You are on page 1of 4

CE162P RSEU1

CE162P
Principles of Foundation Design

Please Be Reminded
1. Don’t Do Harm To Others and To Yourself
2. Maintain Academic Integrity
3. Strengthen Ethical Principles And Moral Imperatives
4. Remember The Honor Code Deeply Embedded Through Your Veins
5. Act Not On The Spectacles Of Peer Pressure But On The Lens Of Dignified Trait
6. Submit your clear pdf solution to rolandojquitalig@gmail.com AND TO rjquitalig@mapua.edu.ph
Subject/Filename: (e.g RSEU1 CE162P E01 1Q2223 SN GN MI)
Due @ most 10.15.22
CE162P
Principles of Foundation Design

1. Design a square column footing for a 16-in. square tied interior column that supports a dead
load PD = 200 k and a live load PL = 160 k. The column is reinforced with eight #8 bars, the base
of the footing is 5 ft below grade, the soil weight is 100 lb/ft3, fy = 60,000 psi, fc’ = 3000 psi, and
qa = 5000 psf. Check for one way shear, punching shear, and development length. The solution
must be in SI Units.

2. Design a rectangular footing for an 18-in. square interior column with a dead load of 185 k and
RSEU1

a live load of 150 k. Make the length of the long side equal to twice the width of the short side, fy =
60,000 psi, fc’ = 4000 psi, normal weight, and qa = 4000 psf. Assume the base of the footing is 5
ft below grade. Check for one way shear, punching shear, and development length. The solution
must be in SI Units.

3. Design a wall footing to support a 12-in.-wide reinforced concrete wall with a dead load D = 20
k/ft and a live load L = 15 k/ft. The bottom of the footing is to be 4 ft below the final grade, the soil
weighs 100 lb/ft3, the allowable soil pressure, qa, is 4 ksf, and fy = 60 ksi and fc’ = 3 ksi,
normal-weight concrete. Check for shear and development length. The solution must be in SI
Units.
CE162P
Principles of Foundation Design

4. Determine the width needed for a wall footing to support loads: D = 263 KN/m and L = 176 KN/m.
In addition, a moment of 53 KN m must be transferred from the column to the footing. Assume the
footing is 450 mm. thick, its base is 1.5 m below the final grade, and qa = 192 KPa.
RSEU1

5. Design a reinforced concrete wall footing to support a 300-mm-wide reinforced concrete wall with
a dead load D = 300 kN/m and a live load L = 200 kN/m. The bottom of the footing is to be 1 m
below the final grade, the soil weight is 16 kN/m3, the concrete weight is 24 kN/m3, the allowable soil
pressure, qa is 190 KPa, fy = 420 MPa, and fc’ = 28 MPa.

6. Design a footing with one side limited to 2.12 m for the following: 300mm x 300mm. edge column,
D = 578 KN, L = 689 KN, fc’ = 20.7 MPa, fy = 414 MPa, qa = 192 KPa, and a distance from top of
backfill to bottom of footing = 1.5 m.