You are on page 1of 1

Wismar University • Department of Maritime studies - ITS

Module: Ships electrical installation


Prof. Dr.-Ing. A. Rafoth

EM 09  Diagnosis ASM 
 
1. Introduction  Measured values:
 

Errors sometimes occur in electrical machines. These may  R1 windingresistance
be, for example: winding interruption, housing short  IN rated current
circuit or winding short circuit. In the experiment, analysis  Risolation insulationresistance
methods are used for different engines in order to find 
errors. 
 
2. Preparation for laboratory (homework) 
 

 Repeat the structure and theory of asynchronous machines! 
  What is a resistor measuring bridge, how does it work? 
 What are windings in electrical machines, what is their function? 
 How does an electronic milliohm meter work? How is a compensation resistance 
measurement carried out with sense lines? 
 How is the insulation resistance measured when testing electrical systems, what values are 
required according to  standards (e.g. for a 400V system)? 
 
3. Experiments / Investigation 
3.1. Determine the value of a reference resistance with a digital multimeter, with a resistance 
measuring bridge, with a milliohm meter and by a current‐voltage measurement 
3.2. Determine the resistance of the three phase windings of three existing asynchronous 
machines. 
3.3. Measure the insulation resistances of the windings to each other and to the housing. 
3.4. Find three errors on the diagnosis asynchronous machine (they are set beforehand by the 
laboratory supervisor). 
 
4. Analysis / reporting 
 

4.1. Report the resistance measurement results for the reference resistor. 
4.2. Displaying the resistance measurement results for the winding resistances. Discussion of 
the measuring method/device used. 
4.3. Presentation of the measurement results for the insulation resistance. 
4.4. Report the errors simulated in model motor and the applied characteristic measurements! 
 
5. Equipment:  
 Thomson measuring bridge with suitable power supply 
 Milliohm meter,  
 24V‐power supply , load resistance for currents >1A 
 Digital multimeter (DMM) 
 Isolationsmeter (manufacturer  Metrawatt) 
 Three differenc  asynchronous motors 
 asynchronous motors with  simulator of errors for training of diagnosis (Leybold) 
 

Stand: 23.05.22 EM09_Diagnosis ASM_e.doc