𝟐

𝑽𝒄 = 𝟎. 𝟏𝟕 (𝟏 + ) 𝝀 √𝒇′𝒄 𝒃𝒐 𝒅
𝜷
𝜶𝒔 𝒅
𝑽𝒄 = 𝟎. 𝟎𝟖𝟑 ( + 𝟐 ) 𝝀 √𝒇′𝒄 𝒃𝒐 𝒅
𝒃𝒐

𝑽𝒄 = 𝟎. 𝟑𝟑 𝝀 √𝒇′𝒄 𝒃𝒐 𝒅
4 𝐴𝑠𝑝 𝐴𝑔 𝑓𝑐′
∴ ≥ 0.45 ( − 1)
𝑑𝑐 𝑠 𝐴𝑐 𝑓𝑦
𝑬𝒄𝒃 𝑰𝒃 𝑬𝒄𝒃 𝑪 𝒙 𝒙𝟑 𝒚
𝜶𝒇 = ; 𝜷𝒕 = ; 𝑪 = ∑(𝟏 − 𝟎. 𝟔𝟑 )
𝑬𝒄𝒔 𝑰𝒔 𝟐𝑬𝒄𝒔 𝑰𝒔 𝒚 𝟑

𝒌𝒍𝒖 𝑴𝟏 𝑴𝟏 𝑰
For braced columns ≤ 𝟑𝟒 − 𝟏𝟐 ; 𝟑𝟒 − 𝟏𝟐 ≤ 𝟒𝟎 ; 𝒓=√
𝒓 𝑴𝟐 𝑴𝟐 𝑨

𝒌𝒍𝒖
For unbraced columns ≤ 𝟐𝟐
𝒓

𝑴𝒄 = 𝜹𝒏𝒔 𝑴𝟐 ; 𝑴𝟐,𝒎𝒊𝒏 ≥ 𝑷𝒖 (𝟎. 𝟎𝟏𝟓 + 𝟎. 𝟎𝟑𝒉)


𝐸𝐼
𝑪𝒎 𝑴𝟏 𝝅𝟐 𝑬𝑰 ∑ 𝑜𝑓 𝑐𝑜𝑙𝑢𝑚𝑛𝑠
𝑙𝑐
𝜹𝒏𝒔 = 𝒑𝒖 ≥ 𝟏. 𝟎 ; 𝑪𝒎 = 𝟎. 𝟔 + 𝟎. 𝟒 ≥ 𝟎. 𝟒 ; 𝑷𝒄 = ; ;𝜓 = 𝐸𝐼
𝟏− 𝑴𝟐 (𝒌𝒍𝒖 )𝟐 ∑ 𝑜𝑓 𝑓𝑙𝑜𝑜𝑟 𝑏𝑒𝑎𝑚𝑠
𝟎.𝟕𝟓𝒑𝒄 𝑙𝑐

𝟎.𝟐𝑬𝒄 𝑰𝒈 + 𝑬𝒔 𝑰𝒔𝒆 𝟎.𝟒𝑬𝒄 𝑰𝒈 𝑼𝒍𝒕𝒊𝒎𝒂𝒕𝒆 𝒔𝒖𝒔𝒕𝒂𝒊𝒏𝒆𝒅 𝒂𝒙𝒊𝒂𝒍 𝒍𝒐𝒂𝒅


𝑬𝑰 = ; 𝑬𝑰 = ; 𝜷𝒅𝒏𝒔 = ; 𝑬𝒄 = 𝟒𝟕𝟎𝟎√𝒇′𝒄
𝟏+𝜷𝒅𝒏𝒔 𝟏+𝜷𝒅𝒏𝒔 𝒖𝒍𝒕𝒊𝒎𝒂𝒕𝒆 𝒕𝒐𝒕𝒂𝒍 𝒂𝒙𝒊𝒂𝒍 𝒍𝒐𝒂𝒅

∑𝑷𝒖 𝜟𝟎
𝑸= ; 𝑴𝟏 = 𝑴𝟏𝒏𝒔 + 𝜹𝒔 𝑴𝟏𝒔 ; 𝑴𝟐 = 𝑴𝟐𝒏𝒔 + 𝜹𝒔 𝑴𝟐𝒔
𝑽𝒖𝒔 𝒍𝒄
𝟏 𝟏
𝜹𝒔 = ∑ 𝑷𝒖 ≥𝟏 ; 𝜹𝒔 = ≥𝟏
𝟏− 𝟏−𝑸
𝟎.𝟕𝟓∑𝑷𝒄

a. For 𝟎. 𝟐 < 𝜶𝒇𝒎 ≤ 𝟐. 𝟎, shall not be less than:


𝒇𝒚
𝒍𝒏 (𝟎. 𝟖 + )
𝒉= 𝟏𝟒𝟎𝟎 ≥ 𝟏𝟐𝟓 𝒎𝒎
𝟑𝟔 + 𝟓 𝜷 (𝜶𝒇𝒎 − 𝟎. 𝟐)
b. For 𝜶𝒇𝒎 > 𝟐. 𝟎, h shall not be less than:
𝒇𝒚
𝒍𝒏 (𝟎. 𝟖 + )
𝒉= 𝟏𝟒𝟎𝟎 ≥ 𝟗𝟎 𝒎𝒎
𝟑𝟔 + 𝟗 𝜷