Nip amet etee ere) 1. Introduction ‘These specifications cover the technical specifications for an advance MPPT Photovoltaic Charge Controller with the operating voltage of (48VDC) Positive ground to use for telecom load 2.1 Operating Environment Conditions i) Ambient Temperature: 10°C to + 55 °C. ii) Relative Humidit up to 90%. Altitude: up to 3000metres above mean see level. 2. Technical Specifications for Solar Charge Control Unit (SCCU) and Load Control: 3.1 General The solar charge controller shall be designed for heavy duty use and shall be provided to contro! the charging of batteries from photovoltaic panels and to control the load. 3.2 Features The Solar Charge Controller (SCC) shall meet the following features Advanced MPPT Technology with high Efficiency | * LCD Display: Multifunction digital LCD with keypad displays system data and status, * Control and management: Charge regulation, battery management parameters and load control parameters are fully adjustable and programmable to meet different requirements. = Battery Compatibility: Sealed, Gel, flooded , lithium ion and user. * Multistage charging optimizes battery performance, MPT efficiency > 98%, Peak conversion efficiency 98%. * Installation: Suitable for Indoor installation and easily install in parallel connection Battery system Voltage: (48V D.C) Positive ground. Charge controller Rating Output: Each Solar Charger controller capacity shall meet the following: "Charging current is (100 ~ 120)Amp DC at 40°C. * Discharge current (Rated Load Current) is (60 ) Amp DC at least 3.5 PV input Voltage: - Max. PV input voltage(VOC) : 400VDC at least. ~ Start the charge voltage point: less than 100VDC - Overvoltage protection point: SOOVDC at least. 3.6 Digital (display Led indicators} 1) Digital Display : | ~ Solar charge controller should have Multifunction liquid crystal display (LCD) with keypad for Configuration and system monitoring. 2) Measures: ! SCC which indicates at least the following parameters: harging Current and Battery Ah * Battery Display: Battery Voltage, Batter nd current. + PV Solar Display: PV panel Voltage, * Load Display: Load voltage and current 3) LED Indicators ‘ The following Visible LED indications shall be provided: ee_a———o— Page TofS i — CRT een ie * Charging status: Charge On/Charge Stop = Battery fully charged / Battery low voltage. 3.7 Protection: Solar charge controller (SCC) should have: + Reverse protection, = PV short circuit Protection , PV over Current Protection and PV over voltage Protection. = PV and Battery reverse polarity Protection. = Battery over charging and over discharging protection. * Load short circuit protection and overloads protection. 3.8 Programmable Functions (Alarms /shut off): Solar Charge Controller unit shall have programmable Functions that allow field setting charge modes and alarm values. i) Battery High Voltage = Battery high voltage Disconnect/ Reconnect adjustable in range [55V ~64V] ii) For Battery Low voltage-: 1 Battery Low voltage Disconnect /reconnect adjustable (40V ~ $3.0V] iii) Load Contr Charge controller should control DC Load = Automatic Low voltage Disconnect/ Recovery adjustable [40 ~54.4 3.9 Communication method: = Solar charge control unit should have suitable Communication ports. | able, = PC Communication cable and PC software and software 3.10 Guarantee: one year minimum against any manufacturing defects 3.11 Attachment: - - Attach Data sheet, user manual and installation Manual. | Page 2-0f 5 | cept een ERE a ee Re rte eS ues ein - The bidder must: a) Be an authorized agent for the manufacturer, b) Have an experience of at least ten (10) years in importing solar charger into the country. ) CIQ Certificate for all industrial products imported from Republic of China. 