LB-CAL-050

Emirates International Accreditation Centre

has accredited

ACCUVER CALIBRATION LABORATORY

Warehouse # C 45 |Industrial Area 1 Qusais

Dubai | United Arab Emirates

In accordance with the requirements of

ISO/IEC 17025:2017

General requirements for the competence of testing and calibration laboratories

to undertake the calibration in the attached accreditation scope

This Accreditation is invalid without the attached accreditation scope and shall remain in force within the validity

period printed below, subject to continuing compliance with the requirements of the accreditation criteria.

Validity: 19-10-2023 to 17-06-2026

Initial Accreditation Date: 18-06-2017

Amina Ahmed Mohammed


Accreditation Scope
LB-CAL-050

Accuver Calibration laboratory


Warehouse # C 45, Industrial Area 1 Qusais
Dubai-United Arab Emirates
Date: 19-10-2023 Valid to: 17-06-2026

Accreditation History

Scope Issue No. Details Date

Pressure 05 Renewal accreditation and Extension in Scope 19-10-2023


(Temperature & Humidity, Torque,Volume, Time &
Temperature & Humidity 04
Frequency , Pressure, Balance, Electrical & Dimension )
Dimensional 03

Time & Frequency 04

Mass 04

Balance 03

Elactrical 04

Volume 01

Torque 01

Pressure 04 Certificate validity was extended for 6 months from 18-06- 18-06-2023
2023 up to 17-12-2023
Temperature & Humidity 03

Dimensional 02

Time & Frequency 03

Mass 03

Balance 2

Elactrical 03

Temperature & Humidity 02 Missed parameters from last scope update 20-12-2021

Time & Frequency 02 Modification in CMC Values (CMC increased of Tachometer


and Centrifuge/ Variable Rotation Speed)
Electrical 02 Calibration field name & modification in CMC (increased for
Defibrillator / Defibrillator Analyzer))
Mass 02 Calibration field Name & Calibration method (typo error
from last scope update)
Pressure 03 Re-issued to comply with the new accreditation number 10-05-2021
format

info@eiac.gov.ae One Central-Offices 2- Level 3, Suit No.: 302, 303 308. Office: +971 4 872 2666
www.eiac.gov.ae The Trade Centre District, Dubai-United Arab Emirates 1 of 38
Accreditation Scope
10-05-2021
LB-CAL-050
Temperature & Humidity 01 Granted accreditation from Emirates International
Accreditation Centre EIAC
Dimensional 01

Time & Frequency 01

Mass 01

Balance 01

Elactrical 01

Pressure 02 Renewal accreditation and first issuance under the name of 14-07-2020
EIAC
Pressure 01 Granted accreditation from Dubai Accreditation Center 18-06-2017
'DAC'

info@eiac.gov.ae One Central-Offices 2- Level 3, Suit No.: 302, 303 308. Office: +971 4 872 2666
www.eiac.gov.ae The Trade Centre District, Dubai-United Arab Emirates 2 of 38
Accreditation Scope
Pressure Calibration
LB-CAL-050

Accuver Calibration laboratory

Warehouse # C 45, Industrial Area 1 Qusais


Dubai-United Arab Emirates
Issue no.: 05 Date: 19-10-2023 Valid to: 17-06-2026

Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
pneumatic Pressure DMS 2016 based on BS -87 kPa to 0 Mpa 1 kPa Laboratory/
(gauge) (Digital and EN 837-1:1998 Customer
Analogue) Premises

pneumatic Pressure DMS 2016 based on BS 0 MPa to 3 MPa 1 kPa Laboratory/


(gauge) (Digital and EN 837-1:1998 Customer
Analogue) Premises

Pneumatic Pressure Based on DKD-R - 6-1 -87 kPa to 0 MPa 1 kPa Laboratory/
indicators/Transmitters ,2014 and EURAMET CG Customer
(Digital and Analogue) 17 Premises

Pneumatic Pressure Based on DKD-R - 6-1 0 to 4 MPa 4 kPa Laboratory/


indicators /Transmitters ,2014 and EURAMET CG Customer
(Digital and Analogue) 17 Premises

Hydraulic Pressure DMS 2016 based on BS 0 MPa to 100 MPa 0.02 MPa + 2.0x 10-4 pe Laboratory/
(gauges) (Digital and EN 837-1:1998 Customer
Analogue) Premises

Manometer Based on DKD-R - 6-1 0 to 70 kPa 5.6 kPa Laboratory/


,2014 and EURAMET CG Customer
17 Premises

(0 to 10 psi) (0.8 psi) Laboratory/


Customer
Premises

One Central-Offices 2- Level 3, Suit No.: 302, 303 308.


info@eiac.gov.ae Office: +971 4 872 2666
www.eiac.gov.ae The Trade Centre District, Dubai-United Arab Emirates 3 of 38
Accreditation Scope
Pressure Calibration
LB-CAL-050

Accuver Calibration laboratory

Warehouse # C 45, Industrial Area 1 Qusais


Dubai-United Arab Emirates
Issue no.: 05 Date: 19-10-2023 Valid to: 17-06-2026

Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Differential Pressure Based on DKD-R - 6-1 0 to 175 kPa 0.5 kPa Laboratory/
Gauge ,2014 and EURAMET CG Customer
17 Premises

Hydraulic/Pneumatic OIML R 109:1993/OIML 0 to 140 MPa 0.6 MPa Laboratory/


Pressure Chart Recorder R 101:1991 Customer
Premises

NIBP- OIML R 16-1:2002 0 to 20 kPa 0.05 kPa Laboratory/


Sphygmomanometer Customer
(Analogue/Digital) Premises

(0 to 150 mmHg) (0.4 mmHg)

20 to 40 kPa 1 kPa Laboratory/


Customer
Premises

(150 to 300 mmHg) (7.5 mmHg)

One Central-Offices 2- Level 3, Suit No.: 302, 303 308.


info@eiac.gov.ae Office: +971 4 872 2666
www.eiac.gov.ae The Trade Centre District, Dubai-United Arab Emirates 4 of 38
Accreditation Scope
Temperature Humidity Calibration
LB-CAL-050

Accuver Calibration laboratory

Warehouse # C 45, Industrial Area 1 Qusais


Dubai-United Arab Emirates
Issue no.: 04 Date: 19-10-2023 Valid to: 17-06-2026

Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Liquid in Glass (CP/06/T-04) based on -30°C to 0°C 0.9 °C Laboratory
Thermometer BIS IS 6274
0°C to 300°C 1.7 °C

Thermocouple (CP/06/T-02) based on -80°C to 300°C 0.28 °C Laboratory/


Euramet cg-8 Customer
300°C to 600°C 3.7 °C
Premises
600°C to 1200°C 4.3 °C

RTD (CP/06/T-01) based on -80°C to 50°C 0.14 °C


DKD R5-1
50°C to 300°C 0.28 °C

300°C to 650°C 0.5 °C

Hygrometer/ Humidity/ (CP/06/T-10) based on 10°C to 60°C 0.28 °C


Temperature Humity Euramet cg-20
60 %RH to 90 %RH 1.6 %RH
meter
Non contact (CP/06/T-09) based on -15°C to 149°C 1.8°C
thermometer (Ear MSL Guide 22
149°C to 600°C 2.7°C
thermometer,thermal
imager,pyrometer)

One Central-Offices 2- Level 3, Suit No.: 302, 303 308.


info@eiac.gov.ae Office: +971 4 872 2666
www.eiac.gov.ae The Trade Centre District, Dubai-United Arab Emirates 5 of 38
Accreditation Scope
Temperature Humidity Calibration
LB-CAL-050

Accuver Calibration laboratory

Warehouse # C 45, Industrial Area 1 Qusais


Dubai-United Arab Emirates
Issue no.: 04 Date: 19-10-2023 Valid to: 17-06-2026

Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Liquid in
Drying GlassIncubator,
Oven, (CP/06/T-04) based on -80°C to 0°C
(CP/06/T-08) 0.34 °C Laboratory
Laboratory/
Thermometer
Chiller/ Freezer/ BIS ISR.5-7
DKD 6274 Customer
0°C to 250°C 0.89 °C
Refrigerator, Autoclave, Premises
Furnace, Hot Cabinet,
Environmental
Direct Reading Chamber (CP/06/T-03) based on -80°C to 300°C 0.22 °C Laboratory/
Thermometer DKD R5-1 Customer
Premises
Digital/ Dial (CP/06/T-03) based on -50°C to 200°C 0.9 °C Laboratory/
Thermometer EN 13190 Customer
200°C to 600°C 0.9 °C
Premises
600°C to 1200°C 4.0 °C

Temperature Datalogger (CP/06/T-10) based on -25°C to 70°C 0.50°C Laboratory/


Euramet cg-20 Customer
Premises

Dry Block Calibrator (CP/06/T-05) based on -50°C to 200°C 0.17°C Laboratory/


Euramet cg-13 Customer
200°C to 600°C 0.24°C
Premises
600°C to 1200°C 4.5 °C

Water Bath/ Oil Bath (CP/06/T-06) based on 30°C to 100°C 0.17°C Laboratory/
Euramet cg-13. Customer
100°C to 300°C 0.24°C
Premises

One Central-Offices 2- Level 3, Suit No.: 302, 303 308.


info@eiac.gov.ae Office: +971 4 872 2666
www.eiac.gov.ae The Trade Centre District, Dubai-United Arab Emirates 6 of 38
Accreditation Scope
Temperature Humidity Calibration
LB-CAL-050

Accuver Calibration laboratory

Warehouse # C 45, Industrial Area 1 Qusais


Dubai-United Arab Emirates
Issue no.: 04 Date: 19-10-2023 Valid to: 17-06-2026

Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Liquid in Glass /
HYGROMETER (CP/06/T-04) based on 30 to 60 % RH
(CP/06/T-10) 1.8 % RH Laboratory
LABORATORY
Thermometer
HUMIDITY / BIS IS 6274
Euramet cg-20
Temperature Humidity
Measuring Location in Comparison method (CP- -80 to 200 °C 0.7°C LABORATORY
Chiller, Freezer, 06/T-16) based on / CUSTOMER
Incubator, Oven, co2 (DKD R5-7 (Method C)). PREMISES
incubator, Dish washers,
Measuring location in Comparison method (CP- 250 to 500 °C 3.7 °C LABORATORY
Furnaces 06/T-14) based on / CUSTOMER
500 to 1500 °C 5.0 °C
(DKD R5-7 (Method C)). PREMISES

Measuring Location in Comparison method (CP-20 %RH to 60 %RH 2.4 %RH LABORATORY
Humidity Chambers 06/T-15) based on / CUSTOMER
60 %RH to 90 %RH 2.7 % RH
(DKD R5-7 (Method C)). PREMISES

One Central-Offices 2- Level 3, Suit No.: 302, 303 308.


info@eiac.gov.ae Office: +971 4 872 2666
www.eiac.gov.ae The Trade Centre District, Dubai-United Arab Emirates 7 of 38
Accreditation Scope
Temperature Humidity Calibration
LB-CAL-050

Accuver Calibration laboratory

Warehouse # C 45, Industrial Area 1 Qusais


Dubai-United Arab Emirates
Issue no.: 04 Date: 19-10-2023 Valid to: 17-06-2026

Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Liquid in Glass (CP/06/T-04) based on Laboratory
Thermometer BIS IS 6274

One Central-Offices 2- Level 3, Suit No.: 302, 303 308.


info@eiac.gov.ae Office: +971 4 872 2666
www.eiac.gov.ae The Trade Centre District, Dubai-United Arab Emirates 8 of 38
Accreditation Scope
Dimensional Calibration
LB-CAL-050

Accuver Calibration laboratory

Warehouse # C 45, Industrial Area 1 Qusais


Dubai-United Arab Emirates
Issue no.: 03 Date: 19-10-2023 Valid to: 17-06-2026

Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Caliper (Vernier/ Dial/ CP/03/DIM-01 0-600 mm 21 µm Laboratory
Digital) Based on IS 3651- 1&2

External Micrometer CP/03/DIM-02 0-25 mm 2.6 µm Laboratory


(Digital/ Analogue) Based on IS 2967

Height Gauge CP/03/DIM-03 0 - 600 mm 31 µm Laboratory


(Vernier/Dial/Digital) Based On IS 2921

Measuring Scale (Steel CP/03/DIM-20 0-1000 mm 0.13 mm Laboratory


rule) Based On IS 1269 -1

Feeler Gauge CP/ 03/DIM-13 0.05 mm to 1 mm 2.9 µm Laboratory


Based On IS 3179

Dial Indicator CP/03/DIM-07,08 0-25 mm 3.0 µm Laboratory


Based On IS 11498

Micrometer Setting Rod CP/03/DIM-16 0-100 mm 3.7 µm Laboratory

One Central-Offices 2- Level 3, Suit No.: 302, 303 308.


info@eiac.gov.ae Office: +971 4 872 2666
www.eiac.gov.ae The Trade Centre District, Dubai-United Arab Emirates 9 of 38
Accreditation Scope
Dimensional Calibration
LB-CAL-050

Accuver Calibration laboratory

Warehouse # C 45, Industrial Area 1 Qusais


Dubai-United Arab Emirates
Issue no.: 03 Date: 19-10-2023 Valid to: 17-06-2026

Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Caliper Based on IS 3651 -1 &2 > 600 mm - 1000 mm 35 µm Laboratory
(Vernier/Dial/Digital) CP/03/DIM-01 Based
on IS 3651 -1 &2

