ISO/IEC 17025:2017
This Accreditation is invalid without the attached accreditation scope and shall remain in force within the validity
period printed below, subject to continuing compliance with the requirements of the accreditation criteria.
Accreditation History
Mass 04
Balance 03
Elactrical 04
Volume 01
Torque 01
Pressure 04 Certificate validity was extended for 6 months from 18-06- 18-06-2023
2023 up to 17-12-2023
Temperature & Humidity 03
Dimensional 02
Mass 03
Balance 2
Elactrical 03
Temperature & Humidity 02 Missed parameters from last scope update 20-12-2021
info@eiac.gov.ae One Central-Offices 2- Level 3, Suit No.: 302, 303 308. Office: +971 4 872 2666
www.eiac.gov.ae The Trade Centre District, Dubai-United Arab Emirates 1 of 38
Accreditation Scope
10-05-2021
LB-CAL-050
Temperature & Humidity 01 Granted accreditation from Emirates International
Accreditation Centre EIAC
Dimensional 01
Mass 01
Balance 01
Elactrical 01
Pressure 02 Renewal accreditation and first issuance under the name of 14-07-2020
EIAC
Pressure 01 Granted accreditation from Dubai Accreditation Center 18-06-2017
'DAC'
info@eiac.gov.ae One Central-Offices 2- Level 3, Suit No.: 302, 303 308. Office: +971 4 872 2666
www.eiac.gov.ae The Trade Centre District, Dubai-United Arab Emirates 2 of 38
Accreditation Scope
Pressure Calibration
LB-CAL-050
Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
pneumatic Pressure DMS 2016 based on BS -87 kPa to 0 Mpa 1 kPa Laboratory/
(gauge) (Digital and EN 837-1:1998 Customer
Analogue) Premises
Pneumatic Pressure Based on DKD-R - 6-1 -87 kPa to 0 MPa 1 kPa Laboratory/
indicators/Transmitters ,2014 and EURAMET CG Customer
(Digital and Analogue) 17 Premises
Hydraulic Pressure DMS 2016 based on BS 0 MPa to 100 MPa 0.02 MPa + 2.0x 10-4 pe Laboratory/
(gauges) (Digital and EN 837-1:1998 Customer
Analogue) Premises
Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Differential Pressure Based on DKD-R - 6-1 0 to 175 kPa 0.5 kPa Laboratory/
Gauge ,2014 and EURAMET CG Customer
17 Premises
Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Liquid in Glass (CP/06/T-04) based on -30°C to 0°C 0.9 °C Laboratory
Thermometer BIS IS 6274
0°C to 300°C 1.7 °C
Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Liquid in
Drying GlassIncubator,
Oven, (CP/06/T-04) based on -80°C to 0°C
(CP/06/T-08) 0.34 °C Laboratory
Laboratory/
Thermometer
Chiller/ Freezer/ BIS ISR.5-7
DKD 6274 Customer
0°C to 250°C 0.89 °C
Refrigerator, Autoclave, Premises
Furnace, Hot Cabinet,
Environmental
Direct Reading Chamber (CP/06/T-03) based on -80°C to 300°C 0.22 °C Laboratory/
Thermometer DKD R5-1 Customer
Premises
Digital/ Dial (CP/06/T-03) based on -50°C to 200°C 0.9 °C Laboratory/
Thermometer EN 13190 Customer
200°C to 600°C 0.9 °C
Premises
600°C to 1200°C 4.0 °C
