Professional Documents
Culture Documents
80
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Indonesia.html
Company: Page: 1
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Copy - KSB-PTPTP-P2207109-ENG-001 R2 NM610 Date: 21/10/2022
Fastening point:
Specifier's comments:
1 Input data
Anchor type and diameter: HIT-RE 500 V3 + HAS-U 5.8 M12
Item number: 2223823 HAS-U 5.8 M12x160 (element) / 2123403
HIT-RE 500 V3 (adhesive)
Effective embedment depth: hef,act = 110.0 mm (hef,limit = - mm)
Material: 5.8
Evaluation Service Report: ESR-3814
Issued I Valid: 01/03/2021 | 01/01/2023
Proof: Design Method ACI 318-14 / Chem
Stand-off installation: eb = 0.0 mm (no stand-off); t = 16.0 mm
Anchor plate :
R lx x ly x t = 2,700.0 mm x 1,000.0 mm x 16.0 mm; (Recommended plate thickness: not calculated)
Profile: no profile
Base material: uncracked concrete, , fc' = 3,626 psi; h = 500.0 mm, Temp. short/long: 40/24 °C
Installation: hammer drilled hole, Installation condition: Dry
Reinforcement: tension: condition B, shear: condition B; no supplemental splitting reinforcement present
edge reinforcement: none or < No. 4 bar
Application also possible with HVU2 + HAS-U 5.8 M12 under the selected boundary conditions.
More information in section Alternative fastening data of this report.
R
- The anchor calculation is based on a rigid anchor plate assumption.
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
1
Hilti PROFIS Engineering 3.0.80
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Indonesia.html
Company: Page: 2
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Copy - KSB-PTPTP-P2207109-ENG-001 R2 NM610 Date: 21/10/2022
Fastening point:
Anchor forces are calculated based on the assumption of a rigid anchor plate.
3 Tension load
Load Nua [kN] Capacity f Nn [kN] Utilization bN = Nua/f Nn Status
Steel Strength* 4.226 27.300 16 OK
Bond Strength** 17.390 75.146 24 OK
Sustained Tension Load Bond Strength* N/A N/A N/A N/A
Concrete Breakout Failure** 17.390 53.701 33 OK
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
2
Hilti PROFIS Engineering 3.0.80
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Indonesia.html
Company: Page: 3
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Copy - KSB-PTPTP-P2207109-ENG-001 R2 NM610 Date: 21/10/2022
Fastening point:
Variables
2 2
Ase,N [mm ] futa [N/mm ]
84 500.00
Calculations
Nsa [kN]
42.000
Results
Nsa [kN] f steel f Nsa [kN] Nua [kN]
42.000 0.650 27.300 4.226
Nag = (AA ) y
Na
Na0
ec1,Na y ec2,Na y ed,Na y cp,Na Nba ACI 318-14 Eq. (17.4.5.1b)
f Nag ³ Nua ACI 318-14 Table 17.3.1.1
ANa see ACI 318-14, Section 17.4.5.1, Fig. R 17.4.5.1(b)
2
ANa0 = (2 cNa) ACI 318-14 Eq. (17.4.5.1c)
t uncr
cNa = 10 da √ 1100
ACI 318-14 Eq. (17.4.5.1d)
( )
1
'
y ec,Na = eN £ 1.0 ACI 318-14 Eq. (17.4.5.3)
1+
cNa
Na
ACI 318-14 Eq. (17.4.5.4b)
= MAX(
c ) £
c c a,min Na
y cp,Na , 1.0 ACI 318-14 Eq. (17.4.5.5b)
c ac ac
Nba = l a · t k,c · p · da · hef ACI 318-14 Eq. (17.4.5.2)
Variables
t k,c,uncr [N/mm ]
2
da [mm] hef [mm] ca,min [mm] aoverhead 2
t k,c [N/mm ]
17.56 12.0 110.0 ∞ 1.000 17.56
Calculations
cNa [mm] ANa [mm ]
2
ANa0 [mm ]
2
y ed,Na
181.8 1,057,210 132,151 1.000
Results
Nag [kN] f bond f Nag [kN] Nua [kN]
115.610 0.650 75.146 17.390
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
3
Hilti PROFIS Engineering 3.0.80
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Indonesia.html
Company: Page: 4