External Micrometer CP/03/DIM-02 >25 mm -100 mm 3.5 µm Laboratory


(Digital / Analogue) Based on ISO 3611

Coating Thickness Gauge CP/03/DIM-21 Up to 1600 µm 2.3 µm Laboratory


Based on IS 6012

Ultrasonic thickness CP/03/DIM-22 0.5 to 100 mm 32 µm Laboratory


Gauge Based on ASTM –E –
797-95

One Central-Offices 2- Level 3, Suit No.: 302, 303 308.


info@eiac.gov.ae Office: +971 4 872 2666
www.eiac.gov.ae The Trade Centre District, Dubai-United Arab Emirates 10 of 38
Accreditation Scope
Time Frequency Calibration
LB-CAL-050

Accuver Calibration laboratory

Warehouse # C 45, Industrial Area 1 Qusais


Dubai-United Arab Emirates
Issue no.: 04 Date: 19-10-2023 Valid to: 17-06-2026

Calibration Measurement
Calibration Field/
Calibration Method Range and Specification Capability Location
Measuring Quality
(CMC)*

Oscilloscope & Time Direct Method Using > 10 ns to 100 ns 0.6 ns Laboratory/
Base Waveform Generator Customer
> 100 ns to 1 us 5.8 ns
Premises
> 1 us to 10 us 0.058 μs

> 10 us to 100 us 0.58 μs

> 100 us to 1 ms 5.8 μs

> 1 ms to 10 ms 58 μs

> 10 ms to 100 ms 0.58 ms

> 100 ms to 1 s 58 ms

Oscilloscope & Direct Method Using upto 1 V 2.6 mV Laboratory/


Amplitude Waveform Generator Customer
> 1 V to 2 V 26 mV
Premises
> 2 V to 5 V 0.06 V

> 5 V to 7 V 0.08 V

> 7 V to 10 V 0.12 V

One Central-Offices 2- Level 3, Suit No.: 302, 303 308.


info@eiac.gov.ae Office: +971 4 872 2666
www.eiac.gov.ae The Trade Centre District, Dubai-United Arab Emirates 11 of 38
Accreditation Scope
Time Frequency Calibration
LB-CAL-050

Accuver Calibration laboratory

Warehouse # C 45, Industrial Area 1 Qusais


Dubai-United Arab Emirates
Issue no.: 04 Date: 19-10-2023 Valid to: 17-06-2026

Calibration Measurement
Calibration Field/
Calibration Method Range and Specification Capability Location
Measuring Quality
(CMC)*

Oscilloscope & Time Direct Method Using > 1 Hz to 10 Hz 58 mHz Laboratory/


Base
Frequency Waveform Generator Customer
> 10 Hz to 100 Hz 0.6 Hz
Premises
> 100 Hz to 1 kHz 5.8 Hz

> 1 kHz to 10kHz 58 Hz

> 10kHz to 100kHz 0.06 kHz

> 100 kHz to 1 MHz 5.8 kHz

> 1 MHz to 5 MHz 5.8 kHz

> 5 MHz to 10 MHz 5.8 kHz

> 10 MHz to 25MHz 5.8 kHz

> 25 MHz to 50 MHz 5.8 kHz

> 50 MHz to 100 MHz 76 kHz

Tachometer Direct Method using non 60 to 600 rpm 0.2 rpm Laboratory/
Contact tachometer Customer
601 rpm to 6000 rpm 1.2 rpm
adpater & Multiproduct Premises
Calibrator 6001 rpm to 12000 rpm 1.8 rpm

12001 rpm to 60000 2.2 rpm


rpm
60001 rpm to 99000 3.5 rpm
rpm

One Central-Offices 2- Level 3, Suit No.: 302, 303 308.


info@eiac.gov.ae Office: +971 4 872 2666
www.eiac.gov.ae The Trade Centre District, Dubai-United Arab Emirates 12 of 38
Accreditation Scope
Time Frequency Calibration
LB-CAL-050

Accuver Calibration laboratory

Warehouse # C 45, Industrial Area 1 Qusais


Dubai-United Arab Emirates
Issue no.: 04 Date: 19-10-2023 Valid to: 17-06-2026

Calibration Measurement
Calibration Field/
Calibration Method Range and Specification Capability Location
Measuring Quality
(CMC)*

Oscilloscope
Centrifuge & Time
/ Variable Direct MethodMethod
Comparasion Using 1 rpm 60 rpm 0.2 rpm Laboratory/
Base
Rotation Speed Waveform
using Generator
non Contact Customer
61 rpm to 120 rpm 1.4 rpm
tachometer Premises
121 to 600 rpm 1.6 rpm

601 to 1200 rpm 2.3 rpm

1201 rpm to 6000 rpm 4.8 rpm

6001 rpm to 12000 rpm 8.2 rpm

12001 rpm to 25000 16 rpm


rpm
Stop Watch/ Timer Inlab Method CP/05/EL- > 0 s to 10 min 1.0 s Laboratory/
10 complying to > 10 min to 1 hr 1.3 s Customer
NIST960-12 Premises
> 1 hr to 10 hr 4.2 s

> 10 hr to 15 hr 4.8 s

> 15 hr to 24 hr 35 s
> 24 hr to < 100 hr 40 s
OSCILLOSCOPE & Direct Method Using upto 50 MHz 7.1 kHz LABORATORY
BANDWIDTH (F) Waveform Generator / Customer
>50 MHz upto 100 MHz 7.1 kHz
Premises

>100 MHzupto 160 8.1 kHz


MHz
STOP WATCH / TIMER Comparison Method > 10 s to 1 hr 0.61 s Laboratory
(CP/05/EL-20) with
Time Interval Meter

One Central-Offices 2- Level 3, Suit No.: 302, 303 308.


info@eiac.gov.ae Office: +971 4 872 2666
www.eiac.gov.ae The Trade Centre District, Dubai-United Arab Emirates 13 of 38
Accreditation Scope
Mass Calibration
LB-CAL-050

Accuver Calibration laboratory

Warehouse # C 45, Industrial Area 1 Qusais


Dubai-United Arab Emirates
Issue no.: 04 Date: 19-10-2023 Valid to: 17-06-2026

Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Mass OIML R111-1.2004 0.001g 0.041 mg Laboratory

0.002g 0.041 mg

0.005g 0.042 mg

0.01g 0.042 mg

0.02g 0.042 mg

0.05g 0.042 mg

0.1g 0.043 mg

0.2g 0.045 mg

0.5g 0.040 mg

1g 0.050 mg

2g 0.061 mg

5g 0.065 mg

10g 0.085 mg

20g 0.09 mg

One Central-Offices 2- Level 3, Suit No.: 302, 303 308.


