ASSOC.

PIP Data Sheet for Low-Voltage Circuit Breaker ELSMC13D


ELSMC13 Motor Control Centers PAGE 1

Client       Engineering Org.       Spec. No.      

Project Title       Location       Date      


Project Location       Contract Number       Equip. No.      

Proj. No.       Specifier Name       Tele. No.      


P. O. No.      

Refer to Specification No. ELSMC13 for General Requirements


Applicable State and Local Codes:      

Data Provided by:  Buyer  Bidder with Proposal  Seller after Order

Site Conditions: Unit Options:


Altitude       ft. Seismic Zone    NEMA Wiring:
Ambient Temperature: Max.     C Min.     C Class 1 - Type B Other      
System Parameters: Control Power Transformers:
    V   Phase    Hertz   Wire 480/120 VAC Other      
Available Fault Current       Individual CPTs Other      
Incoming Line Power: Extra VA      
Line Enters: Overload Relays:
Top Bottom       Electro-Mechanical Electronic (Solid State)
Left Right Automatic Reset Ambient Compensated
Top Hat 12"    Line Connection Class 20 Class 10
Lugs Only Main Circuit Breaker       A Heaters Sized per Buyer’s Attachments
Without Heaters
Lugs: Motor Protection Devices:
Lugs by Seller Copper Aluminum Thermal-Magnetic Magnetic Only
Qty Wire(s) per Phase   Wire Size       AWG Adjustment Range:
MCC Enclosure: Per NEC Table Other      
NEMA: Accessories:
1 (Standard) 3R Drip-Proof Automatic Shutters
1A Gasket 12 Dust-Tight Provisions for Two-Hole Compression Lugs Units > 100 A
Outdoor Enclosure (See PIP ELSSG12) Unit Load Cable Lugs by Seller
Front Only Back-to-Back Space for Future Unit Internal Devices
15" Deep 20" Deep    Deep Surge Suppressors on Contactor Coils
Standard Finish Other Unit Devices      
Custom Finish            
Expansion Cover Plate(s) Required Left Right Door-Mounted Devices      
Horizontal Wireway Size 6" Min. Other            
Space Heater: Nameplates:
Required High-Temp Cutout Heater CB 1" x 2-1/2" (Std) Other      
Thermostat Control Test PB and Ammeter White Tag/Black Letters Other      
Main Power Bus: 3/16" Letters Other      
Bus Bracing: Engraved Plastic Other      
42,000 A 65,000 A       Door-Mounted Device Nameplate Located Inside Door
50,000 A 100,000 A Documentation:
Bus Material (Horizontal and Vertical): Schematic Diagrams:
Copper Aluminum Manufacturer’s Standard
Bus Joint Plating: By Buyer
Manufacturer Standard Electronic Document Format .DXF Other      
Tin-Plated Silver-Plated Other       Manufacturer to Provide:
Horizontal Power Bus:    Reproducible Plus
600 A 800 A 1000 A 1200 A    Number of Copies of All Documentation Plus
1600 A 2000 A 2500 A          Copies of the Operating Manuals
Vertical Power Bus: Additional Documentation Requirements:
300 A 600 A 450 A 800A            
Ground Bus:      
Size: Manufacturer Std. 1/4" x 1" Other            
Vertical Copper Ground Bus Other            
Horizontal Copper Ground Bus Top Bottom      
     
     
     