You are on page 1of 25
RIYADH CABLES GROUP COMPANY aly dts ds pane As To, ATCO POWER COMPANY QUOTATION ; MR20-0557 Post Box it YEMEN Quoted Dated : 15/12/2020 Valid Upto : 30/12/2020 PROJECT NAME : NATIONAL DAIRY & FOOD COMPANY PROJECT ATTEN : Engr. Haikal Altwaiti FROM : Engr. Maen Salahiya Our ref : MR20-0557 Pages No 1 of 196 'SLNO DESCRIPTION ‘SIZE | _QIY/KM | U:PRICE SAR/KM | T-PRICE/SAR | V.F (CU) | V.F (AL) 1_[_cufxre/swa/pvc-aky | 4xza0__ | 0.500 305,237.40 | 152,618.70 | 3713 [ 2 ‘CU/XLPE/PVC-1kv @xza0__ [0.500 290,959.25 | 145,479.63 | 31.713 | - '3_| CU/XLPE/SWA/PVC-tkv | 4x185__| 0.500 232,997.30 | 116,498.65 | 24123 | - 4 ‘CU/XLPE/PVC-tkv x85; (0.500 221,545.85 | 110,772.93 | 24.123 | — S| CU/xLPE/SWA/PVC-tkv | 4x150__| 0.500 187,318.45 93,659.23 | 19.269 | 6 ‘CU/XLPE/PVG-Lkv axas0__ [0.500 178,309.00 89,154.50 | 19.269 | _- 7_| CU/xLPE/swa/pvc-akw | 4x120 (0.500 153,163.30 76,581.65 | 15.556 | _~ a ‘CU/XLPE/PVC-1kv 4x20 (0.500 144,552.15 72,276.08 | 15.556 | _~ ‘9 | CU/xLPE/SWA/PVC-Ikv [4x95 (0.500 123,011.10 61,505.55 | 12.400 | - 10 ‘CU/KLPE/PVC-Lkv x95; (0.500 116,611.80 58,305.90__| 12.400 | 11_| CU/XLPE/SWA/PVC-tky [4x70 (0.500 90,712.15, 45,356.08 | 6.943 | __— 12 CU/XLPE/PVC-Lkv 4x70 (0.500 84,625.75, 42,312.88 _|_8.943 | __— 13_| CU/XLPE/SWA/PVC-tkv | 4x50 (0.500 62,858.25 31,429.13 | 6117 | 14 CU/XLPE/PVC-Ikv 4x50 0.500 58,949.40 29,474.70_| 6117 | 15 | CU/XLPE/SWA/PVC-Ikv | 4x35 0.500) 46,745.00, 23,372.50 | 4.056 | 16 ‘CU/XLPE/PVC-1kv axa5) 0.500) 43,543.85 21,771.93] 4.464 | 17_| CU/XLPE/SWA/PVC-tkv | 4x25 (0.500 36,325.65 18,162.83 | 3.262 | 18 ‘CU/XLPE/PVC-1kv 4x25) (0.500 33,263.90 16,631.95 | 3.262 | 19 | CU/xLPE/SWA/PVC-Ikv [4x16 (0.500 24,677.15 12,338.58 | 2.059 | 20 ‘CU/XLPE/PVC-1kv axi6 (0.500 22,198.10 11,099.05 | 2.059 | _- 21_| CU/KLPE/SWA/PVC-ikv | 4x10 (0.500 17,043.20 3521.60 | 1.278 | _- 22, ‘CU/XLPE/PVC-tkv ‘xi0 (0.500 14,843.00 7,421.50 | 1278 | 23__|_CU/XLPE/SWA/PVC-1kv 4x6 (0.500 11,653.35 5,826.68 | 0.761 | _— 24 ‘CU/XLPE/PVC-Lkv x6) (0.500 10,018.50 5,009.25 | 0.761 |__- 25 _|_CU/XLPE/SWA/PVC-1kv (0.500 8,991.40 4,495.70 | 0510 | _- 26 CU/XLPE/PVC-1kv axa (0.500 7,353.75, 3,676.88 | oso | - 27_|_CU/XLPE/SWA/PVC-1ky | 4x25 0.500 6,404.15, 3,202.08 | 0.317 |__- 28 CU/XLPE/PVC-Akv O25) (0.500 5,104.35, 2,552.18 [0.317 |__~ 29 | CU/xLPE/SWA/PVC-1kv_|3x240+120 | 0.500 269,869.70__| 134,934.85 | 27.674 | 30, ‘CU/XLPE/PVC-tkv | 3x240120 | 0.500 256,080.20 | 428,040.10 | 27.674 | 31_| CU/XLPE/SWA/PVC-1kv | 3x185+95 | 0.500 207,225.95 | 103,612.98 | 21.181 | _- 32, ‘CU/XLPE/PVC-Akv 3xi85+95 | 0.500 196,103.45 98,051.73 | 21181 | '33__| CU/XLPE/SWA/PVC-Ikw | 3x150¥95 | 0.500 172,147.85 36,073.93 | 17.540 | ~ 34 ‘CU/XLPE/PVC-Akv 3x150+95 | 0.500 163,395.15 31,697.58 | 17.540 | ~ UNIFIED TEL : 920000772. FAX +96611 2651423 — 2650942 TOLL FREE 800 122 9999. E-mail: rege@riyadh-cables.com ~local_sales@riyadh-cables.com . P.O.Box :26862 Riyadh11496 RIYADH CABLES GROUP COMPANY oat ots dis gana ds, ds 35_[_CU/XLPE/SWA/PVC-ikw | 3xi20+70 [0.500 136,920.45 66,460.23 | 13892 | _— 36, ‘CU/XLPE/PVC-Akw 3x120+70_ | 0.500 129,840.45 64,920.23 | 13.892 |__— '37_|_CU/XLPE/SWA/PVC-tkw | 3x95+50 | 0.500 109,244. 54,622.23 | 10.833 | — 38, ‘CU/LPE/PVC-Ikv 3x95+50 | 0.500 103,131.00 52,565.50__| 10833 | 39_|_CU/xLPE/swa/PvC-ikw | 3x70+35 | 0.500 80,971.15 40,485.58 | 7.845 | _- 40. CU/XLPE/PVC-Iky '3x70+35_| 0.500 75,104.95 37,552.48 | 7.846 | ~ “41_|_CU/xiPE/SWA/PVC-1kv | 3x50+25 | 0.500 56,494.00, 28,247.00_| 5.403 | __— a2, (CU/XLPE/PVC-Ikv 3x50+25 | 0.500 52,728.45, 26,364.23 | 5.403 | - 43__| CU/XLPE/SWA/PVC-tkv | 3x35+16 | 0.500 41,348.50 20,674.25 | 3.863_|__— aa, CU/XLPE/PVC-Iky 3x35+16 | 0.500 38,141.35, 19,070.68 | 3.863 | 45__|_CU/XLPE/SWA/PVC-1kv | 3x25+16 | 0.500 33,520.00 16,760.00_| 2961 | - 46. ‘CU/XLPE/PVC-Ikv 3x25416 | 0.500 30,525.45, 15,262.73 | 2.961 | - 47_|_CU/xLPE/SWA/PVC-tkv | 3x16+10 | 0.500 22,511.56 11,255.78 1.864_| - 48 ‘CU/KLPE/PVC-Ikw 3x16+10_| 0.500 20,476.70, 10,238.35 | 1.868 | - ‘49 | _CU/XLPE/SWA/PVC-tkv | 3x240 0.500 234,856.00 __| 117,428.00 | 23741 | 50, ‘CU/XLPE/PVC-Ihe 3x240 (0.500 220,915.90 | 110,457.95 | 23.741 | _— 51_| _CU/XLPE/SWA/PVC-Ikv | 3x185 (0.500 179,344.25 99,672.13 | 18.018 |__— 52 CU/XLPE/PVC-Iky 3x45 0.500) 169,857.25 84,928.63 | 18.018 | - 53_| CU/XLPE/SWA/PVC-tkv | 3x150 0.500 145,871.50 72,935.75__| 14.362 |__- 54 CU/XLPE/PVC-Iky 3x150, 0.500. 