info@eiac.gov.ae Office: +971 4 872 2666
www.eiac.gov.ae The Trade Centre District, Dubai-United Arab Emirates 14 of 38
Accreditation Scope
Mass Calibration
LB-CAL-050

Accuver Calibration laboratory

Warehouse # C 45, Industrial Area 1 Qusais


Dubai-United Arab Emirates
Issue no.: 04 Date: 19-10-2023 Valid to: 17-06-2026

Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Mass OIML R111-1.2004 50g 0.12 mg Laboratory

100g 0.23 mg

200g 0.63 mg

500g 1.1 mg

1kg 2.1 mg

2Kg 3.2 mg

5kg 4.3 mg

10kg 5.4 mg

20kg 11 mg

One Central-Offices 2- Level 3, Suit No.: 302, 303 308.


info@eiac.gov.ae Office: +971 4 872 2666
www.eiac.gov.ae The Trade Centre District, Dubai-United Arab Emirates 15 of 38
Accreditation Scope
Balance Calibration
LB-CAL-050

Accuver Calibration laboratory

Warehouse # C 45, Industrial Area 1 Qusais


Dubai-United Arab Emirates
Issue no.: 03 Date: 19-10-2023 Valid to: 17-06-2026

Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Weighing Balance EUROMET CG 18 V4 1mg to 20g 0.44 mg Customer
Premises
> 20 g to 200g 0.75 mg

> 200 g to 500g 1.6 mg

> 500 g to 1000g 2.3 mg

> 1 kg to 10 kg 11 mg

>10 kg to 60kg 5.3 g

> 60 kg to 300kg 8.3 g

300 kg to 800 kg 30 g

>800 kg to 1000 kg 60 g

One Central-Offices 2- Level 3, Suit No.: 302, 303 308.


info@eiac.gov.ae Office: +971 4 872 2666
www.eiac.gov.ae The Trade Centre District, Dubai-United Arab Emirates 16 of 38
Accreditation Scope
Electrical Calibration
LB-CAL-050

Accuver Calibration laboratory

Warehouse # C 45, Industrial Area 1 Qusais


Dubai-United Arab Emirates
Issue no.: 04 Date: 19-10-2023 Valid to: 17-06-2026

Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Calibration of Measuring Devices

DC Voltage Direct Method Using Up to 1 mV 4.5 µV Laboratory


Multi-product Calibrator
<1 mV to 10 mV 4.8 µV

<10 mV to 100 mV 8.2 µV

<100 mV to 200 mV 13 µV

<200 mV to 1 V 51 µV

<1 V to 2 V 83 µV

<2 V to 10 V 0.37 mV

<10 V to 20 V 0.75 mV

<20 V to 100 V 4.0 mV

<100 V to 200 V 7.7 mV

<200 V to 1000 V 41 mV

AC Voltage Direct Method Using Up to 20 mV @40 Hz 79 µV Laboratory


Multi-product Calibrator

Upto to 200 mV @56 Hz 0.12 mV

One Central-Offices 2- Level 3, Suit No.: 302, 303 308.


info@eiac.gov.ae Office: +971 4 872 2666
www.eiac.gov.ae The Trade Centre District, Dubai-United Arab Emirates 17 of 38
Accreditation Scope
Electrical Calibration
LB-CAL-050

Accuver Calibration laboratory

Warehouse # C 45, Industrial Area 1 Qusais


Dubai-United Arab Emirates
Issue no.: 04 Date: 19-10-2023 Valid to: 17-06-2026

Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Calibration of Measuring Devices

DC Voltage
AC Direct Method Using <200 mV to 2V @56 Hz 1.1 mV Laboratory
Multi-product Calibrator
<2 V to 20 V @56 Hz 11 mV

<20 V to 200 V @56 Hz 0.15 V

<200 V to 700 V @56 0.54 V


Hz
<500 V to 1000 V @ 56 0.74 V
Hz
Upto 200 mV @ 1 kHz 0.25 mV

<200 mV to 2V @ 1 kHz 2.3 mV

<2 V to 20 V @ 1 kHz 19 mV

<20 V to 200 V @ 1 kHz 0.26 V

<200 V to 700 V @ 1 1.7 V


kHz
Up to 200 mV @ 1kHz 0.26 mV
to 10 kHz

One Central-Offices 2- Level 3, Suit No.: 302, 303 308.


info@eiac.gov.ae Office: +971 4 872 2666
www.eiac.gov.ae The Trade Centre District, Dubai-United Arab Emirates 18 of 38
Accreditation Scope
Electrical Calibration
LB-CAL-050

Accuver Calibration laboratory

Warehouse # C 45, Industrial Area 1 Qusais


Dubai-United Arab Emirates
Issue no.: 04 Date: 19-10-2023 Valid to: 17-06-2026

Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Calibration of Measuring Devices

DC Voltage
AC Direct Method Using <200 mV to 2 V @ 1kHz 9.1 mV Laboratory
Multi-product Calibrator to 10 kHz
<2V to 20 V @ 1kHz to 20 mV
10 kHz
<20 V to 200 V @ 1kHz 0.30 V
to 10 kHz
Up to 200 mV @ 10 kHz 2.3 mV
to 100 kHz
<200 mV to 2 V @ 10 15 mV
kHz to 100 kHz
<2 V to 20 V @ 10 kHz 70 mV
to 100 kHz
DC Current Direct Method Using Up to to 100 µA 46 nA Laboratory
Multi product
Calibrator/ Comparison
<100 µA to 200 µA 58 nA
Method
<200 µA to 1 mA 0.14 µA

<1 mA to 2 mA 0.25 µA

<2 mA to 10 mA 0.99 µA

<10 mA to 20 mA 2.0 µA

<20 mA to 100 mA 14 µA

One Central-Offices 2- Level 3, Suit No.: 302, 303 308.


info@eiac.gov.ae Office: +971 4 872 2666
www.eiac.gov.ae The Trade Centre District, Dubai-United Arab Emirates 19 of 38
Accreditation Scope
Electrical Calibration
LB-CAL-050

Accuver Calibration laboratory

Warehouse # C 45, Industrial Area 1 Qusais


Dubai-United Arab Emirates
Issue no.: 04 Date: 19-10-2023 Valid to: 17-06-2026

Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Calibration of Measuring Devices

Voltage
DC Current Direct Method Using <100 mA to 200 mA 26 µA Laboratory
Laboratory
Multi-product
Multi product Calibrator
<200 mA to 1 A 0.23 mA
Calibrator/ Comparison
Method <1 A to 2 A 0.45 mA

<2 A to 10 A 5.7 mA

<10 A to 30 A 60 mA

DC Current Direct Method Using <10 A to 300 A 0.77 A Laboratory


Multi product Calibrator
<300 A to 1000 A 0.78 A
and Current Coil Station
<1000 A to 1250 A 0.97 A

