You are on page 1of 15

Hilti PROFIS Engineering 3.0.

81

www.hilti.com.sg
Company: Page: 1
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Fajar_2 Date: 29/11/2022
Fastening Point:

Specifier's comments:

1 Anchor Design
1.1 Input data

Anchor type and size: HST3 M16 hef2


Return period (service life in years): 50
Item number: 2105858 HST3 M16x135 35/15
Hilti Filling Set or any suitable annular gap filling solution
Effective embedment depth: hef,opti = 85.0 mm (hef,limit = 160.0 mm), hnom = 98.0 mm
Material:
Approval No.: ETA 98/0001
Issued I Valid: 04/05/2021 | -
Proof: Engineering judgement SOFA - based on ETAG testing
Stand-off installation: eb = 0.0 mm (no stand-off); t = 14.0 mm

Baseplate
CBFEM
: lx x ly x t = 370.0 mm x 240.0 mm x 14.0 mm;

Profile: Rectangular hollow, 120 x 80 x 5,0; (L x W x T) = 120.0 mm x 80.0 mm x 5.0 mm


Base material: 2
cracked concrete, , fc,cube = 31.25 N/mm ; h = 250.0 mm
Installation: hammer drilled hole, Installation condition: Dry
Reinforcement: No reinforcement or Reinforcement spacing >= 150 mm (any Ø) or >= 100 mm (Ø <= 10 mm)
with longitudinal edge reinforcement d >= 12.0 [mm]
Reinforcement to control splitting according to ETAG 001, Annex C, 5.2.2.6 present.

CBFEM
- The anchor calculation is based on a component-based Finite Element Method (CBFEM)

Geometry [mm] & Loading [kN, kNm]

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

1
Hilti PROFIS Engineering 3.0.81

www.hilti.com.sg
Company: Page: 2
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Fajar_2 Date: 29/11/2022
Fastening Point:

1.1.1 Load combination


Case Description Forces [kN] / Moments [kNm] Seismic Fire Max. Util. Anchor [%]
1 Combination 1 N = 0.000; Vx = 1.000; Vy = -9.000; no no 276
Mx = 14.000; My = -1.000; Mz = 0.000;

1.2 Load case/Resulting anchor forces

Anchor reactions [kN] y


Tension force: (+Tension, -Compression) 7 3 4 8
Anchor Tension force Shear force Shear force x Shear force y
Tension
1 0.000 1.387 -0.015 -1.386
2 0.000 1.439 0.218 -1.422 x
3 51.038 1.168 0.776 -0.873
4 55.412 1.047 -0.475 -0.934 Compression
5 2.254 1.119 -0.024 -1.119
5 1 2 6
6 1.216 1.230 0.225 -1.209
7 13.393 1.128 0.550 -0.985
8 14.313 1.102 -0.255 -1.072

resulting tension force in (x/y)=(2.3/80.7): 137.626 [kN]


resulting compression force in (x/y)=(-1.8/-8.5): 149.535 [kN]

Anchor forces are calculated based on a component-based Finite Element Method (CBFEM)

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

2
Hilti PROFIS Engineering 3.0.81

www.hilti.com.sg
Company: Page: 3
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Fajar_2 Date: 29/11/2022
Fastening Point:

1.3 Tension load (ETAG, Annex C, Section 5.2.2)

Load [kN] Capacity [kN] Utilization bN [%] Status


Steel failure* 55.412 54.286 103 not recommended
Pull-out failure* 55.412 20.125 276 not recommended
Concrete Breakout failure** 137.626 54.973 251 not recommended
Splitting failure** N/A N/A N/A N/A

* highest loaded anchor **anchor group (anchors in tension)

1.3.1 Steel failure

NRk,s [kN] gM,s NRd,s [kN] NSd [kN]


76.000 1.400 54.286 55.412

1.3.2 Pull-out failure

NRk,p [kN] yc g M,p NRd,p [kN] NSd [kN]


27.000 1.118 1.500 20.125 55.412

1.3.3 Concrete Breakout failure


2 0 2
Ac,N [mm ] Ac,N [mm ] ccr,N [mm] scr,N [mm]
228,225 65,025 127.5 255.0

ec1,N [mm] y ec1,N ec2,N [mm] y ec2,N y s,N y re,N


2.3 0.983 52.4 0.709 1.000 1.000
0
k1 NRk,c [kN] gM,c NRd,c [kN] NSd [kN]
7.700 33.732 1.500 54.973 137.626

Group anchor ID
3-8

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

3
Hilti PROFIS Engineering 3.0.81

www.hilti.com.sg
Company: Page: 4
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Fajar_2 Date: 29/11/2022
Fastening Point:

