1 Scullary
Qty of Air in CFM=Room Volume(ft.) xRoom height(ft.)ACPH(Air
x changes as per standerd) /60
Qty of Air in CFM= 323 12 20 /60 1292 CFM
which is Equivqlqnt to = 1500 CFM
2 kitchen
Qty of Air in CFM=Room Volume(ft.) xRoom height(ft.)ACPH(Air
x changes as per standerd) /60
Qty of Air in CFM= 366 12 25 /60 1830 CFM
which is Equivqlqnt to = 2000 CFM
3 Toilet 1
Qty of Air in CFM=Room Volume(ft.) xRoom height(ft.)ACPH(Air
x changes as per standerd) /60
Qty of Air in CFM= 48 12 15 /60 144 CFM
which is Equivqlqnt to = 150 CFM
4 Bath Room
Qty of Air in CFM=Room Volume(ft.) xRoom height(ft.)ACPH(Air
x changes as per standerd) /60
Qty of Air in CFM= 65 12 15 /60 195 CFM
which is Equivqlqnt to = 200 CFM
5 Pantry
Qty of Air in CFM=Room Volume(ft.) xRoom height(ft.)ACPH(Air
x changes as per standerd) /60
Qty of Air in CFM= 81 12 12 /60 194.4 CFM
which is Equivqlqnt to = 200 CFM
6 Toilet 2
Qty of Air in CFM=Room Volume(ft.) xRoom height(ft.)ACPH(Air
x changes as per standerd) /60
Qty of Air in CFM= 60 12 15 /60 180 CFM
which is Equivqlqnt to = 200 CFM
First floor
1 Master Bed room
Qty of Air in CFM=Room Volume(ft.) xRoom height(ft.) xACPH(Air changes as per standerd)
/60
Qty of Air in CFM= 194 12 10 /60 388 CFM
which is Equivqlqnt to = 400 CFM
2 Bath Room 1
Qty of Air in CFM=Room Volume(ft.) xRoom height(ft.) xACPH(Air changes as per standerd)
/60
Qty of Air in CFM= 65 12 15 /60 195 CFM
which is Equivqlqnt to = 200 CFM
3 Bath Room 2
Qty of Air in CFM=Room Volume(ft.) xRoom height(ft.) xACPH(Air changes as per standerd)
/60
Qty of Air in CFM= 65 12 15 /60 195 CFM
which is Equivqlqnt to = 200 CFM
4 Bath Room 3
Qty of Air in CFM=Room Volume(ft.) xRoom height(ft.) xACPH(Air changes as per standerd)
/60
Qty of Air in CFM= 65 12 15 /60 195 CFM