STRUCTURAL
DESIGN
PART I – REINFORCED CONCRETE STRUCTURES
Chapters
1. Basic Properties of Materials
2. Limit State Method
3. Design for Flexure
4. Design for Shear
5. Design for Bond
6. Design of Slabs & Staircases
KIRAN S. R.
Lecturer
It is fed into a rotary kiln and blasted at 1500oC. Clinker (of nodular shape) is obtained, which is
cooled and ground into fine powder. To this 3-5% Gypsum is added to prevent quick setting of
cement.
The cement, thus obtained, contains four major compounds known as Bogue’s Compounds:
Page 1 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Hydration of cement: When Cement mixed with water, the Bogue’s compounds react
with water and heat is liberated (Exothermic Reaction). This heat is called Heat of
Hydration.
Order of hydration is as follows:
Bogue’s Heat of Hydration Remarks
Compounds
C4AF 100 cal/gm Responsible for initial strength development of
C3A 200 cal/gm cement (<3 days)
C3S 120 cal/gm Early strength development of cement (3-7 days)
C2S 60 cal/gm Late strength development of cement (7-28 days)
Coarse Aggregates
particle size > 4.75mm
generally used – Hard blasted granite chips
The nominal maximum size of aggregate should be < (1/4)th the minimum thickness of
the member
In case of heavily reinforced sections, nominal maximum size of aggregate should be
Clear distance between bars minus 5mm whichever is smaller
Minimum cover to reinforcements minus 5mm
Grading of Aggregates
‘Grading’ is the particle size distribution of aggregate; it is measured by sieve analysis,
and is generally described by means of a grading curve, which depicts the ‘cumulative
percentage passing’ against the standard IS sieve sizes.
Page 3 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
In figure, standard grading curves 1, 2, 3 and 4 are shown (plotted per Indian Standards
IS383). The particle size distribution of the given sample of aggregates shall conform to
any of the zones A, B or C. Curve 1 represents the coarsest grading, while curve 4
represents the finest grading.
The grading (as well as the type and size) of aggregate is a major factor which influences
the workability of fresh concrete, and its consequent degree of compaction.
This is of extreme importance with regard to the quality of hardened concrete, because
incomplete compaction results in voids, thereby lowering the density of the concrete and
preventing it from attaining its full compressive strength capability; furthermore, the
impermeability and durability characteristics get adversely affected.
It is seen from the figure given below that with 95% density (i.e., with 5 percent of voids),
there is only 68% strength (i.e., 32% strength lost). This shows that the presence of just
5% voids can lower the strength by 32%.
Presence of more “fines” (i.e., cement & sand) in a concrete mix would improve both
workability and resists segregation (segregation means separation of grout from
aggregates in a concrete mix due to addition of excess water to concrete)
Page 4 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Excess water in concrete tends to rise up to the surface of the mix, as the solid
constituents settle downwards. This is called Bleeding.
Use of seawater for mixing or curing of concrete is not recommended due to the
presence of harmful salts
Generally, water content used in concrete is 180-200 L / m3 of concrete.
Abrams’ Law: Compressive strength of hardened concrete is inversely proportional to
the water-cement ratio (see figure below). A reduction in water-cement ratio generally
results in an increased quality of concrete, in terms of density, strength, impermeability,
reduced shrinkage and creep etc.
Page 5 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Types of Mineral Admixtures (Puzzolonas) [Cl. 5.2 of IS456] – Mineral admixtures are
generally used as partial replacement of cement in concrete. They react with Calcium
hydroxide in the presence of water to form cementitious compounds.
o Fly Ash
o Ground Granulated BlastFurnace Slag (GGBS)
o Silica Fume
o Rice Husk Ash
o Metakaoline
Segregation
Segregation can be defined as the separation of the constituent materials of
concrete.
A good concrete has all its constituents properly distributed to form a
homogenous mixture. To ensure this, optimum grading, size, shape and
surface texture of aggregates with optimum quantity of cement & water
makes a mix cohesive. Such a concrete does not exhibit the tendency for
segregation.
Prime cause of segregation is the difference in specific gravity of
constituents of concrete.
Page 6 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Segregation may be one of the following types:
o Coarse aggregate separating out of the rest
o Cement paste or cement-fine aggregate matrix separating out from
coarse aggregate
o Water separating out of the rest
The conditions that favour segregation are:
o Bad mix proportion
o Inadequate mixing
o Excessive compaction by vibration of wet mix
o Large height of dropping of concrete for placement
o Long distance conveyance of mix
Bleeding
Here, water from the concrete comes out to the top surface of the concrete
after casting.
