You are on page 1of 10

Hilti PROFIS Engineering 3.0.

80

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Indonesia.html
Company: Page: 1
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Copy - KSB-PTPTP-P2207109-ENG-001 R2 NM610 Date: 21/10/2022
Fastening point:

Specifier's comments:

1 Input data
Anchor type and diameter: HIT-RE 500 V3 + HAS-U 5.8 M12
Item number: 2223823 HAS-U 5.8 M12x160 (element) / 2123403
HIT-RE 500 V3 (adhesive)
Effective embedment depth: hef,act = 110.0 mm (hef,limit = - mm)
Material: 5.8
Evaluation Service Report: ESR-3814
Issued I Valid: 01/03/2021 | 01/01/2023
Proof: Design Method ACI 318-14 / Chem
Stand-off installation: eb = 0.0 mm (no stand-off); t = 16.0 mm

Anchor plate :
R lx x ly x t = 2,700.0 mm x 1,000.0 mm x 16.0 mm; (Recommended plate thickness: not calculated)

Profile: no profile
Base material: uncracked concrete, , fc' = 3,626 psi; h = 500.0 mm, Temp. short/long: 40/24 °C
Installation: hammer drilled hole, Installation condition: Dry
Reinforcement: tension: condition B, shear: condition B; no supplemental splitting reinforcement present
edge reinforcement: none or < No. 4 bar

Application also possible with HVU2 + HAS-U 5.8 M12 under the selected boundary conditions.
More information in section Alternative fastening data of this report.

R
- The anchor calculation is based on a rigid anchor plate assumption.

Geometry [mm] & Loading [kN, kNm]

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

1
Hilti PROFIS Engineering 3.0.80

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Indonesia.html
Company: Page: 2
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Copy - KSB-PTPTP-P2207109-ENG-001 R2 NM610 Date: 21/10/2022
Fastening point:

1.1 Design results


Case Description Forces [kN] / Moments [kNm] Seismic Max. Util. Anchor [%]
1 Combination 1 N = 17.080; Vx = 8.790; Vy = 11.200; no 33
Mx = 5.830; My = 2.940; Mz = 4.340;
Nsus = 0.000; Mx,sus = 0.000; My,sus = 0.000;

2 Load case/Resulting anchor forces

Anchor reactions [kN]


Tension force: (+Tension, -Compression)
2 6 y 7 3
Anchor Tension force Shear force Shear force x Shear force y
1 1.072 1.538 1.343 0.750 Tension
2 4.226 1.137 0.855 0.750 x
3 3.275 2.222 0.855 2.050
4 0.121 2.451 1.343 2.050 1 5 8 4
5 0.755 1.789 1.343 1.183
Compression
6 3.909 1.460 0.855 1.183
7 3.593 1.829 0.855 1.616
8 0.438 2.101 1.343 1.616

max. concrete compressive strain: 0.01 [‰]


max. concrete compressive stress: 0.20 [N/mm ]
2

resulting tension force in (x/y)=(-146.3/326.5): 17.390 [kN]


resulting compression force in (x/y)=(1,278.4/-491.9): 0.312 [kN]

Anchor forces are calculated based on the assumption of a rigid anchor plate.

3 Tension load
Load Nua [kN] Capacity f Nn [kN] Utilization bN = Nua/f Nn Status
Steel Strength* 4.226 27.300 16 OK
Bond Strength** 17.390 75.146 24 OK
Sustained Tension Load Bond Strength* N/A N/A N/A N/A
Concrete Breakout Failure** 17.390 53.701 33 OK

* highest loaded anchor **anchor group (anchors in tension)

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

2
Hilti PROFIS Engineering 3.0.80

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Indonesia.html
Company: Page: 3
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Copy - KSB-PTPTP-P2207109-ENG-001 R2 NM610 Date: 21/10/2022
Fastening point:

3.1 Steel Strength

Nsa = ESR value refer to ICC-ES ESR-3814


f Nsa ³ Nua ACI 318-14 Table 17.3.1.1

Variables
2 2
Ase,N [mm ] futa [N/mm ]
84 500.00

Calculations
Nsa [kN]
42.000

Results
Nsa [kN] f steel f Nsa [kN] Nua [kN]
42.000 0.650 27.300 4.226

3.2 Bond Strength

Nag = (AA ) y
Na

Na0
ec1,Na y ec2,Na y ed,Na y cp,Na Nba ACI 318-14 Eq. (17.4.5.1b)
f Nag ³ Nua ACI 318-14 Table 17.3.1.1
ANa see ACI 318-14, Section 17.4.5.1, Fig. R 17.4.5.1(b)
2
ANa0 = (2 cNa) ACI 318-14 Eq. (17.4.5.1c)
t uncr
cNa = 10 da √ 1100
ACI 318-14 Eq. (17.4.5.1d)