135,564.35 67,782.18 | 16392 |_— 55 | CU/XLPE/SWA/PVC-kv | 3x120 0.500) 117,188.50 58,594.25 | 11.667 |__- 56 ‘CU/XLPE/PVC-Ikv 3x120__ | _0.500 110,128.60 55,064.30 | 11.667 |__- 's7_| Cupure/swa/pvctky | 3x95 (0.500 (94,408.50 47,204.25 | 9.190 |_— 38. ‘CU/XLPE/PVC-Lky 3x95, (0.500 (88,227.30 44,113.65 | 9.190 | - 59_| cu/xire/swa/pve-tky [3x70 (0.500 69,404.25 34,702.13 | 6.596 |__- 60. ‘CU/XLPE/PVC-Ikv 3x70 (0.500 63,994.60 31,997.30 | 6.596 |__- 61_|_CU/XLPE/SWA/PVC-tkv | 3x50 (0.500 48,588.80 24,294.40 | 4.578 | _~ 62. ‘CU/XLPE/PVC-1kw 3x50 (0.500 44,823.60) 22,411.80 | 47 | _~ 63 | CU/xLPE/SWA/PVC-Ikv [3x35 (0.500 36,918.50, 13,459.25 | 3.366 | 64 CU/XLPE/PVC-Ile 3x35 (0.500 33,748.00 16,874.00 | 3.366 | - 65_|_CU/XLPE/SWA/PVC-1ky | 3x25 0.500 28,312.15 14,156.08_| 2.426 |_- 66, CU/XLPE/PVC-Ikw 3x25 (0.500 25,371.95 22,685.98 | 2426 | __- 67_| CU/XLPE/SWA/PVC-tkv | 3x16 (0.500 18,936.95 9,468.48 | 1.532 | - 68 ‘CU/XLPE/PVC-Lhey 3x16 0.500 17,109.75 3554.88 | 1532 | — 69_| CU/XLPE/SWA/PVC-Ikv | 3x10 (0.500 13,594.95 6,797.48 | 0.958 | _- 70 ‘CU/XLPE/PVC-Ikv 3x10 (0.500 111,786.00 5,893.00 | 0.958 | - 71_| CU/xLPE/SWA/PVC-ikv 3x6 (0.500 9,192.35, 4596.18 | 0570 | - 72 ‘CU/XLPE/PVC-Lkv 3x6 0.500 7,887.25, 3,983.63 | 0570 | - 73_|-CU/XLPE/SWA/PVC-Ikv 3x4 (0.500 7,206.75 3,603.38 | 0.382 | - 74 ‘CU/XLPE/PVC-Lkv 3x4 (0.500 5,838.45, 2,919.23 | 0.382 | 75_| CU/XLPE/SWA/PVC-ikv | 3x2.5 (0.500 5,392.35 2,696.18 | 0238 | 76 ‘CU/XLPE/PVC-Lkv B25, (0.500 4,176.00 2,088.00 | 0.238 | 7_|_CU/xUPE/AWA/PvC-tkv | 1x630 (0.500 201,154.15 | 100,577.08 | 21.086 | 1.872 78 CU/XLPE/PVC-1kv 14630 (0.500 194,442.75 97,221.38 | 21.086 | - 79 | CU/xLPE/AWA/PVC-tkv | 1x240 (0.500 7,433.10 38,716.55_| 7.913 | 0.963 20, CU/XLPE/PVC-Lley 14240 (0.500 73,443.35, 36,721.68 | 7.913 | - g1_| CU/XLPE/AWA/PVC-tkv | 1x185 (0.500 60,459.75, 30,229.88 | 6.008 _| 0.856 82, CU/XLPE/PVC-Iky axaa5 (0.500 56,351.20 28,175.60 | 6.008 |__- 33__| CU/xUPE/AWA/PVC-ikv | 1x15 (0.500 48,838.95 24,419.48 | 4.79 | 0.792 UNIFIED TEL; 920000772. FAX +9661 2651423 ~ 2650942 TOLL FREE 800 122 9999, E-mail: rege@riyadh-cables.com -local_sales@riyadh-cables.com . P.O.Box :26862 Riyadh11496 RIYADH CABLES GROUP COMPANY ‘TERMS & CONDITIONS OF SALE : Prices : Net Ex Factory Riyadh. Alll prices are variable & subject to final adjustment according to the Single cu gal) os 4s pea As a] _cuparefevCaiw | —aas0 | 0500_[ a5 a0030 | maesz05 | amo | ~ 85 CU/XLPE/AWA/PVC-1kv 1420, 0.500 40,696.85 20,348.43, 3.881 0.706 86 ‘CU/XLPE/PVC-1kv 14120 0.500 36,878.35, 18,439.18 3.881 - 87 ‘CU/XLPE/PVC-1kv 1x95 0.500 29,561.25 14,780.63, 3.083 - 83 CU/XLPE/PVC-1kv 1x70 1,000 21,713.15 21,713.15 2.220 89 CU/XLPE/PVC-1kv 1x50. 1.000. 15,411.00 15,411.00 1.530 = 90 ‘CU/XLPE/PVC-1kv 1x35, 1.000 11,566.15 11,566.15, 1.125 : 91_[cupure/evCake ax25 | 1.000 | 8486.75 3486.75 | 0.406 | 22 _| cU/MPE/PVC-1kv axa6_| 1.000 | 5,683.95 5,643.95 [0509 | 93 CU/XLPE/PVC-1kv 1x10 1,000 3,844.85 3,844.85, 0.319 : 94 CU/XLPE/PVC-Akv_ 1x6 1.000 2,548.65 2,548.65 0.190. = 95. CU/XLPE/PVC-Akv_ x4 1,000 1,912.40 1,912.40 0.127, = 96 ‘CU/XLPE/PVC-1kv 25 1.000 1,285.45 1,285.45 0.079 : TOTAL SAR 3,846,415.28 LIME cash settlement price (LME) of the next working day from the date of receiving of order using the international adjustment formula as follows : Metal, ‘Two Metals (CU+AL) NSP = ow AL ).P. +/-M1+/-M2 : ML=V.F. (UME2 x £2/3.75 -7800) 2M V.F, (LIME2 x E2/3.75 -2100) ISP =O.P. +/- V.F (LME2 x E2/3.75 - 7800) ‘SPECIAL NOTE : OUR ABOVE QUOTED PRICES ARE EXCLUDING VAT RATE OUR VAT REGISTRATION NO. IS 300050432610003 4g B52) ppl eel 95) Oly" dL dal Band Jal pb odie! paul! jo56 : dale Aba dte 300050432610003” Packing : As per our standard packing length with +/-5% tolerance. Payment 10% down payment balance by L/C at sight. Delivery : To be mutually agreed at the time of order confirmation. Specification : Quoted items shall be as per attached Technical Data. ‘UNIFIED TEL : 920000772. FAX +96611 2651423 — 2650942 TOLL FREE 800 122 9999. E-mail rege@riyadh-cables.com ~ local_sales@riyadh-cables.com . P.O.Box :26862 Riyadh11496 RIYADH CABLES GROUP COMPANY al) Gs 4s gape dS Min.Qty : Small Quantities shall be discussed at the time of order negotiation. Note : Total offer price is for whole mentioned items all together, in case of deleting and or selecting specific item, revised offer will be applied. Please always mention our ref.No. in all correspondence. with regards, ENGR. MAEN SALAHIYA