Input data
Anchor type and size R-HPTII-ZF-20160/20
Throughbolt with corrosion-resistant coating
Nominal depth (hnom) 119 mm (hef = 99 mm)
Base material Cracked concrete (C25/30) Temp. short/long None
Reinforcement Spacing ≥150 mm or spacing ≥100 mm with ≤Ø10
A concentrated reinforcement in both directions is present in the region
of the anchorage, which limits the crack width to wk~0.3mm.
Longitudinal edge reinf. Without edge reinforcement or stirrups
Installation Hammer drilling, Installation conditions: Dry concrete
Lever arm None
Fixture Baseplate (x=350 mm, y=360 mm)
Declared thickness: tfix = 12 mm
Recommended thickness: Not checked
Steel profile RECt 150x100x5 (h=150 mm, b=100 mm)
Proof EN 1992-4:2018
RAWLPLUG Technical Data
Working life of 50 years

Design loads

N 500 N
Nsus 0 kN
Mx 12.5 kNm
Mx,sus 0 kNm
My 500 Nm
My,sus 0 kNm
Vx 500 N
Vy -9 kN
Ms 500 Nm
sus - Sustained loads

*Not a real scale

National regulations, environmental and application conditions must be considered when designing the anchorage.
EasyFix4 v. 4.8.2 - Concrete 2128e1c57

Project: Typical Connection R1 Date: 2022-12-23 Page: 2/7


Subject: Organization:
Address: Address:
Calculations made by: Contact:
by Rawlplug

Resulting anchor forces

Anchor N V Vx Vy

1 8.319 kN 3.041 kN 540.7 N -2.992 kN


2 7.893 kN 1.602 kN 540.7 N -1.508 kN
3 18.157 kN 3.006 kN -290.7 N -2.992 kN
4 17.731 kN 1.536 kN -290.7 N -1.508 kN
Max. concrete compressive stress: 2.525 MPa
eNEd - Resulting tension force in (-2 mm, 101 mm): 52.1 kN
eCEd - Resulting compression force in (7 mm, -157 mm): 29.03 kN
N - Tension force
V - Shear force
Vx - Shear force x
Vy - Shear force y

Tensile load (EN 1992-4:2018, Section 7.2.1)

Steel failure
βN1 = 20.2%
calculated for anchor: 3

125.97 kN 1.4 89.98 kN 18.16 kN

Pull-out
βN2 = 65.5%
calculated for anchor: 3

40.37 kN 1.03 1.5 27.72 kN 18.16 kN

National regulations, environmental and application conditions must be considered when designing the anchorage.
EasyFix4 v. 4.8.2 - Concrete 2128e1c57

Project: Typical Connection R1 Date: 2022-12-23 Page: 3/7


Subject: Organization:
Address: Address:
Calculations made by: Contact:
by Rawlplug

Concrete cone failure βN3 = 90.9%

37.92 kN 7.7 25 MPa 99 mm 88209 mm² 239039 mm² 149 mm 297 mm

∞ 1.0 1.0 2 mm 0.986 26 mm 0.849 0.837

1.0 86.06 kN 1.5 57.37 kN 52.1 kN

Splitting failure βN4 = ND

Blow-out failure βN5 = ND

Shear load (EN 1992-4:2018, Section 7.2.2)

Steel failure without lever arm


βV1 = 5.5%
calculated for anchor: 1

1.0 86.94 kN 0.8 69.56 kN 1.25 55.64 kN 3.04 kN

National regulations, environmental and application conditions must be considered when designing the anchorage.
EasyFix4 v. 4.8.2 - Concrete 2128e1c57

Project: Typical Connection R1 Date: 2022-12-23 Page: 4/7


Subject: Organization:
Address: Address:
Calculations made by: Contact:
by Rawlplug

Steel failure with lever arm βV2 = ND

Concrete pry-out failure


βV3 = 8.9%
calculated for anchor: 1

37.92 kN 7.7 25 MPa 99 mm 88209 mm² 59760 mm² 149 mm 297 mm

∞ 1.0 1.0 0 mm 1.0 0 mm 1.0 1.0

2.0 51.39 kN 1.5 34.26 kN 3.04 kN

Concrete edge failure βV4 = ND

Utilisation - Steel failure


calculated for anchor: 3
Tension Shear Combined
βNs βVs α βNsα + βVsα
20.2% 5.5% 2.0 4.4%
correct connection

National regulations, environmental and application conditions must be considered when designing the anchorage.
EasyFix4 v. 4.8.2 - Concrete 2128e1c57

Project: Typical Connection R1 Date: 2022-12-23 Page: 5/7


Subject: Organization:
Address: Address:
Calculations made by: Contact:
by Rawlplug

Utilisation - Concrete failure

Tension Shear Combined


βNc βVc (βNc + βVc)/1.2
90.9% 8.9% 83.1%
correct connection

Hints for the calculations and the program

- According to the current guidelines for the design of anchorages, the calculations in EasyFix4 base on the assumption
that the base plate is rigid, which means that redistribution of loads on the anchors due to elastic deformation of the base
plate is not taken into account. In the software, the recommended thickness of the base plate can be determined, however
the correctness of the installation of the rigid base plate must be checked and confirmed separately.
- The size of the holes in the base plate must not be larger than it is allowed in the table with installation parameters.
Otherwise, all gaps in the holes between the anchors and the fixed element must be filled, e.g. by filling the gaps with
resin of adequate compressive strength.
- Preparation of holes and installation of fasteners must be performed in accordance with the installation instruction,
taking into account the entered input data.
- The information and data contained in EasyFix4 apply only to Rawlplug products. The results of the calculations carried
out with the use of the Software are based on data entered by the User, who is exclusively responsible for the correctness
of the input data and any errors. In addition, the User is exclusively responsible for the verification and recognition of the
calculation results by a competent person, in particular with regard to compliance with applicable standards and
regulations.

Installation data for R-HPTII-ZF-20160/20

Thread diameter d 20 mm


Hole diameter in substrate d0 20 mm
Min. hole depth in substrate h0 124 mm
Nominal depth hnom 119 mm
Calculated min. substrate thickness hmin 250 mm
Installation torque Tinst 180 Nm
Anchor length L 160 mm
Fixture thickness tfix 12 mm
Hole diameter in fixture df 22 mm

National regulations, environmental and application conditions must be considered when designing the anchorage.
EasyFix4 v. 4.8.2 - Concrete 2128e1c57

Project: Typical Connection R1 Date: 2022-12-23 Page: 6/7


Subject: Organization:
Address: Address:
Calculations made by: Contact:
by Rawlplug

National regulations, environmental and application conditions must be considered when designing the anchorage.