( )
1
'
y ec,Na = eN £ 1.0 ACI 318-14 Eq. (17.4.5.3)
1+
cNa

y ed,Na = 0.7 + 0.3 (cc ) £ 1.0 a,min

Na
ACI 318-14 Eq. (17.4.5.4b)

= MAX(
c ) £
c c a,min Na
y cp,Na , 1.0 ACI 318-14 Eq. (17.4.5.5b)
c ac ac
Nba = l a · t k,c · p · da · hef ACI 318-14 Eq. (17.4.5.2)

Variables
t k,c,uncr [N/mm ]
2
da [mm] hef [mm] ca,min [mm] aoverhead 2
t k,c [N/mm ]
17.56 12.0 110.0 ∞ 1.000 17.56

ec1,N [mm] ec2,N [mm] cac [mm] la


145.8 326.5 192.5 1.000

Calculations
cNa [mm] ANa [mm ]
2
ANa0 [mm ]
2
y ed,Na
181.8 1,057,210 132,151 1.000

y ec1,Na y ec2,Na y cp,Na Nba [kN]


0.555 0.358 1.000 72.814

Results
Nag [kN] f bond f Nag [kN] Nua [kN]
115.610 0.650 75.146 17.390

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

3
Hilti PROFIS Engineering 3.0.80

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Indonesia.html
Company: Page: 4
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Copy - KSB-PTPTP-P2207109-ENG-001 R2 NM610 Date: 21/10/2022
Fastening point:

3.3 Concrete Breakout Failure

Ncbg = (AA ) y
Nc

Nc0
ec,N y ed,N y c,N y cp,N Nb ACI 318-14 Eq. (17.4.2.1b)
f Ncbg ³ Nua ACI 318-14 Table 17.3.1.1
ANc see ACI 318-14, Section 17.4.2.1, Fig. R 17.4.2.1(b)
2
ANc0 = 9 hef ACI 318-14 Eq. (17.4.2.1c)

( )
1
'
y ec,N = 2 eN £ 1.0 ACI 318-14 Eq. (17.4.2.4)
1+
3 hef

y ed,N = 0.7 + 0.3 (1.5h


c
) £ 1.0 a,min

ef
ACI 318-14 Eq. (17.4.2.5b)

= MAX(
c ) £
c 1.5h a,min ef
y cp,N , 1.0 ACI 318-14 Eq. (17.4.2.7b)
c ac ac
1.5
Nb = kc l a √ '
fc hef ACI 318-14 Eq. (17.4.2.2a)

Variables
hef [mm] ec1,N [mm] ec2,N [mm] ca,min [mm] y c,N
110.0 145.8 326.5 ∞ 1.000

'
cac [mm] kc la fc [psi]
192.5 24 1.000 3,626

Calculations
ANc [mm ]
2
ANc0 [mm ]
2
y ec1,N y ec2,N y ed,N y cp,N Nb [kN]
871,200 108,900 0.531 0.336 1.000 1.000 57.936

Results
Ncbg [kN] f concrete f Ncbg [kN] Nua [kN]
82.616 0.650 53.701 17.390

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

4
Hilti PROFIS Engineering 3.0.80

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Indonesia.html
Company: Page: 5
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Copy - KSB-PTPTP-P2207109-ENG-001 R2 NM610 Date: 21/10/2022
Fastening point:

4 Shear load
Load Vua [kN] Capacity f Vn [kN] Utilization bV = Vua/f Vn Status
Steel Strength* 2.451 15.300 17 OK
Steel failure (with lever arm)* N/A N/A N/A N/A
Pryout Strength (Concrete Breakout 14.237 123.380 12 OK
Strength controls)**
Concrete edge failure in direction ** N/A N/A N/A N/A

* highest loaded anchor **anchor group (relevant anchors)

