.

~53688 , 8518

350 I "'--l "-. . . -------,

i
I

! I
340

330

280

270

260

I
-3 -2 -1 o
tg 10 plastic strain rate per minute

Key

I Maximum expected error in stress

Figure J.1 - Variation of lower yield strength (Nel ) at room temperature as a function
of strain rate, for plate steel [6J

37