Water Bath/ Oil Bath (CP/06/T-06) based on 30°C to 100°C 0.17°C Laboratory/
Euramet cg-13. Customer
100°C to 300°C 0.24°C
Premises
Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Liquid in Glass /
HYGROMETER (CP/06/T-04) based on 30 to 60 % RH
(CP/06/T-10) 1.8 % RH Laboratory
LABORATORY
Thermometer
HUMIDITY / BIS IS 6274
Euramet cg-20
Temperature Humidity
Measuring Location in Comparison method (CP- -80 to 200 °C 0.7°C LABORATORY
Chiller, Freezer, 06/T-16) based on / CUSTOMER
Incubator, Oven, co2 (DKD R5-7 (Method C)). PREMISES
incubator, Dish washers,
Measuring location in Comparison method (CP- 250 to 500 °C 3.7 °C LABORATORY
Furnaces 06/T-14) based on / CUSTOMER
500 to 1500 °C 5.0 °C
(DKD R5-7 (Method C)). PREMISES
Measuring Location in Comparison method (CP-20 %RH to 60 %RH 2.4 %RH LABORATORY
Humidity Chambers 06/T-15) based on / CUSTOMER
60 %RH to 90 %RH 2.7 % RH
(DKD R5-7 (Method C)). PREMISES
Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Liquid in Glass (CP/06/T-04) based on Laboratory
Thermometer BIS IS 6274
Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Caliper (Vernier/ Dial/ CP/03/DIM-01 0-600 mm 21 µm Laboratory
Digital) Based on IS 3651- 1&2
Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Caliper Based on IS 3651 -1 &2 > 600 mm - 1000 mm 35 µm Laboratory
(Vernier/Dial/Digital) CP/03/DIM-01 Based
on IS 3651 -1 &2
Calibration Measurement
Calibration Field/
Calibration Method Range and Specification Capability Location
Measuring Quality
(CMC)*
Oscilloscope & Time Direct Method Using > 10 ns to 100 ns 0.6 ns Laboratory/
Base Waveform Generator Customer
> 100 ns to 1 us 5.8 ns
Premises
> 1 us to 10 us 0.058 μs
> 1 ms to 10 ms 58 μs
> 100 ms to 1 s 58 ms
> 5 V to 7 V 0.08 V
> 7 V to 10 V 0.12 V
Calibration Measurement
Calibration Field/
Calibration Method Range and Specification Capability Location
Measuring Quality
(CMC)*
Tachometer Direct Method using non 60 to 600 rpm 0.2 rpm Laboratory/
Contact tachometer Customer
601 rpm to 6000 rpm 1.2 rpm
adpater & Multiproduct Premises
Calibrator 6001 rpm to 12000 rpm 1.8 rpm
Calibration Measurement
Calibration Field/
Calibration Method Range and Specification Capability Location
Measuring Quality
(CMC)*
Oscilloscope
Centrifuge & Time
/ Variable Direct MethodMethod
Comparasion Using 1 rpm 60 rpm 0.2 rpm Laboratory/
Base
Rotation Speed Waveform
using Generator
non Contact Customer
61 rpm to 120 rpm 1.4 rpm
tachometer Premises
121 to 600 rpm 1.6 rpm
> 10 hr to 15 hr 4.8 s
> 15 hr to 24 hr 35 s
> 24 hr to < 100 hr 40 s
OSCILLOSCOPE & Direct Method Using upto 50 MHz 7.1 kHz LABORATORY
BANDWIDTH (F) Waveform Generator / Customer
>50 MHz upto 100 MHz 7.1 kHz
Premises
Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Mass OIML R111-1.2004 0.001g 0.041 mg Laboratory
0.002g 0.041 mg
0.005g 0.042 mg
0.01g 0.042 mg
0.02g 0.042 mg
0.05g 0.042 mg
