PIP Data Sheet for Low-Voltage Fused Switch ELSMC12D
ELSMC12 Motor Control Centers PAGE 1
Client Engineering Org. Spec. No.
Project Title Location Date
Project Location Contract Number Equip. No.
Proj. No. Specifier Name Tele. No.
P. O. No.
Refer to Specification No. ELSMC12 for General Requirements
Applicable State and Local Codes:
Data Provided by: Buyer Bidder with Proposal Seller after Order
Site Conditions: Unit Options:
Altitude ft. Seismic Zone NEMA Wiring: Ambient Temperature: Max. C Min. C Class 1 - Type B Other System Parameters: Control Power Transformers: V Phase Hertz Wire 480/120 VAC Other Available Fault Current Individual CPTs Other Incoming Line Power: Extra VA Line Enters: Overload Relays: Top Bottom Electro-Mechanical Electronic (Solid State) Left Right Automatic Reset Ambient Compensated Top Hat 12" Class 20 Class 10 Line Connection: Heaters Sized per Buyer’s Attachments Lugs Only Main Fused Switch A Without Heaters Lugs: Fused Switches: Lugs by Seller Copper Aluminum Five-Fault Test Qty Wire(s) per Phase Wire Size AWG Molded Case Switches Allowed For Rating Above A MCC Enclosure: Fuses: NEMA: Fuses per Attached Buyer’s Documentation 1 (Standard) 3R Drip-Proof Without Fuses 1A Gasket 12 Dust-Tight Class J Class L Class RKI Class RK5 Other Outdoor Enclosure (See PIP ELSSG12) Time Delay Fast Acting Front Only Back-to-Back Contactors – Size 4 and Above: 15" Deep 20" Deep Deep Magnetic Air Vacuum Standard Finish Accessories: Custom Finish Automatic Shutters Expansion Cover Plate(s) Required Left Right Provisions for Two-Hole Compression Lugs Units > 100 A Horizontal Wireway Size 6" Min. Other Unit Load Cable Lugs by Seller Space Heater: Space for Future Unit Internal Devices Required High-Temp Cutout Heater CB Surge Suppressors on Contactor Coils Thermostat Control Test PB and Ammeter Other Unit Devices Main Power Bus: Bus Bracing: Door-Mounted Devices 42,000 A 65,000 A 50,000 A 100,000 A Nameplates: Bus Material (Horizontal and Vertical): 1" x 2-1/2" (Std) Other Copper Aluminum White Tag/Black Letters Other Bus Joint Plating: 3/16" Letters Other Manufacturer Standard Engraved Plastic Other Tin-Plated Silver-Plated Other Door-Mounted Device Nameplate Located Inside Door Horizontal Power Bus: Documentation: 600 A 800 A 1000 A 1200 A Schematic Diagrams: 1600 A 2000 A 2500 A Manufacturer’s Standard Vertical Power Bus: By Buyer 300 A 600 A 450 A 800A Electronic Document Format .DXF Other
Ground Bus: Manufacturer to Provide: Size: Manufacturer Std. 1/4" x 1" Other Reproducible Plus Vertical Copper Ground Bus Other Number of Copies of All Documentation Plus Horizontal Copper Ground Bus Top Bottom Copies of the Operating Manuals Additional Documentation Requirements: