You are on page 1of 1

Certificate of Calibration

AlTakamul Yard, North Rumaila-South Iraq


●Phone : +964 7810009138 ● www.qualitycontrol-iraq.com ● E-mail: op@qualitycontrol-iraq.com

Date of Issue: November 7, 2022 Page 1 of 1


REQUEST NUMBER By Mail APPROVED BY LAB INCHARGE-QC
JOB NUMBER QC/JN/22/00318
CERTIFICATE NUMBER Q
: C221107-01 ABDULRAHMAN LOAY

CUSTOMER DETAILS
Name : Zhongman Petroleum Engineering Technology Service (Hong Kong )Co. Limited Iraq Branch
Address : Basra , South Iraq
Rig Number : ZPEC-016
EQUIPMENT IDENTIFICATION AND SPECIFICATIONS

Description Portable H2S Gas Detector Alarm Details Low High


Manufacturer HONEYWELL BW H2S-ppm 10 15
Model BW SOLO
Serial Number 9256BWS0A214501000
Type Digital
Calibrated Range 25 PPM H2S
Calibrated By : bdulrahman Loay
A
Calibration Date :November 7, 2022
Calibration Due May 6, 2023 6 Months Validity from the date of Calibration
Calibration Site : LAB
QC

ENVIRONMENTAL CONDITIONS DURING TEST

Ambient Temperature : 24 °C ± 0.1 °C


Relative Humidity 39 %RH ± 0.5 %RH

CALIBRATION METHOD

A reference cylinder consisting of H2S Gas (H2S) is used , which are detected by gas detector by diffusion.

TRACEABILITY
The measurements made by QC Calibration & Testing Labs are traceable to NIST, vide Intermountain Speciality Gases Certificate of Analysis
The measurements made by QC Calibration & Testing Labs, realize the physical units of measurements (SI), through its state of
the art calibration standards that are controlled and maintained by QC.

REFERENCE EQUIPMENT USED :


DESCRIPTION SERIAL NO. MAKE GAS EXPIRY DATE
Hydrogen Sulphide Gas-25 PPM 955-506854 CALGAZ 7/27/2024

CALIBRATION TEST RESULTS

Gas Name Values of UUC Values on Reference Standard Error in Reading of UUC Uncertainty of Measurement

Hydrogen Sulphide(H2S) ppm 25 25 0.0 ± 1