You are on page 1of 4

Project No.

Date

General 28/4/02
DESIGN CALCULATION
SHEET Sheet No. Computed by

of -- A. HASHEM
Checked by Approved by
Subject Checking
_ _
Building Test1

Calculation of Deflection According to ACI 318M-99


Concrete Compressive Strength (f'c) = 300.00 Kg/cm2 = 30.00 MPa
Concrete Modulus of Rupture (fr) = 3.83 MPa (Eq. 9-9)
Concrete Modulus of Elasticity (Ec) = 2.6E+04 MPa (Clause 8.5.1)
n (Es/Ec) = 7.77 (Clause 8.5.2)
Section Properties
Thickness of Section (t) = 60.00 cm Depth of Ten. Reinforcement (d) = 55.00 cm
Breadth of Section (b) = 30.00 cm Depth of Comp. Reinforcement (d') = 5.00 cm
Tension Reinforcement (As) = 8.00 cm 2 Compression Reinforcement (As') = 2.62 cm2
Span (l) = 5.00 m
Nutral Axis Depth (z) = 12.86 cm
Gross Moment of Inertia (Ig) = 540000.00 cm4 = 5.40E+09 mm4
Cracked Moment of Inertial (Icr) = 132733.36 cm 4 = 1.33E+09 mm4
Cracking Moment (Mcr) = 6.90E+07 N mm = 6.90 m. t (Eq. 9-8)
Service Straining Actions
Bending Moment Due to Dead Load only (Md) = 5.00 m.t = 5.0E+07 N. mm
Bending Moment Due to Live Load only (Ml) = 3.50 m.t = 3.5E+07 N. mm
% of Sustained Load from the Live Load = 50%
% of Gross Inertia Used in Calculation = 100%
Bending Moment Due to Sustained Load (Msus) = 6.75 m.t = 6.8E+07 N. mm
Calculated Short Time Deflection (Calculated by total or percentage of gross moment of inertia)
Deflection due to Dead Load (Di)d = 0.6000 cm = 6.000 mm
Deflection due to Live Load (Di)l = 0.4000 cm = 4.000 mm
Efffective Moment of Inertia (Eq. 9-7)
Under Dead Load Only (Ie)d = 540000.00 cm4 = 5.40E+09 mm4
Under Sustained Load (Ie)sus = 540000.00 cm4 = 5.40E+09 mm4
Under Dead + Live Load (Ie)d+l = 350712.822 cm4 = 3.51E+09 mm4
Modified Short time Deflection
Deflection due to Dead Load (Di)d = 0.6000 cm
Deflection due to Sustained Load (Di)sus = 0.8000 cm
Deflection due to Dead + Live Load (Di)d+l = 1.5397 cm
Deflection due to Live Load (Di)l = 0.9397 cm
Additional Long Term Deflection (Clause 9.5.2.5)
For 5 years or more (Dlong) = 1.48231 cm For 12 months (Dlong) = 1.03762 cm
For 6 months (Dlong) = 0.88939 cm For 3 months (Dlong) = 0.74116 cm

Results
-- Flat roofs not supporting and not attached to nonstructural elements likely to be damaged by large defelections:
(Di)l = 0.9397 cm < l/180 = 2.7778 cm
-- Floors not supporting and not attached to nonstructural elements likely to be damaged by large deflections:
(Di)l = 0.9397 cm < l/360 = 1.3889 cm
-- Roof or floor construction supporting or attached to nonstructural elements likely to be damaged by
large deflections:
(Dlong) + (Di)l = 2.4220 cm > l/480 = 1.04167 cm
-- Roof or floor construction supporting or attached to nonstructural elements not likely to be damaged by

