Professional Documents
Culture Documents
A.
System
Overview
CT-570CH
CT-550CH
CT-500CH
CT-520CH
Std. Strip
CT-300-1
CT-100A
CT-1525
CT-1570
CT-1551
CT-1015
CT-1014
CT-1550
CT-1701
CT-2500
Accessories
CT-160
CT-460
CT-200
CT-310
CT-720
CT-260
CT-400
PANDUIT Wire Length
Terminal Terminal Range (In.)
Series Description (AWG) [+1/32;-0]
BS 26 – 22 1/4 X X
B3.
Non-insulated
Stainless
butt splices 22 – 18 9/32 X X X X X X X Steel Ties
16 – 14 9/32 X X X X X X X
12 – 10 9/32 X X X X X X X X
BSH Heat shrink splices 22 – 18 5/16 X C1.
Wiring
16 – 14 5/16 X
Duct
12 – 10 5/16 X
BSN Nylon insulated 26 – 22 1/4 X X
butt splices 22 – 18 9/32 X X X X X X X C2.
16 – 14 9/32 X X X X X X X X X Surface
Raceway
12 – 10 9/32 X X X X X X X X
BSV Vinyl insulated 22 – 18 5/16 X X X X X X X X X
butt splices 16 – 14 5/16 X X X X X X X X X X C3.
12 – 10 5/16 X X X X X X X X Abrasion
D, Non-insulated 22 – 18 9/32 X X X X X X X Protection
DR sleeved barrel 16 – 14 9/32 X X X X X X X
disconnects 12 – 10 9/32 X X X X X X X X
(includes right C4.
angle disconnect) Cable
D-M 22 – 18 9/32 X X X X X X X Management
Non-insulated male
blade adapters 16 – 14 9/32 X X X X X X X
D-M Non-insulated 12 – 10 9/32 X X X X X X X
male disconnect D1.
D-MB, 22 – 18 9/32 X X X X Terminals
Non-insulated right
DR-B angle female disc.
and non-insulated
16 – 14 9/32 X X X X
male butted D2.
seam disc. Power
DNF Nylon, funnel entry, 22 – 18 9/32 X X X X X X Connectors
barrel insulated
disconnect 16 – 14 9/32 X X X X X X X X X
(not .110/.111) D3.
DNF-110, Nylon, funnel entry 22 – 18 7/32 X X X X X Grounding
DNF-111 barrel insulated Connectors
disconnect,
16 – 14 9/32 X X X X
.110/.111 tab size
E1.
Labeling
DNF-FI Nylon, fully 22 – 18 9/32 X X X X X X X X X
Systems
insulated 16 – 14 9/32 X X X X X X X X
disconnect 12 – 10 3/8 X X X X X X X X
DPF-FI Premium nylon, 12 – 10 3/8 X X X X X X X X
E2.
fully insulated Labels
disconnect
DNF-FIB, Nylon and premium 22 – 18 9/32 X X X X
DNF-FIM, grade nylon, fully 16 – 14 9/32 X X X X E3.
DNF-FIMB, insulated, funnel Pre-Printed
DPF-FIB, 12 – 10 3/8 X X
entry, male/female & Write-On
DPF-FIMB, couplers Markers
DNF-LPB,
(not .110/.111)
DPF-LPB
E4.
DNF-FIB, Nylon and premium 22 – 18 7/32 X X X X Permanent
DPF-FIB grade nylon, fully Identification
insulated, funnel
entry disconnect, E5.
110/.111 tab size Lockout/
DNF-FIBX Nylon, expanded 22 – 18 X-9/32 X X Tagout
wire entry & Safety
fully insulated 16 – 14 X-9/32 X Solutions
Tooling Selection Guide for PANDUIT Terminals, Splices, and Disconnects (continued)
B1.
