Transporting stormwater
Table of contents
TRANSPORT TREATMENT STORAGE DISCHARGE TRANSPORT TREATMENT STORAGE DISCHARGE Infiltration water in track drainage 17
Surface water in urban drainage 19
4 CHALLENGES – 1 SOLUTION
STORMWATER IS OUR COMPETENCE.
www.fraenkische.com
Competence brochure – 1 – Transporting stormwater 5
Where stormwater cannot be dis- Drainage and transport pipes are used
charged naturally, it needs to be reliably to collect, channel or discharge the
collected and then discharged in a con- different types and amounts of water.
trolled way.
Properly functioning drainage is one of
the crucial requirements for reliable
For traffic areas water often …
usability and long service life of roads
■ is a hindrance and causes danger to and tracks.
road users (e.g., due to aquaplaning,
icing in winter) Safety from the very beginning
■ causes damage to the pavement The approach by FRÄNKISCHE encom-
(e.g., due to washing-out or frost passes transport, treatment, storage
damage) and discharge of stormwater. These four
tasks are reflected in our stormwater
Drainage systems help to collect and Note
management. This is how precipitation
discharge surface water, water from the
water is re-channelled back to natural Collected road surface water is consid-
soil and/or road superstructure, and
storage areas – both economically and ered wastewater according to the Feder-
water coming from external sources.
ecologically. al Water Act (Wasserhaushaltsgesetz
– WHG). As a general rule, wastewater
must be transported through leak-tight
pipes.
Competence brochure – 1 – Transporting stormwater 7
Strabusil®
Infiltration water in Strasil®
road drainage StormPipe
SUPPOSED TO BE TRANSPORTED?
Infiltration water in RailPipe® system
track drainage
roduct documentation
P
www.fraenkische.com
12 Competence brochure – 1 – Transporting stormwater Competence brochure – 1 – Transporting stormwater 13
roduct documentation
P
www.fraenkische.com
14 Competence brochure – 1 – Transporting stormwater Competence brochure – 1 – Transporting stormwater 15
Overview of flushing and inspection shafts for road drainage Product StrabuControl HP StrabuControl 600 HP
StrabuControl
600 V HP
AquaTrafficControl HP
AquaTrafficControl
V HP
Extension pipe
Inside diame- 400 600 600 600 600
DO
ter of base > 500 mm > 600 mm > 600 mm > 900 mm > 900 mm
body 2/300, 2/400, 2/500,
2/250, 3/250, 2/350 2/250, 2/350
Variable shaft angle 2/600, 300/400, Variable shaft angle
Extension pipe Designs 2/250–150 (90°) 2/250–150 (90°)
400 600 600 600 600 90–270 degrees 400/500, 300, 400, 90–270 degrees
DO 2/350–150 (90°) 2/350–150 (90°)
500, 600
2/300, 2/400, 2/500, Transport pipe1) AquaPipe AquaPipe AquaPipe AquaPipe AquaPipe
2/250, 2/400,
2/250, 3/250, 4/250, Variable shaft angle 2/600, 300/400, Variable shaft angle
Designs 2/250–150 (90°)
3/350, 4/350, 2/400 90–270 degrees 400/500, 500/600, 90–270 degrees Nominal
2/400–150 (90°)
300, 400, 500, 600 connection
DN 200–350 DN 200–350 DN 200–350 DN 300–600 DN 300–600
Strasil Strasil diameters of
Strasil transport pipe
Connectable Strabusil Strabusil AquaPipe AquaPipe
Strabusil
types of pipe1) StormPipe StormPipe StormPipe StormPipe
StormPipe Strabusil Strabusil Strabusil Strabusil Strabusil
AquaPipe AquaPipe Drainage pipe
StormPipe StormPipe StormPipe StormPipe StormPipe
Available nomi-
nal connection DN 100–400 DN 100–400 DN 100–400 DN 300–600 DN 300–600 Nominal
diameters connection
DN 150 DN 150 DN 150 DN 150 DN 150
diameters of
drainage pipe
FRÄNKISCHE Standard cover Standard cover Standard cover Standard cover
Cover FRÄNKISCHE Standard cover Standard cover Standard cover Standard cover
(470 mm) (625 mm), on site (625 mm), on site (625 mm), on site (625 mm), on site Cover
(470 mm) (625 mm), on site (625 mm), on site (625 mm), on site (625 mm), on site
1)
Other FRÄNKISCHE structured-wall pipes possible 1)
Other FRÄNKISCHE structured-wall pipes possible
16 Competence brochure – 1 – Transporting stormwater Competence brochure – 1 – Transporting stormwater 17
Infiltration water must also be appropri- Both the shaft body and the extremely
ately collected and discharged from rail- durable and hard-wearing SN 16
way tracks. The DBS 918064 directive extension pipe have an inside diameter
of Deutsche Bahn AG specifies the of 600 mm. In addition, standard
demands that are placed on drainage 625 mm covers can be used. RailPipe
systems in detail with a focus on highest and RailControl meet all technical
safety. requirements of DBS 918064 and feature
the HPQ manufacturer-related product
RailPipe exceeds the standards set in
qualification. The EBA approval makes
the DBS directive and is available as a RailPipe drainage pipe
the complete RailPipe system the first
locally perforated pipe and a totally
structured-wall pipe system to be certi- ■ PP material, new item
perforated pipe in various nominal
fied by the Federal Railway Authority for ■ 3.5 mm inside wall thickness
diameters. The ring stiffness of SN 8
installation in the internal pressure range. ■ 2.5 mm perforation width
stipulated by Deutsche Bahn has been
doubled by FRÄNKISCHE to SN 16. RailControl shaft
RailPipe ® RailControl Application
The RailPipe system is complemented ■ Monolithic base body
The RailPipe system has specifically
FRÄNKISCHE FRÄNKISCHE
Proof of by the innovative RailControl flushing ■ Ø 600 mm inside diameter
been designed to collect and transport
Zulassung
Zulassung 21.41 - 21.42-21izbit/011-2101#075
jetting
Izbit 032/15
resistance able both as a 180° shaft in two basic ■ Proof of jetting resistance acc.
In the field of urban drainage, surface The SN 16 pipe exceeds the require-
water, e.g., from streets and squares ments of DIN EN 13476 thanks to its
must also be discharged. continuous inside wall thickness of
3.5 mm. Even extreme soil and traffic Robukan SMR
SN 8
DIN EN 13476-compliant Robukan SMR loads pose no problem.
provides an optimum and economical
solution to the tasks of urban drainage. Application
As a stormwater pipe for stormwater Robukan SMR
More reliability due to higher stiffness SN 16
runoff from roads, alleys and squares
The Robukan SMR pipe system is
available in two stiffness classes: Components
SN 8 (yellow inside) and SN 16 (orange
Robukan SMR SN 8, SN 16, RobuDock, ■ Complies with DIN EN 13476
inside). The actual ring stiffness of SN 8
RobuControl, RainControl
pipes amounts to as much as ≥ 10 kN/m² ■ PP material, new item
(“SN10”).
■ Leak tightness of at least 2.4 bar
roduct documentation
P
www.fraenkische.com
TRANSPORT TREATMENT STORAGE DISCHARGE
FRÄNKISCHE Rohrwerke Gebr. Kirchner GmbH & Co. KG | Hellinger Str. 1 | 97486 Königsberg / Germany
Phone +49 9525 88-2200 | Fax +49 9525 88-92200 | marketing@fraenkische.de | www.fraenkische.com
EN.90097/1.09.21 | Subject to change without notice | Cat. no. 5000-0900-00X | 09/2021 [DE.90097/1.04.21]