Professional Documents
Culture Documents
sv = -1 mm c/c
PROJECT : BMRC PAGE : 1
PART OF STRUCTURE : KUVEMPU DESIGN BY : Ajeet
REF. DRAWING. : CHEACKED BY: PC
DATE :
DESIGN OF RAFT FOUNDATION FOR WATER TANK THICK-600MM
Grade of concrete, fck = 30
Permissible stress in steel = 150 N/mm2
Modular Ratio (m) = 9.3
Permissible stress in comp. bending, σcbc = 10
Permissible tensile stress of concrete in due to bending, σct' = 2.0 N/mm2
Angle of repose = 30
Cover = 50 mm
Density of soil = 18 kN/m3
Coefficient of active E.P., ka = 0.33
Coefficient of passive E.P., kp = 3
Gross SBC of soil = 200 kN/m2
Thickness of raft = 0.6 m
Design of bottom slab (top reinforcement)
Required Provided
Moment Ast, Ast,
kN-m deff, mm Φ mm2 Spacing Spacing mm2 pt
140.00 542 16 1946 103 100 2011 0.371 Ok
Design of bottom slab (bottom reinforcement)
Required Provided
Moment Ast, Ast,
kN-m deff, mm Φ mm2 Spacing Spacing mm2 pt
185.00 540 20 2571 122 100 3142 0.582 Ok
Important Check
Check for stress in steel
p = 0.52 %
x/d = 0.27
fs(Bending) = 67.15 N/mm^2
Total = 67.15 N/mm^2 ok
Check for Cracking(Assuming uncrack Section)
I = 2E+10 mm^4
Bending Tension = 2.83 N/mm^2 Unsafe
Important Check
Check for stress in steel
p = 0.27 %
x/d = 0.20
fs(Bending) = 38.96 N/mm^2
Total = 38.96 N/mm^2 ok
Check for shear
short span = 6.75 m
Span for shear =span-2d 5.666 m
Net pressure = 3.5 T/m2
Shear stress = 18.2943 T/m2
Allowable shear stress
PROJECT : BMRC PAGE : 1
PART OF STRUCTURE : KUVEMPU DESIGN BY : Ajeet
REF. DRAWING. : CHEACKED BY: PC
DATE :
Design of Under Ground Water tank wall-RW-1 as per IS-3370(Part-IV) DesignTable
Water tank dimensions
Steel
Dia of bar Required Reinforcement Provided Reinforcement
Typ
e f Ast, mm 2
Spacing Spacing Ast, mm2
A 16 661 304 150 1341
B 12 453 250 125 905
C 12 469 241 125 905
D 16 661 304 125 1609
E 12 705 161 125 905
F 16 661 304 150 1341
G 12 466 243 125 905
H 16 661 304 125 1609
General Data
Freely supported
2.9
28.42 kN/m2
12.850
Value of Moment Coeffiecent
Tension in wall Note :-when sign +ve that means Tension in remote face.
when sign -ve that means Tension in water face..
Maximum Horizontal Tension = KwH^2 49.9554 KN
Moment :- Horizontal Moment my.wH^3
Vertical Moment= mx.wH^3
Mid Span moment Edge moment
S NO X/H Coefficent Coefficent
Vertical Moment Horizontal Moment Vertical Moment Horizontal Moment
1 0 0.000 0.000 0.000 0.000
2 0.25 -1.912 -9.321 8.365 2.390
3 0.5 -31.072 -15.058 13.624 3.824
4 0.75 -2.629 -13.146 12.190 3.107
5 1 0.000 0.000 0.000 0.000
Steel Required.
Mid Span Steel Required. Edge Steel Required
S NO X/H
Vertical steel Horizontal Steel Vertical SteelCoefficent
Horizontal Steel
1 0 0.00 384.27 0.00 384.27
2 0.25 40.69 582.63 178.01 435.13
3 0.5 661.18 704.69 289.90 465.65
4 0.75 55.95 664.00 259.39 450.39
5 1 0.00 384.27 0.00 384.27
Design of Water tank wall RW-1 for Soil Pressure
Freely supported
2.9
17.43 kN/m2
12.85
Value of Moment Coeffiecent
Tension in wall Note :-when sign +ve that means Moment in remote face.
when sign -ve that means Moment in water face..
Maximum Horizontal Tension = KwH^2 0 KN
Moment :- Horizontal Moment my.wH^3
Vertical Moment= mx.wH^3
Mid Span moment Edge moment
S NO X/H Coefficent Coefficent
Vertical Moment Horizontal Moment Vertical Moment Horizontal Moment
1 0 0.00 0.000 0.000 0.000
2 0.25 -1.760 -3.226 1.906 -1.466
3 0.5 -1.613 -2.053 1.613 -2.346
4 0.75 3.079 -0.147 0.733 3.959
5 1 15.836 3.226 0.000 0.000
Steel Required
Important Cheack
Cheack for stress in steel
For Vertical Steel:-
p= 0.30 %
x/d= 0.21
fs(Bending)= 18.94 N/mm^2
Fs(Tension)= 0 N/mm^2
Total= 18.94 N/mm^2 Safe
For Horizontal Steel:-
p= 0.20 %
x/d= 0.82
fs(Bending)= 11.75 N/mm^2
Fs(Tension)= 55.20 N/mm^2
Total= 66.95 N/mm^2 Safe
Steel
Dia of bar Required Reinforcement Provided Reinforcement
Typ
e f Ast, mm 2
Spacing Spacing Ast, mm2
A 16 325 619 200 1006
B 12 639 177 150 755
C 12 371 305 150 755
D 16 325 619 200 1006
E 12 639 177 150 755
F 16 325 619 200 1006
G 12 371 305 150 755
H 16 325 619 200 1006
General Data
Freely supported
2.9
28.42 kN/m2
6.8
Value of Moment Coeffiecent
Tension in wall Note :-when sign +ve that means Tension in remote face.
when sign -ve that means Tension in water face..