0.1g 0.043 mg
0.2g 0.045 mg
0.5g 0.040 mg
1g 0.050 mg
2g 0.061 mg
5g 0.065 mg
10g 0.085 mg
20g 0.09 mg
Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Mass OIML R111-1.2004 50g 0.12 mg Laboratory
100g 0.23 mg
200g 0.63 mg
500g 1.1 mg
1kg 2.1 mg
2Kg 3.2 mg
5kg 4.3 mg
10kg 5.4 mg
20kg 11 mg
Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Weighing Balance EUROMET CG 18 V4 1mg to 20g 0.44 mg Customer
Premises
> 20 g to 200g 0.75 mg
> 1 kg to 10 kg 11 mg
300 kg to 800 kg 30 g
>800 kg to 1000 kg 60 g
Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Calibration of Measuring Devices
<100 mV to 200 mV 13 µV
<200 mV to 1 V 51 µV
<1 V to 2 V 83 µV
<2 V to 10 V 0.37 mV
<10 V to 20 V 0.75 mV
<200 V to 1000 V 41 mV
Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Calibration of Measuring Devices
DC Voltage
AC Direct Method Using <200 mV to 2V @56 Hz 1.1 mV Laboratory
Multi-product Calibrator
<2 V to 20 V @56 Hz 11 mV
<2 V to 20 V @ 1 kHz 19 mV
Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Calibration of Measuring Devices
DC Voltage
AC Direct Method Using <200 mV to 2 V @ 1kHz 9.1 mV Laboratory
Multi-product Calibrator to 10 kHz
<2V to 20 V @ 1kHz to 20 mV
10 kHz
<20 V to 200 V @ 1kHz 0.30 V
to 10 kHz
Up to 200 mV @ 10 kHz 2.3 mV
to 100 kHz
<200 mV to 2 V @ 10 15 mV
kHz to 100 kHz
<2 V to 20 V @ 10 kHz 70 mV
to 100 kHz
DC Current Direct Method Using Up to to 100 µA 46 nA Laboratory
Multi product
Calibrator/ Comparison
<100 µA to 200 µA 58 nA
Method
<200 µA to 1 mA 0.14 µA
<1 mA to 2 mA 0.25 µA
<2 mA to 10 mA 0.99 µA
<10 mA to 20 mA 2.0 µA
<20 mA to 100 mA 14 µA
Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Calibration of Measuring Devices
Voltage
DC Current Direct Method Using <100 mA to 200 mA 26 µA Laboratory
Laboratory
Multi-product
Multi product Calibrator
<200 mA to 1 A 0.23 mA
Calibrator/ Comparison
Method <1 A to 2 A 0.45 mA
<2 A to 10 A 5.7 mA
<10 A to 30 A 60 mA
Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Calibration of Measuring Devices
<200 µA to to 2 mA @ 18 µA
1 kHz
<2 mA to 20 mA @ 1 0.12 mA
kHz
<20 mA to 200 mA @ 1 1.5 mA
kHz
<200 mA to 2 A @ 1 15 mA
kHz
<2 A to 20 A @ 1 kHz 94 mA
Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Calibration of Measuring Devices
20 nF 92 pF
50 nF 0.19 nF
100 nF 0.92 nF
1 uF 4.8 µF
10 uF 0.12 µF
Capacitance Direct Method Using 100 uF 0.71 µF Laboratory
Multi product Calibrator
1 mF 16 µF
10 mF 0.30 mF
Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Calibration of Measuring Devices
DC Voltage
Frequency Direct Method Using Up to 100 Hz 2.3 mHz Laboratory
Multi-product
Multi Calibrator
product Calibrator
<100 Hz to 1 kHz 23 mHz
<10 Ω to 100 Ω 45 mΩ
<100 Ω to 1 kΩ 0.11 Ω
<1 kΩ to 10 kΩ 0.99 Ω
<10 kΩ to 100 kΩ 9.7 Ω
<100 MΩ to 1 GΩ 12 MΩ
Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Calibration of Measuring Devices