Page 7 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Exposure Minimum
Condition grade of
concrete for
RCC works
Mild M20
Moderate M25
Severe M30
Very M35
severe
Extreme M40
Classification
o Ordinary concrete – M10 to M20
o Standard concrete – M25 to M55
o High Strength concrete – M60 and above
Page 8 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Poisson Effect: Failure of concrete subject to uniaxial compression is primarily
initiated by longitudinal cracks (cracks developed parallel to direction of loading)
formed due to lateral expansion (because lateral fibres experience tensile stress)
and finally lateral strain exceeds limiting tensile strain of concrete of 0.0001 to
0.0002. These longitudinal cracks generally occur at coarse aggregate-mortar
interface.
The descending part of Stress-Strain curve is attributed to the extensive
microcracking in mortar. This is called Strain-Softening of Concrete.
Page 9 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Secant Modulus at one-third of maximum stress level represents the “Short-term
Static Modulus of Elasticity of Concrete (Ec)”. “Short-term” means the long term
effects of creep & shrinkage are not considered.
According to IS456,
Ec = 5000 f
where fck is the 28-day characteristic compressive strength of 150mm concrete
cubes. Thus, it should be noted that Modulus of Elasticity of concrete is a function
of its strength.
8. PROPERTIES OF STEEL
Page 10 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Characteristic strength of reinforcing steel =
o yield strength of steel– for those with well-defined yield point (Fe250)
o 0.20% Proof Stress – for those without well-defined yield point (Fe415&Fe500)
0.2% Proof Stress is measured as shown below
Page 11 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
NOTE: When effects of temperature, shrinkage and wind (or earthquake) are
considered, in addition to effects of dead, live & impact loads, then the above
values of permissible stresses in concrete & steel may be exceeded upto a limit of
33.33%
Page 12 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
CHAPTER 2
The acceptable limit for safety and serviceability requirements before failure occurs is
known as Limit State.
LSM involves underestimation of the material strength and overestimation of
external loads. For this, the method uses partial safety factor format.
SAFETY SERVICEABILITY
With due consideration to strength, Satisfactory performance of structure
stability & structural integrity. under service loads. Ensures no
If this condition is satisfied, the discomfort to the user
likelihood for “collapse” is acceptably If this condition is satisfied, the
low under service loads (usual or likelihood for “user discomfort” is
expected loads) as well as probable acceptably low under service loads.
overloads (extreme winds, User discomfort may occur due to:
earthquake etc.) o Deflection
Collapse may occur due to: o Cracking
o Exceeding of strength of o Vibrations
material or load bearing o Durability
capacity of material. o Impermeability
o Sliding o Thermal Insulation (or Fire
o Overturning resistance)
o Buckling Limit states involved in user comfort
o Fatigue are called “Limit state of
o Fracture serviceability”, which are defined for,
Limit states involved in collapse are o Deflection
called “Limit State of Collapse” or o Cracking
“Ultimate Limit State”, which are o Durability
defined for the following, o Fire Resistance
o Flexure
o Compression
o Shear
o Torsion
Page 13 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
IMPORTANT TERMINOLOGIES
1. Characteristic Strength
It is the strength of the material below which not more than 5% of the test results
are expected to fall.
Characteristic strength of concrete = 28-day characteristic compressive strength of
150mm concrete cubes (fck). For the design of structures, only 67% of fck is
considered.
Characteristic strength of reinforcing steel = yield strength of steel (fy) or 0.20%
Proof Stress.
2. Characteristic Loads
Loads which have 95% probability of not being exceeded during the life of the
structure.
Magnitudes of these loads are enlisted in:
o IS 875 (Part 1) – Dead Loads
o IS 875 (Part 2) – Live loads
o IS 875 (Part 3) - Windloads
o IS 875 (Part 4) - Snowloads
o IS 875 (Part 5) – Load Combinations
o IS 1893 – Seismic loads
3. Design strength
Design strength =
By this, the strength of material is underestimated
Characteristic strength of material = 0.67 fck (for concrete)
= fy (for reinforcing steel)
Partial safety factor for material = 1.5 (for concrete)
= 1.15 (for reinforcing steel)
.
Therefore, Design strength of concrete = = 0.447 fck ≈ 0.45 fck
.
and, Design strength of steel = = 0.87 fy
.
4. Design Loads
Design Load = Characteristic Load x Partial safety factor for corresponding load
By this, the loads on structure are overestimated
Partial safety factor for different loading conditions is given in Table 18 of IS456
(Page 68)
Eg: For Limit State for Collapse
For structures subjected to Dead loads & Live loads
Design load on the structure = 1.5 DL + 1.5 LL
For structures subjected to Dead loads & Wind loads
Design load on the structure = 1.5 DL + 1.5 WL
Page 14 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
For structures subjected to Dead loads, Live loads & Windloads
Design load on the structure = 1.2 DL + 1.2 LL + 1.2 WL
Page 15 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
o In case of Cold worked bars (Fe415 and Fe500):
Page 16 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
CHAPTER 3
2) Under-reinforced section
o Steel reaches ultimate stress before concrete.
o Here, Yielding of steel occurs first. This is accompanied by wider tensile cracks
and increased curvatures and deflection of the beam. Thus it gives clear warning
to the user about failure. Finally, failure occurs by crushing of concrete.
o In other words, the steel would already have yielded by the time the concrete
crushes.
