Professional Documents
Culture Documents
SR NO. : 690_22-23
G E O T E C H N I C A L IN VE S T I G A T IO N S F O R
S T A N D A RD P EN E T RA T I O N TE ST A N D
P L A T E L OA D T ES T AT B H A R A TP U R .
CLIENT
M / S . G A I N FR A PV T . L T D.
PROGRAMME
SEPTEMBER - 2022
Revision
SR. No. Report No. Date
No.
690_22-23 CEGTH/GAI/SR-690/2022-23/890_(08 BHs) 02 23.09.2022
690_22-23 CEGTH/GAI/SR-690/2022-23/875_(08 BHs) 01 22.09.2022
690_22-23 CEGTH/GAI/SR-690/2022-23/841_(07 BHs) 00 15.09.2022
To,
GA Infra Pvt. Ltd.
Plot no. 61, Keshav Nagar,
Hawa Sadak,
Jaipur-302006, (Rajasthan)
Subject :- Geotechnical Investigations for Standard Penetration Test and Plate Load Test at
Bharatpur.
Dear Sir,
We are pleased to submit this report of the subject work based on 08 boreholes carried out at the
proposed project site.
The accompanying report presents results of field tests and laboratory tests conducted on selected
soil samples and their interpretation.
Should there be any clarifications regarding the contents please contact us at your most convenient
time.
We value the opportunity to participate in this project and look forward a pleasant association on
future projects.
CONTENTS
PAGE
S. NO. ITEMS
NO.
CHAPTER 1 GENERAL
1.0 INTRODUCTION 1
2.0 SITE LOCATION & GENERAL GEOLOGICAL HISTORY 1
3.0 SCOPE OF WORK 1-2
4.0 FIELD INVESTIGATION 2-4
5.0 LABORATORY INVESTIGATION 4-10
CHAPTER 2 ANALYSIS OF TEST RESULTS AND INTERPRETATION
6.0 STRATIFICATION 11-12
6.1 GROUND WATER TABLE DEPTH 12
6.2 RESULTS OF CHEMICAL ANALYSIS 12
6.3 COMPUTATION OF LIQUEFACTION POTENTIAL 13-14
CHAPTER 3 TYPE AND DEPTH OF FOUNDATION WITH ANALYSIS
7.0 TYPE & DEPTH OF FOUNDATION 15
7.1 ANALYSIS OF FOUNDATION 15-17
CHAPTER 4 RECOMMENDATIONS
8.0 FOUNDATION RECOMMENDATIONS 18-20
ABBREVIATIONS 21
LIST OF FIGURES / TABLES
Appendix
ITEMS PAGE NO.
No.
APPENDIX – A (FIELD DATA RESULTS)
A-1 LOCATION PLAN 23
A-2 FIELD BORE HOLE LOGS 24-46
A-3 SUB SOIL PROFILE DIAGRAM 47
APPENDIX – B (LAB TEST RESULTS)
B-1 SOIL CHARACTERISTICS SHEETS 49-62
B-2 RESULT OF CHEMICAL ANALYSIS OF SOIL SAMPLES 63
B-3 GSD CURVES 64-71
APPENDIX – C (ANALYSIS & RECOMMENDATION)
CALCULATION FOR COMPUTATION OF LIQUEFACTION 73-80
C-1
POTENTIAL
SAMPLE CALCULATION FOR COMPUTATION OF ALLOWABLE 81-84
C-2
BEARING CAPACITY OF SUB-STRATA FOR RAFT FOUNDATION
CHAPTER 1 GENERAL
1.0 INTRODUCTION:
The work of conducting “Geotechnical Investigations for Standard Penetration Test and Plate
Load Test at Bharatpur.” by M/S. “GA Infra Pvt. Ltd.” as per reference no. WO/Bharatpur Town
Flood Control Drainage/June-2022/01, dated 16-06-2022.
Field work including drilling of one borehole and sample collection was carried out in the presence
of representative of Client. Laboratory tests were conducted on selected soil samples to determine
the design parameters, confirming to relevant IS specifications and the guidelines received from
time to time from representative of Client.
This report includes the details of Methodology of Investigation, collection of samples (soil),
laboratory test results, analysis of results and recommendations for results for proposed structures
based on soil sample collected from the locations of boreholes.
The details of the site & test locations for the proposed project are shown in location plan attached
vide Appendix A-1.
The stipulated scope of work involved carrying out the following operations:-
a) Mobilisation of necessary plant equipment, men and materials for the complete Geotechnical
investigation work as per specifications, drawings and instructions of the Engineer and to complete
the same within the stipulated time schedule and demobilisation after completion of field work.
b) Shifting of Equipments from one structure location to another including erection, installation of
rigs at site and dismantling of the same after completion of field work.
c) Making 150 mm nominal diameter borehole at various locations in all types of soil and conducting
Standard Penetration Test at every 1.5 m interval or every change of strata as per IS : 2131 : 1981
including collection of disturbed / undisturbed soil samples at every 3.00m Intervals and recording
depth of ground water table.; transportation of all the collected samples to the laboratory and back
filling of boreholes on completion of the same, complete as per specification and instructions of
the Engineer, for depths below natural ground level.
d) Conducting various laboratory tests on soil samples at an approved laboratory including
preparation of soil samples to determine the following properties of soil, all complete as per
specification.
1 of 84
Geotechnical Investigations for Standard Penetration Test and Plate Load Test at Bharatpur. SR-690_22-23
On soil Samples
o Dry density test
o Bulk Density and Moisture Content.
o Sieve Analysis
o Hydrometer Analysis
o Liquid Limit and Plastic Limit
o Shrinkage Limit
o Specific gravity
o Direct Shear Test
o Box Shear Test (in case of sand)
o Triaxial Shear Tests
o i) Unconsolidated undrained
e) Conducting chemical tests on Soil samples to determine the Sulphate, chloride, and pH value, any
other chemicals harmful to foundation material, all complete as per specification.
f) Submitting draft report including all field records and laboratory test results, graphs, etc., all
complete as per specifications.
The investigation was planned to obtain the subsurface stratification in the proposed project site
and collect soil samples for laboratory testing to determine the engineering properties such as shear
strength, along with basic engineering classification of the subsurface stratum.
For geotechnical investigation work, required equipements along with rotary drilling rigs and
manpower were mobilized at site to carry out various field activities as per the scope of work.
These were shifted from one test location to another location during execution of field work and
were demobilized on satisfactory completion of field work.
For conducting the field investigations the following practices were followed at site:
The locations of 08 boreholes were marked at site at specified locations. These locations are
shown in Appendix A-1 attached subsequently.
The details of borehole / test location along with their coordinates are provided herein below:
2 of 84
Geotechnical Investigations for Standard Penetration Test and Plate Load Test at Bharatpur. SR-690_22-23
In soil, boreholes of 150mm dia. were drilled as per the standard procedure laid in IS: 1892.
Casing was used as per the prevailing soil conditions, to stabilize the borehole.
Undisturbed / disturbed samples were collected wherevery feasible as per the requirements
and at specified depths / levels. The same has been discussed in detail in soil characteristics
sheets attached with the report.
Water table was encountered at site varies from 1.35m to 2.70m depth below EGL.
The detailed procedure adopted for conducting various field tests is given here in below:
The Standard Penetration Test was conducted in boreholes as per IS 2131. The test was carried out
using the standard split spoon sampler to measure the number of blows ‘N’.
Standard split spoon sampler was attached to an ‘A’ rod. It was driven from borehole bottom to a
distance of 45 cm using a standard hammer of 63.5 kg falling freely from a height of 75 cm to the
required depth. While driving, the number of blows required to penetrate every 15 cm are recorded.
The total number of blows required for the last 30 cm is taken as ‘N’ value at that particular depth
of the borehole. Wherever the total penetration was less than 45cm, the no. of blows & the depth
penetrated is recorded in the respective borelog.
SPT ‘N’ values were correlated with relative density of non-cohesive stratum and with consistency of
cohesive stratum as given below:-
CEG Test House & Research Centre Pvt. Ltd.
3 of 84
Geotechnical Investigations for Standard Penetration Test and Plate Load Test at Bharatpur. SR-690_22-23
Table 1.2: Soil compactness as per SPT N values (cl. 9.7, table 9.3 & 9.4, page 330_text book
of V.N.S. Murthy)
Correlation for Clay / Plastic silt Correlation for Sand / Non-Plastic silt
Consistency SPT "N" Value Compactness SPT "N" Value
Very Soft 0-2 Very Loose 0-4
Soft 2-4 Loose 4 - 10
Medium 4-8 Medium 10 - 30
Stiff 8 - 15 Dense 30 - 50
Very Stiff 15 - 30 Very Dense > 50
Hard > 30
(a) For overburden: - The N value for cohesionless soil is corrected with the help of fig. 1 given in IS-
2131.
(b) Due to dilatancy :- Wherever N values observed below water table in fine sand, silty sand or silt was
greater than 15, then corrected N values were corrected as under:
N’ =15 + ½ (N-15)
(ii) Disturbed Sampling (Soil) in boreholes:
Disturbed soil samples were collected at a regular interval starting from ground level and at every
identifiable change of strata. Samples were immediately sealed, labeled and carefully transported to the
laboratory for testing.