4) Bidders must submit related industry experience in supplying similar works and goods. ¢) Identify the country of origin. = Yemen Mobile Company has the right to visit the bidder workshop and exhibition shop to make sure the above requirements are met. Important notes Any provided offer without complete technical data for all units and parts will be ignored ~The tenderer should fill the attachments tables of Schedule technical data __—_—_—_— ee Page 3 of 5 Schedule of Technical Data for MPPT Solar Charger rx Z “ ig tous GB Model of MPPT Solar charger — ‘Specify | 2 Manufacturer/Make = Specify 3 Country of Manufacturer — Specify. 4 Technolo; ‘Advance MPPT S__ Battery System Voltage 48V | 6 Groundin; ‘Common positive “A. Operating Temperature i ~ Specify | 727 Storage Temperature |___ Specify ___| “3__ Operation altitude (above sea level) Up to 30 ‘4 Humidity: operating Specify 4 Coolin; Fully heat sink 2 PV terminals Cross section mm | ___ Specify = 3. Battery ls Cross sect mm? Specify 4 Load terminals Cross section _ mm Specify | = 'S__| Dimension : L¥H*W mm Specify sisscuanmesaeat a 6 Weight ks Specify Oo S14 Installation mode 2 Mounting Type 3 IP PV Input Voltage Range VDC ‘Max. PV input voltage (VOC) 3 1 2 3 Start the charge voltage point Rated PV Power Be support battery type. osdad| GEL AGM Ulan 2 Charger Stages Specify 3 Output Voltage Range VDC _[__-40V to -60VDC 4 Output Voltage (default) VDC 53.5VDC, 3 ‘Charging rated current Load voltage Battery voltage(48V) Load rated current Rea AEE LCD Display Specify Communication Spegify ‘Synchronous Gable 1 2 3__ Synchronous mode (parallel mode) 4 3 ‘Software cable Original Copy of sofware its Page 4 of 5 el “=, Array Parameters (Volt, Amp, Ah) Battery Parameters (Volt, Amp, Ah) | Load Parameters (Volt, Amp, Ah) Accumulated amp-hours, watt-hour Float Voltage Boost Voltage Boost Time Boost interval Equalize Voltage Equalize Duration Equalize Period Battery high voltage alarm Battery high Voltage disconnect auto Battery high voltage reconnect auto Low battery voltage(LVB) alarm Low battery voltage disconnect auto Low battery voltage Reconnect auto Load low voltage alarm Load low voltage disconnect auto Load low voltage recover auto Charging status: Charge stage: Battery fully charged Reverse protection Over temperature protection Lighting and transient surge Protection PV short circuit Protection PV over Current Protection PV over voltage Protection PV reverse polarity Protection Battery reverse polarity Protection Battery over charging protection Battery over discharging protection Load short circuit protection Load overloads protection Data sheet of MPPT Solar Charger ‘User and installation manual MPPT Vde Vde hours months Vde months hours 48-60V, Specify Specify Specify Specify Specify Specify Specify Specify Specify Specify Specify Specify Specify Specify Specify Charge On/Charge Stop To be mentioned To be mentioned Specify Specify Specify Specify Specify Specify Specify Specify Specify Specify 1. Introduction These specifications cover the technical specifications for an advance MPPT Photovoltaic Charge Controller with the operating voltage of (48VDC) Positive ground to use for telecom load. 2.1 Operating Environment Conditions i) Ambient Temperature: =10°C to + 55°C. ii) Relative Humidity: up to 90%. iii) Altitude: up to 3000metres above mean see level. 2. Technical Specifications for Solar Charge Control Unit (SCCU) and Load Control: 3.1 General The solar charge controller shall be designed for heavy duty use and shall be provided to contral the charging of batteries from photovoltaic panels and to control the load 3.2 Features ‘The Solar Charge Controller (SCC) shall meet the following features | = Advanced MPPT Technology with high Efficiency. = LCD Display: Multifunction digital LCD with keypad displays system data and status = Control and management: Charge regulation, battery management parameters and load control parameters are fully adjustable and programmable to meet different requirements. = Battery Compatibility: Sealed, Gel, flooded , lithium ion and. user. * Multi-stage charging optimizes battery performance, MPT efficiency > 98%, Peak conversion efficiency 98%. * Installation: Suitable for Indoor installation and easily install in parallel connection 3.3 Battery system Voltage: (48V D.C) Positive ground. 