AC Current Direct Method Using Up to 25 µA @ 40 Hz 0.31 µA Laboratory


Multi product
<25 µ to 20 mA @ 40 20 µA
Calibrator/Comparison
Hz
Method Up to 200 µA @ 56 Hz 0.46 µA
<200 µA to to 2 mA @ 2.0 µA
56 Hz
<2 mA to 10 mA @ 56 12 µA
Hz
<10 mA to 200 mA @ 0.19 mA
56 Hz
<200 mA to 2 A @ 56 3.1 mA
Hz

One Central-Offices 2- Level 3, Suit No.: 302, 303 308.


info@eiac.gov.ae Office: +971 4 872 2666
www.eiac.gov.ae The Trade Centre District, Dubai-United Arab Emirates 20 of 38
Accreditation Scope
Electrical Calibration
LB-CAL-050

Accuver Calibration laboratory


AC Current Direct Method Using Laboratory
Warehouse # C 45, Industrial Area 1 Qusais
Multi product

Dubai-United Arab Emirates


Calibrator/Comparison
Method
Issue no.: 04 Date: 19-10-2023 Valid to: 17-06-2026

Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Calibration of Measuring Devices

DC Voltage Direct Method Using <2 A to 20 A @ 56 Hz 25 mA Laboratory


Multi-product Calibrator
< 10 A to 30A @ 50 Hz 69 mA

Up to 200 µA @ 1 kHz 2.1 µA

<200 µA to to 2 mA @ 18 µA
1 kHz
<2 mA to 20 mA @ 1 0.12 mA
kHz
<20 mA to 200 mA @ 1 1.5 mA
kHz
<200 mA to 2 A @ 1 15 mA
kHz
<2 A to 20 A @ 1 kHz 94 mA

Up to 200 µA @ 1 kHz 2.2 µA


to 10 kHz
<200 µA to to 2 mA @ 17 µA
1 kHz to 10 kHz
<2 mA to 20 mA @ 1 0.12 mA
kHz to 10 kHz
<20 mA to 200 mA @ 1 1.5 mA
kHz to 10 kHz

One Central-Offices 2- Level 3, Suit No.: 302, 303 308.


info@eiac.gov.ae Office: +971 4 872 2666
www.eiac.gov.ae The Trade Centre District, Dubai-United Arab Emirates 21 of 38
Accreditation Scope
Electrical Calibration
LB-CAL-050

Accuver Calibration laboratory

Warehouse # C 45, Industrial Area 1 Qusais


Dubai-United Arab Emirates
Issue no.: 04 Date: 19-10-2023 Valid to: 17-06-2026

Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Calibration of Measuring Devices

DC Voltage Direct Method Using < 10 A to 300 A @ 56 0.77 A Laboratory


Multi-product
Multi Calibrator Hz
product Calibrator
<300 A to 1000 A @ 56 0.8 A
and Current Coil Station
Hz
<1000 A to 1250 A @ 0.98 A
56 Hz
Capacitance Direct Method Using 1 nF 32 pF Laboratory
Multi product Calibrator
10 nF 37 pF

20 nF 92 pF

50 nF 0.19 nF

100 nF 0.92 nF

1 uF 4.8 µF

10 uF 0.12 µF
Capacitance Direct Method Using 100 uF 0.71 µF Laboratory
Multi product Calibrator
1 mF 16 µF

10 mF 0.30 mF

One Central-Offices 2- Level 3, Suit No.: 302, 303 308.


info@eiac.gov.ae Office: +971 4 872 2666
www.eiac.gov.ae The Trade Centre District, Dubai-United Arab Emirates 22 of 38
Accreditation Scope
Electrical Calibration
LB-CAL-050

Accuver Calibration laboratory

Warehouse # C 45, Industrial Area 1 Qusais


Dubai-United Arab Emirates
Issue no.: 04 Date: 19-10-2023 Valid to: 17-06-2026

Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Calibration of Measuring Devices

DC Voltage
Frequency Direct Method Using Up to 100 Hz 2.3 mHz Laboratory
Multi-product
Multi Calibrator
product Calibrator
<100 Hz to 1 kHz 23 mHz

<1 kHz to 10 kHz 0.23 Hz

<10 kHz to 100 kHz 2.3 Hz

<100 kHz to 1000 kHz 24 Hz

<1 MHz to 10 MHz 58 kHz

Resistance 2 Wire Direct Method Using 100 mΩ to 1 Ω 41 mΩ Laboratory


Multi Product Calibrator <1 Ω to 10 Ω 41 mΩ

<10 Ω to 100 Ω 45 mΩ

<100 Ω to 1 kΩ 0.11 Ω

<1 kΩ to 10 kΩ 0.99 Ω
<10 kΩ to 100 kΩ 9.7 Ω

Resistance 2 Wire Direct Method Using <100 kΩ to 1 MΩ 0.18 kΩ Laboratory


Multi Product Calibrator <1 MΩ to 10 MΩ 4.8 kΩ

<10 MΩ to 100 MΩ 0.61 MΩ

<100 MΩ to 1 GΩ 12 MΩ

One Central-Offices 2- Level 3, Suit No.: 302, 303 308.


info@eiac.gov.ae Office: +971 4 872 2666
www.eiac.gov.ae The Trade Centre District, Dubai-United Arab Emirates 23 of 38
Accreditation Scope
Electrical Calibration
LB-CAL-050

Accuver Calibration laboratory

Warehouse # C 45, Industrial Area 1 Qusais


Dubai-United Arab Emirates
Issue no.: 04 Date: 19-10-2023 Valid to: 17-06-2026

Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Calibration of Measuring Devices

DC Voltage4 Wire
Resistance Direct Method Using 100 mΩ to 1Ω 5.9 mΩ Laboratory
Multi-product
Multi Calibrator <1 Ω to 10 Ω
product Calibrator 7.0 mΩ

<10 Ω to 100 Ω 12 mΩ

<100 Ω to 1 kΩ 95 mΩ

<1 kΩ to 10 kΩ 0.95 Ω

<10 kΩ to 100 kΩ 9.6 Ω

AC Power ( 1 Phase ) Direct Method Using 3 Up to 100 W 3.1 W Laboratory


phase Energy/Power < 100 W to 500 W 3.2 W
Calibrator - single phase < 500W to 1000 W 3.7 W
(30V to 300V, 0.5 A to 6
A, ±0.5 to 1 pf) < 1000 W to 1800 W 4.8 W

p.f. Lead & Lag ± 0.5 to 1 0.7 %

AC POWER ( 3Phase ) Direct Method Using 3 Up to to 300 W 8.1 W Laboratory


phase Energy/Power - 3 < 300 W to 1000 W 8.4 W
phase (30 to 300V L-N, < 1000W to 1500 W 8.7 W
0.5 to 6 A per phase,
< 1500 W to 3000 W 10 W
±0.5 to 1 pf)