4 of 84
Geotechnical Investigations for Standard Penetration Test and Plate Load Test at Bharatpur. SR-690_22-23
Note:- The detailed procedure adopted for conducting various laboratory tests is described in the following
paragraphs:
5 of 84
Geotechnical Investigations for Standard Penetration Test and Plate Load Test at Bharatpur. SR-690_22-23
Grain size analysis for the fraction passing 75 micron IS Sieve (Hydrometer method)
Calibration of Hydrometer
Hydrometer was calibrated to determine a relationship (an equation) between the effective depth
HR and corresponding hydrometer reading Rh (obtained during test).
50 to 100 gm of soil sample passing through 75 micron IS Sieve was taken. It was mixed with 100
ml of sodium hexametaphesphate solution and the mixture was warmed for about 10 minutes. It
was then transferred to the cup of the mechanical mixer and the soil suspension was stirred for 15
minutes. The soil suspension was transferred into 1000 ml measuring cylinder and distilled water
was added to make 1000ml solution. This solution was mixed vigorously. The measuring cylinder
was then allowed to stand and the stopwatch was started. Hydrometer was immersed in the
solution and reading were taken after half, one, two and four minutes. The hydrometer was then
removed slowly and kept in distilled water at the same temperature as the soil suspension.
Readings were taken after the periods of 8, 15 and 30 minutes, and one, two and four hours.
Hydrometer was removed, rinsed and placed in the distilled water after each reading. After 4 hours
reading was taken once or twice within 24 hours. Finally a reading was taken at the end of 24
hours. The temperature of the suspension was observed and recorded.
Calculations
30µ HR M HR
D= × =
980(G − 1) t t
Where,
D = diameter of particle in suspension, in mm;
µ = co-efficient of viscosity of water at the temperature of the suspension at the time of
taking the hydrometer reading, in poise;
G = specific gravity of the soil fraction used in the sedimentations analysis;
6 of 84
Geotechnical Investigations for Standard Penetration Test and Plate Load Test at Bharatpur. SR-690_22-23
30µ
M= = a constant factor for given values of µ and G at the temperature of the
980(G − 1)
suspension.
The percentage by mass (w) of particles smaller than corresponding equivalent particle diameters
(D) was calculated from the formula:
100Gs
w= × Rh
Wb (Gs −1)
Where
w = percentage finer
Wb = weight of soil
Rh = Hydrometer reading
7 of 84
Geotechnical Investigations for Standard Penetration Test and Plate Load Test at Bharatpur. SR-690_22-23
40mm. The surface of the soil was smoothed off level and parallel to the base. The support
assembly was used to position the tip of the cone so that it was just touching the top surface of the
soil, and the automatic tripping mechanism was released. The cone was allowed to penetrate into
the soil for a period of 5 (± 1) s, then the cone was locked off to stop further movement and the
penetration was recorded. The cup was refilled and the test was repeated. The two recorded
penetrations need to be within 0.5mm of each other, otherwise a third test is performed. when the
three test vary by more than 1mm the test was repeated.
Further tests were conducted, at varying water contents, in order to produce a series of cone
penetrations (usually 4) in the range 15mm to 25mm. The resulting cone penetrations were plotted
verses the water content of the test specimens. The Liquid Limit (WL) was read off the graph,
being the water content at which the line of best fit through the test points crosses 20mm
penetration.
8 of 84
Geotechnical Investigations for Standard Penetration Test and Plate Load Test at Bharatpur. SR-690_22-23
The steel ball was placed in the recess of the loading pad. The loading yoke was set in contact with
the steel ball on the loading pad. Vertical displacement dial gauge to read zero in contact with the
top of the yoke. The normal load was applied and any change in thickness of specimen was
recorded. Shear displacement dial gauge was also set to read zero. The locking screw was now
removed and two parts of the shear box were separated by advancing the spacing screws.
The specimen was sheared at constant rate of strain. The readings of the proving ring dial gauge
were noted down every 15 seconds for the first one-minute and then every 30 seconds thereafter.
The reading of change in the thickness dial gauge and shear displacement dial gauge were also
recorded at the same time interval. The test was continued until the specimen fails. The specimen
was assumed to fail when the proving ring dial gauge started receding or at shear displacement of
approximately 15% of the length took place.
The soil was removed from the box and test was repeated on the identical specimen under
increased normal load.
9 of 84
Geotechnical Investigations for Standard Penetration Test and Plate Load Test at Bharatpur. SR-690_22-23
10 of 84
Geotechnical Investigations for Standard Penetration Test and Plate Load Test at Bharatpur. SR-690_22-23
From the study of the borehole logs of 07 Boreholes it is revealed that the sub strata :
At the location of BH-01:-
a) From existing ground level to 2.25 m depth, strata consists of filled up soil.
b) From 2.25m depth to 8.65m depth,, strata consists of Coarse grained Soil i.e., Sandy Silt with low
plasticity.
c) From 8.65m 11.65m, strta consisit of fine grained soil i.e. SIlty Clay with low plasticity.
d) From 11.65m depth to termination depth,, strata consists of Coarse grained Soil i.e., Silty Sand.
At the location of BH-02:-
a) From existing ground level to 1.50 m depth, strata consists of filled up soil.
b) From 1.50m 5.65m, strta consisit of fine grained soil i.e. SIlty Clay with low plasticity.
c) From 5.65m 8.65m, strata consists of Coarse grained Soil i.e., Silty Sand
d) From 8.65m depth to 19.15m depth,, . SIlty Clay with medium, plasticity.
e) From 19.15m depth to termination depth,, strata consists of Coarse grained Soil i.e., Silty Sand.
At the location of BH-03:-
a) From existing ground level to 1.50 m depth, strata consists of filled up soil.
b) From 1.50m 4.15m, strta consisit of fine grained soil i.e. SIlty Clay with medium plasticity.
c) From 4.15m 7.15m, strta consisit of fine grained soil i.e. SIlty Clay with l ow plasticity.
d) From 7.15m 20.65m,, strata consisit of fine grained soil i.e. SIlty Clay with medium plasticity.
e) From 20.65m depth to termination depth, strata consists of Coarse grained Soil i.e., Sandy Silt
with low plasticity.
At the location of BH-04:-
a) From existing ground level to 1.50 m depth, strata consists of filled up soil.
b) From 1.50m 2.65m, strta consisit of fine grained soil i.e. SIlty Clay with medium plasticity.
c) From 2.65m 11.65m, strta consisit of fine grained soil i.e. SIlty Clay with low plasticity.
d) From 11.65m depth to termination depth, strta consisit of fine grained soil i.e. SIlty Clay with
medium plasticity.
At the location of BH-05:-
a) From existing ground level to 1.50 m depth, strata consists of filled up soil.
b) From 1.50m depth to termination depth, strta consisit of fine grained soil i.e. SIlty Clay with
medium plasticity.
At the location of BH-06:-
a) From existing ground level to 1.50 m depth, strata consists of filled up soil.
b) From 1.50m 11.25m, strta consisit of fine grained soil i.e. SIlty Clay with medium plasticity.
CEG Test House & Research Centre Pvt. Ltd.
11 of 84
Geotechnical Investigations for Standard Penetration Test and Plate Load Test at Bharatpur. SR-690_22-23
c) From 11.25m to termination depth, strta consisit of fine grained soil i.e. SIlty Clay with low
plasticity.
At the location of BH-07:-
a) From existing ground level to 1.50 m depth, strata consists of filled up soil.
b) From 1.50m 4.15m, strata consists of Coarse grained Soil i.e., Silty Sand.
c) From 4.15m 16.15m, strta consisit of fine grained soil i.e. SIlty Clay with low plasticity.
d) From 16.15m 19.15m,, strata consists of Coarse grained Soil i.e., Sandy Silt with low plasticity.
e) From 19.15m depth to termination depth, strta consisit of fine grained soil i.e. SIlty Clay with low
plasticity.
At the location of BH-08:-
a) From existing ground level to 1.50 m depth, strata consists of filled up soil.
b) From 1.50m depth to 4.50m depth, strata consists of fine grained soil i.e. Silty clay with gravels
of low plasticity.
c) From 4.50m deopth to 7.50m depth strata consists of coarse grained soil i.e. Silty sand soil of non
plasticity
d) From 7.50m depth to termination depth strata consists of fine grained soil i.e. Silty clay with
gravels of low plasticity.
Water table was at site varies from 1.35m to 2.70m depth below EGL.
Results of chemical analysis of soil samples (as per Appendix – B2) indicates that the soil sample
falls under Class I for sulphates and chlorides concentration (As per IS 456-2000 and CIRIA Sp.
Publication No. 31). The results are summarized here in below :-
Summary of chemical analysis of soil samples
Remarks (Required limits as per IS
Chemical Property Findings
456-200)
pH 7.83 to 8.56 > 6.0
Sulphite as SO32- (%) 0.0012 (%) to 0.0037 (%) < 0.2% (Class I)
No limit specified in IS 456. However, a limit
Chlorides as Cl- (%) 0.0018 (%) to 0.0096 (%) of 0.10% specified for class I in CIRIA Sp.
Publication No. 31)
Note :- As the PH, sulphate content & chloride content are within permissible limit hence no
special precautions are required.
12 of 84
Geotechnical Investigations for Standard Penetration Test and Plate Load Test at Bharatpur. SR-690_22-23
Liquefaction is the sudden loss of shear strength of the sub soil strata due to earthquake-induced
vibration under saturated conditions.
Next threshold cyclic shear stress, which is good enough to cause liquefaction, is determined from
SPT data and the empirical relations. Finally, comparison of these two stresses is used in the
estimation of liquefaction susceptibility of the foundation strata.
Unsaturated soils are not subjected to liquefaction because vibratory forces from earthquakes do
not cause any increase in pore water pressure in such soils.
The area of site falls in seismic zone – III of India as per IS: 1893. Further as per the provisions of
IS: 1893 in soil deposits consisting of submerged loose sands & soils falling under classification of
SP with standard penetration N value less than 15, the shaking caused by earthquake ground
motion may cause liquefaction or excessive total and differential settlements.
For the analysis of liquefaction potential, following constant parameters are considered:
EQ Zone III
Earthquake Magnitude (Mw) 6.5
Peak Horizontal Ground Acceleration
0.16
(amax /g)
The Ground Water Table was encountered in all 08 Boreholes at depths varying from 1.35m to
2.70m below the existing ground level, it may rise up during heavy rains / rainy season. Therefore,
for the analysis of liquefaction potential, the water table has been considered to rise by about EGL
at the location of 08 Borehole. Therefore liquefaction analysis has been carried out & liquefaction
depths are given below
Table 2.1: Liquefaction Analysis
Water Table
Water Table Depth
Liquefiable Depth
Sl. No. Chainage No. Depth below considered for
(m)
EGL (m) analysis below
EGL (m)
1. BH-01 (Jigana Gate) 1.95 0.00 11.65
2. BH-02 (Saras Chauraha) 1.75 0.00 2.65
BH-03
3. 2.70 0.00 NL
(Pushp Vatika Colony)
BH-04(Red Cross
4. 1.35 0.00 4.15
Circle)
CEG Test House & Research Centre Pvt. Ltd.
13 of 84
Geotechnical Investigations for Standard Penetration Test and Plate Load Test at Bharatpur. SR-690_22-23
Water Table
Water Table Depth
Liquefiable Depth
Sl. No. Chainage No. Depth below considered for
(m)
EGL (m) analysis below
EGL (m)
5. BH-05 (Ganesh Temple) 2.10 0.00 NL
6. BH-06 (Nimda Gate) 1.60 0.00 NL
7. BH-07 (Annahi Gate) 1.80 0.00 7.15
8. BH-08 (Kmher Gate) 2.00 0.00 3.00
Note: - The details of sample calculation for computation of liquefaction potential are shown vide
Appendix-C1.
The strata at the location is susceptible to liquefaction for BH-01, BH-02, BH-04,BH-07 & BH-
08, it is recommended to provide suitable Ground improvement measures to mitigate before laying
the foundation.
14 of 84
Geotechnical Investigations for Standard Penetration Test and Plate Load Test at Bharatpur. SR-690_22-23
Based on the nature & strength characteristics of the substrata and requirement of the project, the
following type of foundation have been analyzed as given below:
For soils, containing both coarse grained (gravels & sands) and fine grained (clays), c and Φ are
used to determine the soil strength. In case of predominantly fine grained soils, c and Φ are
determined by the Triaxial Compression test as per IS: 2720 pt XI. For predominantly coarse
grained soils, c and Φ are determined by Direct Shear test as per IS: 2720 pt XIII. These c and Φ
values were used for determining the SBC of soil as per shear failure criteria.
The ultimate net bearing capacity in case of general shear failure is given by following expression,
qd = c Nc sc dc ic + q (Nq-1) sq dq iq + (1/2) B γ Nγ sγ dγ iγ W'
The’ultimate net bearing capacity in case of local shear failure is given by following expression,
q'd = (’/3) c N'c sc ’c ic + q (N'q-1) ’q dq iq + (1/2) B γ N'γ sγ ’γ iγ W'
Whe’e,
dc = 1+ 0.2 (Df/B)*SQRT(Nφ)
dq = dγ = 1 for φ <10o
dq = dγ = 1 + 0.1 (Df/B)*SQRT(Nφ) for φ >10o
CEG Test House & Research Centre Pvt. Ltd.
15 of 84
Geotechnical Investigations for Standard Penetration Test and Plate Load Test at Bharatpur. SR-690_22-23
Nφ = tan2(π/4 +φ/2)
φ' for ’ocal shear failure = tan-1 ( 0.67 tanφ )
The following soil parameters were selected for calculations:
Depth of
Remarks
Angle of internal
Type of foundation Cohesion ‘C’
BH No. friction(ф)
Foundation below EGL (kg/sq.cm)
(Deg.)
(m)
2.5,3.0,3.5,4.0,
BH-01 0.05 25 -
4.5 & 5.0
BH-02 4.5,5.0 & 5.5 0.03 28 -
BH-03 4.5,5.0 & 5.5 0.96 4 -
2.5,3.0,3.5,4.0,
BH-04 0.77 9 -
4.5 & 5.0
Raft 2.5,3.0,3.5,4.0,
BH-05 Foundation 0.71 9 -
4.5 & 5.0
2.5,3.0,3.5,4.0,
BH-06 0.80 8 -
4.5 & 5.0
2.5,3.0,3.5,4.0,
BH-07 0.31 7 -
4.5 & 5.0
2.5,3.0,3.5,4.0,
BH-08 0.05 26 -
4.5 & 5.0
Allowable Bearing Pressure from Settlement Failure consideration has been computed in
accordance with IS: 8009 (Part-I). The magnitude of settlement, when foundation loads are
applied, depends upon the compressibility of the underlying strata and rigidity of the substructure.
The total permissible settlement in cohesion-less soil is estimated using SPT value as per IS: 8009
(Part-I). While using this approach, the N value was corrected, wherever applicable, below the
footing base to at least 1.5B (where 'B' is the width of foundation) for the effects of energy ratio,
dilation for submerged silty fine sands / fine sands as well as that due to the overburden pressure.
Further the immediate settlements in cohesive soil are estimated using the elastic theory
considering the effect of a rigid stratum underlying the foundation soils (Reference: “Foundation
Analysis and Design” by J.E.Bowles) and for consolidation settlement in cohesive soil the
following equation has been used:
St = ∆P Mv H
Where,
Mv = Coefficient of volume compressibility, cm2/kg
∆P = Pressure increment, kg/cm2
H = Thickness of layers
CEG Test House & Research Centre Pvt. Ltd.
16 of 84
Geotechnical Investigations for Standard Penetration Test and Plate Load Test at Bharatpur. SR-690_22-23
For the analysis of Shallow foundation the total permissible settlement have been considered as
50mm as per IS 1904.
Zone of influence below foundation has been considered up to 1.5 times the width of the
foundation.
Lower of the two values obtained from settlement and shear criteria is used in arriving at allowable
bearing capacity of the soil.
Sample calculation for computation of allowable bearing capacity of sub-strata for Shallow
foundation resting on soil are attached vide Appendix C-1.
17 of 84
Geotechnical Investigations for Standard Penetration Test and Plate Load Test at Bharatpur. SR-690_22-23
• Based on the nature & strength characteristics of the substrata and requirement of the project,
Shallow foundation have been analysed at the location of boreholes.
• Based on the method of analysis & design parameters given under Para 7.1, the recommended net
allowable bearing capacity values have been tabulated below vide table no. 4.1 & 4.2 :-
Table 4.1: Recommended Net Allowable Bearing Capacity for open foundation for
allowable settlement 50mm
Capacity (t/m2)
Capacity (t/m2)
failure (t/m2)
BH` No.
(m)
Replaced Capacity
2.50 20.8 12.3 12.3 - - - -
3.00 21.9 12.4 12.4 - - - -
BH-01
18 of 84
Geotechnical Investigations for Standard Penetration Test and Plate Load Test at Bharatpur. SR-690_22-23
Capacity (t/m2)
Capacity (t/m2)
failure (t/m2)
BH` No.
(m)
Replaced Capacity
4.00 - - - 21.3 15.8 15.8
BH-04
19 of 84
Geotechnical Investigations for Standard Penetration Test and Plate Load Test at Bharatpur. SR-690_22-23
Capacity (t/m2)
Capacity (t/m2)
failure (t/m2)
BH` No.
(m)
Replaced Capacity
4.00 - - - 17.89 24.04 17.89
BH-08
Note: As the Strata encountered at site at some of the borehole location is stiff/loose, hence to get
the required capacity, strata below the foundation need to be replaced with properly compacted
granular material.. The soil to be replaced is to be well compacted in layers of thickness not more
than 150mm up to 95% of Proctor Density before laying the foundation. For replaced soil,
following Properties shall be ensured at site to achieve the tabulated above SBC.
Bulk Density Dry Density Cohesion
Phi angle SPT ‘N’ Value
(g/cm3) (g/cm3) (kg/cm2)
1.79 1.60 0.00 30 25
However for the location of BH-07 and other similar kind of strata encountered at site during
construction, needs to be improved using methods like stone column/sand column etc. as the
thickness of soft strata of this location is more.
All The above recommendations are based on the field and laboratory tests conducted on selected
soil samples and our experience in this regard. If the actual substrata conditions during excavation
for the foundation differ from the observations reported here, the design experts/consultants should
be referred for suggestion, further investigations.