UNIFIED TEL : 920000772. FAX +9661 2651423 - 2650942 TOLL FREE 800 122 9999. E-mail: rege@riyadh-cables.com -local_sales@riyadh-cables.com . P.O.Box :26862 Riyadh11496 RIYADH CABLES GROUP COMPANY P.O. Box 26862, Riyadh 11496 Saudi Arabia DIMENSIONAL DATA FOR 4x240mm? CU/XLPE/SWA/PVC 1 kV DESCRIPTION UNIT DETAILS [Reference Standard ai —_ TBC 60502-1 |Rated voltage of cable Uo/U KV 0.6/1 [Number of cores (Ph) No. 4 |Nominal conductor cross-sectional area (Ph) mm? 240 |Shape of conductors (Ph) Sectoral Compacted (Class 2) [Conductor material Copper | [Number of strands (Ph) 61 | [Approximate diameter of conductor (Ph) 17.6 [Insulation material XLPE |Nominal thickness of XLPE insulation(Ph) aa |4pproximate diameter over insulation(Ph) a 21 [Approximate diameter over Laid up cores 48.4 |Material of inner sheath PVC [Nominal thickness of PVC inner sheath mm. 16 [Approximate diameter over inner sheath mm) 52.1 [Material of the metallic armour Round Galvanized Steel Wires _ |Nominal armour wire diameter No. xmm 59x25 [Approximate diameter over armour mm S71 [Material of outer sheath Extruded PVC-ST2 Nominal thickness of PVC outer sheath mm 3.0 lApproximate overall diameter of cable mm) 64 Approximate weight of complete cable kg/km 12850 [Colour of insulation RED, YELLOW, BLUE, BLACK [Colour of outer sheath BLACK Phi Phase Printed by: Eng. EYAD Reviewed By: §.Eng, A.Darweesh 13-Sep-2018 FORM# TE/A/F/07 Issue no.00 08.12.1998, Page 1 of 2 RIYADH CABLES GROUP COMPANY P.O, Box 26862, Riyadh 11496 Saudi Arabia CABLE'S PARAMETERS FOR 4x240mm? CU/XLPE/SWA/PVC 1 kV DESCRIPTION UNIT DETAILS Rated voltage of cable Vor Bae eee Oot Highest operating voltage Umax kV 12 Phase conductor DC resistance at 20°C Qik 0.0754 |Phase conductor AC resistance at 90°C. km 0.1004 S-phase inductance mam 0.224 [S-phase reactance ai 60 Hz | fer 0.084 [3-phase impedance at 90°C a ‘lk’ 0.131 3-phase capacitance pF 0.16 | Minimum insulation resistance at 20°C. MQ.km 285 [Minimum bending radius (during installation) mm 7168 [Maximum pulling tension through conductor kN 48 IMax. permissible short circuit current through Phase [Conductor for 1 second ee oot Max. permissible continuous conductor temp. °C 90. [Max. permissible short circuit conductor temp. °C 250 S-phase voltage drop factor ViAlkm 0.226 [Continuous current rating: (for Phase conductor) Single circuit in ground: ‘Amps 323 - Soil thermal resistivity 2 °C/W, - Soi? temperature 40°C |- Direct burial at 700 mm depth | Free air & shaded area at 55 °C ambient temp, ‘Amp: 381 Printed by: Eng. EYAD Reviewed By: S.Eng. A.Darwecsh Approved by Ee 13-Sep2018 ISN ‘TECHNICALDEPARTMENT | ee FORM# TE/A/F/07 Issue n0.00 08.12.1998 Page 2 of 2 RIYADH CABLES GROUP COMPANY P.O. Box 26862, Riyadh 11496 Saudi Arabia DIMENSIONAL DATA FOR 4x185mm? CU/XLPE/SWA/PVC 1 kV DESCRIPTION UNIT DETAILS [Reference Standard Eset TEC 60502-1 |Rated voltage of cable Uo/U_ kV 0.6/1 |Number of cores (Ph) No. 4 [Nominal conductor cross-sectional area (PI) mm? 185 |Shape of conductors (Ph) Sectoral Compacted (Class 2) [Conductor material ia Copper [Number of strands (Ph) No. 37 | Approximate diameter of conductor (Ph) mm 15.1 [insulation material XLPE | Nominal thickness of XLPE insulation(Ph) mm 16 |4pproximate diameter over insulation(Ph) mm 18.3 |Approximate diameter over Laid up cores mm. Bl |Material of inner sheath PVC |Nominal thickness of PVC inner sheath mm 14 [Approximate diameter over inner sheath ‘mm| 464 [Material of the metallic armour Round Galvanized Steel Wires |Nominal armour wire diameter No. x mm. 52x25 |4pproximate diameter over armour mm ec snea |Material of outer sheath Extruded PVC-ST2 [Nominal thickness of PVC outer sheath mam 28 Ldpproximate overall diameter of cable mm 37 L4pproximate weight of complete cable a kg/km 10210 [Colour of insulation RED, YELLOW, BLUE, BLACK [Colour of outer sheath _BLACK Ph: Phase Printed by: Eng. EYAD 13-Sep-2018 Reviewed By: S.Eng. A.Darweesh FORM# TE/A/F/07 Issue no.00 08.12.1998, Page 1 of 2 RIYADH CABLES GROUP COMPANY P.O. Box 26862, Riyadh 11496 Saudi Arabia CABLE'S PARAMETERS FOR 4x 185mm? CU/XLPE/SWA/PVC 1 kV DESCRIPTION UNIT DETAILS [Rated voltage of cable Uo/U W ow [Highest operating voliage Umax kv 12 Phase conductor DC resistance at 20°C ‘Qik 0.0991 [Phase conductor AC resistance at 90°C Qik 0.1296 [S-phase inductance mH/km 0.227 |3-phase reactance at 60 Hz aukm 0.086 [3-phase impedance at 90°C Qik. 