Page 18 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
o Therefore, strain in
o Concrete (at the extreme compression fibre) = εcu = 0.0035
.
o Steel (on tension side) εst > + 0.002
o Depth of Neutral axis (Xu) for an under-reinforced section is less than Xu,max
o This type of failure is called “Ductile Failure”.
3) Over-reinforced section
o Concrete reaches ultimate stress first.
o Here, crushing of concrete occurs first. It gives no warning to the user about
failure. Hence, it is a catastrophic or disastrous failure.
o In other words, when the concrete at extreme compression fibre crushes, the steel
would not have reached the yield point.
o Therefore, strain in
o Concrete (at the extreme compression fibre) = εcu = 0.0035
.
o Steel (on tension side) εst < + 0.002
o Depth of Neutral axis (Xu) for an over-reinforced section is greater than Xu,max
o This type of failure is called “Brittle Failure”.
Page 19 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
In short, the above three types of sections can be summarized from the strain distribution at
ultimate limit state (i.e. at failure) as shown below.
Page 20 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Page 21 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
2) Dimensions of beam
3) Effective span
[Refer Cl. 22.2] whichever is minimum
= clear span + d (For simply supported
= span of beam measured between centers of supports beam)
= clear span + (d/2) (For Cantilever Beams)
4) Concrete cover
[Refer Cl. 26.4; Table 16]
Clear cover or Nominal cover is the distance measured from the exposed concrete
surface (without plaster and other finishes) to the nearest surface of the reinforcing
bar, including links.
This cover is required
o to protect the reinforcing bars from corrosion and fire
o to give the reinforcing bars sufficient embedment for sufficient bond with concrete
(prevent slippage between concrete & steel).
There is a minimum clear cover value specified for each exposure condition (see
previous table), as this satisfies the durability requirement of RCC structure. The
maximum deviation permitted from these values are “+10 mm and –0mm”.
Minimum clear cover requirements
o for columns = 40 mm
o for footings = 50 mm
5) Spacing of bars
[Refer Cl. 26.3]
Both minimum & maximum limits of spacing between steel bars are specified in code:
o Minimum Limits => ensure that concrete can be placed easily between
bars
o Maximum Limits => ensure that concrete crack-widths get controlled
and bond between concrete & steel is improved.
Codal provisions are summarized in the following figure:
Page 22 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
(a) Singly Reinforced Beams
Page 24 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
LIMIT STATE OF COLLAPSE – FLEXURE
[Refer Cl.38 – Page 69 of IS456]
Assumptions
o Plane sections normal to the beam axis remain plane even after bending, i.e., in an
initially straight beam, normal strain varies linearly over the depth of the section.
o The maximum compressive strain in concrete (at the outermost fibre) εcu = 0.0035.
This is so, because regardless of whether the beam is under−reinforced or over-
reinforced, collapse invariably occurs by the crushing of concrete.
o The tensile strength of the concrete is ignored.
o For the section to be balanced or under-reinforced, the strain εst in the tension
reinforcement shall not be less than εy:
.
=> εst ≥ + 0.002
The distribution of stress and strain across the section is shown above.
Page 25 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
From this, the following may be deduced.
The general expression for Depth of Neutral axis (Xu) is obtained from strain diagram,
considering similar triangles.
The limiting value of depth of Neutral axis (Xu,max), which corresponds to a balanced
.
section, is obtained by substituting εst = + 0.002, in the above equation.
Therefore, we get,
Substituting suitable values of yield strength of steel, the limiting depth of Neutral axis
(Xu,max) may be obtained as follows:
The Concrete Stress block (Compressive stress distribution in concrete at ultimate limit
state) is analysed as follows:
Page 26 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Note: If Xu > Xu,max, then the section is over-reinforced. In such a case, since steel may
not have yielded, the stress in steel shall have not reached 0.87fy.
o Assume a suitable initial (trial) value of Xu
o Determine εst by considering strain compatibility
o Determine the design stress fst corresponding to εst using the design stress-strain
curve
o Derive the value of corresponding to fst by considering T = fst Ast and applying the
force equilibrium condition C = T, whereby
o Compare this value of Xu with the initial value assumed in the first step. If the
difference between the two values is acceptably small, accept this value of Xu.
Otherwise, repeat previous steps with an improved (say, average) value of Xu,
until convergence.