20 of 84
Geotechnical Investigations for Standard Penetration Test and Plate Load Test at Bharatpur. SR-690_22-23
Abbreviations
BH Borehole
TP Trial Pit
ERT Electrical Resistivity Test
CBR California Bearing Ratio
EGL Existing Ground Level
GWT Ground Water Table
IS Indian Standards
SPT Standard Penetration Test
DS Disturbed Soil
R.L. Reduced Level
m Metre
sp. gr. Specific Gravity
% Percentage
mg /l Milligram per litre
mg /kg Milligram per kilogram
21 of 84
“Geotechnical Investigations for Standard Penetration Test and Plate Load Test at Bharatpur.” SR-690_22-23
22 of 84
“Geotechnical Investigations for Standard Penetration Test and Plate Load Test at Bharatpur.” SR-690_22-23
23 of 84
CEG Test House & Research Centre Pvt. Ltd.
FIELD BOREHOLE LOG
Project Name :GTI Work for Standard Penetration Test and Plate Load Test at Bharatpur. Client :GA Infra Pvt. Ltd.
Classification
Depth ( m )
In-SituTest
Sample &
IS
(m) Type Description Log (%) Observations
Value (%) SPT N Value)
DS
0.5
1.0
Filled up soil FILL
1.5
2.0 1.95m
2.25 UDS*
2.5
3.0 3 SPT-1 3
3.5
4.0
5.0
5.25 UDS-1
Brownish,firm, sandy
5.5 ML-CL
silt of low plasticity
6.0 6 SPT-3 6
6.5
7.0
8.0
8.25 UDS-2
8.5
8.65 SPT-5 4
9.0
Brownish to Greyish,
firm, silty clay of low CL
9.5 plasticity
10.0
UDS*-UDS not recovered
24 of 84
FIELD BOREHOLE LOG
Project Name :GTI Work for Standard Penetration Test and Plate Load Test at Bharatpur. Client :GA Infra Pvt. Ltd.
Classification
Depth ( m )
In-SituTest
Sample &
IS
(m) Type Description Log (%) Observations
Value (%) SPT N Value)
10.15 SPT-6 6
10.5
Brownish to Greyish,
firm, silty clay of low CL
11.0 plasticity
11.25 UDS*
11.5
11.65 SPT-7 36
12.0
12.5
13.0
13.15 SPT-8 38
13.5
14.0
14.25 UDS-3
14.5
14.65 SPT-9 21
15.0
15.5
Brownish, reddish to
greyish,medium to SM
16.0 dense silty sand
16.15 SPT-10 36
16.5
17.0
17.25 UDS*
17.5
17.65 SPT-11 31
18.0
18.5
19.0
19.5
20.0
UDS*-UDS not recovered
25 of 84
FIELD BOREHOLE LOG
Project Name :GTI Work for Standard Penetration Test and Plate Load Test at Bharatpur. Client :GA Infra Pvt. Ltd.
Classification
Depth ( m )
In-SituTest
Sample &
IS
(m) Type Description Log (%) Observations
Value (%) SPT N Value)
20.25 UDS*
Brownish, reddish to
20.5 greyish,medium to SM
20.65 SPT-12 55 dense silty sand
21.0 21
Classification
Depth ( m )
In-SituTest
Sample &
IS
(m) Type Description Log (%) Observations
Value (%) SPT N Value)
DS
0.5
1.75m
2.0
2.25 UDS-1
2.5
2.65 SPT-2 7
3.0
4.0
4.15 SPT-3 13
4.5
5.0
5.25 UDS-2
5.5
5.65 SPT-4 12
6.0
6.5
8.0
8.25 UDS-3
8.5
8.65 SPT-6 21
9.0
Yellowish to
brownish,very stiff to
CI
9.5 hard, silty clay of
medium platicity
10.0
UDS*-UDS not recovered
27 of 84
FIELD BOREHOLE LOG
Project Name :GTI Work for Standard Penetration Test and Plate Load Test at Bharatpur. Client :GA Infra Pvt. Ltd.
Classification
Depth ( m )
In-SituTest
Sample &
IS
(m) Type Description Log (%) Observations
Value (%) SPT N Value)
10.15 SPT-7 23
10.5
11.0
11.25 UDS-4
11.5
11.65 SPT-8 27
12.0
12.5
13.0
13.15 SPT-9 28
13.5
14.0
14.25 UDS-5
Yellowish to
14.5 brownish,very stiff to
14.65 SPT-10 32 CI
hard, silty clay of
medium platicity
15.0
15.5
16.0
16.15 SPT-11 34
16.5
17.0
17.25 UDS*
17.5
17.65 SPT-12 33
18.0
18.5
19.0
19.15 SPT-13 35
Classification
Depth ( m )
In-SituTest
Sample &
IS
(m) Type Description Log (%) Observations
Value (%) SPT N Value)
20.25 UDS*
Yellowish to brownish,
20.5 medium dense, silty SM
20.65 SPT-14 48 sand
21.0 21
Classification
Depth ( m )
In-SituTest
Sample &
IS
(m) Type Description Log (%) Observations
Value (%) SPT N Value)
DS
0.5
2.0
2.25 UDS-1
2.5
2.65 SPT-2 9
Yellowish to brownish, 2.70m
firm to stiff, silty clay of CI
3.0 medium plasticity
3.5
4.0
4.15 SPT-3 13
4.5
5.0
5.25 UDS-2
5.5 Yellowish to brownish,
5.65 SPT-4 16 stiff to very stiff, silty CL
clay of low plasticity
6.0
6.5
7.0
7.15 SPT-5 18
7.5
8.0
8.25 UDS-3
Yellowish to brownish,
8.5 very stiff to hard, silty
8.65 SPT-6 21 CI
clay of medium
plasticity
9.0
9.5
10.0
UDS*-UDS not recovered
30 of 84
FIELD BOREHOLE LOG
Project Name :GTI Work for Standard Penetration Test and Plate Load Test at Bharatpur. Client :GA Infra Pvt. Ltd.
Classification
Depth ( m )
In-SituTest
Sample &
IS
(m) Type Description Log (%) Observations
Value (%) SPT N Value)
10.15 SPT-7 25
10.5
11.0
11.25 UDS-4
11.5
11.65 SPT-8 23
12.0
12.5
13.0
13.15 SPT-9 28
13.5
14.0
14.25 UDS*
14.5
14.65 SPT-10 31
Yellowish to brownish,
15.0 very stiff to hard, silty
CI
clay of medium
plasticity
15.5
16.0
16.15 SPT-11 32
16.5
17.0
17.25 UDS*
17.5
17.65 SPT-12 37
18.0
18.5
19.0
19.15 SPT-13 40
19.5
20.0
UDS*-UDS not recovered
31 of 84
FIELD BOREHOLE LOG
Project Name :GTI Work for Standard Penetration Test and Plate Load Test at Bharatpur. Client :GA Infra Pvt. Ltd.
Classification
Depth ( m )
In-SituTest
Sample &
IS
(m) Type Description Log (%) Observations
Value (%) SPT N Value)
CI
20.25 UDS*
Yellowish to brownish,
20.5 very stiff to hard, silty CI
20.65 SPT-14 44 clay of medium
plasticity
Yellowish, very stiff, ML-CL
21.0 21 sandy silt with low
plasticity
Classification
Depth ( m )
In-SituTest
Sample &
IS
(m) Type Description Log (%) Observations
Value (%) SPT N Value)
DS
0.5
1.35m
1.5 1.5 SPT-1 4
2.5
2.65 SPT-2 5
3.0
3.5
4.0
4.15 SPT-3 7
4.5
5.0
5.25 UDS-1
5.5
5.65 SPT-4 10
6.0
Greyish to
Yellowish,firm, stiff to
CL
6.5 very stiff, silty clay of
low plasticity
7.0
7.15 SPT-5 13
7.5
8.0
8.25 UDS-2
8.5
8.65 SPT-6 16
9.0
9.5
10.0
UDS*-UDS not recovered
33 of 84
FIELD BOREHOLE LOG
Project Name :GTI Work for Standard Penetration Test and Plate Load Test at Bharatpur. Client :GA Infra Pvt. Ltd.
Classification
Depth ( m )
In-SituTest
Sample &
IS
(m) Type Description Log (%) Observations
Value (%) SPT N Value)
10.15 SPT-7 25
10.5
Greyish to
Yellowish,firm, stiff to
CL
11.0 very stiff, silty clay of
low plasticity
11.25 UDS-3
11.5
11.65 SPT-8 26
12.0
12.5
13.0
13.15 SPT-9 29
13.5
14.0
14.25 UDS-4
14.5
14.65 SPT-10 28
15.0
15.5
Brownish to yellowish,
very stiff to hard, silty
CI
16.0 clay of medium
plasticity
16.15 SPT-11 33
16.5
17.0
17.25 UDS*
17.5
17.65 SPT-12 37
18.0
18.5
19.0
19.15 SPT-13 41
19.5
20.0
UDS*-UDS not recovered
34 of 84
FIELD BOREHOLE LOG
Project Name :GTI Work for Standard Penetration Test and Plate Load Test at Bharatpur. Client :GA Infra Pvt. Ltd.