0.156 3-phase capacitance uEvkm: 0.157 [Minimum insulation resistance at 20°C MQ.km 310 [Minimum bending radius (during installation) ‘mm 684 Maximum pulling tension through conductor EN 37 IMax. permissible short circuit current through Phase [Conductor for | second ie oat IMax. permissible continuous conductor temp. °C 90 [Max. permissible short circuit conductor temp. °C 250 3-phase voltage drop factor ViAlkm 0.269 [Continuous current rating: (for Phase conductor) \Single circuit in ground: Amps 283 |- Soil thermal resistivity 2 °C, - Soit temperature 40 °C | Direct burial at 700 mm depth |- Free air & shaded area at 55 °C ambient temp. Amps 326 Printed by: Eng. EVAD Reviewed By: S.Eng. A.Darweesh 13-Sep-2018 FORM# TE/A/F/07 Issue n0.00 08.12.1998 Page 2 of 2 RIYADH CABLES GROUP COMPANY P.O. Box 26862, Riyadh 11496 Saudi Arabia DIMENSIONAL DATA FOR 4150mm? CU/XLPE/SWA/PVC 1 kV DESCRIPTION UNIT DETAILS [Reference Standard TEC 60502-1 [Rated voltage of cable UolU Vv 0.6/1 [Number of cores (Ph) No. 4 [Nominal conductor cross-sectional area (Pi) mm? 150 Shape of conductors (Ph) Sectoral Compacted (Class 2) (Conductor material | — Copper [Number of strands (Ph) No. 37 L4pproximate diameter of conductor (Ph) ‘mm 13.8 linsutation material XLPE |Nominal thickness of XLPE insulation(Ph) mm 14 |4pproximate diameter over insulation(Ph) mm 16.6 [Approximate diameter over Laid up cores mm 38.6 |Material of inner sheath PVC [Nominal thickness of PVC inner sheath mam 14 [Approximate diameter over inner sheath mm 419 IMaterial of the metallic armour Round Galvanized Steel Wires |Nominal armour wire diameter No. x mm, 47x25 Approximate diameter over armour mm 46.9 [Material of outer sheath Extruded PVC-ST2 [Nominal thickness of PVC outer sheath mm 26 [Approximate overall diameter of cable mm 53 [dpproximate weight of complete cable kgkm 8480 (Colour of insutation RED, YELLOW, BLUE, BLACK [Colour of outer sheath | Ph: Phase Printed by: Eng. EYAD Reviewed By: .Eng. A.Darweesh 13-Sep-2018 FORM# TE/A/F/07 Issue no.00 08.12.1998 Page 1 of 2 RIYADH CABLES GROUP COMPANY P.O. Box 26862, Riyadh 11496 Saudi Arabia CABLE'S PARAMETERS FOR 4x150mm? CU/XLPE/SWA/PVE 1 kV DESCRIPTION UNIT DETAILS lRated voltage of cable Uo/T kV oor [Highest operating voltage Umax kv, 12 [Phase conductor DC resistance at 20°C ‘Qukm 0.1240 [Phase conductor AC resistance at 90°C Qk. 0.1607 [S-phase inductance mH/km, 0.226 |3-phase reactance at 60 Hz ‘Qik 0.085 |3-phase impedance at 90°C Qik. 0.182 3-phase capacitance pF/km 0.158 [Minimum insulation resistance at 20°C MQ.km 295 [Minimum bending radius (during installation) ‘mm 636 [Maximum pulling tension through conductor RN, 30 |Max. permissible short circuit current through Phase kA 21.46 [Conductor for 1 second IMax. permissible continuous conductor temp. °C 90 LMax. permissible short circuit conductor temp. =C 250 3-phase voltage drop factor ViA/km 0311 [Continuous current rating: (for Phase conductor) Single circuit in ground: Amps 253 |. Soil thermal resistivity 2 °C/W, - Soil temperature 40°C - Direct burial at 700 mm depth | Free air & shaded area at 55 °C ambient temp. ‘Amps 288 Printed by: Eng. EYAD Reviewed By: S.Eng, A.Darweesh 13-Sep-2018 FORM# TE/A/F/07 Issue no.00 08.12.1998 ‘TECHNICAL DEPARTMENT ae RIYADH CABLES GROUP COMPANY P.O. Box 26862, Riyadh 11496 Saudi Arabia DIMENSIONAL DATA FOR 4x120mm? CU/XLPE/SWA/PVC 1 kV DESCRIPTION UNIT DETAILS [Reference Standard TEC 60502-1 [Rated voltage of cable UolU wa Os! [Number of cores (Ph) No, 4 [Nominal conductor cross-sectional area (Ph) mm? 120 Shape of conductors (Ph) Sectoral Compacted (Class 2) [Conductor material i Copper |Number of strands (Ph) No. 37 [Approximate diameter of conductor (Pl) mm 12.2 [insulation material XLPE |Nominal thickness of XLPE insulation(Ph mam 12 fa [Approximate diameter over insulation(Ph) mm 146 [Approximate diameter over Laid up cores ‘mm 34.2 IMaterial of inner sheath PVC |Nominal thickness of PVC inner sheath mm 14 [Approximate diameter over inner sheath mm) 375 |Material of the metallic armour | Round Galvanized Steel Wires Nominal armour wire diameter No. x mm, 42x25 (pproximate diameter over armour mm | 42.5 [Material of outer sheath Extruded PVC-ST2 |Nominal thickness of PVC outer sheath mm 25 {proximate overall diameter of cable ‘mm 48 {proximate weight of complete cable kgikm 7080 [Colour of insulation RED, YELLOW, BLUE, BLACK [Colour of outer sheath Sls