< 3000 W to 5400 W 14 W

p.f. Lead & Lag ± 0.5 to 1 2.1 %

One Central-Offices 2- Level 3, Suit No.: 302, 303 308.


info@eiac.gov.ae Office: +971 4 872 2666
www.eiac.gov.ae The Trade Centre District, Dubai-United Arab Emirates 24 of 38
Accreditation Scope
Electrical Calibration
LB-CAL-050

Accuver Calibration laboratory

Warehouse # C 45, Industrial Area 1 Qusais


Dubai-United Arab Emirates
Issue no.: 04 Date: 19-10-2023 Valid to: 17-06-2026

Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Calibration of Measuring Devices

DC Voltage
Energy (1-Ph/ 3-Ph) Direct Method Using 3 Up to 300 Whr 1.2 Wh Laboratory
Multi-product
phase Calibrator
Energy/Power
< 300 W/ hr to 1.5 1.6 Wh
Calibrator - 3 phase and
kW/hr
1 phse (30V to 300V L-
< 1.5 kW/hr to 3.0 1.7 Wh
N, 0.5 A to 6 A per
kW/hr
phase, ±0.5 to 1 pf)
<3.0 kW/hr to 5.4 kW/ 3.2 Wh
hr
Defibrillator/ Comparasion Method 10 J to 20 J 0.63 J Laboratory
Defibrillator Analyzer
< 20 J to 50 J 0.83 J

< 50 J to 100 J 1.3 J

< 100 J to 200 J 2.8 J

< 200 J to 360 J 6.2 J

Insulation Resistance Direct Method Using Up to 100 kΩ 5.9 Ω Laboratory


Resistance Box/
<100 kΩ to 1 MΩ 14 kΩ
Insulation Resistance
upto @500V <1 MΩ to 5 MΩ 58 kΩ

<5 MΩ to 10 MΩ 0.12 MΩ

One Central-Offices 2- Level 3, Suit No.: 302, 303 308.


info@eiac.gov.ae Office: +971 4 872 2666
www.eiac.gov.ae The Trade Centre District, Dubai-United Arab Emirates 25 of 38
Accreditation Scope
Electrical Calibration
LB-CAL-050

Accuver Calibration laboratory

Warehouse # C 45, Industrial Area 1 Qusais


Dubai-United Arab Emirates
Issue no.: 04 Date: 19-10-2023 Valid to: 17-06-2026

Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Calibration of Measuring Devices

DC VoltageResistance
Insulation Direct Method Using <10 MΩ to 20 MΩ 0.25 MΩ Laboratory
Multi-product
Resistance Calibrator
Box/
<20 MΩ to 50 MΩ 0.61 MΩ
Insulation Resistance
upto @500V <50 MΩ to 100 MΩ 1 .5 MΩ

Direct Method Using 10 M Ω 0.1 MΩ


Resistance Box upto @5
100 M Ω 1.2 MΩ
kV
1 GΩ 12 MΩ

10 GΩ 0.12 GΩ

Earth Bond Direct Method Using Up to 4 Ω 52 mΩ Laboratory


Resistance/Earth Reference Resistances
4 to 10 Ω 58 mΩ
Resistance
10 to 100 Ω 0.14 Ω

100 to 400 Ω 0.5 Ω

Earth Bond Direct Method Using 400 to 1000 Ω 1.3 Ω Laboratory


Resistance/Earth Reference Resistances
1000 to 2000 Ω 2.4 Ω
Resistance
2000 to 3000 Ω 3.6 Ω

One Central-Offices 2- Level 3, Suit No.: 302, 303 308.


info@eiac.gov.ae Office: +971 4 872 2666
www.eiac.gov.ae The Trade Centre District, Dubai-United Arab Emirates 26 of 38
Accreditation Scope
Electrical Calibration
LB-CAL-050

Accuver Calibration laboratory

Warehouse # C 45, Industrial Area 1 Qusais


Dubai-United Arab Emirates
Issue no.: 04 Date: 19-10-2023 Valid to: 17-06-2026

Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Calibration of Sourcing Devices

DC Voltage Direct Method Using Up to 1 mV 4.4 µV Laboratory


Reference Multimeter
<1 mV to 10 mV 5.2 µV

<10 mV to 100 mV 11 µV

<100 mV to 0.5 V 38 µV

<0.5 V to 1 V 57 µV

<1 V to 5 V 0.44 mV

<5 V to 10 V 3.7 mV

<10 to 50 V 50 mV

<50 to 100 V 57 mV

<100 to 500 V 71 mV

<500 to 1000 V 71 mV

AC Voltage Direct Method Using Upto 10 mV @ 45 Hz 47 µV Laboratory


Reference Multimeter
Upto to 100 mV @ 50 0.26 mV
Hz

One Central-Offices 2- Level 3, Suit No.: 302, 303 308.


info@eiac.gov.ae Office: +971 4 872 2666
www.eiac.gov.ae The Trade Centre District, Dubai-United Arab Emirates 27 of 38
Accreditation Scope
Electrical Calibration
LB-CAL-050

Accuver Calibration laboratory

Warehouse # C 45, Industrial Area 1 Qusais


Dubai-United Arab Emirates
Issue no.: 04 Date: 19-10-2023 Valid to: 17-06-2026

Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Calibration of Sourcing Devices

DC Voltage
AC Direct Method Using < 100 mV to 0.5 V @ 50 1.9 mV Laboratory
Reference Multimeter Hz
< 0.5 V to 1 V @ 50 Hz 3.7 mV

< 1 V to 5 V @ 50 Hz 20 mV

< 5 V to 10 V @ 50 Hz 37 mV

< 10 V to 50 V @ 50 Hz 1.2 V

< 50 V to 100 V @ 50 1.2 V


Hz
< 100 V to 500 V @ 50 4.9 V
Hz
< 500 V to 1000 V @ 50 9.4 V
Hz
Upto 200 V @ 1 kHz 1.4 V

<200 V to 1000 V @ 1 1.4 V


kHz
Upto 2mV @ 10 kHz 48 µV

<2 mV to 10 mV @ 10 54 µV
kHz
< 10 mV to 100 mV @ 0.15 mV
10 kHz
< 100 mV to 1 V @10 1.1 mV
kHz

One Central-Offices 2- Level 3, Suit No.: 302, 303 308.


info@eiac.gov.ae Office: +971 4 872 2666
www.eiac.gov.ae The Trade Centre District, Dubai-United Arab Emirates 28 of 38
Accreditation Scope
Electrical Calibration
LB-CAL-050

Accuver Calibration laboratory

Warehouse # C 45, Industrial Area 1 Qusais


Dubai-United Arab Emirates
Issue no.: 04 Date: 19-10-2023 Valid to: 17-06-2026

Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Calibration of Sourcing Devices