Classification
Depth ( m )
In-SituTest
Sample &
IS
(m) Type Description Log (%) Observations
Value (%) SPT N Value)
CI
20.25 UDS*
20.5 Brownish to yellowish,
20.65 SPT-13 52 very stiff to hard, silty
CI
clay of medium
plasticity
21.0 21
Classification
Depth ( m )
In-SituTest
Sample &
IS
(m) Type Description Log (%) Observations
Value (%) SPT N Value)
DS
0.5
2.0
2.10m
2.25 UDS*
2.5
2.65 SPT-2 8
3.0
3.5
4.0
4.15 SPT-3 11
4.5
5.0
5.25 UDS-1
5.5
5.65 SPT-4 16 Yellowish to
Greyish,Firm, stiff to
CI
very stiif ,hard, silty clay
6.0 of medium plasticity
6.5
7.0
7.15 SPT-5 21
7.5
8.0
8.25 UDS-2
8.5
8.65 SPT-6 24
9.0
9.5
10.0
UDS*-UDS not recovered
36 of 84
FIELD BOREHOLE LOG
Project Name :GTI Work for Standard Penetration Test and Plate Load Test at Bharatpur. Client :GA Infra Pvt. Ltd.
Classification
Depth ( m )
In-SituTest
Sample &
IS
(m) Type Description Log (%) Observations
Value (%) SPT N Value)
10.15 SPT-7 27
10.5
11.0
11.25 UDS-3
11.5
11.65 SPT-8 26
12.0
12.5
13.0
13.15 SPT-9 28
13.5
14.0
14.25 UDS-4
14.5
14.65 SPT-10 29
Yellowish to
15.0 Greyish,Firm, stiff to
CI
very stiif ,hard, silty clay
of medium plasticity
15.5
16.0
16.15 SPT-11 32
16.5
17.0
17.25 UDS*
17.5
17.65 SPT-12 36
18.0
18.5
19.0
19.15 SPT-13 44
19.5
20.0
UDS*-UDS not recovered
37 of 84
FIELD BOREHOLE LOG
Project Name :GTI Work for Standard Penetration Test and Plate Load Test at Bharatpur. Client :GA Infra Pvt. Ltd.
Classification
Depth ( m )
In-SituTest
Sample &
IS
(m) Type Description Log (%) Observations
Value (%) SPT N Value)
CI
20.25 UDS*
20.5 Yellowish to
20.65 SPT-14 49 Greyish,Firm, stiff to
CI
very stiif ,hard, silty clay
of medium plasticity
21.0 21
Classification
Depth ( m )
In-SituTest
Sample &
IS
(m) Type Description Log (%) Observations
Value (%) SPT N Value)
DS
0.5
2.0
2.25 UDS*
2.5
2.65 SPT-2 5
3.0
3.5
4.0
4.15 SPT-3 11
4.5
5.0
5.25 UDS-1
5.5
5.65 SPT-4 19 Greyish to yellowish,
firm,stiff to very stiff,
CI
hard, silty clay of
6.0 medium plasticity
6.5
7.0
7.15 SPT-5 22
7.5
8.0
8.25 UDS-2
8.5
8.65 SPT-6 24
9.0
9.5
10.0
UDS*-UDS not recovered
39 of 84
FIELD BOREHOLE LOG
Project Name :GTI Work for Standard Penetration Test and Plate Load Test at Bharatpur. Client :GA Infra Pvt. Ltd.
Classification
Depth ( m )
In-SituTest
Sample &
IS
(m) Type Description Log (%) Observations
Value (%) SPT N Value)
10.15 SPT-7 33
12.0
12.5
13.0
13.15 SPT-9 41
13.5
14.0
14.25 UDS-4
14.5
14.65 SPT-10 47
15.0
16.5
17.0
17.25 UDS-5
17.5
17.65 SPT-12 50
18.0
18.5
19.0
19.15 SPT-13 43
19.5
20.0
UDS*-UDS not recovered
40 of 84
FIELD BOREHOLE LOG
Project Name :GTI Work for Standard Penetration Test and Plate Load Test at Bharatpur. Client :GA Infra Pvt. Ltd.
Classification
Depth ( m )
In-SituTest
Sample &
IS
(m) Type Description Log (%) Observations
Value (%) SPT N Value)
CL
20.25 UDS*
20.5 Brownish to greyish,
20.65 SPT-14 38 hard, silty clay of low CL
plasticity
21.0 21
Classification
Depth ( m )
In-SituTest
Sample &
IS
(m) Type Description Log (%) Observations
Value (%) SPT N Value)
DS
0.5
1.80m
2.0
2.25 UDS*
2.5
2.65 SPT-2 4
Greyish, loose, silty
SM
3.0 sand
3.5
4.0
4.15 SPT-3 5
4.5
5.0
5.25 UDS*
5.5
5.65 SPT-4 6
6.0
6.5
8.0
8.25 UDS-1
8.5
8.65 SPT-6 12
9.0
9.5
10.0
UDS*-UDS not recovered
42 of 84
FIELD BOREHOLE LOG
Project Name :GTI Work for Standard Penetration Test and Plate Load Test at Bharatpur. Client :GA Infra Pvt. Ltd.
Classification
Depth ( m )
In-SituTest
Sample &
IS
(m) Type Description Log (%) Observations
Value (%) SPT N Value)
10.15 SPT-7 14
10.5
11.0
11.25 UDS-2
11.5
11.65 SPT-8 19
12.0
12.5
14.0
14.25 UDS-3
14.5
14.65 SPT-10 29
15.0
15.5
16.0
16.15 SPT-11 34
16.5
17.0
17.25 UDS-4
17.5 Yellowish to Greyish,
17.65 SPT-12 39 very stiff to hard, sandy ML-CL
silt with low plasticity
18.0
18.5
19.0
19.15 SPT-13 32
Classification
Depth ( m )
In-SituTest
Sample &
IS
(m) Type Description Log (%) Observations
Value (%) SPT N Value)
20.25 UDS*
Yellowish to Greyish,
20.5 very stiff to hard, silty CL
20.65 SPT-14 24 clay of low plasticity
21.0 21
Classification
Depth ( m )
In-SituTest
Sample &
IS
(m) Type Description Log (%) Observations
Value (%) SPT N Value)
DS
0.5
2.0 2.00m
2.25 UDS-1
2.5
3.5
4.0
5.0
5.25 UDS-2
5.5
Brownish medium
6.0 6 SPT-4 14 dense silty sand with SM
gravels of non plastic
6.5
7.0
8.0
8.25 UDS-3
8.5
Brownish firm, stiff to
very stiff silty clay of low CL
plasticity with gravels
9.0 9 SPT-6 12
9.5
10.0
UDS*-UDS not recovered
45 of 84
FIELD BOREHOLE LOG
Project Name :GTI Work for Standard Penetration Test and Plate Load Test at Bharatpur. Client :GA Infra Pvt. Ltd.
Classification
Depth ( m )
In-SituTest
Sample &
IS
(m) Type Description Log (%) Observations
Value (%) SPT N Value)
11.0
11.25 UDS-4
11.5
12.0 12 SPT-8 24
13.0
14.0
14.25 UDS*
14.5
15.0 15 SPT-10 32
SM CI
CLIENT GA Infra Pvt. Ltd. PROJECT NAME GTI Work for Standard Penetration Test and Plate Load Test at Bharatpur.
PROJECT NUMBER SR-690_22-23 PROJECT LOCATION Bharatpur
5 7 4 6 4 4 5
-2 -2
7 9 5 8 5 4
3 9
-4 13 13 7 11 11 5 -4
4 12
12 16 10 16 19 6
-6 6 14 -6
15 18 13 21 22 9
3 8
-8 -8
4 21 21 16 24 24 12
12
47 of 84
-10 6 23 25 25 27 33 14 -10
19
Elevation (m)
36 27 23 26 26 36 19
-12 24 -12
38 28 28 29 28 41 23
23
-14 -14
21 32 31 28 29 47 29
32
-16 36 34 32 33 32 49 34 -16
31 33 37 37 36 50 39
-18 -18
35 40 41 44 43 32
-20 -20
55 48 44 52 49 38 24
-22 -22
0 50 100 150 200 250 300 350 400
48 of 84
SOIL CHARACTERISTICS
Termination
Date of Boring Chainage/Location B.H. No. Depth of Water Table Cordinates (E,N) R.L. Ref. Code
Geotechnical Investigations for Standard Penetration Test and Plate Load Test at
Depth
Project Bharatpur.
18-08-2022 to 21-08-2022 Jigana Gate BH-01 1.95 m 21.00 m 747425.000 m 3013982.000 m - SR-690_22-23
Grain Size Distribution % wt retained Atterberg Limits % Shear Strength Consolidation Parameters
Sand Gravel
Soil Description
(N)
(%)
(cm/sec)
(kg/cm2)
Silt
Value (Nc)
IS Symbol
Clay
Limit
Index
Fine
Fine
Content (%)
Permeability
Sample Type
(kg/cm2)
Cv x 10-4
(kg/cm2)
Angle of
Pressure
Mv x 10-2
(cm2/Kg)
Plasticity
(cm2/Sec)
Corrected SPT
Coarse
Coarse
Shrinkage
Index (Cc)
Specific Gravity
IS Classification
Medium
Free Swell Index
Cohesion C
Natural Moisture
Swelling Pressure
Friction (φ°)
Type of Test
Plastic Limit
Liquid Limit
Compression
UDS* 2.25 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-2 4.50 4 6 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-3 6.00 6 8 - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-4 7.50 3 4 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
49 of 84
UDS-2 8.25 - - ML-CL - 6 53 33 5 3 0 0 25 18 7 - 1.76 21.20 1.45 2.66 DST 0.16 20 - - - - - - - -
SPT-5 8.65 4 4 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
UDS* 11.25 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-7 11.65 36 26 - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-8 13.15 38 27 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-9 14.65 21 18 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
UDS* 17.25 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
UDS* 20.25 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-12 20.65 55 31 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SOIL CHARACTERISTICS
Termination
Date of Boring Chainage/Location B.H. No. Depth of Water Table Cordinates (E,N) R.L. Ref. Code
Geotechnical Investigations for Standard Penetration Test and Plate Load Test at
Depth
Project Bharatpur.