3.4 Charge controller Rating Output: Each Solar Charger controller capacity shall meet the following: # Charging current is (60 ~ 80)Amp DC at 40°C | * Discharge current (Rated Load Current) is (60 ~80) Amp DC 3.5 PV input Voltage: = Max. PV input voltage(VOC) : 150VDC at least. - Start the charge voltage point: Battery Voltage + 3V - Overvoltage protection point: 165VDC at least. 3.6 Digital (display Led indicators): 1) Digital Display + = Solar charge controller should have Multifunction liquid crystal display (LCD) with keypad for Configuration and system monitoring. 2) Measure SCC which indicates at least the following parameters * Battery Display: Battery Voltage, Battery Charging Current and Battery Ah. = PV Solar Display: PV panel Voltage, and current. | * Load Display: Load voltage and current 3) LED Indicators The following Visible LED indications shall be provided: s [a : Page 1 of 5 ern * Charging status: Charge On/Charge Stop * Battery fully charged / Battery low voltage 3.7 Protection: Solar charge controller (SCC) should have: * Reverse protection, * PV short circuit Protection, PV over Curent Protection and PV over voltage Protection, * PV and Battery reverse polarity Protection * Battery over charging and over discharging protection * Load short cituit protection and overloads protection, 3.8 Programmable Functions (Alarms (shut off): *Solar Charge Controller unit shall have Programmable Functions that allow field setting charge modes and alarm yalues i) Battery High Voltages-: | "Batter ige Disconnect/ Reconnect adjustable in range [5SV ~64V] ii) For Battery Low voltage-: 1 Battery Low voltage Disconnect ‘reconnect adjustable [40V ~ 53.0), iii) Load Control-: | Charge controller should control DC Load. * Automatic Low voltage Disconnect! Recovery adjustable [40 ~$4.4] 3.9 Communication method: ~ Solar charge control unit should have suitable C ‘ommunication ports, | PC Covmmanteation cable and PU software and software cable. 3.10 Guarantee: one-year minimum against any manufacturing defects 3.11 Attachment: - ~ Attach Data sheet, user manual and installation Manual Part-I :Technical Speci ions For ir Charge Controller Power ‘stem | 2022 Part-1; Technical Specifications For Solar Charge Controller J. Introduction T= Specifications cover the technical and mechanical requirements for one groups of solar charger systems. Scope of Supply | No. | Brief Descriptions ae Units 7 Quantity ip ] 5 i Solar Charge Controller (MPPT) as per Specifications ] Nos. 120 Tender NO: ( 1. Introduction These specifications cover the technical specifications for an advance MPPT Photovoltaic Charge Controller with the operating voltage of (48VDC) Positive ground to use for telecom load 2.1 Operating Environment Conditions i) Ambient Temperatur. -10°C to + 55°C ) Relative Humidity: up to 90%. iii) Altitude: up to 3000metres above mean see level, 2. Technical Specifications for Solar Charge Control Unit (SCCU) and Load Control: 3.1 General The solar charge controller shall be designed for heavy duty use and shall be provided to control the charging of batteries from photovoltaic panels and to control the load. 3.2 Features The Solar Charge Controller (SCC) shall meet the follow ‘ing features * Advanced MPPT Technology with high Efficiency * LCD Display: Multifunction digital LCD with keypad displays system data and status, * Control and management: Charge regulation, battery management parameters and load control parameters are fully adjustable and programmable to meet different requirements, * Battery Compatdilty; Sealed, Gel, flooded , lithium ion and user. * Mult-stage charging optimizes battery performance, MPPT efficiency > 98%, Peak conversion efficiency 98%. * Installation: Suitable for Indoor installation and easily install in paral connection. 