DC Voltage
AC Direct Method Using < 1 V to 10 V @ 10 kHz 27 mV Laboratory
Reference Multimeter
< 10 V to 100 V @ 10 1.3 V
kHz
Upto 20 mV @ 10 kHz 90 µV
to 100 kHz
<20 mV to 200 mV @ 30 mV
10 kHz to 100 kHz
<200 mV to 2 V @ 10 37 mV
kHz to 100 kHz
DC Current Direct Method Using Up to 10 µA 35 nA Laboratory
Reference Multimeter
DC Current Direct Method Using <10 µA to 100 µA 0.12 nA Laboratory
Reference Multimeter
<100 µA to 0.5 mA 0.55 μA
/Comparasion Method
<0.5 mA to 1 mA 0.93 μA

<1 mA to 5mA 8.2 μA

<5 mA to 10 mA 12 μA

<10 mA to <50 mA 47 μA

<50 mA to 100 mA 88 μA

<100 mA to 200 mA 0.18 mA

One Central-Offices 2- Level 3, Suit No.: 302, 303 308.


info@eiac.gov.ae Office: +971 4 872 2666
www.eiac.gov.ae The Trade Centre District, Dubai-United Arab Emirates 29 of 38
Accreditation Scope
Electrical Calibration
LB-CAL-050

Accuver Calibration laboratory

Warehouse # C 45, Industrial Area 1 Qusais


Dubai-United Arab Emirates
Issue no.: 04 Date: 19-10-2023 Valid to: 17-06-2026

Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Calibration of Sourcing Devices

Voltage
DC Current Direct Method Using <200 mA to 0.4 A 0.35 mA Laboratory
Reference Multimeter
0.4 A to 0.5 A 0.62 mA
/Comparasion Method
<0.5 A to 1 A 5.5 mA

<1 A to 2 A 8.0 mA

<2 A to 3 A 9.3 mA

DC Current Direct Method Using <3 A to 5 A 14 mA Laboratory


Reference Multimeter
<5 A to 10 A 22 mA
/Comparasion Method
< 10 µA to 50 µA @ 50 0.16 µA
Hz
< 50 µA to 100 µA @ 50 0.24 µA
Hz
< 100 µA to 0.5 mA @ 1.0 µA
50 Hz
< 0.5 mA to 1 mA @ 50 1.6 µA
Hz
< 1 mA to 5mA @ 50 Hz 16 µA

< 5 mA to 10 mA @ 50 24 µA
Hz
< 10 mA to 50 mA @ 50 0.10 mA
Hz
< 50 mA to 100 mA @ 0.16 mA
50 Hz
One Central-Offices 2- Level 3, Suit No.: 302, 303 308.
info@eiac.gov.ae Office: +971 4 872 2666
www.eiac.gov.ae The Trade Centre District, Dubai-United Arab Emirates 30 of 38
Accreditation Scope
Electrical Calibration
LB-CAL-050

Accuver Calibration laboratory

Warehouse # C 45, Industrial Area 1 Qusais


Dubai-United Arab Emirates
Issue no.: 04 Date: 19-10-2023 Valid to: 17-06-2026

Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Calibration of Sourcing Devices

Voltage
DC Current Direct Method Using < 100 mA to 200 mA @ 0.99 mA Laboratory
Reference Multimeter 50 Hz
< 200 mA to 0.4 A @ 50 1.2 mA
/Comparasion Method
Hz
0.4 A to 0.5 A @ 50 Hz 1.3 mA

AC Current Direct Method Using Up to 100 µA @ 45 Hz 0.34 µA Laboratory


Reference Multimeter
<100 µA to 0.5 mA @ 1.6 µA
/Comparasion Method
45 Hz
<0.5 mA to 1 mA @ 45 6.1 µA
Hz
<1 mA to 5mA @ 45 Hz 19 µA

<5 mA to 10 mA @ 45 30 µA
Hz
<10 mA to 50 mA @ 45 0.13 mA
Hz
<50 mA to 100 mA @ 0.22 mA
45 Hz
< 100 mA to 0.4 A @ 1 0.96 mA
kHz
<200 mA to 0.4 A @ 50 2.1 mA
Hz
0.4 A to 0.5 A @ 50 Hz 2.2 mA

<0.5 A to 1 A @ 50 Hz 4.3 mA

One Central-Offices 2- Level 3, Suit No.: 302, 303 308.


info@eiac.gov.ae Office: +971 4 872 2666
www.eiac.gov.ae The Trade Centre District, Dubai-United Arab Emirates 31 of 38
Accreditation Scope
Electrical Calibration
LB-CAL-050

Accuver Calibration laboratory

Warehouse # C 45, Industrial Area 1 Qusais


Dubai-United Arab Emirates
Issue no.: 04 Date: 19-10-2023 Valid to: 17-06-2026

Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Calibration of Sourcing Devices

DC Current
AC Voltage Direct Method Using <1 A to 2 A @ 50 Hz 7.8 mA Laboratory
Reference Multimeter
<2 A to 3 A @ 50 Hz 12 mA
/Comparasion Method
<3 A to 5 A @ 50 Hz 22 mA

<5 A to 10 A @ 50 Hz 39 mA

Up to 40 µA @ 1 kHz 0.25 µA

<40 uA to 1 mA @ 1 6.2 µA
kHz
<1 mA to 10 mA @ 1 26 µA
kHz
<10 mA to 100 mA @ 1 0.17 mA
kHz
<100 mA to 0.4 A @ 1 0.96 mA
kHz
0.4 A to 1A @ 1 kHz 1.9 mA

<1 A to 3 A @ 1 kHz 8.0 mA

<3 A to 5 A @ 1 kHz 16 mA

<5 A to 10 A @ 1 kHz 27 mA

One Central-Offices 2- Level 3, Suit No.: 302, 303 308.


info@eiac.gov.ae Office: +971 4 872 2666
www.eiac.gov.ae The Trade Centre District, Dubai-United Arab Emirates 32 of 38
Accreditation Scope
Electrical Calibration
LB-CAL-050

Accuver Calibration laboratory

Warehouse # C 45, Industrial Area 1 Qusais


Dubai-United Arab Emirates
Issue no.: 04 Date: 19-10-2023 Valid to: 17-06-2026

Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Calibration of Sourcing Devices

DC Voltage
Capacitance Direct Method Using Up to 1 nF 59 pF Laboratory
Reference Multimeter
1 nF to 10 nF 0.25 nF

< 10 nF to 100 nF 2.7 nF

< 100 nF to 1 µF 25 nF
< 1 µF to 10 µF 0.19 µF

< 10 µF to 100 µF 1.9 µF

< 100 µF to 1 mF 19 µF
< 1 mF to 10 mF 0.13 mF

Frequency Direct Method Using Up to 10 Hz 0.58 Hz Laboratory


Reference Multimeter 10 Hz to 50 Hz 0.58 Hz
/Comparasion Method
<50 Hz to 100 Hz 0.58 Hz