BLACK Ph: Phase Printed by: Eng. EYAD Reviewed By: S.Eng. A.Darweesh Approved as 13-Sep-2018 Sao TRCHNICAL DEPART FORM# TE/A/F/07 Issue no.00 08.12.1998 Page 1 of 2 RIYADH CABLES GROUP COMPANY P.O, Box 26862, Riyadh 11496 Saudi Arabia CABLE'S PARAMETERS FOR 4x 120mm? CU/XLPE/SWA/PVC I kV DESCRIPTION UNIT DETAILS [Rated voliage of cable WoT KV oe |Highest operating voltage Umax kv ae | [Phase conductor DC resistance at 20°C ‘Qikm: 0.1530 [Phase conductor AC resistance at 90°C km 0.1972 3-phase inductance ‘mim 0.225 S-phase reactance ai 60 Hz ‘Qik 0.085 3-phase impedance at 90°C km | 0.215 [S-phase capacitance | prc 0.159 [Minimum insulation resistance at 20°C MQ.km 290 [Minimum bending radius (during installation) ‘mm, 576 [Maximum pulling tension through conductor kN 24 [Max. permissible short circuit current through Phase [Conductor for 1 second ee a leaiasosts [Max. permissible continuous conductor temp. °C 90 | [Max. permissible short circuit conductor temy 0 250 [3-phase voltage drop factor ViA/kan 0.362 |Continuous current rating: (for Phase conductor) Single circuit in ground: ‘Amps 226 - Soil thermal resistivity 2 °Cm/W, - Soil temperature 40°C - Direct burial at 700 mm depth | Free air & shaded area at 55 °C ambient temp. ‘Amps 252 Prine bye Bog. EYAD Reviewed By: Sng. ADarweesh Approved by TBS 13-Sep-2018 ay ‘TECHNICAL DEPARTMENT FORMi#TE/A/F/07 Issue no.00 08.12.1998 Page 2 of 2 RIYADH CABLES GROUP COMPANY P.O. Box 26862, Riyadh 11496 Saudi Arabia ee 7 DIMENSIONAL DATA FOR aaceeres 4x 95mm? CU/XLPE/SWA/PVC 1 kV DESCRIPTION UNIT DETAILS Reference Standard TEC 60502-1 IRated voltage of cable Uo kV 0.6/1 Number of cores (Ph) No. 4 [Nominal conductor cross-sectional area (Ph) man 95 Shape of conductors (Ph) Sectoral Compacted (Class 2) [Conductor material — eee - Copper Number of strands (PI) No. 19 [Approximate diameter of conductor (Ph) mm 11.0 [insulation material XLPE |Nominal thickness of XLPE insulation(Ph) mam 1 [Approximate diameter over insulation(Ph) mm 13.2 [Approximate diameter over Laid up cores mm. 30.6 [Material of inner sheath Pvc [Nominal thickness of PVC inner sheath mm 12 [Approximate diameter over inner sheath mm. 335 [Material of the metallic armour Round Galvanized Steel Wires |Nominal armour wire diameter No.x mm 47x2 |Approximate diameter over armour mm 375 Pee [Material of outer sheath Extruded PVC-ST2 [Nominal thickness of PVC outer sheath mm. 23 [Approximate overall diameter of cable mm B | Approximate weight of complete cable kghkm_ 5490 |Colour of insulation RED, YELLOW, BLUE, BLACK [Colour of outer sheath _ Ph: Phase Printed by: Eng. EVAD Reviewed By: Eng. A.Darweesh 13-Sep-2018 i ‘TECHNICAL DEPARTMENT Wann FORM TE/A/F/07 Issue no.00 08.12.1998 Page 1 of2 RIYADH CABLES GROUP COMPANY P.O. Box 26862, Riyadh 11496 Saudi Arabia CABLE'S PARAMETERS FOR 4x95mm? CU/XLPE/SWA/PVC 1 kV DESCRIPTION UNIT DETAILS [Rated voltage of cable Vol a 0.611 |Highest operating voltage Umax kV, 12 [Phase conductor DC resistance at 20°C ‘Q/km 0.1930 [Phase conductor AC resistance at 90°C. ‘Q/km 0.2478 3-phase inductance in 0.295 [S-phase reactance at 60 Hz ‘Q/km 0.085 [3-phase impedance at 90°C. [orem 0.262 [S-phase capacitance p/m 0.159 [Minimum insulation resistance at 20°C MQ.km 295 [Minimum bending radius (during installation) ‘mm 516 [Maximum pulling tension through conductor kN 19 |Max. permissible short circuit current through Phase kA 13.59 [Conductor for 1 second |Max. permissible continuous conductor temp. 2c. 90. [Max. permissible short circuit conductor temp. °C 250 S-phase voltage drop factor ViA/km 0.432, [Continuous current rating: (for Phase conductor) Single circuit in ground: Amps 200 - Soil thermal resistivity 2 °Cm/W, - Soil temperature 40 °C |- Direct burial at 700 mm depth - Free air & shaded area at 55 °C ambient teny ‘Amps 219 Printed by: Eng, EYAD Reviewed By: SEng. A.Darweesh 13-Sep-2018 FORM# TE/A/F/07 Issue no.00 08.12.1998 Page 2 of 2 RIYADH CABLES GROUP COMPANY P.O. Box 26862, Riyadh 11496 Saudi Arabia DIMENSIONAL DATA FOR 4x70mm? CU/XLPE/SWA/PVC 1 kV DESCRIPTION UNIT DETAILS [Reference Standard pee TEC 60502-1 Rated voltage of cable Uo/U kV 0.6/1 [Number of cores (Ph) No. 4 [Nominal conductor cross-sectional area (Ph) mm? 70 | Shape of conductors (Ph) Sectoral Compacted (Class 2) (Conductor material ‘Copper Number of strands (Ph) No. 19 | Approximate diameter of conductor (Ph). mm 91 [Insulation material XLPE [Nominal thickness of XLPE insulation(Ph) mm : 11 LApproximate diameter over insulation(Ph) | mm 113 |4pproximate diameter over Laid up cores mm 27.1 |Material of inner sheath PVC [Nominal thickness of PVC inner sheath mm 12 [Approximate diameter over inner sheath mm 30 Material of the metallic armour Round Galvanized Steel Wires |Nominal armour wire diameter ‘No. x mm 42x2 |Approximate diameter over armour mm 34 |Material of outer sheath Extruded PVC-ST2 [Nominal thickness of PVC ouier sheath mam 22 [Approximate overall diameter of cable mm 39 |Approximate weight of complete cable kg/km 4320 |Colour of insulation RED, YELLOW, BLUE, BLACK [Colour of outer sheath BLACK Ph: Phase Printed by: Eng. EYAD Reviewed By: SEng. A.Darweesh ‘13-Sep-2018 FORM TE/A/F/07 Issue no.00 08.12.1998 Page 1 of 2 RIYADH CABLES GROUP COMPANY P.O. Box 26862, Riyadh 11496 Saudi Arabia CABLE'S PARAMETERS FOR 4x70:mm? CU/XLPE/SWA/PVC 1 kV DESCRIPTION UNIT DETAILS [Rated voltage of cable Uo aa ort lilighest operating voltage Umax WV 12 Phase conductor DC resistance at 20°C ‘km 0.2680 Phase conductor AC resistance at 90°C ‘Oikm 0.3429 S-phase inductance mH/km 0.232, 3-phase reactance at 60 Hz Qik 0.087 3-phase impedance at 90°C km 0.354 3-phase capacitance pFkm 0.153, = [Minimum insulation resistance at 20°C MQ.km 345 [Minimum bending radius (during installation) ‘mm 468 [Maximum pulling tension through conductor kN 14 IMax. permissible short circuit current through Phase Conductor for 1 second us 1002 [Max. permissible continuous conductor temp. °C 90. [Max. permissible short circuit conductor temp. °C 250 [3-phase voltage drop factor Vial 0.566 (Continuous current rating: (for Phase conductor) Single circuit in ground: Amps 168 - Soil thermal resistivity 2 °Cm/W, - Soil temperature 40 °C |- Direct burial at 700 mm depth | Free air & shaded area at 55 °C ambient temp. ‘Amps 179 Printed by: Eng. EYAD Reviewed By: S.Eng. A.Darweesh 13-Sep-2018 FORM# TE/A/F/07 Issue n0.00 08.12.1998 Page 2 of 2 RIYADH CABLES GROUP COMPANY P.O. Box 26862, Riyadh 11496 Saudi Arabia DIMENSIONAL DATA FOR 4x50mm? CU/XLPE/SWA/PVC 1 kV DESCRIPTION UNIT DETAILS Reference Standard 7 TEC 60502-1 [Rated voltage of cable Vol kv 0.6/1 i] Number of cores (Ph) No. 4 [Nominal conductor cross-sectional area (Ph) mm? 50 Shape of conductors (Ph) Sectoral Compacted (Class 2) [Conductor material i Copper [Number of strands (Ph) No. 19 [Approximate diameter of conductor (Ph) mm) 75 |insulation material XLPE |Nominal thickness of XLPE insulation(Ph) mm 1.0 L4pproximate diameter over insulation(Ph) mm) 95 [Approximate diameter over Laid up cores mm 23.2 |Material of inner sheath PVC [Nominal thickness of PVC inner sheath mm 10 [Approximate diameter over inner sheath ‘mm 25.7 [Material of the metallic armour Round Galvanized Steel Wires Nominal armour wire diameter No. x mm. 45x16 |Approximate diameter over armour mm. 28.9 z |Material of outer sheath Extruded PVC-ST2 |Nominal thickness of PVC outer sheath mam 2.0 Approximate overall diameter of cable ‘mm 33 [Approximate weight of complete cable | kg/km 3020 |Cotour of insulation RED, YELLOW, BLUE, BLACK [Colour of outer sheath BLACK oe hi Phase Printed by: Eng. EYAD Reviewed By: S.Eng. A.Darweesh 13-Sep-2018 FORM# TE/A/F/07 Issue no.00 08.12.1998 Page 1 of 2 RIYADH CABLES GROUP COMPANY P.O. Box 26862, Riyadh 11496 Saudi Arabia CABLE'S PARAMETERS FOR 450mm? CU/XLPE/SWA/PVC 1 kV DESCRIPTION UNIT DETAILS [Rated voltage of cable Uo/U kV oo lHighest operating voltage Umax kV 12 [Phase conductor DC resistance at 20°C km 0.3870 [Phase conductor AC resistance at 90°C ‘Qikm 0.4943 S-phase inductance cm 0.236 |3-phase reactance at 60 Hz km | 0.089 |3-phase impedance at 90°C Ovkin 0.502 [3-phase capacitance Fm 0.149 [Minimum insulation resistance at 20°C MQ.km 380 [Minimum bending radius (during installation) mm 396 [Maximum pulling tension through conductor kN 10 [Max, permissible short circuit current through Phase te aaa Conductor for 1 second : [Max. permissible continuous conductor temp. °C 90, [Max. permissible short circuit conductor temp. °C 250 S-phase voltage drop factor ViAikm 0.777 Continuous current rating: (for Phase conductor) Single circuit in ground: Amps 137 |- Soil thermal resistivity 2 °Cm/W, - Soil temperature 40°C |- Direct burial at 700 mm depth |- Free air & shaded area at 55 °C ambient temp Amps 142 Printed by: Eng. EYAD Reviewed By: SIEng.A.Darweesh Approved by