3.3 Battery system Voltage: (48V D.C) Positive ground 3.4 Charge controller Rating Output: Each Solar Charger controller capacity shall meet the following * Charging current is (60 ~ 80)Amp DC at 40°C. * Discharge current (Rated Load Current) is (60 ~80) Amp DC 3.5 PV input Voltage: | Max. PY input vouage VOC) : IS0VDC at least. ~ Start the charge voltage point: Battery Voltage + 3V Overvoltage protection point: 165VDC at least 3.6 Digital (display Led indicators): 1) Digital Display : ~ Solar charge controller should have Multifunction liquid crystal display (LCD) with keypad for __| Configuration and system monitoring. 2) Measur SCC which indicates at least the following parameters. * Battery Display: Battery Voltage, Battery Charging Current and Batiery Ah and current. |.) * PV Solar Display: PV panel Voltage, * Load Display: Load voltage and current | 3) LED Indicators \ : le LED indications shall be pro’ The followi * Charging status: Charge On/Charge Stop * Battery fully charged / Battery low voltage 3.7 Protection: Solat charge controller (SCC) should have: * Reverse protection. * PV short circuit Protection , PV over Current Protection and PV over voltage Protection. * PV and Battery reverse polarity Protection. * Battery over charging and over discharging protection ‘= Load short circuit protection and overloads protection 3.8 Programmable Functions (Alarms /shut off): *Solar Charge Controller unit shall have programmable Functions that allow field setting charge modes and alarm values. i) Battery High Voltages~ = Battery high voltage Disconnect’ Reconnect adjustable in range [5SV ~ 64V]. ) For Battery Low voltage | Battery Low voltage Disconnect ‘reconnect adjustable [40V ~ 53.0V] i) Load Control-: Charge controller should control DC Load. * Automatic Low voltage Disconnect/ Recovery adjustable [40 ~54.4] 3.9 Communication method: ge control unit should have suitable Communication ports - Solar c PC Communivation cabte and PU sottware and software cable. | 3.10 Guarantee: one-year minimum against any manufacturing defects 3.11 Attachment: - + Attach Data sheet, user manual and installation Manual. Page2-of 5 a ‘eclinical Specifications of MPPT Solar ¢ eras ~ The bidder must 4) Be an authorized agent for the manufacturer, b) Have an experience of at Teast ten (10) years in ‘importing solar charger into the country. ©) C1Q Certificate forall industrial products imported from Republic of China, 4) Bidders must submit related industry experience in supplying similar works and goods ©) Identify the country of origin ~ Yemen Mobile Company has the right to visit the bidder Workshop and exhibition shop to make sure the above requirements ate met. Important notes ~ Any provided offer without complete technical data for all units and parts will be ignored. | The tenderer should fill the at chments tables of Schedule technical data |r "| Schedule of Technical Data for MPPT Solar Charger — Tie ate AS een ie aT a TH Model of MM Solar charger = Specify 2° Manufacturer/Make = Specify 3 County of Manufacturer = Speci 47 Technology Advance MPPT 5 Battery System Volage | a8 61 Groundin T Common postive 1 Operating Temperature CT specity See 2 Storage Temperature [_G | Specify ae x lade (above see evel) | “m | Up to 3000 = 4 ating RET Specify Cooling 7 Fully heatsink [ 2 PV terminals Cross section [am Specify 3. Battery terminals Cy Fae Specify 4” Load terminals Cress section ame Specif F 5.7) Dimension : LeH*W mm_| Specify i oe 65) Weight y Speci S27 Installation mode 2% Mounting Type: 30 P 1 PV Input Voltage Range VDC 27 Max. PV input voltage (VOC) Voc 3.1 Start the charge voltage point Voe 4 Rated PV Power Wait al BM sinpoe tery type Hoodd, GEL, AGM, Leto 2 Charger Sages Specify 3 Output Voltage Range VDC_[—-40V to -@OVDC 4 Output Voltage (default vpe SVDC | [os aa current “Amp a0 = 177 Load voltage V_| Battery voliget8V) | [S22 Load rated curent Amp | [3 Tow vottage | [1 cD Display : ~ Specif [=2= Communication Specify 3.7 Synchronous mode (parallel mode) 422 Synchronous Bale | [5 Sonware cable Original Copy oTsafinare rnceded Page 4 0f5 ——} SS ~ Amay Parameters (Volt, Amp, Ah) Battery Parameters (Volt, Amp, Ah) Load Parameters (Volt, Amp, Ah) Accumulated amp-hours, watt-hour Float Voltage Vde 48 —60V Boost Voltage vac | Specify | Boost Time | hours Specify | Boost interval months Specify | Equalize Voltage Vde Specify | Equalize Duration | months Specify | Equalize Period hours Specify | Battery high voltage alarm — Specify | Battery high Voltage disconnect auto _ Specify 10 Battery high voltage reconnect auto = Specity = Specify 11 Low battery voltage(LVB) alarm A2~ Low battery voltage disconnect auto 13__Low battery voltage Reconnect auto 14° Load low voltage alarm 15. Load low voltage disconnect auto 16 "Load low voltage recover auto Charge On/Charge 1 Charging status: | pk 2 Charge stage: To be mentioned 3 Battery fully charged | To be mentioned Reverse protection Specify | Over temperature protection Specify Lighting and transient surge Protection Specify PV short circuit Protection Specify | 1 2 3 4 7 5. PV over Current Protection y 6 PVover voltage Protection 7 PV reverse polarity Protection 8 9 10 u 12 Specify Speci Battery reverse polarity Protection Battery over charging protection Battery over discharging protection Specify | Load shor circuit protection Specify Load overloads protection | Specify ©; Data sheet of MPPT Solar Charger I User and installation manual MPPT. Warranty period al Specifications For Solar Charge Controller 1 Introduction hese specifications cover the technical and mechanical requirements for one groups of solar charger systems. Scope of Supply Brief Descriptions Quantity ] Solar Charge Controlier (MPPT) as per Specifications Yemen Mobile — Tender NO:() for supply solar controller power system 1. Introduction These specifications cover the technical specifications for an advance MPPT Photovoltaic Charge Controller with the operating voltage of (48VDC) Positive ground to use for telecom load 2.1 Operating Environment Conditions i) Ambient Temperature: 710°C to + 55°C, ii) Relative Humidity: up to 90%, ii) Altitude: up to 3000metres above mean see level. 2. Technical Specifications for Solar Charge Control Unit (SCCU) and Load Control: 3.1 General The solar charge controller shall be designed for heavy duty use and shall be provided to control the charging of batteries from photovoltaic panels and to control the load. 3.2 Features The Solar Charge Controller (SCC) shall meet the following feature "Advanced MPPT Technology with high Efficiency * ECD Display: Multifunction digital LCD with keypad displays system data and status. * Control and management: Charge regulation, battery management parameters and load Control parameters are fully adjustable and programmable to meet different requirements * Battery Compatibility: Sealed, Gel, flooded , lithium ion and user. * Multi-stage charging optimizes battery performance, MPPT efficiency > 98%, Peak conversion efficiency 98%, * Installation: Suitable for Indoor installation and easily install in parallel connection 3.3 Battery system Voltage: (48V D.C) Positive ground 3.4 Charge controller Rating Output: Each Solar Charger controller capacity shall meet the following: "Charging current is (100 ~ 120)Amp DC at 40°C. * Discharge current (Rated Load Current) is (60 ) Amp DC at 3.5 PV input Voltage: Max. PV input voltage(VOC) : 400VDC at least ~ Start the charge voltage point: less than 100VDC - Overvoltage protection point: SOOVDC at least. I (display Led indicators): ~ Solar charge controller should have Multifunction liquid crystal display (LCD) with keypad for Configuration and system monitoring 2) Measures SCC which indicates at least the following parameters. + Battery Display: Battery Vol ge, Battery Charging Current and Battery/Ah. * PV Solar Display: PV panel Voltage, and current.) . ‘yi! * Load Display: Load voltage and current 3) LED Indicators The following V Page 1 of 5 Group(2): Technical Specifications of MPP TE Solar € * Charging status: Charge On/Charge Stop + Battery fully charged / Battery low voltage. 3.7 Protection: Solar charge controller (SCC) should have: Reverse protection. * PV short circuit Protection , PV over Current Protection and PV over voltage Protection, + PV and Battery reverse polarity Protection. = Battery over charging and over discharging protection. * Load short circuit protection and overloads protection. 