4.1 Steel Strength

Vsa = ESR value refer to ICC-ES ESR-3814


f Vsteel ³ Vua ACI 318-14 Table 17.3.1.1

Variables
2 2
Ase,V [mm ] futa [N/mm ]
84 500.00

Calculations
Vsa [kN]
25.500

Results
Vsa [kN] f steel f Vsa [kN] Vua [kN]
25.500 0.600 15.300 2.451

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

5
Hilti PROFIS Engineering 3.0.80

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Indonesia.html
Company: Page: 6
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Copy - KSB-PTPTP-P2207109-ENG-001 R2 NM610 Date: 21/10/2022
Fastening point:

4.2 Pryout Strength (Concrete Breakout Strength controls)

Vcpg = kcp [(AA ) y Nc

Nc0
ec,N y ed,N y c,N y cp,N Nb ] ACI 318-14 Eq. (17.5.3.1b)
f Vcpg ³ Vua ACI 318-14 Table 17.3.1.1
ANc see ACI 318-14, Section 17.4.2.1, Fig. R 17.4.2.1(b)
2
ANc0 = 9 hef ACI 318-14 Eq. (17.4.2.1c)

( )
1
'
y ec,N = 2 eN £ 1.0 ACI 318-14 Eq. (17.4.2.4)
1+
3 hef

y ed,N = 0.7 + 0.3 (1.5h


c
) £ 1.0 a,min

ef
ACI 318-14 Eq. (17.4.2.5b)

= MAX(
c ) £
c 1.5h a,min ef
y cp,N , 1.0 ACI 318-14 Eq. (17.4.2.7b)
c ac ac
1.5
Nb = kc l a √ '
fc hef ACI 318-14 Eq. (17.4.2.2a)

Variables
kcp hef [mm] ec1,N [mm] ec2,N [mm] ca,min [mm]
2 110.0 240.1 188.4 ∞

'
y c,N cac [mm] kc la fc [psi]
1.000 192.5 24 1.000 3,626

Calculations
ANc [mm ]
2
ANc0 [mm ]
2
y ec1,N y ec2,N y ed,N y cp,N Nb [kN]
871,200 108,900 0.407 0.467 1.000 1.000 57.936

Results
Vcpg [kN] f concrete f Vcpg [kN] Vua [kN]
176.257 0.700 123.380 14.237

5 Combined tension and shear loads


bN bV z Utilization bN,V [%] Status
0.324 0.160 5/3 20 OK

z z
bNV = bN + bV <= 1

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

6
Hilti PROFIS Engineering 3.0.80

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Indonesia.html
Company: Page: 7
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Copy - KSB-PTPTP-P2207109-ENG-001 R2 NM610 Date: 21/10/2022
Fastening point:

6 Warnings
• The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations (AS 5216:2021, ETAG 001/Annex C,
EOTA TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the
anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering
calculates the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions
explained above. The proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results
must be checked for agreement with the existing conditions and for plausibility!
• Condition A applies where the potential concrete failure surfaces are crossed by supplementary reinforcement proportioned to tie the
potential concrete failure prism into the structural member. Condition B applies where such supplementary reinforcement is not provided, or
where pullout or pryout strength governs.
• Design Strengths of adhesive anchor systems are influenced by the cleaning method. Refer to the INSTRUCTIONS FOR USE given in the
Evaluation Service Report for cleaning and installation instructions.
• For additional information about ACI 318 strength design provisions, please go to
https://submittals.us.hilti.com/PROFISAnchorDesignGuide/
• Installation of Hilti adhesive anchor systems shall be performed by personnel trained to install Hilti adhesive anchors. Reference ACI 318-14,
Section 17.8.1.

Fastening meets the design criteria!

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

7
Hilti PROFIS Engineering 3.0.80

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Indonesia.html
Company: Page: 8
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Copy - KSB-PTPTP-P2207109-ENG-001 R2 NM610 Date: 21/10/2022
Fastening point:

7 Installation data
Anchor type and diameter: HIT-RE 500 V3 + HAS-U 5.8
M12
Profile: no profile Item number: 2223823 HAS-U 5.8 M12x160 (element) /
2123403 HIT-RE 500 V3 (adhesive)
Hole diameter in the fixture: df = 14.0 mm Maximum installation torque: 40 Nm
Plate thickness (input): 16.0 mm Hole diameter in the base material: 14.0 mm
Recommended plate thickness: not calculated Hole depth in the base material: 110.0 mm
Drilling method: Hammer drilled Minimum thickness of the base material: 138.0 mm
Cleaning: Compressed air cleaning of the drilled hole according to instructions
for use is required