1.4 Shear load (ETAG, Annex C, Section 5.2.3)

Load [kN] Capacity [kN] Utilization bV [%] Status


Steel failure (without lever arm)* 1.439 44.240 4 OK
Steel failure (with lever arm)* N/A N/A N/A N/A
Pryout failure** 9.055 265.366 4 OK
Concrete edge failure in direction y-** 9.013 35.057 26 OK

* highest loaded anchor **anchor group (relevant anchors)

1.4.1 Steel failure (without lever arm)

VRk,s [kN] gM,s VRd,s [kN] VSd [kN]


55.300 1.250 44.240 1.439

1.4.2 Pryout failure


2 0 2
Ac,N [mm ] Ac,N [mm ] ccr,N [mm] scr,N [mm] k-factor
235,875 65,025 127.5 255.0 3.410

ec1,V [mm] y ec1,N ec2,V [mm] y ec2,N y s,N y re,N


5.5 0.959 0.6 0.995 1.000 1.000
0
NRk,c [kN] gM,c,p VRd,cp [kN] VSd [kN]
33.732 1.500 265.366 9.055

Group anchor ID
1-8

1.4.3 Concrete edge failure in direction y-

lf [mm] dnom [mm] k1 a b


85.0 16.00 1.700 0.075 0.064
2 0 2
c1 [mm] Ac,V [mm ] Ac,V [mm ]
150.0 163,125 101,250

y s,V y h,V y a,V ec,V [mm] y ec,V y re,V


0.967 1.000 1.001 3.8 0.984 1.200
0
VRk,c [kN] gM,c VRd,c [kN] VSd [kN]
28.574 1.500 35.057 9.013

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

4
Hilti PROFIS Engineering 3.0.81

www.hilti.com.sg
Company: Page: 5
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Fajar_2 Date: 29/11/2022
Fastening Point:

1.5 Combined tension and shear loads (ETAG, Annex C, Section 5.2.4)
Steel failure

bN bV aN aV Utilization bN,V [%] Status


2.753 0.257 1.000 0.000 251 not recommended

(bN + bV) / 1.2 £ 1.0

1.6 Warnings
• The anchor design methods in PROFIS Engineering require rigid baseplates as per current regulations (ETAG 001/Annex C, EOTA TR029,
etc.). This means load re-distribution on the anchors due to elastic deformations of the baseplate are not considered - the baseplate is
assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering calculates the
minimum required baseplate thickness with CBFEM to limit the stress of the baseplate based on the assumptions explained above. The
proof if the rigid base plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for
agreement with the existing conditions and for plausibility!
• Checking the transfer of loads into the base material is required in accordance with ETAG 001, Annex C(2010)Section 7! The software
considers that the grout is installed under the baseplate without creating air voids and before application of the loads.
• The design is only valid if the clearance hole in the fixture is not larger than the value given in Table 4.1 of ETAG 001, Annex C! For larger
diameters of the clearance hole see Chapter 1.1. of ETAG 001, Annex C!
• The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to
be followed to ensure a proper installation.
• The design method SOFA assumes that no hole clearance between the anchors and the fixture is present. This can be achieved by filling
the gap with mortar of sufficient compressive strength (e.g. by using the HILTI Filling set) or by other suitable means
• The compliance with current standards (e.g. EN 1993, AS 4100:1998, etc.) is the responsibility of the user
• An SLS-check is not performed for SOFA and has to be provided by the user!
• The anchor design methods in PROFIS Engineering require rigid baseplates, as per current regulations (AS 5216:2021, ETAG 001/Annex
C, EOTA TR029 etc.). This means that the baseplate should be sufficiently rigid to prevent load re-distribution to the anchors due to
elastic/plastic displacements. The user accepts that the baseplate is considered close to rigid by engineering judgment."
• The characteristic bond resistances depend on the return period (service life in years): 50

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

5
Hilti PROFIS Engineering 3.0.81

www.hilti.com.sg
Company: Page: 6
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Fajar_2 Date: 29/11/2022
Fastening Point:

1.7 Installation data


2 2
Baseplate, steel: S 275; E = 210,000.00 N/mm ; fyk = 275.00 N/mm Anchor type and size: HST3 M16 hef2
Profile: Rectangular hollow, 120 x 80 x 5,0; (L x W x T) = 120.0 mm x 80.0 mm Item number: 2105858 HST3 M16x135 35/15
x 5.0 mm
Hole diameter in the fixture: df = 18.0 mm Maximum installation torque: 110 Nm
Plate thickness (input): 14.0 mm Hole diameter in the base material: 16.0 mm
Hole depth in the base material: 118.0 mm
Drilling method: Hammer drilled Minimum thickness of the base material: 140.0 mm
Cleaning: No cleaning of the drilled hole is required