8 Programmable Functions (Alarms /shut off): *Solar Charge Controller unit shall have programmable Functions that allow field setting charge modes and alarm values. i) Battery High Voltage: Battery high voltage Disconnect/ Reconnect adjustable in range [55V ~64V] For Battery Low voltage-~ 1 Battery Low voltage Disconnect /reconnect adjustable [40V iii) Load Control-: Charge controller should control DC Load. "Automatic Low voltage Disconnect/ Recovery adjustable [40 ~54.4] 3.9 Communication method: - Solar charge control unit should have suitable Communication ports - PC Communication cable and PC software and software cable, 3.10 Guarantee: one year minimum against any manufacturing defects 3.11 Attachment: - - Attach Data sheet, user manual and installation Manual Page 2 of 5 @) Be an authorized agent for the manufacturer, b) Have an experience of at least ten (10) years in importing solar charger into the country ©) CIQ Certificate for all industrial products imported from Republic of China. 4) Bidders must submit related industry experience in supplying similar works and goods ©) Identify the country of origin. Yemen Mobile Company has the right to visit the bidder workshop and exhibition shop to make sure the above requirements are met. Any provided offer without complete technical data for all units and parts will be ignored. ~ i The tenderer should fill the attachments tabl of Schedule technical data, Page 3 of 5 N aa a. 3 Schedule of Technical Data for MPPT Solar Charger 1] Model of MPPT Solar charger ‘Manufacturer/Make ‘Country of Manufacturer 345 Technolo; 3 2, 4 is ee 2 3 1 2 3 4 3 6 Battery System Volta Groundin; J Operating Temperature _ Operation altitude ab Humidity: operating Coolin; PV terminals Cross sect Battery terminals Cross section Load terminals Cros: Dimension : L*H*W Weight Installation mode ‘Mounting Type: TP. PY Input Voltage Range ‘Max. PV input voliage (VOC) Start the charge voltage point Rated PV Power ‘Support battery type. Charger Stages ‘Output Voltage Range ‘Output Voltage (default) ‘Charging rated current Load voltage Load rated current Low voltage protection LCD Display ‘Communication ‘Synchronous mode (parallel mode) ‘Synchronous Software cable Original Copy of software if needed ove sea level) arf Up to 3000 ‘Advance MPPT 48V. ‘Common positive Specify Specify ‘Specify Fully heat sink VDC VDC. VDC Watt Flooded, GEL, AGM, Li-lon Custom, ‘Specify VDC T-40V to -60VDC VDC 33.5VDC Battery voltage(48V) San ie Specify Specify Specify Page 4 of 5 SS SS Array Param, =f... Battery Parameters (Volt, Amp, Ah) 35> Load Parameters (Volt, ‘Amp, Ah) | 3 Accumulated amp-hours, Wwatt-hour eters (Volt, Amp, Ah) S12 Float Voltage Vde © Boost Voltage Vae Specify | 3B Boost Time | hours | Specify | 4° Boost interval ‘months | Specify 5. Equalize Voltage Vde Specify | Bo equalize Duration months Specify F Equalize Period hours Specify # Battery high voltage alarm (oe. Specify | &... Batery high Voluge disconnect auto |—| Specify | 0... Battery high voltage reconnect au — Specify | A Low battery voltage(LVB) alarm al Specify | M2 Low battery voltage disconnect auto —| Specify | 13 Low battery Voltage Reconnect auto —_| Specify 14. Load low voitage alarm _— Specify fe Load low voltage disconnect aute — Specify Tecover auto —— | Specify | Load low volta, | Charge On/t | Stop | Tobe mentioned To be mentioned Charge Charging status: “2 Charge stage 3 Battery fully charg 1" Reverse protection 2 Specify 2 Over temperature protection Specify {Lighting and transient surge Protection Specify | 4 PV short circuit Protection Specify | 3. PV over Current Protection Specify | § PV over voltage Protection Specify 7 PV reverse polarity Protection Specify | £. . Battery reverse polarity Protection Specify | 9 Battery over charging Protection Specify 10 Battery over discharging protection Specify | | P. Load shon circuit protection Specify 12 Load overloads protection ata sheet of MPT Solar Charger User and installation manual MPPT Warranty period nn Page 5 of 5

You might also like