Limiting moment of resistance of the beam section (Mu,lim) corresponds to the condition
Xu = Xu,max is given by:
Mu,lim = 0.36 fck b xu,max (d – 0.42 xu,max)
OR
Mu,lim = 0.87fy Ast (d – 0.42 xu,max)
Page 27 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Analysis of Doubly reinforced Beams
Doubly reinforced beams are resorted to under following circumstances:
Where cross sectional dimensions of the beam are restricted, due to architectural or
other considerations
Where singly reinforced beam is inadequate to resist moment
Where reversal of moments is likely to occur
Presence of compression reinforcement helps reduce long-term deflection & cracking due to
shrinkage & creep.
The distribution of stress and strain across the section is shown above. From this, the following
may be deduced.
. .
Xu =
.
In the above equation, fsc is taken from Stress-Strain curve of steel for the corresponding
value of strain εsc computed from:
In general practice, the value of ratio (d’/d) ranges between 0.05 to 0.20.
Page 28 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Value of fsc is given by:
o = 0.87 fy = 217.5 N/mm2, for Fe250 grade steel
o If Fe415 or Fe500 is used, the compression steel would not have yielded as
Fe250. Hence, fsc is obtained from εsc.
Value of fsc for a balanced section is given below (in N/mm2)
Page 29 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Page 30 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Page 31 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Page 32 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Page 33 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Page 34 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Page 35 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Page 36 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Page 37 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Page 38 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Page 39 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Page 40 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Page 41 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
DESIGN EXAMPLES
Page 42 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Page 43 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Page 44 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Page 45 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Page 46 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Page 47 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Page 48 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Page 49 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Analysis of Singly reinforced Flanged Beams
Involves T-sections & L-sections in Beam-supported slab floor system
Flanged beams have 2 parts
o Web: The fully rectangular portion of the beam other than the over hanging parts
of slab
o Flange: The overhanging parts of slab
Flexural compressive stress distribution developed in flange is not uniform along its width
(see the figure below). To ease the analysis, this non-uniform stress distribution is
replaced by an equivalent uniform distribution (of magnitude = the peak stress in actual
distribution) over a reduced width known as “equivalent flange width” or “effective
flange width”, represented as bf.
bw = breadth of web
Page 50 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
The value of bf should be restricted as shown:
Analysis:
Case 1: Neutral axis lies within flange, i.e., Xu ≤ Df
Since all concrete on the tension side is considered ineffective, the T-beam
may be analysed as a rectangular beam of width bf and effective depth d.
Compressive force in Concrete C = 0.36 fck bf xu
Tensile force in steel T = 0.87 fy Ast
Depth of neutral axis Xu is obtained from C = T, as:
.
Xu =
.
Ultimate moment of resistance of the beam section (Mu) is given by:
Mu =C.z = 0.36 fck bf xu (d – 0.42 xu)
OR
Mu =T.z = fst Ast (d – 0.42 xu)
where fst = 0.87fy if Xu ≤ Xu,max
Page 51 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Case 2: Neutral axis lies within web, i.e., Xu > Df
𝟑
Subcase 2(a): If Xu ≥ Df
𝟕
𝟑
Subcase 2(b): If Xu < Df
𝟕
Page 53 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
CHAPTER 4
where I is the second moment of area of the section about the neutral axis, Q the first moment
of area about the Neutral Axis of the portion of the section above the layer at distance y from the
NA, and b is the width of the beam at the layer at which Ƭ is calculated.
Consider an element at a distance y from the Neutral Axis (NA).
The combined flexural and shear stresses on that element can be resolved into equivalent
principal stresses f1 and f2 acting on orthogonal planes.
As a result, the stress on the beam is depicted in terms of the principal stress trajectories as
shown.
Page 54 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
In a material like concrete which is weak in tension, tensile cracks would develop in a direction
that is perpendicular to that of the principal tensile stress. Thus the compressive stress
trajectories in the above figure indicate potential crack patterns, as shown below.
MODES OF CRACKING
1) Flexural cracks
Occurs in reinforced concrete beams of usual proportions, subjected to relatively high
flexural stresses fx and low shear stresses Ƭ.
Maximum principal tensile stress occurs in the outer fibre at the bottom face of the
concrete beam at the peak moment locations. As a result, cracks are formed, which are
termed as flexural cracks.
o
These are formed at 90 from the extreme tension fibre towards neutral axis.
These are controlled by the tension bars.
3) Flexure-Shear cracks
When a ‘flexural crack’ occurs in combination with a ‘diagonal tension crack’, the crack is
termed as a flexure-shear crack.
Occurs in beam subjected to both flexure and shear.
Note: The presence of shear stress reduces the strength of concrete in compression as
well as tension. Accordingly, the tensile strength of the concrete in a reinforced concrete
beam subjected to both flexure & shear will be less than that subjected to flexure only.
Here, flexural crack usually forms first, and extends into a diagonal tension crack.