718176913.xls - Rev. 0 Rectangular Section


large deflections:
(Dlong) + (Di)l = 2.4220 cm > l/240 = 2.0833 cm

718176913.xls - Rev. 0 Rectangular Section


Project No. Date

General 28/4/02
DESIGN CALCULATION
SHEET Sheet No. Computed by

of -- A. HASHEM
Checked by Approved by
Subject Checking
_ _
Building Test2

Calculation of Deflection According to ACI 318M-99


Concrete Compressive Strength (f'c) = 250.00 Kg/cm2 = 25.00 MPa
Concrete Modulus of Rupture (fr) = 3.50 MPa (Eq. 9-9)
Concrete Modulus of Elasticity (Ec) = 2.4E+04 MPa (Clause 8.5.1)
n (Es/Ec) = 8.51 (Clause 8.5.2)
Section Properties
Thickness of Section (t) = 70.00 cm Depth of Ten. Reinforcement (d) = 65.00 cm
Breadth of Wib (bw) = 30.00 cm Depth of Comp. Reinforcement (d') = 5.00 cm
Breadth of Flange (bf) = 120.00 cm Flange Thickness (tf) = 15.00 cm
Tension Reinforcement (As) = 8.00 cm2 Compression Reinforcement (As') = 2.62 cm2
Span (l) = 5.00 m
Nutral Axis Depth (z) = 9.29 cm
Gross Moment of Inertia (Ig) = 1504252.72 cm4 = 1.50E+10 mm4
Cracked Moment of Inertial (Icr) = 243737.77 cm 4 = 2.44E+09 mm4
Cracking Moment (Mcr) = 1.15E+08 N mm = 11.51 m. t (Eq. 9-8)
Service Straining Actions
Bending Moment Due to Dead Load only (Md) = 10.00 m.t = 1.0E+08 N. mm
Bending Moment Due to Live Load only (Ml) = 8.00 m.t = 8.0E+07 N. mm
% of Sustained Load from the Live Load = 30%
% of Gross Inertia Used in Calculation = 100%
Bending Moment Due to Sustained Load (Msus) = 12.4 m.t = 1.2E+08 N. mm
Calculated Short Time Deflection (Calculated by total or percentage of gross moment of inertia)
Deflection due to Dead Load (Di)d = 1.0000 cm = 10.000 mm
Deflection due to Live Load (Di)l = 0.5000 cm = 5.000 mm
Efffective Moment of Inertia (Eq. 9-7)
Under Dead Load Only (Ie)d = 1504252.72 cm4 = 1.50E+10 mm4
Under Sustained Load (Ie)sus = 1250592.20 cm4 = 1.25E+10 mm4
Under Dead + Live Load (Ie)d+l = 572903.203 cm4 = 5.73E+09 mm4
Modified Short time Deflection
Deflection due to Dead Load (Di)d = 1.0000 cm
Deflection due to Sustained Load (Di)sus = 1.3833 cm
Deflection due to Dead + Live Load (Di)d+l = 3.9385 cm
Deflection due to Live Load (Di)l = 2.9385 cm
Additional Long Term Deflection (Clause 9.5.2.5)
For 5 years or more (Dlong) = 2.59236 cm For 12 months (Dlong) = 1.81465 cm
For 6 months (Dlong) = 1.55542 cm For 3 months (Dlong) = 1.29618 cm

Results
-- Flat roofs not supporting and not attached to nonstructural elements likely to be damaged by large defelections:
(Di)l = 2.9385 cm > l/180 = 2.7778 cm
-- Floors not supporting and not attached to nonstructural elements likely to be damaged by large deflections:
(Di)l = 2.9385 cm > l/360 = 1.3889 cm
-- Roof or floor construction supporting or attached to nonstructural elements likely to be damaged by
large deflections:
(Dlong) + (Di)l = 5.5309 cm > l/480 = 1.04167 cm

718176913.xls - Rev. 0 T - Section


-- Roof or floor construction supporting or attached to nonstructural elements not likely to be damaged by
large deflections:
(Dlong) + (Di)l = 5.5309 cm > l/240 = 2.0833 cm

718176913.xls - Rev. 0 T - Section