Freeze-drier (T-3)
1. Specification sheet
SPECIFICATION SHEET
IDENTIFICATION
Name of Equipment Freeze-drier
Equipment Code T-3
Number of Units 1
Function To turn Purified Collagen Hydrolysate
Crystals into Collagen Hydrolysate
Powder
Operation Batch
Method Bulk Method (feed is placed on shelf
trays)
Material Handled Water-Dialysed Collagen, Water
SHELF DESIGN
Shelf Temperature -20ºC to 70ºC
Total Shelf Area 144 m2
Number of Shelves 16
Shelf Size 1219mm x 1524mm
Shelf Depth 230 mm
Shelves Spacing 120 mm
Shelves Thickness 4.00 mm
Shelf Cooling Rate (-20ºC to +40ºC) <60 minutes
Material of Construction AISI Stainless Steel 316 L
COMPRESSOR: REFRIGERATION SYSTEM
Refrigerant R-507
Compressor Type Rotary
Compressor Power Requirement for 125 HP
Condenser Refrigeration
Compression Ratio 15:1
UNIT DIMENSIONS
Length 7150 mm
Width 2790 mm
Height 2470 mm
197
2. Diagram for freeze-drier
198
199
3. Summary of assumptions
2. The tube of the heat exchanger used is ¾ inch schedule 40 carbon steel
pipe, square pitch for the condenser and ¾ inch schedule 40 stainless
used for the (condenser) heat exchangers and AIS Stainless Steel 316L
and Manufacturing
minutes because the process heats the frozen feed from -10⁰C to -
minutes.
200
- Shelves thickness: 4 mm
column.
13. The evaporator temperature is set 5ºC lower than the process
condenser temperature.
27ºC.
201
4. Based from the “Development of the freeze drying process—
given by:
dW −1 −0.85
= W dt
dt 77.5
Where,
dW kg H 2 O
=
dt kg collagen hydrolysate ∙ hr
W=
mass water kg
mass collagen h ydrolysate kg( )
t=time(hrs )
t 0.087
dW
∫ dt =− ∫ 77.5
W
−0.85
0 0.25
Using Q=UA ∆T
202
Where Q= -79,258.40 kJ
J
U =3.7 2
m ∙ s∙K
∆ T =T ¿ −T out
∆ T =10−25
∆ T =−15 K
Q
AT =
U ∆T
−79,258.40 kJ 1000 J
x
60 s 1 kJ
166 mins x
1 min
AT =
J
3.7 2 x−15 K
m ∙s ∙K
AT =143.38 m2
AT
A per shelf =
16
143.38
A per shelf =
16
2
A per shelf =8.96 m
203
E. Design computation
Study, a freeze dryer equipment consists of: a chamber containing shelves through
which a heat transfer fluid can be circulated, a condenser for trapping water
204
F. Refrigeration system
A B
temperature must be 5ºC lower than the process condenser temperature. Thus, the
where:
T A=−30ᵒC
P A =0.21234 MPa
kJ
H A =34.1772
mol
kJ
S A =0.1692
mol−K
kJ
S A =SB =0.1692
mol K
PB =1.56 MPa
By extrapolation:
206
H = 35.86 kJ/mol
T C =37 ᵒC
kJ
H C =25.25
mol
kJ
H C =H D =25.25
mol
25.185−15.8185
x=
34.1772−15.8185
x=0.51
201,280.42 KJ
mR −507 =
kJ 1 kmol 1000 mol 60 sec
( 34.1772−25.185 ) x x x 180 mins x
mol 98.9 kg 1 kmol 1 min
kg
mR −507 =0.205
sec
207
G. For heating system, based on Carlo Vecchio’s Freeze-drying
( )( )
k−1
k P2 k
W Theo =P1 Q 1 [ −1]
k −1 P1
where:
kg 1lb
0.205
x 3
m sec 0.45359 kg ft
Q= = =8.87
ρ kg 1 lb 0.02831685m 3 sec
19.70 3 x x
m 0.45359 kg 1f t 3
( )( )
lb f144 i n
2
ft 1.114
3
226.3 psia
1.114−1
1 HP ∙ sec
W Theo =(2.2 2 x )(8.87 ) [ 1.114
−1]( )
in ft
2
sec 1.114−1 2.2 psia 550 ft ∙ lb f
W Theo =80.21 HP
208
Actual compressor power requirement:
W Theo 80.21 HP
W Actual = =
n eff .70
Horsepowera
1/20, 1/12, 1/8, 1/6, 1/4, 1/3, 1/2, 3/4, 1/2, 11-1/2, 2, 3, 5, 7-1/2, 10, 15, 20, 25,
30, 40, 50,60, 75, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600,
700, 800, 900, 1000, 1250, 1500, 1750, 2000, 2250, 2500, 3000, 3500,
4000, 4500, 5000and up to 30,000
shown above.
pressure.
T Final =55.15ᵒC
P Final=1.56 MPa
209
R=P Final : PInitial =1560 KPa :101.325 KPa
R=15:1
Compressor type:
The different compressor types have attributes that make them more
suitable for different applications. The attributes like cooling capacity, efficiency,
reliability, etc. are key selection factors to consider. The Figure below shows the
Source: Paul Lin & Victor Avelar’s The Different Types of Cooling
Compressors Study
210
Since the computed actual power requirement is 85.45 kW, the recommended
above.
Length = 7150 mm
Width = 2790 mm
Height = 2470 mm
211