Page 56 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
SHEAR PARAMETERS FOR DESIGN
1) Nominal Shear Stress
For prismatic members of rectangular (or flanged) sections, the Code (Cl. 40.1) uses
the term nominal shear stress Ƭv, defined at the ultimate limit state, as
where Vu is the factored shear force at the section under consideration, b is the width of
the beam (taken as the web width bw in flanged beams), and d the effective depth of the
section.
In the case of members with varying depth, the nominal shear stress, defined above,
needs to be modified, to account for the contribution of the vertical component of the
flexural tensile force Tu which is inclined at an angle β to the longitudinal direction.
Accordingly, the nominal shear stress (Cl. 40.1.1 of the Code), is obtained as
where Vu and Mu are the applied factored shear force and bending moment at the section
under consideration. The negative sign applies where Mu increases in the same direction
as the depth increases and the positive sign applies where Mu decreases in this direction,
as shown below.
Page 57 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
2) Critical Sections for shear
Critical sections are those sections at which shear force is maximum.
Location of critical sections for different cases are shown below. [Refer Cl. 22.6.2]
Page 58 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Shear strength of slabs is higher than that of beams, owing to small thickness. The
thinner the slab, the greater is the increase in shear strength. The Code (Cl. 40.2.1.1)
suggests an increased shear strength for slabs, equal to k Ƭc, where the multiplication
factor k ranges between 1 and 1.3. In general, slabs subjected to normal distributed
loads satisfy the requirement Ƭv < Ƭc, and hence do not need shear reinforcement.
Shear reinforcement, also known as web reinforcement may consist of any one of the
following systems (Cl. 40.4 of the Code)
a) stirrups perpendicular to the beam axis;
b) stirrups inclined (at 45° or more) to the beam axis; and
c) longitudinal bars bent-up (usually, not more than two at a time) at 45° to 60° to the
beam axis, combined with stirrups.
By far, the most common type of shear reinforcement is the two-legged stirrup, comprising
a closed or open loop, with its ends anchored properly around longitudinal bars/stirrup
holders (to develop the yield strength in tension). It is placed perpendicular to the member
axis (‘vertical stirrup’), and may or may not be combined with bent-up bars.
Where bent-up bars are provided, their contribution towards shear resistance shall not be
more than half that of the total shear reinforcement.
Page 59 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
5) Limiting Ultimate Shear Strength of beam (Ƭc,max)
The nominal shear stress (Ƭv) on the beam should not exceed the limiting total shear
strength of beam including shear reinforcement (Ƭc,max).
Such a limit is set to the shear stress in beam Ƭv because : if the shear reinforcement
provided in the section is excessive, failure may occur by crushing of concrete (known
as shear-compression failure which occurs due to crushing of the reduced concrete section
after formation of flexure-shear crack), even before yielding of shear reinforcements. Since
this is a brittle fracture, such a failure is undesirable.
Thus by limiting the shear stress in beam Ƭv to less than Ƭc,max, shear-compression
failures can be prevented.
Values of Ƭc,max is given in Table 20 of IS456. It may also be obtained from the
following approximate relation.
Ƭc,max ≈ 0.62 𝑓
In the case of solid slabs, the Code (Cl. 40.2.3.1) specifies that Ƭv should not exceed
0.5 Ƭc,max .
Asv =n ( φ2)
From above equation, the required spacing sv of ‘vertical stirrups’ for a
selected diameter φ is given by:
Page 60 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
If Ƭv < Ƭc
If Ƭv < 0.5 Ƭc
No shear reinforcement is required.
If Ƭv > 0.5 Ƭc
The Code (Cl. 26.5.1.6) specifies a minimum shear reinforcement to be
provided in the form of stirrups.
Page 61 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Page 62 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Page 63 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Page 64 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Page 65 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
CHAPTER 5
Page 66 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Thus, tension steel required at any section must be extended beyond
the theoretical cutoff point by a distance = effective depth (d).
Codal provisions:
Tension steel required at any section must be extended beyond the
theoretical cutoff point by a distance = 12 x Bar Diameter.
In general, bond strength is enhanced when the following measures are adopted:
o deformed (ribbed) bars are used instead of plain bars;
o smaller bar diameters are used;
o higher grade of concrete (improved tensile strength) is used;
o increased cover is provided around each bar;
o increased length of embedment, bends and /or hooks are provided;
o mechanical anchorages are employed;
o stirrups with increased area, reduced spacing and/or higher grade of steel are
used;
Page 67 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
o termination of longitudinal reinforcement in tension zones is avoided;
o any measure that will increase the confinement of the concrete around the bar is
employed.