31-08-2022 to 03-09-2022 Saras Chauraha BH-02 1.75 m 21.00 m 748741.000 m 3011783.000 m - SR-690_22-23
Grain Size Distribution % wt retained Atterberg Limits % Shear Strength Consolidation Parameters
Sand Gravel
Soil Description
(N)
(%)
(cm/sec)
(kg/cm2)
Silt
Value (Nc)
IS Symbol
Clay
Limit
Index
Fine
Fine
Content (%)
Permeability
Sample Type
(kg/cm2)
Cv x 10-4
(kg/cm2)
Angle of
Pressure
Mv x 10-2
(cm2/Kg)
Plasticity
(cm2/Sec)
Corrected SPT
Coarse
Coarse
Shrinkage
Index (Cc)
Specific Gravity
IS Classification
Medium
Free Swell Index
Cohesion C
Natural Moisture
Swelling Pressure
Friction (φ°)
Type of Test
Plastic Limit
Liquid Limit
Compression
SPT-1 1.50 5 5 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-3 4.15 13 13 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-4 5.65 12 14 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
50 of 84
Yellowish to brownish, medium
SPT-5 7.15 15 16 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
dense, silty sand
SPT-6 8.65 21 21 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-7 10.15 23 23 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-8 11.65 27 27 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-9 13.15 28 28 - - - - - - - - - - - - - - - - - - - - - - - - - - -
Yellowish to brownish,very stiff to
hard, silty clay of medium platicity
UDS-5 14.25 - - CI - 20 62 3 0 0 15 0 42 20 22 - 1.99 25.10 1.59 2.72 UUT 1.22 4 - - - - - - - -
SPT-10 14.65 32 32 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-11 16.15 34 34 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
UDS* 17.25 - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-12 17.65 33 33 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SOIL CHARACTERISTICS
Termination
Date of Boring Chainage/Location B.H. No. Depth of Water Table Cordinates (E,N) R.L. Ref. Code
Geotechnical Investigations for Standard Penetration Test and Plate Load Test at
Depth
Project Bharatpur.
31-08-2022 to 03-09-2022 Saras Chauraha BH-02 1.75 m 21.00 m 748741.000 m 3011783.000 m - SR-690_22-23
Grain Size Distribution % wt retained Atterberg Limits % Shear Strength Consolidation Parameters
Sand Gravel
Soil Description
(N)
(%)
(cm/sec)
(kg/cm2)
Silt
Value (Nc)
IS Symbol
Clay
Limit
Index
Fine
Fine
Content (%)
Permeability
Sample Type
(kg/cm2)
Cv x 10-4
(kg/cm2)
Angle of
Pressure
Mv x 10-2
(cm2/Kg)
Plasticity
(cm2/Sec)
Corrected SPT
Coarse
Coarse
Shrinkage
Index (Cc)
Specific Gravity
IS Classification
Medium
Free Swell Index
Cohesion C
Natural Moisture
Swelling Pressure
Friction (φ°)
Type of Test
Plastic Limit
Liquid Limit
Compression
SPT-14 20.65 48 26 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
51 of 84
SOIL CHARACTERISTICS
Termination
Date of Boring Chainage/Location B.H. No. Depth of Water Table Cordinates (E,N) R.L. Ref. Code
Geotechnical Investigations for Standard Penetration Test and Plate Load Test at
Depth
Project Bharatpur.
01-09-2022 to 02-09-20222 Pushp Vatika Colony BH-03 2.70 m 21.00 m 750225.000 m 3011619.000 m - SR-690_22-23
Grain Size Distribution % wt retained Atterberg Limits % Shear Strength Consolidation Parameters
Sand Gravel
Soil Description
(N)
(%)
(cm/sec)
(kg/cm2)
Silt
Value (Nc)
IS Symbol
Clay
Limit
Index
Fine
Fine
Content (%)
Permeability
Sample Type
(kg/cm2)
Cv x 10-4
(kg/cm2)
Angle of
Pressure
Mv x 10-2
(cm2/Kg)
Plasticity
(cm2/Sec)
Corrected SPT
Coarse
Coarse
Shrinkage
Index (Cc)
Specific Gravity
IS Classification
Medium
Free Swell Index
Cohesion C
Natural Moisture
Swelling Pressure
Friction (φ°)
Type of Test
Plastic Limit
Liquid Limit
Compression
SPT-1 1.50 7 7 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-2 2.65 9 9 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-3 4.15 13 13 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-4 5.65 16 16 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
52 of 84
SPT-5 7.15 18 18 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-6 8.65 21 21 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-7 10.15 25 25 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-8 11.65 23 23 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
UDS* 14.25 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-11 16.15 32 32 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
UDS* 17.25 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-12 17.65 37 37 CI - 24 71 4 1 0 0 0 44 20 24 - - - - - - - - - - - - - - - -
SPT-13 19.15 40 40 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SOIL CHARACTERISTICS
Termination
Date of Boring Chainage/Location B.H. No. Depth of Water Table Cordinates (E,N) R.L. Ref. Code
Geotechnical Investigations for Standard Penetration Test and Plate Load Test at
Depth
Project Bharatpur.
01-09-2022 to 02-09-20222 Pushp Vatika Colony BH-03 2.70 m 21.00 m 750225.000 m 3011619.000 m - SR-690_22-23
Grain Size Distribution % wt retained Atterberg Limits % Shear Strength Consolidation Parameters
Sand Gravel
Soil Description
(N)
(%)
(cm/sec)
(kg/cm2)
Silt
Value (Nc)
IS Symbol
Clay
Limit
Index
Fine
Fine
Content (%)
Permeability
Sample Type
(kg/cm2)
Cv x 10-4
(kg/cm2)
Angle of
Pressure
Mv x 10-2
(cm2/Kg)
Plasticity
(cm2/Sec)
Corrected SPT
Coarse
Coarse
Shrinkage
Index (Cc)
Specific Gravity
IS Classification
Medium
Free Swell Index
Cohesion C
Natural Moisture
Swelling Pressure
Friction (φ°)
Type of Test
Plastic Limit
Liquid Limit
Compression
53 of 84
SOIL CHARACTERISTICS
Termination
Date of Boring Chainage/Location B.H. No. Depth of Water Table Cordinates (E,N) R.L. Ref. Code
Geotechnical Investigations for Standard Penetration Test and Plate Load Test at
Depth
Project Bharatpur.
29-08-2022 to 30-08-2022 Red Cross Circle BH-04 1.35 m 21.00 m 747113.000 m 3014214.000 m - SR-690_22-23
Grain Size Distribution % wt retained Atterberg Limits % Shear Strength Consolidation Parameters
Sand Gravel
Soil Description
(N)
(%)
(cm/sec)
(kg/cm2)
Silt
Value (Nc)
IS Symbol
Clay
Limit
Index
Fine
Fine
Content (%)
Permeability
Sample Type
(kg/cm2)
Cv x 10-4
(kg/cm2)
Angle of
Pressure
Mv x 10-2
(cm2/Kg)
Plasticity
(cm2/Sec)
Corrected SPT
Coarse
Coarse
Shrinkage
Index (Cc)
Specific Gravity
IS Classification
Medium
Free Swell Index
Cohesion C
Natural Moisture
Swelling Pressure
Friction (φ°)
Type of Test
Plastic Limit
Liquid Limit
Compression
SPT-3 4.15 7 7 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-4 5.65 10 10 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
54 of 84
Greyish to Yellowish,firm, stiff to
SPT-5 7.15 13 13 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
very stiff, silty clay of low plasticity
SPT-6 8.65 16 16 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-7 10.15 25 25 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-8 11.65 26 26 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-9 13.15 29 29 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
UDS-4 14.25 - - CI - 23 61 5 0 0 11 0 42 21 21 - 1.99 24.90 1.59 2.72 UUT 1.25 5.00 - - - 0.71 - - - 0.1322
SPT-10 14.65 28 28 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Brownish to yellowish, very stiff to
hard, silty clay of medium plasticity
SPT-11 16.15 33 33 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
UDS* 17.25 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-12 17.65 37 37 CI - 15 67 6 0 0 12 0 42 23 19 - - - - - - - - - - - - - - - -
SPT-13 19.15 41 41 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SOIL CHARACTERISTICS
Termination
Date of Boring Chainage/Location B.H. No. Depth of Water Table Cordinates (E,N) R.L. Ref. Code
Geotechnical Investigations for Standard Penetration Test and Plate Load Test at
Depth
Project Bharatpur.