Hilti HST3 stud anchor with 85 mm embedment, M16 hef2, Steel galvanized, installation per ETA 98/0001, with annular gaps filled with Hilti
Filling Set or any suitable gap solutions

1.7.1 Recommended accessories

Drilling Cleaning Setting


• Suitable Rotary Hammer • No accessory required • Hilti SIW 6AT-A22 + SI AT-A22
• Properly sized drill bit • Hilti Filling Set
• Torque wrench
• Hammer

0.0
y
185.0 185.0 35.0

7 3 4 8
120.0
50.0

170.0

x
120.0

5 1 2 6
35.0

35.0 75.0 150.0 75.0 35.0

Coordinates Anchor [mm]


Anchor x y c-x c+x c-y c+y Anchor x y c-x c+x c-y c+y
1 -75.0 -85.0 - 425.0 150.0 - 5 -150.0 -85.0 - 500.0 150.0 -
2 75.0 -85.0 - 275.0 150.0 - 6 150.0 -85.0 - 200.0 150.0 -
3 -75.0 85.0 - 425.0 320.0 - 7 -150.0 85.0 - 500.0 320.0 -
4 75.0 85.0 - 275.0 320.0 - 8 150.0 85.0 - 200.0 320.0 -

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

6
Hilti PROFIS Engineering 3.0.81

www.hilti.com.sg
Company: Page: 7
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Fajar_2 Date: 29/11/2022
Fastening Point:

1.8 Drilling and installation

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

7
Hilti PROFIS Engineering 3.0.81

www.hilti.com.sg
Company: Page: 8
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Fajar_2 Date: 29/11/2022
Fastening Point:

2 Baseplate design

2.1 Input data


Baseplate: Shape: Rectangular
lx x ly x t = 370.0 mm x 240.0 mm x 14.0 mm
Calculation: CBFEM
Material: S 275; Fy = 275.00 N/mm²; εlim = 5.00%
Anchor type and size: HST3 M16 hef2, hef = 85.0 mm
Anchor stiffness: The anchor is modelled considering stiffness values determined from load displacement curves tested in
an independent laboratory. Please note that no simple replacement of the anchor is possible as the anchor
stiffness has a major impact on the load distribution results.
Design method: EN based design using component-based FEM
Stand-off installation: eb = 0.0 mm (No stand-off); t = 14.0 mm
Profile: 120 x 80 x 5,0; (L x W x T x FT) = 120.0 mm x 80.0 mm x 5.0 mm x -
Material: S 275; Fy = 275.00 N/mm²; εlim = 5.00%
Eccentricity x: 0.0 mm
Eccentricity y: 50.0 mm
Base material: Cracked concrete; Custom; fc,cyl = 25.00 N/mm²; h = 250.0 mm; E = 30,000.00 N/mm²; G = 12,000.00
N/mm²; v = 0.20; D = 2,500.00 kg/m³
Welds (profile to baseplate): Type of redistribution: Plastic
Material: S 275
Mesh size: Number of elements on edge: 8
Min. size of element: 10.0 mm
Max size of element: 50.0 mm

2.2 Summary
Description Profile Baseplate Welds [%] Concrete [%]
sEd [N/mm²] ePl [%] sEd [N/mm²] ePl [%] Hole bearing
[%]
1 Combination 1 276.02 0.49 275.39 0.19 1 99 86
2.3 Baseplate plate classification
Results below are displayed for the decisive load combinations: Combination 1
Anchor tension forces Equivalent rigid baseplate (CBFEM) Component-based Finite Element Method
(CBFEM) baseplate
Anchor 1 -0.003 kN 0.000 kN
Anchor 2 -0.003 kN 0.000 kN
Anchor 3 18.831 kN 51.038 kN
Anchor 4 19.157 kN 55.412 kN
Anchor 5 -0.004 kN 2.254 kN
Anchor 6 -0.003 kN 1.216 kN
Anchor 7 18.667 kN 13.393 kN
Anchor 8 19.318 kN 14.313 kN

User accepted to consider the selected baseplate as rigid by his/her engineering judgement. This means the anchor design guidelines can be
applied.

2.4 Profile/Stiffeners/Plate
Profile and stiffeners are verified at the level of the steel to concrete connection. The connection design does not replace the steel design for
critical cross sections, which should be performed outside of PROFIS Engineering.