BE 13-Sep-2018 2 ‘TECHINICAL DEPARTMENT | FORM TE/A/F/07 Issue n0.00 08.12.1998 Page 2 0f2 RIYADH CABLES GROUP COMPANY P.O. Box 26862, Riyadh 11496 Saudi Arabia DIMENSIONAL DATA FOR 4x35mm? CU/XLPE/SWA/PVC 1 kV DESCRIPTION UNIT DETAILS IReference Standard oe TEC 60502-1 lRated voltage of cable Uo 0.6/1 | INumber of cores (Ph) 4 [Nominal conductor cross-sectional area (Ph) 35 |Shape of conductors (Ph) Sectoral Compacted (Class 2) [Conductor material Copper |Number of strands (Ph) No. 7 [Approximate diameter of conductor (Pl) mm 66 linsulation material z XLPE |Nominal thickness of XLPE insulation(Ph) mam 09 [Approximate diameter over insulation(Ph) mm 8.4 [Approximate diameter over Laid up cores mm 19.8 i |Material of inner sheath PVC [Nominal thickness of PYC inner sheath mm 1.0 Approximate diameter over inner sheath mm 22.3 |Material of the metallic armour Round Galvanized Steel Wires |Nominal armour wire diameter No. x mm, 40x16 [Approximate diameter over armour mm 25.5 [Material of outer sheath Extruded PVC [Nominal thickness of PVC outer sheath mm 19 | Approximate overall diameter of cable mm. 30 [Approximate weight of complete cable kg/km : 2380 [Colour of insulation RED, YELLOW, BLUE, BLACK [Colour of outer sheath BLACK Ph: Phase Printed by: Eng. EYAD 13-Sep-2018 FORM TE/A/F/07 Issue no.00 08.12.1998, Reviewed By: S.Eng, A.Darweesh Page 1 of 2 RIYADH CABLES GROUP COMPANY P.O. Box 26862, Riyadh 11496 Saudi Arabia CABLE'S PARAMETERS FOR 4x3Smm? CU/XLPE/SWA/PVC 1 kV DESCRIPTION UNIT DETAILS [Rated voltage of cable UolT KV 061 [Highest operating voltage Umax KV, 7 12 [Phase conductor DC resistance at 20°C Qik 0.5240 [Phase conductor AC resistance at 90°C Qik. 0.6688 [S-phase inductance mil/km 0.237 [3-phase reactance at 60 Hz Qukm. 0.089 |3-phase impedance at 90°C Qik | 0.675 [S-phase capacitance FV 0.149 [Minimum insulation resistance at 20°C MQ.km 385 [Minimum bending radius (during installation) ‘mm, 360 [Maximum pulling tension through conductor kN 7 |Max. permissible short circuit current through Phase ie Fai Conductor for 1 second = |Max. permissible continuous conductor temp. °C 90 [Max. permissible short circuit conductor temp. °C. 250 [3-phase voltage drop factor ‘V/A/kan 1.019 |Continuous current rating: (for Phase conductor) Single circuit in ground: Amps 116 |- Soil thermal resistivity 2 °C/W, - Soil temperature 40 °C Direct burial at 700 mm depth - Free air & shaded area at 55 °C ambient temp. ‘Amps 18 Printed by: Eng. EYAD Reviewed By: Eng. A.Darweesh 13-Sep-2018 FORM# TE/A/F/07 Issue n0.00 08.12.1998 Page 2 of 2 RIYADH CABLES GROUP COMPANY P.O. Box 26862, Riyadh 11496 Saudi Arabia DIMENSIONAL DATA FOR 4x25mm? CU/XLPE/SWA/PVC 1 kV DESCRIPTION UNIT DETAILS [Reference Standard ee TEC 60502-1 [Rated voltage of cable UolU KV 0.6/1 [Number of cores (Ph) No. 4 |Nominal conductor cross-sectional area (Ph) mm 25 Shape of conductors (Ph) Round Compacted (Class 2) [Conductor material Copper [Number of strands (Ph) No. 7 |Approximate diameter of conductor (PW) mm 39 [insulation material XLPE [Nominal thickness of XLPE insulation(Ph) mun mr) lApproximate diameter over insulation(Ph) mm 71 [Approximate diameter over Laid up cores mm 186 [Material of inner sheath PVC [Nominal thickness of PVC inner sheath mm 10 [Approximate diameter over inner sheath mm 211 [Material of the metallic armour Round Galvanized Steel Wires |Nominal armour wire diameter No.x mm 37x16 [Approximate diameter over armour Seton 243 [Material of outer sheath Extruded PVC-ST2 [Nominal thickness of PVC outer sheath mm 18 [Approximate overall diameter of cable mm 28 [Approximate weight of complete cable kg/km 2070 Colour of insulation RED, YELLOW, BLUE, BLACK [Colour of outer sheath BLACK Ph: Phase Printed by: Eng. EYAD Reviewed By: S.Eng. A.Darweesh Approved ase 29-Jan-2019 AS. TECHNICAL DEPARTHIENT FORM# TE/A/F/07 Issue no.00 08.12.1998, Page 1 of 2 RIYADH CABLES GROUP COMPANY P.O. Box 26862, Riyadh 11496 Saudi Arabia CABLE'S PARAMETERS FOR 4x25mm? CU/XLPE/SWA/PVC 1 kV DESCRIPTION UNIT DETAILS [Rated voltage of cable VolU O.6/L [Highest operating voltage Umax 12 [Phase conductor DC resistance at 20°C 0.7270 [Phase conductor AC resistance at 90°C 0.9275 [3-phase inductance Partie 0.242 [S-phase reactance at 60 Hz eZ 0.091 [3-phase impedance at 90°C aa 0.932, 3-phase capacitance 0.145 [Minimum insulation resistance at 20°C 425 [Minimum bending radius (during installation) 336 [Maximum