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Copy - KSB-PTPTP-P2207109-ENG-001 R2 NM610 Date: 21/10/2022
Fastening point:
Ncbg = (AA ) y
Nc
Nc0
ec,N y ed,N y c,N y cp,N Nb ACI 318-14 Eq. (17.4.2.1b)
f Ncbg ³ Nua ACI 318-14 Table 17.3.1.1
ANc see ACI 318-14, Section 17.4.2.1, Fig. R 17.4.2.1(b)
2
ANc0 = 9 hef ACI 318-14 Eq. (17.4.2.1c)
( )
1
'
y ec,N = 2 eN £ 1.0 ACI 318-14 Eq. (17.4.2.4)
1+
3 hef
ef
ACI 318-14 Eq. (17.4.2.5b)
= MAX(
c ) £
c 1.5h a,min ef
y cp,N , 1.0 ACI 318-14 Eq. (17.4.2.7b)
c ac ac
1.5
Nb = kc l a √ '
fc hef ACI 318-14 Eq. (17.4.2.2a)
Variables
hef [mm] ec1,N [mm] ec2,N [mm] ca,min [mm] y c,N
110.0 145.8 326.5 ∞ 1.000
'
cac [mm] kc la fc [psi]
192.5 24 1.000 3,626
Calculations
ANc [mm ]
2
ANc0 [mm ]
2
y ec1,N y ec2,N y ed,N y cp,N Nb [kN]
871,200 108,900 0.531 0.336 1.000 1.000 57.936
Results
Ncbg [kN] f concrete f Ncbg [kN] Nua [kN]
82.616 0.650 53.701 17.390
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
4
Hilti PROFIS Engineering 3.0.80
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Indonesia.html
Company: Page: 5
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Copy - KSB-PTPTP-P2207109-ENG-001 R2 NM610 Date: 21/10/2022
Fastening point:
4 Shear load
Load Vua [kN] Capacity f Vn [kN] Utilization bV = Vua/f Vn Status
Steel Strength* 2.451 15.300 17 OK
Steel failure (with lever arm)* N/A N/A N/A N/A
Pryout Strength (Concrete Breakout 14.237 123.380 12 OK
Strength controls)**
Concrete edge failure in direction ** N/A N/A N/A N/A
Variables
2 2
Ase,V [mm ] futa [N/mm ]
84 500.00
Calculations
Vsa [kN]
25.500
Results
Vsa [kN] f steel f Vsa [kN] Vua [kN]
25.500 0.600 15.300 2.451
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
5
Hilti PROFIS Engineering 3.0.80
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Indonesia.html
Company: Page: 6
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Copy - KSB-PTPTP-P2207109-ENG-001 R2 NM610 Date: 21/10/2022
Fastening point:
Nc0
ec,N y ed,N y c,N y cp,N Nb ] ACI 318-14 Eq. (17.5.3.1b)
f Vcpg ³ Vua ACI 318-14 Table 17.3.1.1
ANc see ACI 318-14, Section 17.4.2.1, Fig. R 17.4.2.1(b)
2
ANc0 = 9 hef ACI 318-14 Eq. (17.4.2.1c)
( )
1
'
y ec,N = 2 eN £ 1.0 ACI 318-14 Eq. (17.4.2.4)
1+
3 hef
ef
ACI 318-14 Eq. (17.4.2.5b)
= MAX(
c ) £
c 1.5h a,min ef
y cp,N , 1.0 ACI 318-14 Eq. (17.4.2.7b)
c ac ac
1.5
Nb = kc l a √ '
fc hef ACI 318-14 Eq. (17.4.2.2a)
Variables
kcp hef [mm] ec1,N [mm] ec2,N [mm] ca,min [mm]
2 110.0 240.1 188.4 ∞
'
y c,N cac [mm] kc la fc [psi]
1.000 192.5 24 1.000 3,626
Calculations
ANc [mm ]
2
ANc0 [mm ]
2
y ec1,N y ec2,N y ed,N y cp,N Nb [kN]
871,200 108,900 0.407 0.467 1.000 1.000 57.936
Results
Vcpg [kN] f concrete f Vcpg [kN] Vua [kN]
176.257 0.700 123.380 14.237
z z
bNV = bN + bV <= 1
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
6
Hilti PROFIS Engineering 3.0.80
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Indonesia.html
Company: Page: 7
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Copy - KSB-PTPTP-P2207109-ENG-001 R2 NM610 Date: 21/10/2022
Fastening point:
6 Warnings
• The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations (AS 5216:2021, ETAG 001/Annex C,
EOTA TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the
anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering
calculates the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions
explained above. The proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results
must be checked for agreement with the existing conditions and for plausibility!