DC Voltage4 Wire
Resistance Direct Method Using 100 mΩ to 1Ω 5.9 mΩ Laboratory
Multi-product
Multi Calibrator <1 Ω to 10 Ω
product Calibrator 7.0 mΩ
<10 Ω to 100 Ω 12 mΩ
<100 Ω to 1 kΩ 95 mΩ
<1 kΩ to 10 kΩ 0.95 Ω
Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Calibration of Measuring Devices
DC Voltage
Energy (1-Ph/ 3-Ph) Direct Method Using 3 Up to 300 Whr 1.2 Wh Laboratory
Multi-product
phase Calibrator
Energy/Power
< 300 W/ hr to 1.5 1.6 Wh
Calibrator - 3 phase and
kW/hr
1 phse (30V to 300V L-
< 1.5 kW/hr to 3.0 1.7 Wh
N, 0.5 A to 6 A per
kW/hr
phase, ±0.5 to 1 pf)
<3.0 kW/hr to 5.4 kW/ 3.2 Wh
hr
Defibrillator/ Comparasion Method 10 J to 20 J 0.63 J Laboratory
Defibrillator Analyzer
< 20 J to 50 J 0.83 J
<5 MΩ to 10 MΩ 0.12 MΩ
Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Calibration of Measuring Devices
DC VoltageResistance
Insulation Direct Method Using <10 MΩ to 20 MΩ 0.25 MΩ Laboratory
Multi-product
Resistance Calibrator
Box/
<20 MΩ to 50 MΩ 0.61 MΩ
Insulation Resistance
upto @500V <50 MΩ to 100 MΩ 1 .5 MΩ
10 GΩ 0.12 GΩ
Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Calibration of Sourcing Devices
<10 mV to 100 mV 11 µV
<100 mV to 0.5 V 38 µV
<0.5 V to 1 V 57 µV
<1 V to 5 V 0.44 mV
<5 V to 10 V 3.7 mV
<10 to 50 V 50 mV
<50 to 100 V 57 mV
<100 to 500 V 71 mV
<500 to 1000 V 71 mV
Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Calibration of Sourcing Devices
DC Voltage
AC Direct Method Using < 100 mV to 0.5 V @ 50 1.9 mV Laboratory
Reference Multimeter Hz
< 0.5 V to 1 V @ 50 Hz 3.7 mV
< 1 V to 5 V @ 50 Hz 20 mV
< 5 V to 10 V @ 50 Hz 37 mV
< 10 V to 50 V @ 50 Hz 1.2 V
<2 mV to 10 mV @ 10 54 µV
kHz
< 10 mV to 100 mV @ 0.15 mV
10 kHz
< 100 mV to 1 V @10 1.1 mV
kHz
Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Calibration of Sourcing Devices
DC Voltage
AC Direct Method Using < 1 V to 10 V @ 10 kHz 27 mV Laboratory
Reference Multimeter
< 10 V to 100 V @ 10 1.3 V
kHz
Upto 20 mV @ 10 kHz 90 µV
to 100 kHz
<20 mV to 200 mV @ 30 mV
10 kHz to 100 kHz
<200 mV to 2 V @ 10 37 mV
kHz to 100 kHz
DC Current Direct Method Using Up to 10 µA 35 nA Laboratory
Reference Multimeter
DC Current Direct Method Using <10 µA to 100 µA 0.12 nA Laboratory
Reference Multimeter
<100 µA to 0.5 mA 0.55 μA
/Comparasion Method
<0.5 mA to 1 mA 0.93 μA
<5 mA to 10 mA 12 μA
<10 mA to <50 mA 47 μA
<50 mA to 100 mA 88 μA
Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Calibration of Sourcing Devices
Voltage
DC Current Direct Method Using <200 mA to 0.4 A 0.35 mA Laboratory
Reference Multimeter
0.4 A to 0.5 A 0.62 mA
/Comparasion Method
<0.5 A to 1 A 5.5 mA
<1 A to 2 A 8.0 mA
<2 A to 3 A 9.3 mA
< 5 mA to 10 mA @ 50 24 µA
Hz
< 10 mA to 50 mA @ 50 0.10 mA
Hz
< 50 mA to 100 mA @ 0.16 mA
50 Hz
One Central-Offices 2- Level 3, Suit No.: 302, 303 308.
