You are on page 1of 1

Quality Observation/Concern Report

(Issued by AEL- FQA To M/s Vivir Construction)

QA-Observation Date: 13-Aug-22 Contractor Name M/s- Vivir Construction.


Quality Observation No: AEL/CIVIL/140 Sub-Contractor Name: M/s- Vivir Construction.
Project Name: Gumga AVM 1BHK Discipline: CIVIL
S.O N.O: 8130005169 Area Of Inspection/ Location/ Equipment: Ground floor roof slab reinforcement
Status Open FQP NO & Clause No/Ref. Drawing No. FQP NO. AEL/VIVIR/CIVIL/AEL-AVM/01
Category: II. Medium Severity Test Perform: Visual
Description of Observation Root Cause (if Any)

During site inspection it is observed that,


1. Beam bottom and sides reinforcement cover not maintained particular area.
2.All Slab reinforcement crank bars not in straight (miss align).
3. Particular beam reinforcement bars development length not followed as per drawing.
Lake of supervision
4.Slab reinforcement bars some portion binding balance .
5. Particular room slab shuttering level 10mm deviation found.
6. Particular columns inside loose materials and cleaning not done proper.
7. Column all sides shuttering gap found.

Photographs During Inspection

AEL FQA AEL- Project Engineer Submitted To:


Name Name: Mr. Sandip ji.
Kishore Kunal /V.Lakshmanan Kaushik Mishra

Signature Date: 13-Aug-22

Date Agency: M/s- Vivir Construction.


13-Aug-22 13-Aug-22

*This is a computer generated report doesn’t need a physical signature


Format No. AEL/FQA/QOR-01 Rev.0

You might also like