You are on page 1of 1

Bushing’s condition effect

According to the relevant standards, SFRA tests must be performed with the same
transformer configuration to get repeatable results. Sometimes, different transformer
bushings could be used during factory acceptance tests and on-site tests, or for some reason,
the bushings could be replaced on the transformer during the service life. SFRA tests on
different bushings may cause differences in the high frequencies, as shown in Figure 4.

You might also like