The document contains parameters for configuring an inverter drive. It lists 60 parameters numbered no-00 through no-59 with descriptions of each parameter's function and default value. The parameters control functions like operation mode, acceleration and deceleration times, frequency limits, and I/O configurations.
The document contains parameters for configuring an inverter drive. It lists 60 parameters numbered no-00 through no-59 with descriptions of each parameter's function and default value. The parameters control functions like operation mode, acceleration and deceleration times, frequency limits, and I/O configurations.
The document contains parameters for configuring an inverter drive. It lists 60 parameters numbered no-00 through no-59 with descriptions of each parameter's function and default value. The parameters control functions like operation mode, acceleration and deceleration times, frequency limits, and I/O configurations.
no-01 operation mode 0011 01 : enable basic motor no-02 max output frequency 060.0 02 : enable basic applica no-03 max voltage 200.0 03 : enable advanced ap no-04 max voltage output frequency 060.0 06 : all fault record are c no-05 mid output frequency 1.5 Hz 08 : initializes inverter b no-06 mid voltage output frequency 12.0 V 09 : initializes all control no-07 min output frequency 1.5 Hz no-01 bit 0 : frequency ref. fro no-08 min voltage output frequency 12.0 V bit 1 : start/stop from co no-09 acceleration time 1 10.0 bit 2 : deceleration (0) / no-10 deceleration time 1 10.0 no-11 acceleration time 2 10.0 no-12 deceleration time 3 10.0 no-13 frequency reference 1 0.0 no-14 frequency reference 2 0.0 no-15 frequency reference 3 0.0 no-16 frequency reference 4 0.0 no-17 jog frequency reference 6.0 no-18 bit 0 : electronic therma no-18 motor type 0000 bit 1 : standard motor (0 no-19 motor rated current bit 2 : standard ratings ( no-20 reverse rotation prevention 0000 no-20 bit 0 : reverse rotation p no-21 S-curve pattern accel/decel 0000 bit 4 : stall (0) / no stall no-22 frequency reference gain 1.00 no-21 00 : S-curve section not no-23 frequency reference bias 00.00 (bit 3 & 4) 01 : S-curve section 0.2 s no-24 output frequency upper limit 100% 10 : S-curve section 0.5 s no-25 output frequency lower limit 0 11 : S-curve section 1.0 s no-26 DC injection braking current 50% (bit 2) output frequency (0) / c no-27 DC injection braking during stop 0.5 s no-28 DC injectionbraking at start 0.0 s no-29 automatic torque boost gain 1.0 no-32 & 33 00 operation level for stall prevention during no-30 170% 01 acceleration
no-31 operation level for stall prevention during run 160% 02
no-32 multifunction contact input (terminal 4) 01 03 no-33 multifunction contact input (terminal 5) 03 04 no-34 multifunction photocoupler output (terminal 130 05 no-35 multifunction photocoupler output (terminal 141 06 no-36 frequency detection level 0.0 07 no-37 overtorque detection selection 0000 08 no-38 overtorque detection level 160% 09 no-39 overtorque detection time 0.1 s 10 no-40 the inverter carrier frequency 04 11 no-41 not used 12 no-42 not used 13 no-43 not used no-34 & 35 0 no-44 not used 1 no-45 analog monitor gain 1.00 2 automatic decrease stall prevention level no-46 0000 3 during accel in constant HP (kW) Area no-47 fault retry selection 0 4 no-48 fault record 5 no-49 PROM no no-37 bit 0 : no overtorque (0) no-50 prohibited frequency 1 0.0 Hz bit 1 : detection only du no-51 prohibited frequency 2 0.0 Hz bit 2 : continues operati no-52 prohibited frequency 3 0.0 Hz no-40 01 : 2.5 kHz or less (100 no-53 prohibited width 1.0 Hz 02 : 5 kHz or less (up to 1 no-54 speed search operation level 150% 04 : 10 kHz or less (up to no-55 min. baseblock time 0.5 s 06 : 15 kHz or less (up to no-46 no-56 V/F during speed search 100% bit 0 : no continous (0) / no-57 slip compensation gain 0.0% bit 3 : auto lowering disa no-58 motor no-load current 30% no-59 slip compensation primary delay time 2.0s 00 : all functions and application are write protected. only write 00 01 : enable basic motor function. read and write 00 to 19 02 : enable basic applications. read and write 00 to 29 03 : enable advanced applications. read and write 00 to 59 06 : all fault record are cleared 08 : initializes inverter by restoring all settings and terminal functions to factory settings 09 : initializes all control constans. terminal functions are all set to 3-wire sequence bit 0 : frequency ref. from control circuit (0) / digital operator (1) bit 1 : start/stop from control circuit (0) / digital operator (1) bit 2 : deceleration (0) / coast (1) to a stop
bit 1 : standard motor (0) / exclusive-use motor bit 2 : standard ratings (0) / short-term ratings bit 0 : reverse rotation possible (0) / impossible (1) bit 4 : stall (0) / no stall (1) prevention during deceleration 00 : S-curve section not provided 01 : S-curve section 0.2 sec 10 : S-curve section 0.5 sec 11 : S-curve section 1.0 sec output frequency (0) / current (1) monitor
forward / reverse command
external fault (NO contact input)
external fault (NC contact input)
multi-step speed reference 1 multi-step speed reference 2 Jog command accel/decel time select external baseblock (NO contact input) external baseblock (NC contact input) search command from max frequency search command set frequency accel/decel hold command local/remote selection option/inverter selection in operation agreed frequency zero speed output frequency more than frequency detection level overtorque detected operation mode bit 0 : no overtorque (0) / overtorque (1) detection bit 1 : detection only during agreed speed (0) / during running (1) bit 2 : continues operation after (0) / output shut off at (1) overtorque detection 01 : 2.5 kHz or less (100 m or more) 02 : 5 kHz or less (up to 100 m) 04 : 10 kHz or less (up to 50 m) 06 : 15 kHz or less (up to 30 m) bit 0 : no continous (0) / continous (1) operation after momentary power loss bit 3 : auto lowering disabled (0) / enabled (1)