• Condition A applies where the potential concrete failure surfaces are crossed by supplementary reinforcement proportioned to tie the
potential concrete failure prism into the structural member. Condition B applies where such supplementary reinforcement is not provided, or
where pullout or pryout strength governs.
• Design Strengths of adhesive anchor systems are influenced by the cleaning method. Refer to the INSTRUCTIONS FOR USE given in the
Evaluation Service Report for cleaning and installation instructions.
• For additional information about ACI 318 strength design provisions, please go to
https://submittals.us.hilti.com/PROFISAnchorDesignGuide/
• Installation of Hilti adhesive anchor systems shall be performed by personnel trained to install Hilti adhesive anchors. Reference ACI 318-14,
Section 17.8.1.
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
7
Hilti PROFIS Engineering 3.0.80
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Indonesia.html
Company: Page: 8
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Copy - KSB-PTPTP-P2207109-ENG-001 R2 NM610 Date: 21/10/2022
Fastening point:
7 Installation data
Anchor type and diameter: HIT-RE 500 V3 + HAS-U 5.8
M12
Profile: no profile Item number: 2223823 HAS-U 5.8 M12x160 (element) /
2123403 HIT-RE 500 V3 (adhesive)
Hole diameter in the fixture: df = 14.0 mm Maximum installation torque: 40 Nm
Plate thickness (input): 16.0 mm Hole diameter in the base material: 14.0 mm
Recommended plate thickness: not calculated Hole depth in the base material: 110.0 mm
Drilling method: Hammer drilled Minimum thickness of the base material: 138.0 mm
Cleaning: Compressed air cleaning of the drilled hole according to instructions
for use is required
Hilti HAS-U threaded rod with HIT-RE 500 V3 injection mortar with 110 mm embedment h_ef, M12, Steel galvanized, Hammer drilled
installation per ESR-3814
y
1,350.0 1,350.0
2 6 7 3 50.0
500.0
900.0
x
500.0
1 5 8 4
50.0
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
8
Hilti PROFIS Engineering 3.0.80
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Indonesia.html
Company: Page: 9
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Copy - KSB-PTPTP-P2207109-ENG-001 R2 NM610 Date: 21/10/2022
Fastening point:
8 Alternative fastening
8.1 Alternative fastening data
Anchor plate :
R lx x ly x t = 2,700.0 mm x 1,000.0 mm x 16.0 mm; (Recommended plate thickness: not calculated)
Profile: no profile
Base material: uncracked concrete, , fc' = 3,626 psi; h = 500.0 mm, Temp. short/long: 40/24 °C
Installation: hammer drilled hole, Installation condition: Dry, Installation direction: vertical downward
Reinforcement: tension: condition B, shear: condition B; no supplemental splitting reinforcement present
edge reinforcement: none or < No. 4 bar
Hilti HAS-U threaded rod with HVU2 capsule mortar with 110 mm embedment h_ef, M12, Steel galvanized, Hammer drilled installation per
ESR-4372
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
9
Hilti PROFIS Engineering 3.0.80
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Indonesia.html
Company: Page: 10
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Copy - KSB-PTPTP-P2207109-ENG-001 R2 NM610 Date: 21/10/2022
Fastening point:
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
10