Cable Ties Crimp Heads
for Pneumatic
Plier Tools Controlled Cycle Hand Tools CT-600-A Tool Mechanical
Wire
CT-550CH
CT-500CH
CT-570CH
CT-520CH
B2. Std. Strip
CT-300-1
CT-100A
CT-1525
CT-1550
CT-1551
CT-1570
CT-1015
CT-1014
CT-1701
CT-2500
CT-310
CT-460
CT-160
CT-200
CT-400
CT-260
Cable Wire Length
CT-720
PANDUIT
Accessories Terminal Terminal Range (In.)
Series Description (AWG) [+1/32;-0]
DNF-M Nylon insulated, 22 – 18 9/32 X X X X X X X X
B3. funnel entry, 16 – 14 9/32 X X X X X X X X
Stainless barrel insulated,
Steel Ties 12 – 10 9/32 X X X X X X X X
male disconnects
DNFR-B Nylon 22 – 18 9/32 X X
pre-insulated, right 16 – 14 9/32 X X
C1. angle disconnects
Wiring
DNFR-FIB Nylon butted 22 – 18 11/32 X
Duct
seam, right 16 – 14 11/32 X
angle disconnects
C2. DNG-FB SUPRA GRIP ™ nylon, 22 – 18 1/4 X
Surface fully insulated 16 – 14 1/4 X
Raceway disc., (except
DNG14-187FB and
DNG14-188FB)
C3. DNG-FL DISCO-LOK ™ nylon, 22 – 18 1/4 X
Abrasion fully insulated 16 – 14 1/4 X
Protection disconnects
DNH Heat 22 – 18 5/16 X
shrink disconnects 16 – 14 5/16 X
C4. 12 – 10 5/16 X
Cable
Management DV Vinyl barrel insulated 12 – 10 9/32 X X X X X
sleeved disconnects
DV-B Vinyl 22 – 18 1/4 X X X X
D1. insulated, butted
seam disconnects 16 – 14 1/4 X X X X
Terminals
DV-M Vinyl barrel insulated 22 – 18 9/32 X X X X X X X X X
male blade adapters 16 – 14 9/32 X X X X X X X X X X
D2. DV-M Vinyl insulated 12 – 10 9/32 X X X
Power male disconnects
Connectors DV-MB Vinyl insulated 22 – 18 9/32 X X X X X X
butted seam male
disconnects 16 – 14 9/32 X X X X X X X
D3.
Grounding DV-P Vinyl insulated 22 – 18 1/4 X X X X X X X X
Connectors piggyback
disconnects 16 – 14 1/4 X X X X X X X X
D1.90 Order number of pieces required, in multiples of Standard Package Quantity. Prime items appear in BOLD.
ELECTRICAL SOLUTIONS
A.
System
Overview
Tooling Selection Guide for PANDUIT Terminals, Splices, and Disconnects (continued)
B1.
Cable Ties
Crimp Heads
for Pneumatic
Plier Tools Controlled Cycle Hand Tools CT-600-A Tool Mechanical
Wire B2.
CT-500CH
CT-570CH
CT-520CH
CT-550CH
Std. Strip Cable
CT-300-1
CT-100A
CT-1701
CT-1550
CT-1551
CT-2500
CT-1014
CT-1570
CT-1015
CT-1525
CT-720
CT-400
CT-310
CT-200
CT-460
CT-160
CT-260
PANDUIT Wire Length Accessories
Terminal Range (In.)
Series Terminal Description (AWG) [+1/32;-0]
P-R, Non-insulated rings, 26 – 22 3/16 X X X B3.
P-F, forks, locking forks, 22 – 18 7/32 X X X X X X X Stainless
P-LF, short locking forks, Steel Ties
P-SLF, 16 – 14 7/32 X X X X X X X
flanged forks
P-FF 12 – 10 9/32 X X X X X X X X
C1.
P-RHT6 High temperature rings 22 – 18 9/32 X X X X X X X
Wiring
16 – 14 9/32 X X X X X X X Duct
12 – 10 9/32 X X X X X X X X
PH Heat shrink terminals 22 – 18 5/16 X
16 – 14 5/16 X C2.
