BRUSH/COMMUTATOR WEAR GUIDE


Commutator Appearance Guide
GULF ELECTROQUIP In addition to the physical appearance of the surface of the commutator, the skin or patina (film) is of equal importance for the good running
POWER PRODUCTS of the carbon brushes. Each carbon brush builds a characteristic patina (film) which is affected by operating and ambient conditions. The
patina (film) consists mainly of copper oxides, graphite deposits and absorbed water, and its appearance is of importance for the
assessment of the running behavior of the commutation set. The following pictures are used by carbon brush manufacturers and users of
DRILLING MOTORS brushes as a guide to assist in judging the operation of carbon brushes.
Horizontal Traction, Mud Pump,
and Drawworks Motors
New GEQ 1150HP
Reman / Repair ­ GE, GEQ, EMD,
WEG, Yonge
Commutator Wear Guide
Full­Load Test / QC Docs
GEQ Parts Counter ­ Motors

TOP DRIVE MOTORS
Vertical Traction Motors
New GEQ 400HP LIGHT FILM: Indicates good brush MEDIUM FILM: Is the ideal HEAVY FILM: Results from high
Reman / Repair Motors ­ GE, GEQ, performance. Light load, low commutator condition for maximum load, light humidity or heavy filming
TSD11, WEG humidity, brush grades with low brush and commutator life. rate grades. Colors not in the brown
Commutator Wear Guide filming rates, or film reducing tones indicate contamination
Full­Load Test / QC Docs contamination can cause lighter resulting in high friction and high
GEQ Parts Counter ­ Motors color. resistance.

ROTARY TABLE MOTORS
Horizontal Traction Motors
New GEQ 400HP
Reman / Repair Motors ­ GE, GEQ,
TSD11
Full­Load Test / QC Docs
GEQ Parts Counter ­ Motors

GEQ MOTOR BLOWERS
For 400HP ­ 2000HP Hor. Traction, STREAKING: Results from metal THREADING: Is a further GROOVING: May result from an
Mud Pump and Drawworks Motors transfer to the brush face. Light loads development of the streaking overly abrasive brush grade. The
and/or light spring pressure are the condition as the metal transferred more common cause is poor
Double Clean™ most common causes. becomes work hardened and electrical contact resulting in arcing
Double Clean™SS Contamination can also be a machines into the commutator and the electrical machining of the
Quiet Clean™ contributing factor. surface. This condition can be commutator surface. Increased
Quiet Clean™SS avoided by increased loads and spring pressure reduces this
RainMaster™ increased spring pressure. electrical wear.
RainMaster™SS
ATEX Certified
ATEX Certified SS
For 400HP Vert. Top Drive Motors
Double Clean™ ­ Top Mount
Double Clean™ ­ Side Mount
For 400HP Hor. Rotary Table
Motors
Double Clean™ ­ Side Mount
GEQ Parts Counter ­ Blowers

GEQ BUG BLOWERS
Mighty Monsoon™
Mighty Monsoon™SS
GEQ Parts Counter ­ Mighty
Mini Monsoon™
Mini Monsoon™SS COPPER DRAG: Develops as the BAR EDGE BURNING: Results from SLOT BAR MARKING: Results from
GEQ Parts Counter ­ Mini commutator surface becomes poor commutation. Check 1.) that the a fault in the armature windings. The
GEQ Sales overheated and softened. Vibration brush grade has adequate voltage pattern relates to the number of
or an abrasive grade causes the drop, 2.) that the brushes are conductors per slot.
copper to be pulled across the slots. properly set on neutral, and 3.) that
O&G AC GENERATORS Increased spring pressure will the interpole strength is correct.
Reman / Repair ­ GE, Kato, ABB, reduce commutator temperature.
Baylor, CAT, EMD, Reliance,
Siemens, Toshiba, WEG Carbon Brush Performance Assessment
Full­Load Test / QC Docs
GEQ Parts Counter ­ AC Gen Notice the appearance of the brush sliding face. The following pictures show typical brush sliding faces. For easy identification, we suggest
you use the symbols S1, S3 etc. S1, S3 and S5 are satisfactory sliding faces, indicating that there are no mechanical or electrical problems.
Depending on the carbon material, the sliding surface appears dense or porous, and shiny, dull or matte. If there is dust in the circulating
AC & DC MOTORS 500HP+ air, fine hair­lining may occur, as shown in S5.
Large Motors ­ Industrial, Marine
and Commercial Normal operation
Reman / Repair
www.gulfelectroquip.com/technical.php?technicalname=commutator
S1 1/3
5/29/13 Gulf Electroquip - GE 752 Drilling Motors, AC Generators, Motor Blowers, Bug Blowers, Spark Arrestors
Reman / Repair S1
Dense, shining sliding face
GULF ELECTROQUIP
REMANUFACTURING,
REPAIR AND SERVICE
Facilities Tour
GEQ Product Line
Remanufacturing Normal operation
Full­Load Test / QC Docs S3
Customers
GEQ Sales Slight porous sliding face

Normal operation, slight dust influence
S5
Fine hairlining

GULF ELECTROQUIP S7 CAUSES:
PARTS COUNTER
Hairlining Underload, influence of dust, oil, or
CALL 24/7 ­ 713­675­2525 grease, weak spring pressure

parts@gulfelectroquip.com

S9 CAUSES:
Tracking with hairlining and grooves Like S7, but stronger

S11 CAUSES:
Ghostmarks, difficult commutation Commutation problems, e.g., false or
incorrect position of the neutral zone or
interpole

S13 CAUSES:
Burning edge of the leaving or trailing edge Difficult commutation, heavy sparking,
interruption of contact due to out of round
of commutator or insufficient brush holder
spring pressure

S15 CAUSES:
Eroded brush face Electrical overload, interruption of contact

S17 CAUSES:
Lamination of sliding face Burned segments of the sliding face,
caused by a winding fault giving voltage
surge during commutation

S19 CAUSES:
Double facing here for a twin brush Tilting of the brush in dual direction
machine

S21 CAUSES:
www.gulfelectroquip.com/technical.php?technicalname=commutator 2/3
5/29/13 Gulf Electroquip - GE 752 Drilling Motors, AC Generators, Motor Blowers, Bug Blowers, Spark Arrestors
S21 CAUSES:
Copper nests Pick up of copper particles, often following
copper drag

S23 CAUSES:
Broken edges High raised lamination, commutator
seriously out of round, brush chatter by
low load and idle running

Got Wear?
Are you experiencing similar symptoms of brush or commutator damage? If possible, you may take a photo of the damage and e­mail us
the image. This will help us to diagnose the cause and prescribe the solution.

Information courtesy of Helwig Carbon Products www.helwigcp.com

©2013 Gulf Electroquip Ltd. Houston, TX GULF ELECTROQUIP.  DELIVERING HIGH­QUALITY PRODUCTS AND SERVICES FOR 57 YEARS E­mail: sales@gulfelectroquip.com

DISCLAIMER: Product specifications and availability are subject to change without notice. Statements in this website or digital publication PDFs are not intended to create any warranty ­ expressed or implied.
Product trade names, marks or logos are the property of their respective owners. All photography and illustrations are copyrighted by Gulf Electroquip.

www.gulfelectroquip.com/technical.php?technicalname=commutator 3/3