Hilti HAS-U threaded rod with HIT-RE 500 V3 injection mortar with 110 mm embedment h_ef, M12, Steel galvanized, Hammer drilled
installation per ESR-3814

7.1 Recommended accessories

Drilling Cleaning Setting


• Suitable Rotary Hammer • Compressed air with required • Dispenser including cassette and mixer
• Properly sized drill bit accessories to blow from the bottom of • Torque wrench
the hole
• Proper diameter wire brush

y
1,350.0 1,350.0

2 6 7 3 50.0

500.0
900.0

x
500.0

1 5 8 4
50.0

150.0 799.0 800.0 801.0 150.0

Coordinates Anchor [mm]


Anchor x y c-x c+x c-y c+y Anchor x y c-x c+x c-y c+y
1 -1,200.0 -450.0 - - - - 5 -401.0 -450.0 - - - -
2 -1,200.0 450.0 - - - - 6 -401.0 450.0 - - - -
3 1,200.0 450.0 - - - - 7 399.0 450.0 - - - -
4 1,200.0 -450.0 - - - - 8 399.0 -450.0 - - - -

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

8
Hilti PROFIS Engineering 3.0.80

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Indonesia.html
Company: Page: 9
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Copy - KSB-PTPTP-P2207109-ENG-001 R2 NM610 Date: 21/10/2022
Fastening point:

8 Alternative fastening
8.1 Alternative fastening data

Anchor type and diameter: HVU2 + HAS-U 5.8 M12


Item number: 2223823 HAS-U 5.8 M12x160 (element) / 2164507
HVU2 M12x110 (capsule)
Effective embedment depth: hef,act = 110.0 mm, hnom = 110.0 mm
Material: 5.8
Evaluation Service Report: ESR-4372
Issued I Valid: 01/06/2022 | 01/06/2024
Proof: Design Method ACI 318-14 / Chem
Stand-off installation: eb = 0.0 mm (no stand-off); t = 16.0 mm

Anchor plate :
R lx x ly x t = 2,700.0 mm x 1,000.0 mm x 16.0 mm; (Recommended plate thickness: not calculated)

Profile: no profile
Base material: uncracked concrete, , fc' = 3,626 psi; h = 500.0 mm, Temp. short/long: 40/24 °C
Installation: hammer drilled hole, Installation condition: Dry, Installation direction: vertical downward
Reinforcement: tension: condition B, shear: condition B; no supplemental splitting reinforcement present
edge reinforcement: none or < No. 4 bar

Max. Utilization with HVU2 + HAS-U 5.8 M12: 33 %


Fastening meets the design criteria!

8.2 Installation data

Anchor type and diameter: HVU2 + HAS-U 5.8 M12


Profile: no profile Item number: 2223823 HAS-U 5.8 M12x160 (element) /
2164507 HVU2 M12x110 (capsule)
Hole diameter in the fixture: df = 14.0 mm Maximum installation torque: 40 Nm
Plate thickness (input): 16.0 mm Hole diameter in the base material: 14.0 mm
Recommended plate thickness: not calculated Hole depth in the base material: 110.0 mm
Drilling method: Hammer drilled Minimum thickness of the base material: 140.0 mm
Cleaning: Compressed air cleaning of the drilled hole according to instructions
for use is required

Hilti HAS-U threaded rod with HVU2 capsule mortar with 110 mm embedment h_ef, M12, Steel galvanized, Hammer drilled installation per
ESR-4372

8.2.1 Recommended accessories

Drilling Cleaning Setting


• Suitable Rotary Hammer • Compressed air with required • HVA square drive shafts
• Properly sized drill bit accessories to blow from the bottom of • Torque wrench
the hole
• Proper diameter wire brush

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

9
Hilti PROFIS Engineering 3.0.80

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/Indonesia.html
Company: Page: 10
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Copy - KSB-PTPTP-P2207109-ENG-001 R2 NM610 Date: 21/10/2022
Fastening point:

9 Remarks; Your Cooperation Duties


• Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas
and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be
strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior
to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you
put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by
you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with
regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to
interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability
for a specific application.
• You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for
the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do
not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software
in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or
damaged data or programs, arising from a culpable breach of duty by you.

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

10

You might also like