2.4.1 Equivalent stress and plastic strain


Limit state criteria as per EN1993-1-5 Annex C.8, (1) 2.

Results

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

8
Hilti PROFIS Engineering 3.0.81

www.hilti.com.sg
Company: Page: 9
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Fajar_2 Date: 29/11/2022
Fastening Point:

Part Load Material sEd [N/mm²] ePl [%] fy [N/mm²] gM0 fy/gM0 elim [%] Status
combination [N/mm²]
Plate Combination S 275 275.39 0.19 275.00 1.00 275.00 5.00 OK
1
Profile Combination S 275 275.60 0.29 275.00 1.00 275.00 5.00 OK
1
Profile Combination S 275 276.02 0.49 275.00 1.00 275.00 5.00 OK
1
Profile Combination S 275 275.89 0.43 275.00 1.00 275.00 5.00 OK
1
Profile Combination S 275 275.53 0.25 275.00 1.00 275.00 5.00 OK
1

2.4.1.1 Equivalent stress


Results below are displayed for the decisive load combination: 1 - Combination 1

275.00 N/mm²

0.00 N/mm²

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

9
Hilti PROFIS Engineering 3.0.81

www.hilti.com.sg
Company: Page: 10
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Fajar_2 Date: 29/11/2022
Fastening Point:

2.4.1.2 Plastic strain


Results below are displayed for the decisive load combination: 1 - Combination 1

5.00%

0.00%
2.4.2 Hole bearing
Decisive load combination: 1 - Combination 1
Plate hole bearing resistance, EN1993-1 - 8 section 3.6.1:

Equations

k1 ab fu d t
Fb,Rd =
gM2
VEd
Utilisation =
Fb,Rd

Variables
k1 ab fu [N/mm²] d [mm] t [mm] gM2
Anchor 1 2.50 1.00 430.00 16.0 14.0 1.25
Anchor 2 2.50 1.00 430.00 16.0 14.0 1.25
Anchor 3 2.50 0.87 430.00 16.0 14.0 1.25
Anchor 4 2.50 0.73 430.00 16.0 14.0 1.25
Anchor 5 2.50 1.00 430.00 16.0 14.0 1.25
Anchor 6 2.50 1.00 430.00 16.0 14.0 1.25
Anchor 7 2.50 0.74 430.00 16.0 14.0 1.25
Anchor 8 2.50 0.67 430.00 16.0 14.0 1.25

Results
VEd [kN] Fb,Rd [kN] Utilisation [%] Status
Anchor 1 1.386 192.640 1 OK
Anchor 2 1.439 192.640 1 OK

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

10
Hilti PROFIS Engineering 3.0.81

www.hilti.com.sg
Company: Page: 11
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Fajar_2 Date: 29/11/2022
Fastening Point:

VEd [kN] Fb,Rd [kN] Utilisation [%] Status


Anchor 3 1.168 167.001 1 OK
Anchor 4 1.048 140.060 1 OK
Anchor 5 1.119 192.640 1 OK
Anchor 6 1.230 192.640 1 OK
Anchor 7 1.128 143.029 1 OK
Anchor 8 1.102 128.355 1 OK

2.5 Welds
Profiles are modelled without taking the corner radius into account. Special rules for welding (e.g. for cold-formed profiles ...) are not taken into
account by the software.

2.5.1 Baseplate to profile


Decisive load combination: 1 - Combination 1
Weld design, EN1993-1-8 section 4.5.3.2
Minimum baseplate to profile web thickness (amin): 3.2 mm

Minimum baseplate to profile flange thickness (amin): 3.2 mm

Equations

sw,Ed = (s┴2 + 3 (t┴2 + t||2))0.5


fu
sw,Rd =
bw gM2
fu
s┴,Rd = 0.9
gM2
sw,Ed |s┴|
Utilisation = max ( ; )
sw,Rd s┴,Rd
Variables
Weld bw fu [N/mm²] gM2
Web 0.85 430.00 1.25
Flange 0.85 430.00 1.25

Edge a [mm] L [mm] ePl [%] s┴ [N/mm²] t|| [N/mm²] t┴ [N/mm²]


Member 1-tfl 1 5.0 80.0 1.23 125.08 168.21 139.46
Member 1-bfl 1 5.0 80.0 2.48 -208.98 4.41 197.29
Member 1-w 1 5.0 110.0 0.70 -268.81 66.98 -155.43
Member 1-w 2 5.0 110.0 0.72 183.38 64.06 -193.47

Results
Edge sw,Ed [N/mm²] sw,Rd [N/mm²] s┴,Rd [N/mm²] Utilisation [%] Utilisationc [%] Status
Member 1-tfl 1 398.60 404.71 309.60 99 63 OK
Member 1-bfl 1 400.62 404.71 309.60 99 99 OK
Member 1-w 1 397.74 404.71 309.60 99 83 OK
Member 1-w 2 397.78 404.71 309.60 99 85 OK

2.6 Concrete
Decisive load combination: 1 - Combination 1
According to EN1992-1-1 section 6.7(4), the concrete should have sufficient reinforcement to take into account the tensile forces that develop
due to the fixture attachment. The definition of the reinforcement in the concrete is not within the scope of PROFIS Engineering.