info@eiac.gov.ae Office: +971 4 872 2666
www.eiac.gov.ae The Trade Centre District, Dubai-United Arab Emirates 30 of 38
Accreditation Scope
Electrical Calibration
LB-CAL-050
Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Calibration of Sourcing Devices
Voltage
DC Current Direct Method Using < 100 mA to 200 mA @ 0.99 mA Laboratory
Reference Multimeter 50 Hz
< 200 mA to 0.4 A @ 50 1.2 mA
/Comparasion Method
Hz
0.4 A to 0.5 A @ 50 Hz 1.3 mA
<5 mA to 10 mA @ 45 30 µA
Hz
<10 mA to 50 mA @ 45 0.13 mA
Hz
<50 mA to 100 mA @ 0.22 mA
45 Hz
< 100 mA to 0.4 A @ 1 0.96 mA
kHz
<200 mA to 0.4 A @ 50 2.1 mA
Hz
0.4 A to 0.5 A @ 50 Hz 2.2 mA
<0.5 A to 1 A @ 50 Hz 4.3 mA
Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Calibration of Sourcing Devices
DC Current
AC Voltage Direct Method Using <1 A to 2 A @ 50 Hz 7.8 mA Laboratory
Reference Multimeter
<2 A to 3 A @ 50 Hz 12 mA
/Comparasion Method
<3 A to 5 A @ 50 Hz 22 mA
<5 A to 10 A @ 50 Hz 39 mA
Up to 40 µA @ 1 kHz 0.25 µA
<40 uA to 1 mA @ 1 6.2 µA
kHz
<1 mA to 10 mA @ 1 26 µA
kHz
<10 mA to 100 mA @ 1 0.17 mA
kHz
<100 mA to 0.4 A @ 1 0.96 mA
kHz
0.4 A to 1A @ 1 kHz 1.9 mA
<3 A to 5 A @ 1 kHz 16 mA
<5 A to 10 A @ 1 kHz 27 mA
Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Calibration of Sourcing Devices
DC Voltage
Capacitance Direct Method Using Up to 1 nF 59 pF Laboratory
Reference Multimeter
1 nF to 10 nF 0.25 nF
< 100 nF to 1 µF 25 nF
< 1 µF to 10 µF 0.19 µF
< 100 µF to 1 mF 19 µF
< 1 mF to 10 mF 0.13 mF
Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Calibration of Sourcing Devices
DC Voltage Decade
Resistances/ Direct Method Using Up to 1Ω 4.4 mΩ Laboratory
resistance boxes Reference Multimeter
<1 Ω to 10 Ω 5.1 mΩ
Multimeter/Comparison
Method <10Ω to 100Ω 26 mΩ
<100 Ω to 1 kΩ 0.24 Ω
<1 kΩ to 10 kΩ 2.4 Ω
<10 kΩ to 100 kΩ 13 Ω
<100 kΩ to 1 MΩ 0.15 kΩ
<1 MΩ to 10 MΩ 5.3 kΩ
19 mH 0.18 mH
29 mH 0.24 mH
50 mH 0.36 mH
Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Calibration of Sourcing Devices
DC Voltage -Measuring
Inductance Direct Method Using 100 mH 0.67 mH Laboratory
Instruments Reference
Multi Multimeter
product Calibrator
1H 8.5 mH
10 H 60 mH
Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Calibration of Sourcing Devices
DC Voltage
Low Resistance Ohm Method
Direct 4 wire Using 1 Ω to 5 Ω 11 mΩ Laboratory
Meter -Measuring Reference Multimeter
measurement using
Instruments Precision Decade
Resistance box (Upto
200 mA)
>5 Ω to 10 Ω 59 mΩ
Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Liquid Volume /Piston Gravimetric method ( 10 < V < 100 μl 0.13 μl Laboratory
operated volumetric ISO 8655-6:2002)
apparatus( pipettes /
Dispensers / Repeaters
/Dilutors )
Calibration
Calibration Field/ Range and Measurement
Calibration Method Location
Measuring Quality Specification Capability
(CMC)*
Torque tools/ Indicating
and Hand Torque Tools Based on ISO 6789 1&2 0.05 to 0.5 Nm 0.80% Laboratory