You are on page 1of 1

ASSOC.

PIP Data Sheet for Low-Voltage Fused Switch ELSMC12D


ELSMC12 Motor Control Centers PAGE 1

Client       Engineering Org.       Spec. No.      

Project Title       Location       Date      


Project Location       Contract Number       Equip. No.      

Proj. No.       Specifier Name       Tele. No.      


P. O. No.      

Refer to Specification No. ELSMC12 for General Requirements


Applicable State and Local Codes:      

Data Provided by:  Buyer  Bidder with Proposal  Seller after Order

Site Conditions: Unit Options:


Altitude       ft. Seismic Zone    NEMA Wiring:
Ambient Temperature: Max.     C Min.     C Class 1 - Type B Other      
System Parameters: Control Power Transformers:
    V   Phase    Hertz   Wire 480/120 VAC Other      
Available Fault Current       Individual CPTs Other      
Incoming Line Power: Extra VA      
Line Enters: Overload Relays:
Top Bottom       Electro-Mechanical Electronic (Solid State)
Left Right Automatic Reset Ambient Compensated
Top Hat 12"    Class 20 Class 10
Line Connection: Heaters Sized per Buyer’s Attachments
Lugs Only Main Fused Switch       A Without Heaters
Lugs: Fused Switches:
Lugs by Seller Copper Aluminum Five-Fault Test
Qty Wire(s) per Phase   Wire Size       AWG Molded Case Switches Allowed For Rating Above       A
MCC Enclosure: Fuses:
NEMA: Fuses per Attached Buyer’s Documentation
1 (Standard) 3R Drip-Proof Without Fuses
1A Gasket 12 Dust-Tight Class J Class L Class RKI Class RK5 Other    
Outdoor Enclosure (See PIP ELSSG12) Time Delay Fast Acting
Front Only Back-to-Back Contactors – Size 4 and Above:
15" Deep 20" Deep    Deep Magnetic Air Vacuum
Standard Finish Accessories:
Custom Finish       Automatic Shutters
Expansion Cover Plate(s) Required Left Right Provisions for Two-Hole Compression Lugs Units > 100 A
Horizontal Wireway Size 6" Min. Other       Unit Load Cable Lugs by Seller
Space Heater: Space for Future Unit Internal Devices
Required High-Temp Cutout Heater CB Surge Suppressors on Contactor Coils
Thermostat Control Test PB and Ammeter Other Unit Devices      
Main Power Bus:      
Bus Bracing: Door-Mounted Devices      
42,000 A 65,000 A            
50,000 A 100,000 A Nameplates:
Bus Material (Horizontal and Vertical): 1" x 2-1/2" (Std) Other      
Copper Aluminum White Tag/Black Letters Other      
Bus Joint Plating: 3/16" Letters Other      
Manufacturer Standard Engraved Plastic Other      
Tin-Plated Silver-Plated Other       Door-Mounted Device Nameplate Located Inside Door
Horizontal Power Bus: Documentation:
600 A 800 A 1000 A 1200 A Schematic Diagrams:
1600 A 2000 A 2500 A       Manufacturer’s Standard
Vertical Power Bus: By Buyer
300 A 600 A 450 A 800A       Electronic Document Format .DXF Other     

Ground Bus: Manufacturer to Provide:
Size: Manufacturer Std. 1/4" x 1" Other          Reproducible Plus
Vertical Copper Ground Bus Other          Number of Copies of All Documentation Plus
Horizontal Copper Ground Bus Top Bottom    Copies of the Operating Manuals
Additional Documentation Requirements:
     
     