There are two types of loading situations which induce bond stresses, and accordingly
‘bond’ is characterised as:
Flexural bond stress / Local Bond stress is that which arises in flexural
members on account of shear or a variation in bending moment. Evidently,
flexural bond is critical at points where the shear (V= dM/dx) is significant.
where Σo is the total perimeter of the bars at the beam section under
consideration, and z is lever arm.
o Actual flexural bond stress is affected by Flexural cracking, local slipping and
splitting, which are not taken care of by the above equation.
Page 68 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Anchorage bond stress / Development bond stress is stress developed in
steel reinforcement bars at the extreme ends or at cutoff points. See the following
example, where steel bar is provided on the tension side of a cantilever beam.
o The steel bar in the beam is designed based on the maximum bending moment in
the beam that occurs at section D. Since the bar is under tensile stress fs, it should
not be terminated at D, but extended further to section C, such that the bond
stress between concrete and the additional length of bar L resists the tensile
stress fs in the bar. Therefore, average anchorage bond stress ua
where τbd is the ‘design bond stress’, which is the permissible value of the average
anchorage bond stress ua, and fs = 0.87fy
τbd values for plain bars in tension are given in Cl. 26.2.1.1.
τbd values are increased by 60%, for deformed bars.
τbd values are increased by 25%, for bars in compression.
Page 69 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
o However, when the required bar embedment cannot be conveniently provided due
to practical difficulties, bends, hooks and mechanical anchorages can be used.
[Refer Cl. 26.2.2]
Bends:
The anchorage value (or the equivalent anchorage length) of a
bend shall be taken as 4 times the diameter of the bar for each
45o bend.
Maximum anchorage value of a bend = 16φ
A ‘standard 90o bend’ has anchorage value = 8φ (including a
minimum extension of 4φ.)
Hooks:
When the bend is turned around 180o, it has anchorage value =
16φ (including a minimum extension of 4φ), it is called a standard
U-type hook.
The minimum internal turning radius (r) specified for a hook =
o 2φ for plain mild steel bars
o 4φ for cold-worked deformed bars
Hooks are generally considered mandatory for plain bars in
tension
Page 70 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Note: Bends and hooks introduce bearing stress in the concrete that they bear against. To
ensure that these bearing stresses are not excessive, the turning radius r should be sufficiently
large. The Code (Cl. 26.2.2.5) recommends a check on the bearing stress fb inside any bend or
hook, calculated as follows:
where Fbt is the design tensile force in the bar, r is the internal radius of the bend, and φ is the
bar diameter. Bearing stress fb should be less than the limiting value stipulated in the code.
Mechanical anchorages:
o Mechanical anchorages in the form of welded plates, nuts and
bolts, etc. can be used, provided they are capable of developing
the strength of the bar without damage to concrete (to be
ascertained through tests).
Page 71 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
SPLICING OF REINFORCEMENTS
Splices are required when
o bars required are longer than available lengths, and hence needs to be extended.
o the bar diameter has to be changed along the length.
The purpose of ‘splicing’ is to transfer effectively the axial force from the terminating bar
to the connecting (continuing) bar. This invariably introduces stress concentrations in the
surrounding concrete.
As per IS456,
o splices in flexural members should not be at sections where the bending moment
is more than 50 percent of the moment of resistance
o not more than half the bars shall be spliced at a section”
There are 3 ways of splicing of bars:
o Lap Splices [Refer Cl. 26.2.5.1]
Only for bars of dia φ ≤ 36 mm
Lap length L =
≥ Ld or 24 φ, for bars in compression
≥ 2Ld or 30 φ, for bars in tension
Page 72 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
CHAPTER 6
1) One-way slabs
These have either one of the following definitions:
Slabs which are supported only on two opposite sides
Slabs which are supported on all four sides and its length is atleast greater than
twice the width, i.e., >2
2) Two-way slabs
Slabs which are supported on all four sides and its length is comparable to the
width, i.e., <2
Page 73 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
DESIGN OF ONE-WAY SLABS
Slabs under flexure behave in the same way as beams.
A slab of uniform thickness subject to a bending moment uniformly distributed over its
width may be treated as a wide shallow beam for the purpose of analysis and design.
Main reinforcing bars are uniformly spaced over the width of the slab. For convenience,
computations are generally based on a typical one-metre wide strip of the slab
considered as a beam, i.e., Take b = 1000 mm.
If s is the centre-to-centre spacing of bars in mm, then the number of bars in the 1m wide
strip is given by 1000/s. Accordingly, denoting Ab as the cross-sectional area of one bar
(equal to πφ2/4) and the required area of tensile steel in 1m wide strip (Ast), expressed in
units of mm2/m, it may concluded that
=
This effect is resisted by the remainder of the slab. These give rise to secondary
moments in the transverse direction
o Also, secondary moments are also generated locally in slabs due to concentrated
loads.
o Further, shrinkage and temperature stresses developed in slabs shall also be
resisted by secondary reinforcements.
Q1. Design a simply supported RCC slab for an office floor having clear dimensions 4m x 10m
with 230mm thick masonry walls all around. The slab carries 4kN/m2 liveload & 1kN/m2 floor
finish. Use M25 concrete & Fe415 steel.
Ans:
Given, L = 10m; B = 4m
Determining type of slab:
Effective span l = c/c distance b/w supports of shorter span = 4 + 0.23 = 4.23m
Take Modification factor = 1.25 for one-way slabs (generally for tension steel 0.4-0.5%)
Page 75 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Hence, ≤ 20 x 1.25 = 25
=> ≤ 25
=> d ≥ 169.2 mm
Therefore, Take d = 175mm
and D = 175+25 = 200mm
Finding Effective Span:
Effective span = smaller of (1) Clear span + d = 4.00 + 0.175 = 4.175m
(2) c/c distance between supports = 4 + 0.230 = 4.230m
= 4.175m
Because slab is considered as
Determination of Moments: a one-metre wide strip beam
3
Loads: Dead load = 25kN/m x 1m x D = 25 x 1 x 0.2 = 5 kN/m
2
Live load = 4kN/m x 1m = 4 kN/m
2
Finish load = 1kN/m x 1m = 1 kN/m
. .
Factored Moment Mu = = = 32.68 kNm
.
Since xu =
.
. .
Ast = = 546mm2
.
Assuming 12mm dia bars,
. /
spacing s = 1000 = 1000 x = 207mm
Cl. 26.5.2.1 .
= x 1000 x 200 = 240mm2
Page 77 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Check for spacing of distribution steel:
Max spacing in distributors = minimum of (1) 5d = 3 x 175 = 875mm
Cl. 26.3.3 (b) (2) (2) 450mm
= 450mm
Since s < 450mm, therefore Safe
____________________________________________________________________________
Mu =
Provide reinforcement on the top
____________________________________________________________________________
Mu =
Provide reinforcement on the top
Page 78 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
DESIGN OF STAIRCASE
Staircase is the means of access between the various floors in the building.
It consists of a flight of steps, usually with one or more intermediate landings (horizontal
slab platforms) provided between the floor levels.
The horizontal top portion of a step (where the foot rests) is termed tread and the vertical
projection of the step (i.e., the vertical distance between two neighbouring steps) is called
riser.
Generally, values of tread & rise are adopted in the range of 300 mm and 150 mm
respectively — particularly in public buildings.
Also, Generally, number of risers in a flight should not exceed about 12 in number.
Number of Treads = Number of Risers - 1
Width of the stair is generally around 1.1 – 1.6m, and in any case, should normally not be
less than 0.85.
The horizontal projection (plan) of an inclined flight of steps, between the first and last
risers, is termed going.
The steps in the flight can be designed in a number of ways (see figure on next page):
o with waist slab
o with tread-riser arrangement (without waist slab)
o with isolated tread slabs
Types of Stair case based on Geometric Configuration (see figure on next page):
o Straight flight stairs
o Quarter-turn stairs
o Dog-legged stairs
o Open-well stairs
o Spiral stairs
o Helicoidal stairs
See Cl.33 of IS456 for design of stairs
Page 79 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Page 80 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Page 81 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Relevant provisions for staircase design:
Maximum Bending moment occurs at midspan of this simply supported beam. This is
computed.
Remaining steps of design is similar to that of one-way slab
Q4. Design a simply supported dog-legged staircase for an office building, given the following
data. Use M20 concrete & Fe415 steel.
Page 83 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Determining depth of waist slab:
Effective span l = c/c distance b/w supports = 2.43 + 1.25 + 1.25 + 0.23 = 5.16m
Take Modification factor = 1.25 for one-way slabs
Hence, ≤ 20 x 1.25 = 25
=> ≤ 25
=> d ≥ 206 mm
Therefore, Take d = 235mm
and D = 235+25 = 260mm
Effective span = smaller of (1) Clear span + d = (2.43 + 1.25 + 1.25) + 0.235= 5.165m
(2) c/c distance between supports = 5.160m
= 5.160m
Because slab is
Determination of Moments: considered as a one-
metre wide strip
Loads on going:
3
Self weight of waist slab = 25kN/m x 1m x 0.26 x =7.56 kN/m
3 .
Self weight of steps = 25kN/m x 1m x Avg thickness = 25 x 1 x = 2 kN/m
2
Live load = 5kN/m x 1m = 5 kN/m
2
Finish load = 0.6kN/m x 1m = 0.6 kN/m
Page 84 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Loads on landing:
3
Self weight of waist slab = 25kN/m x 1m x 0.26 = 6.5 kN/m
2
Live load = 5kN/m x 1m = 5 kN/m
2
Finish load = 0.6kN/m x 1m = 0.6 kN/m
= 71.40 kNm
Check with Mulim:
Solving this quadratic equation, taking smaller of the roots, we get xu = 46.00 mm
.
