You are on page 1of 4

Project No.

Date

General 28/4/02
DESIGN CALCULATION
SHEET Sheet No. Computed by

of -- A. HASHEM
Checked by Approved by
Subject Checking
_ _
Building Test1

Calculation of Deflection According to ACI 318M-99


Concrete Compressive Strength (f'c) = 200.00 Kg/cm2 = 20.00 MPa
Concrete Modulus of Rupture (fr) = 3.13 MPa (Eq. 9-9)
Concrete Modulus of Elasticity (Ec) = 2.1E+04 MPa (Clause 8.5.1)
n (Es/Ec) = 9.52 (Clause 8.5.2)
Section Properties
Thickness of Section (t) = 32.00 cm Depth of Ten. Reinforcement (d) = 28.60 cm
Breadth of Section (b) = 140.00 cm Depth of Comp. Reinforcement (d') = 3.40 cm
Tension Reinforcement (As) = 44.22 cm 2 Compression Reinforcement (As') = 20.10 cm2
Span (l) = 7.00 m
Nutral Axis Depth (z) = 9.85 cm
Gross Moment of Inertia (Ig) = 382293.33 cm4 = 3.82E+09 mm4
Cracked Moment of Inertial (Icr) = 199642.40 cm 4 = 2.00E+09 mm4
Cracking Moment (Mcr) = 7.48E+07 N mm = 7.48 m. t (Eq. 9-8)
Service Straining Actions
Bending Moment Due to Dead Load only (Md) = 23.60 m.t = 2.4E+08 N. mm
Bending Moment Due to Live Load only (Ml) = 3.40 m.t = 3.4E+07 N. mm
% of Sustained Load from the Live Load = 25%
% of Gross Inertia Used in Calculation = 100%
Bending Moment Due to Sustained Load (Msus) = 24.45 m.t = 2.4E+08 N. mm
Calculated Short Time Deflection (Calculated by total or percentage of gross moment of inertia)
Deflection due to Dead Load (Di)d = 0.6000 cm = 6.000 mm
Deflection due to Live Load (Di)l = 0.4000 cm = 4.000 mm
Efffective Moment of Inertia (Eq. 9-7)
Under Dead Load Only (Ie)d = 205457.47 cm4 = 2.05E+09 mm4
Under Sustained Load (Ie)sus = 204871.83 cm4 = 2.05E+09 mm4
Under Dead + Live Load (Ie)d+l = 203525.689 cm4 = 2.04E+09 mm4
Modified Short time Deflection
Deflection due to Dead Load (Di)d = 1.1164 cm
Deflection due to Sustained Load (Di)sus = 1.3062 cm
Deflection due to Dead + Live Load (Di)d+l = 1.8784 cm
Deflection due to Live Load (Di)l = 0.7619 cm
Additional Long Term Deflection (Clause 9.5.2.5)
For 5 years or more (Dlong) = 2.08826 cm For 12 months (Dlong) = 1.46179 cm
For 6 months (Dlong) = 1.25296 cm For 3 months (Dlong) = 1.04413 cm

Results
-- Flat roofs not supporting and not attached to nonstructural elements likely to be damaged by large defelections:
(Di)l = 0.7619 cm < l/180 = 3.8889 cm
-- Floors not supporting and not attached to nonstructural elements likely to be damaged by large deflections:
(Di)l = 0.7619 cm < l/360 = 1.9444 cm
-- Roof or floor construction supporting or attached to nonstructural elements likely to be damaged by
large deflections:
(Dlong) + (Di)l = 2.8502 cm > l/480 = 1.45833 cm
-- Roof or floor construction supporting or attached to nonstructural elements not likely to be damaged by