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

11
Hilti PROFIS Engineering 3.0.81

www.hilti.com.sg
Company: Page: 12
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Fajar_2 Date: 29/11/2022
Fastening Point:

2.6.1 Compression in concrete under the baseplate


16.66 N/mm²

0.00 N/mm²

2.6.2 Verification of compression in concrete under the baseplate around the profile as per EN1992-1 section 6.7 and EN1993-1-8,
section 6.2.5

Equations

fjd
bj kj acc fck
=
gc
N
s = Aeff

Utilisation =
s
fjd

Variables
N [kN] Aeff [mm²] bj kj acc fck [N/mm²] gc
149.535 6,139 0.67 3.00 0.85 25.00 1.50

Results
s [N/mm²] fjd [N/mm²] Utilisation [%] Status
24.36 28.48 86 OK

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

12
Hilti PROFIS Engineering 3.0.81

www.hilti.com.sg
Company: Page: 13
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Fajar_2 Date: 29/11/2022
Fastening Point:

2.7 Symbol explanation


a Throat thickness of weld
ab Factor
acc Long-term effects on maximum strength of concrete
Aeff Effective area
amin Minimum weld thickness
bj Joint coefficient βj
bw Corelation factor EN 1993-1-8 tab. 4.1
d Nominal diameter of the bolt
elim Limit plastic strain
ePl Plastic strain from CBFEM results
Fb,Rd Plate bearing resistance EN 1993-1-8 tab. 3.4
fck Characteristic compressive concrete strength
fjd The ultimate bearing strength of the concrete block
fu Ultimate strength
fy Yield strength
gc Service factor - SP 16, Table 41
gM0 Steel safety factor gamma M0
gM2 Steel safety factor gamma M2
k1 Factor for edge distance and bolt spacing perpendicular to the direction of load transfer - EN 1993-1-8 - Table 3.4
kj Concentration factor
L Length of weld
N Resulting compression force
s Average stress in concrete
s┴ Perpendicular stress
s┴,Rd Perpendicular stress resistance
sEd Equivalent stress
sw,Ed Equivalent stress
sw,Rd Equivalent stress resistance
t Thickness of the baseplate
t┴ Shear stress perpendicular to weld axis
t|| Shear stress parallel to weld axis
Utilisationc Weld capacity utilisation
VEd Anchor shear force

2.8 Warnings
● By using the CBFEM calculation functionality of PROFIS Engineering you may act outside the applicable design codes and your specified
baseplate may not behave rigidly. Please, have the results validated by a professional designer and/or structural engineer to ensure
suitability and adequacy for your specific jurisdiction and project requirements.
● The anchor is modelled considering stiffness values determined from load displacement curves tested in an independent laboratory.
Please note that no simple replacement of the anchor is possible as the anchor stiffness has a major impact on the load distribution
results.

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

13
Hilti PROFIS Engineering 3.0.81

www.hilti.com.sg
Company: Page: 14
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Fajar_2 Date: 29/11/2022
Fastening Point:

3 Summary of results
Design of the baseplate, anchor, welds and other elements are based on CBFEM (component based finite element method) and Eurocode
regulations.
Load combination Max. utilisation Status
Anchors Combination 1 276% NOT OK
Baseplate Combination 1 100% OK
Welds Combination 1 99% OK
Concrete Combination 1 86% OK
Profile Combination 1 100% OK

Fastening does not meet the design criteria!

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

14
Hilti PROFIS Engineering 3.0.81

www.hilti.com.sg
Company: Page: 15
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Fajar_2 Date: 29/11/2022
Fastening Point:

4 Remarks; Your Cooperation Duties


● Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles,
formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc.,
that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be
conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based
essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the
relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and
cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility.
The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and
the relevance of the results or suitability for a specific application.
● You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for
the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you
do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the
Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery
of lost or damaged data or programs, arising from a culpable breach of duty by you.

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

15

You might also like