Since xu =
.
.
Ast = = 917mm2
.
Assuming 12mm dia bars,
. /
spacing s = 1000 = 1000 x = 123mm
Slabs that deform with significant curvatures in two perpendicular directions must be
designed as two-way slabs
Effective span = minimum of (1) clear span + d
(2) centre-to-centre distance between supports
Effective span is represented as:
o lx : shorter effective span
o ly : longer effective span
The corners of these slabs have a tendency to lift up, unless otherwise it is restrained
(held down by force). Such slabs, the corners of which are free to lift up, are called
Torsionally unrestrained two-way slabs [Refer Annex D-2 – Page 90]
If corners are prevented from lifting up, then such slabs are called Torsionally restrained
two-way slabs. This is because they develop Twisting Moments, which are significant
along diagonals. Hence the corners have to be suitably reinforced at the top & bottom, in
order to resist the potential cracks that may develop at corners of the slabs due to
twisting moments. Such reinforcements are called Torsion Reinforcements. [Refer Annex
D-1], shown below.
Page 87 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Q5. Design a simply supported slab for a room of internal dimensions 4m x 5m. The slab is
subjected to 3kN/m2 liveload & 1kN/m2 Finishload. Use M20 concrete & Fe415 steel. Assume
the slab corners are free to lift up.
Ans:
Determining type of slab:
Shorter Effective span lx = c/c distance b/w supports of shorter span = 4 + 0.23 = 4.23m
Hence, ≤ 20 x 1.5 = 30
=> ≤ 30
=> d ≥ 141 mm
Therefore, Take d = 145mm
and D = 145+25 = 170mm
Page 88 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Finding Effective Span:
Shorter Effective span lx = smaller of (1) Clear span + d = 4.00 + 0.145 = 4.145m
Longer Effective span ly = smaller of (1) Clear span + d = 5.00 + 0.145 = 5.145m
Determination of Moments: Since slab corners free to lift up, see Cl.D-2 of IS456 – Page 90
Design moments per unit width:
Page 89 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Check for depth of Neutral axis:
Shorter span:
Solving this quadratic equation, taking smaller of the roots, we get xu = 18.73 mm
Longer span:
Solving this quadratic equation, taking smaller of the roots, we get xu = 12.03 mm
.
Since xu =
.
. .
Ast = = 374mm2
.
Assuming 12mm dia bars,
. /
spacing s = 1000 = 1000 x = 302mm
Page 90 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Check for spacing of main steel:
Max spacing in main bars = minimum of (1) 3d = 3 x 145 = 435mm
Cl. 26.3.3 (b) (1) (2) 300mm
= 300mm
Since s ≤ 300mm, therefore Safe
Determining area of main steel along longer span:
.
Since xu =
.
. .
Ast = = 240mm2
.
Assuming 12mm dia bars,
. /
spacing s = 1000 = 1000 x = 470mm
Q6. Design a simply supported slab for a room of internal dimensions 4m x 5m. The slab is
subjected to 3kN/m2 liveload & 1kN/m2 Finishload. Use M20 concrete & Fe415 steel. Assume
the slab corners are held down (or prevented from lifting up).
Ans:
Determining type of slab:
Shorter Effective span lx = c/c distance b/w supports of shorter span = 4 + 0.23 = 4.23m
Hence, ≤ 20 x 1.5 = 30
Page 91 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Therefore, Take d = 145mm
and D = 145+25 = 170mm
Finding Effective Span:
Shorter Effective span lx = smaller of (1) Clear span + d = 4.00 + 0.145 = 4.145m
Longer Effective span ly = smaller of (1) Clear span + d = 5.00 + 0.145 = 5.145m
Determination of Moments: Since slab corners held down, see Cl.D-1 of IS456 – Page 90
Therefore,
2
Mux = 0.075 x 12.375 x 4.145 = 15.95 kNm
2
Muy = 0.056 x 12.375 x 4.145 = 11.91 kNm
Page 92 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
Check for depth of Neutral axis:
Shorter span:
Longer span:
Solving this quadratic equation, taking smaller of the roots, we get xu = 11.80 mm
.
Since xu =
.
.
Ast = = 319mm2
.
Assuming 12mm dia bars,
. /
spacing s = 1000 = 1000 x = 355mm
Page 93 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum
But, since s ≤ 300mm condition should be satisfied
.
Since xu =
.
. .
Ast = = 235mm2
.
Assuming 12mm dia bars,
. /
spacing s = 1000 = 1000 x = 481mm
Area of Torsion reinforcement in each of the layers = x Ast for shorter span
= x 319 = 240mm2
Page 94 of 95
Prepared by Kiran S. R., Lecturer, Department of Civil Engineering, Central Polytechnic College Trivandrum