29-08-2022 to 30-08-2022 Red Cross Circle BH-04 1.35 m 21.00 m 747113.000 m 3014214.000 m - SR-690_22-23
Grain Size Distribution % wt retained Atterberg Limits % Shear Strength Consolidation Parameters
Sand Gravel
Soil Description
(N)
(%)
(cm/sec)
(kg/cm2)
Silt
Value (Nc)
IS Symbol
Clay
Limit
Index
Fine
Fine
Content (%)
Permeability
Sample Type
(kg/cm2)
Cv x 10-4
(kg/cm2)
Angle of
Pressure
Mv x 10-2
(cm2/Kg)
Plasticity
(cm2/Sec)
Corrected SPT
Coarse
Coarse
Shrinkage
Index (Cc)
Specific Gravity
IS Classification
Medium
Free Swell Index
Cohesion C
Natural Moisture
Swelling Pressure
Friction (φ°)
Type of Test
Plastic Limit
Liquid Limit
Compression
55 of 84
SOIL CHARACTERISTICS
Termination
Date of Boring Chainage/Location B.H. No. Depth of Water Table Cordinates (E,N) R.L. Ref. Code
Geotechnical Investigations for Standard Penetration Test and Plate Load Test at
Depth
Project Bharatpur.
Ganesh Temple Kali
27-08-2022 to 28-08-2022 BH-05 2.10 m 21.00 m 746880.000 m 3011936.000 m - SR-690_22-23
Bagichi
Grain Size Distribution % wt retained Atterberg Limits % Shear Strength Consolidation Parameters
Sand Gravel
Soil Description
(N)
(%)
(cm/sec)
(kg/cm2)
Silt
Value (Nc)
IS Symbol
Clay
Limit
Index
Fine
Fine
Content (%)
Permeability
Sample Type
(kg/cm2)
Cv x 10-4
(kg/cm2)
Angle of
Pressure
Mv x 10-2
(cm2/Kg)
Plasticity
(cm2/Sec)
Corrected SPT
Coarse
Coarse
Shrinkage
Index (Cc)
Specific Gravity
IS Classification
Medium
Free Swell Index
Cohesion C
Natural Moisture
Swelling Pressure
Friction (φ°)
Type of Test
Plastic Limit
Liquid Limit
Compression
UDS* 2.25 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-2 2.65 8 8 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-3 4.15 11 11 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-4 5.65 16 16 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
56 of 84
SPT-5 7.15 21 21 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-6 8.65 24 24 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-8 11.65 26 26 - - - - - - - - - - - - - - - - - ; - - - - - - - - - -
SPT-9 13.15 28 28 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-10 14.65 29 29 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-11 16.15 32 32 CI - 14 68 6 1 0 11 0 40 23 17 - - - - - - - - - - - - - - - -
UDS* 17.25 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-12 17.65 36 36 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-13 19.15 44 44 CI - 12 72 4 1 0 11 0 41 23 18 - - - - - - - - - - - - - - - -
SOIL CHARACTERISTICS
Termination
Date of Boring Chainage/Location B.H. No. Depth of Water Table Cordinates (E,N) R.L. Ref. Code
Geotechnical Investigations for Standard Penetration Test and Plate Load Test at
Depth
Project Bharatpur.
Ganesh Temple Kali
27-08-2022 to 28-08-2022 BH-05 2.10 m 21.00 m 746880.000 m 3011936.000 m - SR-690_22-23
Bagichi
Grain Size Distribution % wt retained Atterberg Limits % Shear Strength Consolidation Parameters
Sand Gravel
Soil Description
(N)
(%)
(cm/sec)
(kg/cm2)
Silt
Value (Nc)
IS Symbol
Clay
Limit
Index
Fine
Fine
Content (%)
Permeability
Sample Type
(kg/cm2)
Cv x 10-4
(kg/cm2)
Angle of
Pressure
Mv x 10-2
(cm2/Kg)
Plasticity
(cm2/Sec)
Corrected SPT
Coarse
Coarse
Shrinkage
Index (Cc)
Specific Gravity
IS Classification
Medium
Free Swell Index
Cohesion C
Natural Moisture
Swelling Pressure
Friction (φ°)
Type of Test
Plastic Limit
Liquid Limit
Compression
57 of 84
SOIL CHARACTERISTICS
Termination
Date of Boring Chainage/Location B.H. No. Depth of Water Table Cordinates (E,N) R.L. Ref. Code
Geotechnical Investigations for Standard Penetration Test and Plate Load Test at
Depth
Project Bharatpur.
27-08-2022 to 30-08-2022 Nimda Gate BH-06 1.60 m 21.00 m 746431.000 m 3012112.000 m - SR-690_22-23
Grain Size Distribution % wt retained Atterberg Limits % Shear Strength Consolidation Parameters
Sand Gravel
Soil Description
(N)
(%)
(cm/sec)
(kg/cm2)
Silt
Value (Nc)
IS Symbol
Clay
Limit
Index
Fine
Fine
Content (%)
Permeability
Sample Type
(kg/cm2)
Cv x 10-4
(kg/cm2)
Angle of
Pressure
Mv x 10-2
(cm2/Kg)
Plasticity
(cm2/Sec)
Corrected SPT
Coarse
Coarse
Shrinkage
Index (Cc)
Specific Gravity
IS Classification
Medium
Free Swell Index
Cohesion C
Natural Moisture
Swelling Pressure
Friction (φ°)
Type of Test
Plastic Limit
Liquid Limit
Compression
UDS* 2.25 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-2 2.65 5 5 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-3 4.15 11 11 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
UDS-1 5.25 - - Greyish to yellowish, firm,stiff to CI - 17 65 6 0 0 12 0 41 22 19 - 1.95 27.60 1.53 2.72 UUT 0.65 5 - - - - - - - -
very stiff, hard, silty clay of medium
plasticity
SPT-4 5.65 19 19 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
58 of 84
SPT-5 7.15 22 22 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-6 8.65 24 24 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-7 10.15 33 33 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-8 11.65 36 36 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-9 13.15 41 41 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-11 16.15 49 49 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-12 17.65 50 50 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-13 19.15 43 43 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SOIL CHARACTERISTICS
Termination
Date of Boring Chainage/Location B.H. No. Depth of Water Table Cordinates (E,N) R.L. Ref. Code
Geotechnical Investigations for Standard Penetration Test and Plate Load Test at
Depth
Project Bharatpur.
27-08-2022 to 30-08-2022 Nimda Gate BH-06 1.60 m 21.00 m 746431.000 m 3012112.000 m - SR-690_22-23
Grain Size Distribution % wt retained Atterberg Limits % Shear Strength Consolidation Parameters
Sand Gravel
Soil Description
(N)
(%)
(cm/sec)
(kg/cm2)
Silt
Value (Nc)
IS Symbol
Clay
Limit
Index
Fine
Fine
Content (%)
Permeability
Sample Type
(kg/cm2)
Cv x 10-4
(kg/cm2)
Angle of
Pressure
Mv x 10-2
(cm2/Kg)
Plasticity
(cm2/Sec)
Corrected SPT
Coarse
Coarse
Shrinkage
Index (Cc)
Specific Gravity
IS Classification
Medium
Free Swell Index
Cohesion C
Natural Moisture
Swelling Pressure
Friction (φ°)
Type of Test
Plastic Limit
Liquid Limit
Compression
59 of 84
SOIL CHARACTERISTICS
Termination
Date of Boring Chainage/Location B.H. No. Depth of Water Table Cordinates (E,N) R.L. Ref. Code
Geotechnical Investigations for Standard Penetration Test and Plate Load Test at
Depth
Project Bharatpur.
23-08-2022 to 26-08-2022 Annahi Gate BH-07 1.80 m 21.00 m 745823.000 m 3012491.000 m - SR-690_22-23
Grain Size Distribution % wt retained Atterberg Limits % Shear Strength Consolidation Parameters
Sand Gravel
Soil Description
(N)
(%)
(cm/sec)
(kg/cm2)
Silt
Value (Nc)
IS Symbol
Clay
Limit
Index
Fine
Fine
Content (%)
Permeability
Sample Type
(kg/cm2)
Cv x 10-4
(kg/cm2)
Angle of
Pressure
Mv x 10-2
(cm2/Kg)
Plasticity
(cm2/Sec)
Corrected SPT
Coarse
Coarse
Shrinkage
Index (Cc)
Specific Gravity
IS Classification
Medium
Free Swell Index
Cohesion C
Natural Moisture
Swelling Pressure
Friction (φ°)
Type of Test
Plastic Limit
Liquid Limit
Compression
SPT-2 2.65 4 5 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
UDS* 5.25 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-4 5.65 6 6 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
60 of 84
SPT-5 7.15 9 9 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-6 8.65 12 12 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Greyish to yellowish, firm, stiff to
very stiff, silty clay of low plasticity
SPT-7 10.15 14 14 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-8 11.65 19 19 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-9 13.15 23 23 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-10 14.65 29 29 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-11 16.15 34 34 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-12 17.65 39 23 - - - - - - - - - - - - - - - - - - - - - - - - - - -
SOIL CHARACTERISTICS
Termination
Date of Boring Chainage/Location B.H. No. Depth of Water Table Cordinates (E,N) R.L. Ref. Code
Geotechnical Investigations for Standard Penetration Test and Plate Load Test at
Depth
Project Bharatpur.
