You are on page 1of 3

D6N XL, D/S, LGP TRACK-TYPE TRACTOR AKM00001-UP (MACHINE) POWE...

Página 1 de 3

Cerrar SIS

Pantalla anterior

Producto: TRACK-TYPE TRACTOR


Modelo: D6N TRACK-TYPE TRACTOR AKM00401
Configuración: D6N XL, D/S, LGP TRACK-TYPE TRACTOR AKM00001-UP (MACHINE) POWERED BY 3126B Engine

Localización y Solución de Problemas


561N, 572R and 572R Series II Pipelayers and D10R, D11R, D5M, D5N, D6M, D6N, D6R,
D6R Series II, D7R, D7R Series II and D8R Series II Track-Type Tractors Power Train
Electronic Control System
Número de medio -SENR8367-18 Fecha de publicación -01/01/2012 Fecha de actualización -20/01/2012

i01785873

MID 113 - CID 0168 - FMI 03


SMCS - 1406-038

Conditions Which Generate This Code:

This diagnostic code is recorded when the system voltage is greater than 32.5 DCV. The solenoids
may be damaged if the voltage remains high for an extended period of time.

The possible causes of this diagnostic code are listed below:

• A charging system component has failed.

• The harness wiring has failed.

• The ECM has failed. This is unlikely.

Test Step 1. CHECK THE CHARGING SYSTEM.

A. Turn the key start switch to the ON position.

B. Access Service Mode. Place CID 0168 FMI 03 on hold. See Testing and Adjusting, "Using
Caterpillar Monitoring System to Determine Diagnostic Codes".

C. Observe the status of the diagnostic code indicator.

Expected Result:

The diagnostic code indicator shows "SERV CODE".

Results:

• YES - The diagnostic code indicator shows "SERV CODE". Proceed to Test Step 3.

https://127.0.0.1:444/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/si... 23/03/2021
D6N XL, D/S, LGP TRACK-TYPE TRACTOR AKM00001-UP (MACHINE) POWE... Página 2 de 3

• NO - The diagnostic code indicator does not show "SERV CODE". Proceed to Test Step 2.

Test Step 2. CHECK THE CHARGING SYSTEM.

A. Start the engine.

B. Access Service Mode. Place CID 0168 FMI 03 on hold.

C. Observe the status of the diagnostic code indicator.

Expected Result:

The diagnostic code indicator shows "SERV CODE".

Results:

• YES - The diagnostic code indicator shows "SERV CODE".

Repair: The charging system is charging at an excessive voltage. Check the charging system.
See System Operation, SENR2947, "Starting and Charging System".

Stop.

• NO - The diagnostic code indicator does not show "SERV CODE".

Repair: There is no problem at this time. Watch for a recurrence.

Stop.

Test Step 3. CHECK THE BATTERY VOLTAGE.

A. The engine is stopped. At the battery, measure the voltage.

Expected Result:

The voltage is less than 32.5 VDC.

Results:

• YES - The voltage is less than 32.5 VDC.

Repair: Exit this procedure and perform the diagnostic code procedure again. If the problem
persists, the ECM may have failed. Prior to replacing the ECM, always contact your
dealership's Technical Communicator for possible consultation with Caterpillar. This
consultation may greatly reduce repair time. If the cause of the diagnostic code is not found,
replace the power train ECM. See the Testing and Adjusting, "Electronic Control Module
(ECM) - Replace".

Stop.

• NO - The voltage is not less than 32.5 VDC.

https://127.0.0.1:444/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/si... 23/03/2021
D6N XL, D/S, LGP TRACK-TYPE TRACTOR AKM00001-UP (MACHINE) POWE... Página 3 de 3

Repair: The charging system is charging at an excessive voltage. Check the charging system.
See System Operation, SENR2947, "Starting and Charging System".

Stop.

Copyright 1993 - 2021 Caterpillar Inc. Tue Mar 23 14:01:44 CST 2021
Todos los derechos reservados.
Red privada para licenciados del SIS.

https://127.0.0.1:444/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/si... 23/03/2021