pulling tension through conductor 5 |Max. permissible short circuit current through Phase tk ae [Conductor for 1 second : |Max. permissible continuous conductor temp. 5c; 90 |Max. permissible short circuit conductor temp. °C 250 3-phase voltage drop factor ViA/km 1.38 [Continuous current rating: (for Phase conductor) \Single circuit in ground: Amps 99. |. Soil thermal resistivity 2 °Cm/W, |- Soil temperature 40°C |- Direct burial at 700 mm depth | Free air & shaded area at 55°C ambient temp. ‘Amps 101 Printed by: Eng. EYAD 29-Jan-2019 Reviewed By: S.Eng. A.Darweesh FORM# TE/A/F/07 Issue n0.00 08.12.1998, Varig RIYADH CABLES GROUP COMPANY P.O. Box 26862, Riyadh 11496 Saudi Arabia DIMENSIONAL DATA FOR 4x1 6mm? CU/XLPE/SWA/PVC 1 kV DESCRIPTION UNIT DETAILS [Reference Standard _ TEC 60502-1 |Rated voltage of cable Uo/U 0.6/1 [Number of cores (Ph) 4 [Nominal conductor cross-sectional area (Pi) mm? 16 Shape of conductors (Ph) Round Compacted (Class 2) [Conductor material Copper [Number of strands (Ph) No. 7 [Approximate diameter of conductor (Ph) mm 47 Insulation material XLPE |Nominal thickness of XLPE insulation(Ph) mm 07 |Approximate diameter over insulation(Ph) mm i 6.1 |Approximate diameter over Laid up cores mm 148 |Material of inner sheath PVC |Nominal thickness of PVC inner sheath ‘mm 10 |Approximate diameter over inner sheath mm 173 [Material of the metallic armour Round Galvanized Steel Wires Nominal armour wire diameter No. xmm_ 30x 1.6 [Approximate diameter over armour mm, ~ 20.5 lMaterial of outer sheath Extruded PVC-ST2 [Nominal thickness of PVC outer sheath mm 18 [Approximate overall diameter of cable mm 24 [Approximate weight of complete cable kg/km 1500 [Colour of insulation RED, YELLOW, BLUE, BLACK. |Colour of outer sheath BLACK Ee Phe Phase Printed by: Eng. EYAD Reviewed By: S.Eng. A.Darweesh 29-Jan-2019 FORM# TE/A/F/07 Issue n0.00 08.12.1998 Page 1 of 2 RIYADH CABLES GROUP COMPANY P.O. Box 26862, Riyadh 11496 Saudi Arabia CABLE'S PARAMETERS FOR dx 16mm? CU/XLPE/SWA/PVC 1 kV DESCRIPTION UNIT DETAILS [Rated voltage of cable UolT iW oe | Highest operating voltage Umax KV 12 [Phase conductor DC resistance at 20°C ‘O/km 1.1500 [Phase conductor AC resistance at 90°C ‘Qik 1.4667 |3-phase inductance mH/km 0.241 3-phase reactance at 60 Hz ‘Qikm 00 |3-phase impedance at 90°C ‘Q/km. 1.47 _| |3-phase capacitance uF/km 0.146 | Minimum insulation resistance at 20°C MQ.km AIS [Minimum bending radius (during installation) mm, 288 | Maximum pulling tension through conductor kN 32, |Max. permissible short cireuit current through Phase ie ioe |Conductor for 1 second : |Max. permissible continuous conductor temp. °C 90 |Max. permissible short circuit conductor temp. eC) 250. |3-phase voltage drop factor ViA/km 2.127 [Continuous current rating: (for Phase conductor) | Single circuit in ground: Amps 7 |- Soil thermal resistivity 2 °Cm/W, - Soil temperature 40 °C |- Direct burial at 700 mm depth | Free air & shaded area at 55 °C ambient temp. “Amps 75 Printed by: Eng. EYAD Reviewed By: S.Eng. A.Darweesh Approved 29-Jan-2019 DEPARTMENT FORM# TE/A/F/07 Issue no.00 08.12.1998 Page 2of 2 RIYADH CABLES GROUP COMPANY P.O. Box 26862, Riyadh 11496 Saudi Arabia DIMENSIONAL DATA FOR 4x10mm? CU/XLPE/SWA/PVC 1 kV | DESCRIPTION UNIT DETAILS iReference Standard Sei TEC 60502-1 Rated voltage of cable UolU kV 6/1 [Number of cores (Ph) No. 4 |Nominal conductor cross-sectional area (Ph) mm’ 10 |Shape of conductors (Ph) Round Stranded (Class 2) Conductor material Copper - [Number of strands (PI No. 7 [Approximate diameter of conductor (Ph) mm 40 [insulation material XLPE [Nominal thickness of XLPE insulation(Ph mam 07 [Approximate diameter over insulation(Ph) mm_ 54 L4pproximate diameter over Laid up cores mm. 13.1 |Material of inner sheath PVC |Nominal thickness of PVC inner sheath mm 10 [Approximate diameter over inner sheath mm 156 [Material of the metallic armour ivanized Steel Wires Nominal armour wire diameter No. xmm 35x 1.25 | Approximate diameter over armour mm Fe 18.1 [Material of outer sheath Extruded PVC-ST2 [Nominal thickness of PVC outer sheath mm 18 L4pproximate overall diameter of cable mm) 22 [Approximate weight of complete cable kg/km 1090 [Colour of insulation RED, YELLOW, BLUE, BLACK [Colour of outer sheath BLACK Ph: Phase Printed by: Eng. EYAD Reviewed By: S.Eng, A.Darweesh 13-Sep-2018 | FORM# TE/A/F/07 Issue no.00 08.12.1998 Page 1 of 2

You might also like