Maximum Horizontal Tension = KwH^2 36.36 KN
Moment :- Horizontal Moment my.wH^3
Vertical Moment= mx.wH^3
Mid Span moment Edge moment
S NO X/H Coefficent Coefficent
Vertical Moment Horizontal Moment Vertical Moment Horizontal Moment
1 0 0.000 0.000 0.000 0.000
2 0.25 -1.912 -9.321 8.365 2.390
3 0.5 -3.107 -15.058 13.624 3.824
4 0.75 -2.629 -13.146 12.190 3.107
5 1 0.000 0.000 0.000 0.000
Steel Required.
Mid Span Steel Required. Edge Steel Required
S NO X/H
Vertical steel Horizontal Steel Vertical SteelCoefficent
Horizontal Steel
1 0 0.00 279.69 0.00 279.69
2 0.25 45.57 501.85 199.37 336.66
3 0.5 74.05 638.56 324.69 370.83
4 0.75 62.66 592.99 290.51 353.74
5 1 0.00 279.69 0.00 279.69
Design of Water tank wall RW-2 for Both side water.
Freely supported
Note:- when
Water is in Both
face. The moment
coefficent will be
2.9 zero anly tesion
will govern in this
case.
28.42 kN/m2
6.8
Value of Moment Coeffiecent
Tension in wall Note :-when sign +ve that means Moment in remote face.
when sign -ve that means Moment in water face..
Maximum Horizontal Tension = KwH^2 83.61 KN
Moment :- Horizontal Moment my.wH^3
Vertical Moment= mx.wH^3
Mid Span moment Edge moment
S NO X/H Coefficent Coefficent
Vertical Moment Horizontal Moment Vertical Moment Horizontal Moment
1 0 0.00 0.000 0.000 0.000
2 0.25 1.912 9.321 -8.365 -2.390
3 0.5 3.107 15.058 -13.624 -3.824
4 0.75 2.629 13.146 -12.190 -3.107
5 1 0.000 0.000 0.000 0.000
Steel Required
Important Check
Cheack for stress in steel
For Vertical Steel:-
p= 0.25 %
x/d= 0.19
fs(Bending)= 10.36 N/mm^2
Fs(Tension)= 0 N/mm^2
Total= 10.36 N/mm^2 Safe
For Horizontal Steel:-
p= 0.19 %
x/d= 0.81
fs(Bending)= 14.69 N/mm^2
Fs(Tension)= 48.16 N/mm^2
Total= 62.84 N/mm^2 Safe
Steel
Dia of bar Required Reinforcement Provided Reinforcement
Typ
e f Ast, mm 2
Spacing Spacing Ast, mm2
A 16 378 532 200 1006
B 12 400 283 150 755
C 12 400 283 150 755
D 16 378 532 200 1006
E 12 532 212 150 755
F 16 378 532 200 1006
G 12 677 167 150 755
H 16 378 532 200 1006
General Data
Freely supported
29.4 kN/m2
4.3
Value of Moment Coeffiecent
Tension in wall Note :-when sign +ve that means Tension in remote face.
when sign -ve that means Tension in water face..
Maximum Horizontal Tension = KwH^2 52.02 KN
Moment :- Horizontal Moment my.wH^3
Vertical Moment= mx.wH^3
Mid Span moment Edge moment
S NO X/H Coefficent Coefficent
Vertical Moment Horizontal Moment Vertical Moment Horizontal Moment
1 0 0.000 5.557 0.000 -10.584
2 0.25 2.117 5.292 -2.381 -11.642
3 0.5 4.234 4.234 -2.117 -11.113
4 0.75 -0.794 -1.588 -1.323 -6.880
5 1 -15.876 -3.175 0.000 0.000
Steel Required.
Mid Span Steel Required. Edge Steel Required
S NO X/H
Vertical steel Horizontal Steel Vertical SteelCoefficent
Horizontal Steel
1 0 0.00 532.40 0.00 652.06
2 0.25 50.38 526.11 56.68 677.25
3 0.5 100.76 500.92 50.38 664.65
4 0.75 18.89 437.94 31.49 563.89
5 1 377.86 475.73 0.00 400.15
Design of Water tank wall RW-3 for Soil Pressure
Freely supported
kN/m2
4.3
Value of Moment Coeffiecent
Tension in wall Note :-when sign +ve that means Moment in remote face.
when sign -ve that means Moment in water face..
Maximum Horizontal Tension = KwH^2 0 KN
Moment :- Horizontal Moment my.wH^3
Vertical Moment= mx.wH^3
Mid Span moment Edge moment
S NO X/H Coefficent Coefficent
Vertical Moment Horizontal Moment Vertical Moment Horizontal Moment
1 0 0.00 0.000 0.000 0.000
2 0.25 0.000 0.000 0.000 0.000
3 0.5 0.000 0.000 0.000 0.000
4 0.75 0.000 0.000 0.000 0.000
5 1 0.000 0.000 0.000 0.000
Steel Required
Important Cheack
Cheack for stress in steel
For Vertical Steel:-
p= 0.25 %
x/d= 0.18
fs(Bending)= 12.02 N/mm^2
Fs(Tension)= 0 N/mm^2
Total= 12.02 N/mm^2 Safe
For Horizontal Steel:-
p= 0.19 %
x/d= 0.79
fs(Bending)= 11.25 N/mm^2
Fs(Tension)= 68.90 N/mm^2
Total= 80.15 N/mm^2 Safe