PREPARED BY DATE TITLE
D.H.Ahn NOV.30.'18
INSULATION DATA SHEET FOR
CHECKED BY DATE
DEAERATOR AND FEED WATER STORAGE TANK
H.E.Lee NOV.30.'18
APPROVED DATE CONTRACTOR DOCUMENT NUMBER REV.
1 MINERAL WOOL BLANKET TYPE II of ASTM C592 37.5m2(t100) m2 DENSITY : 120 kg/cm2
ALUMINUM SHEET
2 ASTM B209 48.8m2(1000W x 0.5t) m2
(JACKET)
SUS WIRE for
3 304 S.S Ø1.6 x 180m m PITCH 225
MINERAL WOOOL
Note 1. This Insulation data sheet and calculation shall be complied with Contract
[BOOK III_4.6.1.3_INSULATION FOR PIPING AND EQUIPMENT].
INSULATION THICKNESS CALCULATION FOR DEAERATOR
INPUT DATA
* Design Limit(설계
* Vessel O.D 1628 mm 50 °C
조건<이하)
RESULT OF CALCULATION
* Vessel O.R, r1 0.814 m
* JUDGEMENT O.K!
* ψ1=10 for Pipe or Vessel(form internal fluid temperature to internal surface temperature),
* ψ2=10 (convection of external insulation surface)
INSULATION
BOM OF INS. FOR ONE SET / STORAGE TANK PJT : KALSELTENG 2 CFSPP
1 MINERAL WOOL BLANKET TYPE II of ASTM C592 114.4m2(t100) m2 Density : 120 kg/cm2
ALUMINUM SHEET
2 ASTM B209 148.8m2(1000W x 0.8t) m2
(JACKET)
SUS WIRE for
3 304 S.S Ø1.6 x 374m m PITCH 225
MINERAL WOOOL
Note 1. This Insulation data sheet and calculation shall be complied with Contract
[BOOK III_4.6.1.3_INSULATION FOR PIPING AND EQUIPMENT].
INSULATION THICKNESS CALCULATION FOR STORAGE TANK
INPUT DATA
* Design Limit(설계
* Vessel O.D 2632 mm 50 °C
조건<이하)
RESULT OF CALCULATION
* Vessel O.R, r1 1.316 m
* JUDGEMENT O.K!
* ψ1=10 for Pipe or Vessel(form internal fluid temperature to internal surface temperature),
* ψ2=10 (convection of external insulation surface)
INSULATION