Frequency Direct Method Using <100 Hz to 1 kHz 0.58 Hz Laboratory


Reference Multimeter
<1 kHz to 10 kHz 0.58 kHz
/Comparasion Method
<10 kHz to 100 kHz 0.58 kHz

<100 kHz to 300 kHz 1.2 kHz

<300 kHz to 999 kHz 3.4 kHz

One Central-Offices 2- Level 3, Suit No.: 302, 303 308.


info@eiac.gov.ae Office: +971 4 872 2666
www.eiac.gov.ae The Trade Centre District, Dubai-United Arab Emirates 33 of 38
Accreditation Scope
Electrical Calibration
LB-CAL-050

Accuver Calibration laboratory

Warehouse # C 45, Industrial Area 1 Qusais


Dubai-United Arab Emirates
Issue no.: 04 Date: 19-10-2023 Valid to: 17-06-2026

Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Calibration of Sourcing Devices

DC Voltage Decade
Resistances/ Direct Method Using Up to 1Ω 4.4 mΩ Laboratory
resistance boxes Reference Multimeter
<1 Ω to 10 Ω 5.1 mΩ
Multimeter/Comparison
Method <10Ω to 100Ω 26 mΩ

<100 Ω to 1 kΩ 0.24 Ω

<1 kΩ to 10 kΩ 2.4 Ω

<10 kΩ to 100 kΩ 13 Ω

<100 kΩ to 1 MΩ 0.15 kΩ

<1 MΩ to 10 MΩ 5.3 kΩ

Resistances/ Decade Direct Method Using <10 MΩ to 100 MΩ 0.93 MΩ Laboratory


resistance boxes Reference <100 MΩ to 300 MΩ 3.1 MΩ
Multimeter/Comparison
<300 MΩ to 1000 MΩ 22 MΩ
Method
Inductance -Measuring Direct Method Using 1 mH 64 µH Laboratory
Instruments Multi product Calibrator
10 mH 0.12 mH

19 mH 0.18 mH

29 mH 0.24 mH

50 mH 0.36 mH

One Central-Offices 2- Level 3, Suit No.: 302, 303 308.


info@eiac.gov.ae Office: +971 4 872 2666
www.eiac.gov.ae The Trade Centre District, Dubai-United Arab Emirates 34 of 38
Accreditation Scope
Electrical Calibration
LB-CAL-050

Accuver Calibration laboratory

Warehouse # C 45, Industrial Area 1 Qusais


Dubai-United Arab Emirates
Issue no.: 04 Date: 19-10-2023 Valid to: 17-06-2026

Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Calibration of Sourcing Devices

DC Voltage -Measuring
Inductance Direct Method Using 100 mH 0.67 mH Laboratory
Instruments Reference
Multi Multimeter
product Calibrator
1H 8.5 mH

10 H 60 mH

Low Resistance Ohm Direct 4 wire 1 mΩ to 10 mΩ 96 µΩ Laboratory


Meter -Measuring measurement using
>10 mΩ to 100 mΩ 0.6 mΩ
Instruments Precision Decade
Resistance box (Upto 10 100 mΩ to 500 mΩ
Direct 4 wire 3.0 mΩ
measurement using
Precision Decade
Resistance box (Upto 1.6
A)
Direct 4 wire 500 mΩ to 1000 mΩ 6.0 mΩ
measurement using
Precision Decade
Resistance box (Upto 1.6
A)

One Central-Offices 2- Level 3, Suit No.: 302, 303 308.


info@eiac.gov.ae Office: +971 4 872 2666
www.eiac.gov.ae The Trade Centre District, Dubai-United Arab Emirates 35 of 38
Accreditation Scope
Electrical Calibration
LB-CAL-050

Accuver Calibration laboratory

Warehouse # C 45, Industrial Area 1 Qusais


Dubai-United Arab Emirates
Issue no.: 04 Date: 19-10-2023 Valid to: 17-06-2026

Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Calibration of Sourcing Devices

DC Voltage
Low Resistance Ohm Method
Direct 4 wire Using 1 Ω to 5 Ω 11 mΩ Laboratory
Meter -Measuring Reference Multimeter
measurement using
Instruments Precision Decade
Resistance box (Upto
200 mA)
>5 Ω to 10 Ω 59 mΩ

>10 Ω to 100 Ω 0.11 Ω

>100 Ω to 500 Ω 0.66 Ω

>500 Ω to 1000 Ω 0.85 Ω

>1000 Ω to 2000 Ω 1.4 Ω

Low/Shunt/Contact V/I method using up to 100 mΩ 0.67 mΩ Laboratory


Resistance -Sourcing Multiproduct Calibrator
>100 mΩ to 1000 mΩ 1.9 mΩ
Instruments and Reference
Multimeter (Up to 20 A) >1000 mΩ to 10 Ω 0.10 Ω

One Central-Offices 2- Level 3, Suit No.: 302, 303 308.


info@eiac.gov.ae Office: +971 4 872 2666
www.eiac.gov.ae The Trade Centre District, Dubai-United Arab Emirates 36 of 38
Accreditation Scope
Volume Calibration
LB-CAL-050

Accuver Calibration laboratory

Warehouse # C 45, Industrial Area 1 Qusais


Dubai-United Arab Emirates
Issue no.: 01 Date: 19-10-2023 Valid to: 17-06-2026

Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Liquid Volume /Piston Gravimetric method ( 10 < V < 100 μl 0.13 μl Laboratory
operated volumetric ISO 8655-6:2002)
apparatus( pipettes /
Dispensers / Repeaters
/Dilutors )

100 < V < 500 μl 0.52 μl Laboratory

0.5 < V < 1 ml 1.3 μl Laboratory

1 < V < 10 ml 3.6 μl Laboratory

One Central-Offices 2- Level 3, Suit No.: 302, 303 308.


info@eiac.gov.ae Office: +971 4 872 2666
www.eiac.gov.ae The Trade Centre District, Dubai-United Arab Emirates 37 of 38
Accreditation Scope
Torque Calibration
LB-CAL-050

Accuver Calibration laboratory

Warehouse # C 45, Industrial Area 1 Qusais


Dubai-United Arab Emirates
Issue no.: 01 Date: 19-10-2023 Valid to: 17-06-2026

Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Torque tools/ Indicating
and Hand Torque Tools Based on ISO 6789 1&2 0.05 to 0.5 Nm 0.80% Laboratory

Based on ISO 6789 1&2 0.5 to 5 Nm 0.60% Laboratory

Based on ISO 6789 1&2 5 to 50 Nm 0.50% Laboratory

Based on ISO 6789 1&2 50 to 500 Nm 0.60% Laboratory

Based on ISO 6789 1&2 500 Nm - 2000 Nm 0.50% Laboratory