Installation procedure
The pictures and drawings are for an F module, but this document is also valid for C and Sl modules
with latched mechanism
Bilder og tegninger er av et F-felt, men dette dokumentet er også gyldig for C- og Sl-felt med forspent
fjær

Operating Operating Operating Operating


springs springs springs springs
not charged charged not charged charged
Koblingsfjærer Koblingsfjærer
ikke forspent forspent
Koblingsfjærer Koblingsfjærer
ikke forspent forspent

Used until May 2007 Existing front covers


Brukt inntil mai 2007 Dagens frontdeksler

1. Operate the switch-fuse-disconnector to open position


Betjen lastbryteren til utkoblet stilling

2. Verify that the operating springs are not charged


Kontroller at koblingsfjærene ikke er forspente

3. Operate the earthing switch to closed position


Betjen jordslutter til innkoblet posisjon

4. Unscrew the fixing screw and remove the upper front cover
Løsne festeskruen og fjern det øvre frontdekselet

5. Open the lower front cover


Åpne det nedre frontdekselet