622622985.xls - Rev. 0 Rectangular Section


large deflections:
(Dlong) + (Di)l = 2.8502 cm < l/240 = 2.9167 cm

622622985.xls - Rev. 0 Rectangular Section


Project No. Date

General 28/4/02
DESIGN CALCULATION
SHEET Sheet No. Computed by

of -- A. HASHEM
Checked by Approved by
Subject Checking
_ _
Building Test2

Calculation of Deflection According to ACI 318M-99


Concrete Compressive Strength (f'c) = 210.00 Kg/cm2 = 21.00 MPa
Concrete Modulus of Rupture (fr) = 3.21 MPa (Eq. 9-9)
Concrete Modulus of Elasticity (Ec) = 2.2E+04 MPa (Clause 8.5.1)
n (Es/Ec) = 9.29 (Clause 8.5.2)
Section Properties
Thickness of Section (t) = 40.00 cm Depth of Ten. Reinforcement (d) = 28.60 cm
Breadth of Wib (bw) = 30.00 cm Depth of Comp. Reinforcement (d') = 2.50 cm
Breadth of Flange (bf) = 60.00 cm Flange Thickness (tf) = 7.00 cm
Tension Reinforcement (As) = 6.03 cm 2 Compression Reinforcement (As') = 2.26 cm2
Span (l) = 7.00 m
Nutral Axis Depth (z) = 6.29 cm
Gross Moment of Inertia (Ig) = 209514.95 cm4 = 2.10E+09 mm4
Cracked Moment of Inertial (Icr) = 33116.24 cm 4 = 3.31E+08 mm4
Cracking Moment (Mcr) = 2.99E+07 N mm = 2.99 m. t (Eq. 9-8)
Service Straining Actions
Bending Moment Due to Dead Load only (Md) = 3.80 m.t = 3.8E+07 N. mm
Bending Moment Due to Live Load only (Ml) = 0.49 m.t = 4.9E+06 N. mm
% of Sustained Load from the Live Load = 30%
% of Gross Inertia Used in Calculation = 100%
Bending Moment Due to Sustained Load (Msus) = 3.9519 m.t = 4.0E+07 N. mm
Calculated Short Time Deflection (Calculated by total or percentage of gross moment of inertia)
Deflection due to Dead Load (Di)d = 1.0000 cm = 10.000 mm
Deflection due to Live Load (Di)l = 0.5000 cm = 5.000 mm
Efffective Moment of Inertia (Eq. 9-7)
Under Dead Load Only (Ie)d = 118948.91 cm4 = 1.19E+09 mm4
Under Sustained Load (Ie)sus = 109722.54 cm4 = 1.10E+09 mm4
Under Dead + Live Load (Ie)d+l = 92795.4631 cm4 = 9.28E+08 mm4
Modified Short time Deflection
Deflection due to Dead Load (Di)d = 1.7614 cm
Deflection due to Sustained Load (Di)sus = 2.1959 cm
Deflection due to Dead + Live Load (Di)d+l = 3.3867 cm
Deflection due to Live Load (Di)l = 1.6253 cm
Additional Long Term Deflection (Clause 9.5.2.5)
For 5 years or more (Dlong) = 3.88074 cm For 12 months (Dlong) = 2.71652 cm
For 6 months (Dlong) = 2.32845 cm For 3 months (Dlong) = 1.94037 cm

Results
-- Flat roofs not supporting and not attached to nonstructural elements likely to be damaged by large defelections:
(Di)l = 1.6253 cm < l/180 = 3.8889 cm
-- Floors not supporting and not attached to nonstructural elements likely to be damaged by large deflections:
(Di)l = 1.6253 cm < l/360 = 1.9444 cm
-- Roof or floor construction supporting or attached to nonstructural elements likely to be damaged by
large deflections:
(Dlong) + (Di)l = 5.5061 cm > l/480 = 1.45833 cm

622622985.xls - Rev. 0 T - Section


-- Roof or floor construction supporting or attached to nonstructural elements not likely to be damaged by
large deflections:
(Dlong) + (Di)l = 5.5061 cm > l/240 = 2.9167 cm

622622985.xls - Rev. 0 T - Section

You might also like