Date
General 28/4/02
DESIGN CALCULATION
SHEET Sheet No. Computed by
of -- A. HASHEM
Checked by Approved by
Subject Checking
_ _
Building Test1
Results
-- Flat roofs not supporting and not attached to nonstructural elements likely to be damaged by large defelections:
(Di)l = 0.7619 cm < l/180 = 3.8889 cm
-- Floors not supporting and not attached to nonstructural elements likely to be damaged by large deflections:
(Di)l = 0.7619 cm < l/360 = 1.9444 cm
-- Roof or floor construction supporting or attached to nonstructural elements likely to be damaged by
large deflections:
(Dlong) + (Di)l = 2.8502 cm > l/480 = 1.45833 cm
-- Roof or floor construction supporting or attached to nonstructural elements not likely to be damaged by
General 28/4/02
DESIGN CALCULATION
SHEET Sheet No. Computed by
of -- A. HASHEM
Checked by Approved by
Subject Checking
_ _
Building Test2
Results
-- Flat roofs not supporting and not attached to nonstructural elements likely to be damaged by large defelections:
(Di)l = 1.6253 cm < l/180 = 3.8889 cm
-- Floors not supporting and not attached to nonstructural elements likely to be damaged by large deflections:
(Di)l = 1.6253 cm < l/360 = 1.9444 cm
-- Roof or floor construction supporting or attached to nonstructural elements likely to be damaged by
large deflections:
(Dlong) + (Di)l = 5.5061 cm > l/480 = 1.45833 cm