Surface
12 – 10 5/16 X
Raceway
PN-R, Nylon and nylon 26 – 22 3/16 X X X
PN-RX, funnel entry forks, 22 – 18 7/32 X X X X X X X
PN-F, locking forks, flanged 16
PN-LF, – 14 7/32 X X X X X X X X C3.
forks (includes Abrasion
PN-FF, 12 – 10 9/32 X X X X X X
expanded insulation) Protection
PNF-R,
PNF-F,
PNF-LF
C4.
PN-HDR, Nylon insulated heavy 16 – 12 9/32 X X X X X
Cable
PN-HDRX duty and nylon Management
expanded insulated
heavy duty rings
PN-SLF, Nylon insulated short 22 – 18 7/32 X X X X X X
D1.
PNF-SLF locking forks 16 – 14 7/32 X X X X X X X Terminals
12 – 10 9/32 X X X X X
PS Non-insulated 22 – 18 5/16 X X X
parallel splices 20 – 16 5/16 X X X D2.
14 – 12 7/16 X X X Power
PSN Nylon insulated 22 – 18 5/16 X X X Connectors
parallel splices 20 – 16 5/16 X X X X X X
14 – 12 7/16 X X X
D3.
PK-R KYNAR ■ rings 22 – 18 7/32 X X X X X X X X Grounding
16 – 14 7/32 X X X X X X X X Connectors
12 – 10 9/32 X X X X X
PV-HDR, Vinyl insulated heavy 16 – 12 5/16 X X X X X
PV-HDRX duty rings E1.
PV-LF, Vinyl insulated locking 22 – 18 5/16 X X X X X X X X Labeling
PV-LFX Systems
forks (includes 16 – 14 5/16 X X X X X X X X
expanded insulation) 12 – 10 5/16 X X X X X X X
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory) D1.91
ELECTRICAL SOLUTIONS
A.
System
Overview
E2.
Labels
E3.
Pre-Printed
& Write-On
Markers
E4.
Permanent
Identification
E5.
Lockout/
Tagout
& Safety
Solutions
F.
Index
D1.92 Order number of pieces required, in multiples of Standard Package Quantity. Prime items appear in BOLD.
ELECTRICAL SOLUTIONS
A.
System
Overview
Wire
PANDUIT Range Wire Range Wire Strip
Ferrule Series Ferrule Description (AWG) (mm²) Length CT-1000 CT-1002 CT-1003 CT-1004 CT-1005 CT-1006 CT-1104 CT-1123 B2.
F Non-insulated ferrules 24 .25 X X
Cable
Accessories
22 – 18 .50 – 1.00 X X X
16 1.50 X X X
14 2.50 X X B3.
12 4.00 X X X Stainless
10 6.00 X X X
Steel Ties
8 10.0 X X X
6 16.0 X X X C1.
4–2 25.0 – 35.0 Please X X Wiring
1 50.0 See X Duct
Ferrule
FSD, FSF Insulated single wire 26 – 18 .41 – 1.00 Tables – X X X
ferrules (DIN or French 16 – 14 1.50 – 2.00 Pgs. X X X
color code) C2.
12 – 10 4.00 – 6.00 D1.73 – X X X Surface
D1.77
8 10.0 X X X X Raceway
6 16.0 X X X
4–2 25.0 – 35.0 X
C3.
1 50.0 X Abrasion
FTD Insulated twin 22 – 18 .50 – 1.00 X X X Protection
wire ferrules 16 – 14 1.50 – 2.00 X X X
12 4.00 X X X
C4.
10 6.00 X X X
Cable
FSD-DSL Insulated single wire 20 – 14 .50 – 2.50 .31" (8mm) X Management
FS-DSL ferrules on strips of
50 (DIN or other
color code)
D1.
Terminals
D2.
Power
Connectors
D3.
Grounding
Connectors
E1.
Labeling
Systems
E2.
Labels
E3.
Pre-Printed
& Write-On
Markers
E4.
Permanent
Identification
E5.
Lockout/
Tagout
& Safety
Solutions
F.
Index