23-08-2022 to 26-08-2022 Annahi Gate BH-07 1.80 m 21.00 m 745823.000 m 3012491.000 m - SR-690_22-23
Grain Size Distribution % wt retained Atterberg Limits % Shear Strength Consolidation Parameters
Sand Gravel
Soil Description
(N)
(%)
(cm/sec)
(kg/cm2)
Silt
Value (Nc)
IS Symbol
Clay
Limit
Index
Fine
Fine
Content (%)
Permeability
Sample Type
(kg/cm2)
Cv x 10-4
(kg/cm2)
Angle of
Pressure
Mv x 10-2
(cm2/Kg)
Plasticity
(cm2/Sec)
Corrected SPT
Coarse
Coarse
Shrinkage
Index (Cc)
Specific Gravity
IS Classification
Medium
Free Swell Index
Cohesion C
Natural Moisture
Swelling Pressure
Friction (φ°)
Type of Test
Plastic Limit
Liquid Limit
Compression
SPT-14 20.65 24 24 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
61 of 84
SOIL CHARACTERISTICS
Termination
Date of Boring Chainage/Location B.H. No. Depth of Water Table Cordinates (E,N) R.L. Ref. Code
Depth
Project Geotechnical Investigations for Kumher Gate, Bharatpur (Rajasthan)
08-08-2022 to 10-08-2022 Kumher Gate BH-08 2.00 m 15.00m 745869.000 m 3013096.000 m - SR-690_22-23
3
Grain Size Distribution % wt retained Atterberg Limits % Shear Strength Consolidation Parameters
Sand Gravel
-2
-4
2)
Soil Description
(N)
(%)
2
(cm/sec)
(kg/cm2)
Silt
Value (Nc)
IS Symbol
Clay
Limit
Index
Fine
Fine
Content (%)
Permeability
Sample Type
(kg/cm
Cv x 10
(kg/cm2)
Angle of
Pressure
Mv x 10
(cm /Kg)
Plasticity
(cm2/Sec)
Corrected SPT
Coarse
Coarse
Shrinkage
Index (Cc)
Specific Gravity
IS Classification
Medium
Free Swell Index
Cohesion C
Natural Moisture
Swelling Pressure
Friction (φ°)
Type of Test
Plastic Limit
Liquid Limit
Compression
SPT-1 1.50 5 5 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-2 3.00 9 9 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-3 4.50 12 18 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-4 6.00 14 21 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
62 of 84
SPT-5 7.50 8 8 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-6 9.00 12 12 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-7 10.50 19 19 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-8 12.00 24 24 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-9 13.50 23 23 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
UDS* 14.25 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SPT-10 15.00 32 32 CL - 24 52 10 4 0 10 0 34 20 14 - - - - - - - - - - - - - - - -
Geotechnical Investigations for Standard Penetration Test and Plate Load Test at Bharatpur. SR-690_22-23
Appendix – B2
63 of 84
Ref. Code:-SR-690_22-23
Project Name Geotechnical Investigations for Standard Penetration Test and Plate Load Test at Bharatpur.
CLAY SILT FINE SAND MEDIUM SAND COARSE FINE GRAVEL COARSE
SAND GRAVEL
100
90
80
70
Percent Finer By Weight
60
50
40
30
20
10
64 of 84
Ref. Code:-SR-690_22-23
Project Name Geotechnical Investigations for Standard Penetration Test and Plate Load Test at Bharatpur.
CLAY SILT FINE SAND MEDIUM SAND COARSE FINE GRAVEL COARSE
SAND GRAVEL
100
90
80
70
Percent Finer By Weight
60
50
40
30
20
10
65 of 84
Ref. Code:-SR-690_22-23
Project Name Geotechnical Investigations for Standard Penetration Test and Plate Load Test at Bharatpur.
CLAY SILT FINE SAND MEDIUM SAND COARSE FINE GRAVEL COARSE
SAND GRAVEL
100
90
80
70
Percent Finer By Weight
60
50
40
30
20
10
66 of 84
Ref. Code:-SR-690_22-23
Project Name Geotechnical Investigations for Standard Penetration Test and Plate Load Test at Bharatpur.
CLAY SILT FINE SAND MEDIUM SAND COARSE FINE GRAVEL COARSE
SAND GRAVEL
100
90
80
70
Percent Finer By Weight
60
50
40
30
20
10
67 of 84
Ref. Code:-SR-690_22-23
Project Name Geotechnical Investigations for Standard Penetration Test and Plate Load Test at Bharatpur.
CLAY SILT FINE SAND MEDIUM SAND COARSE FINE GRAVEL COARSE
SAND GRAVEL
100
90
80
70
Percent Finer By Weight
60
50
40
30
20
10
68 of 84
Ref. Code:-SR-690_22-23
Project Name Geotechnical Investigations for Standard Penetration Test and Plate Load Test at Bharatpur.
CLAY SILT FINE SAND MEDIUM SAND COARSE FINE GRAVEL COARSE
SAND GRAVEL
100
90
80
70
Percent Finer By Weight
60
50
40
30
20
10
69 of 84
Ref. Code:-SR-690_22-23
Project Name Geotechnical Investigations for Standard Penetration Test and Plate Load Test at Bharatpur.
CLAY SILT FINE SAND MEDIUM SAND COARSE FINE GRAVEL COARSE
SAND GRAVEL
100
90
80
70
Percent Finer By Weight
60
50
40
30
20
10
70 of 84
Ref. Code:-SR-690_22-23
100
90
80
70
Percent Finer By Weight
60
50
40
30
20
10
71 of 84
“Geotechnical Investigations for Standard Penetration Test and Plate Load Test at Bharatpur.” SR-690_22-23
APPENDIX – C
(ANALYSIS & RECOMENDATION)
Appendix No. ITEMS
CALCULATION FOR COMPUTATION OF LIQUEFACTION
C-1
POTENTIAL
SAMPLE CALCULATION FOR COMPUTATION OF ALLOWABLE
C-2
BEARING CAPACITY OF SUB-STRATA FOR RAFT FOUNDATION
72 of 84
Geotechnical Investigations for Standard Penetration Test and Plate Load Test at Bharatpur. SR-690_22-23
Liquefaction Analysis as per IS: 1893 (Part 1)-2016 & RDSO BS-118
Water Table depth considered for
Location Jagina Gate BH No.:- 1 Liquefiable upto= 11.65m 0.00
analysis (m):-
Stress Stress
Depth Saturate Subme Plastic Moisture Total Effective Critical SPT
Observe Liquid Plastic Fine Reductio Normali
Below d rged ity Content @ Liquefaction Check Overburd Overburd Stress Correct
d SPT Limit Limit Strata Type Content n CHT CHW CSS CRL CBD C60 zation α β (N1)60CS CRRM=7.5 KM Kα Kσ CRRMw FOS Conclusion
G.L. (z) Density Densit Index 100% for Cohesive Strata en Press en (σ'o), Ratio ed
Value 3 3 (%) (%) (%) Coefficie 2 Factor(C
in m (t/m ) y (t/m ) (%) saturation (σo), t/m t/m2 (CSR) (N1)60
nt (rd) N)
2.25 3 1.90 0.90 Cohesionless 55 0.983 4.05 1.80 0.230 0.75 0.986 1.00 0.75 1.05 0.582 1.70 3.0 5.00 1.20 8.56 0.101 1.44 1 1.00 0.145 0.63 Liquefiable
3.00 3 1.90 0.90 Cohesionless 55 0.977 5.48 2.48 0.225 0.75 0.986 1.00 0.80 1.05 0.621 1.70 3.2 5.00 1.20 8.80 0.103 1.44 1 1.00 0.148 0.66 Liquefiable
4.50 4 1.90 0.90 Cohesionless 55 0.966 8.34 3.84 0.218 0.75 0.986 1.00 0.85 1.05 0.660 1.60 4.2 5.00 1.20 10.06 0.114 1.44 1 1.00 0.164 0.75 Liquefiable
6.00 6 1.92 0.92 Cohesionless 55 0.954 11.19 5.19 0.214 0.75 0.986 1.00 0.95 1.05 0.738 1.37 6.1 5.00 1.20 12.29 0.134 1.44 1 1.00 0.193 0.90 Liquefiable
7.50 3 1.92 0.92 Cohesionless 55 0.943 14.07 6.57 0.210 0.75 0.986 1.00 0.95 1.05 0.738 1.22 2.7 5.00 1.20 8.24 0.098 1.44 1 1.00 0.141 0.67 Liquefiable
8.65 4 1.93 0.93 Cohesionless 82 0.934 16.27 7.62 0.207 0.75 0.986 1.00 0.95 1.05 0.738 1.13 3.3 5.00 1.20 9.01 0.105 1.44 1 1.00 0.151 0.73 Liquefiable
10.15 6 1.93 0.93 Cohesionless 82 0.903 19.16 9.01 0.200 0.75 0.986 1.00 1.00 1.05 0.776 1.04 4.9 5.00 1.20 10.83 0.120 1.44 1 1.00 0.174 0.87 Liquefiable
11.65 36 1.98 0.98 Cohesionless 15 0.863 22.06 10.41 0.190 0.75 0.986 1.00 1.00 1.05 0.776 0.97 27.1 2.50 1.05 30.92 NA 1.44 1 1.00 NA >1 Non Liquefiable
13.15 38 1.98 0.98 Cohesionless 15 0.823 25.03 11.88 0.180 0.75 0.986 1.00 1.00 1.05 0.776 0.91 26.8 2.50 1.05 30.58 NA 1.44 1 1.00 NA >1 Non Liquefiable
14.65 21 1.98 0.98 Cohesionless 15 0.783 28.01 13.36 0.171 0.75 0.986 1.00 1.00 1.05 0.776 0.86 14.0 2.50 1.05 17.13 0.182 1.44 1 1.00 0.263 1.54 Non Liquefiable
16.15 36 1.98 0.98 Cohesionless 12 0.743 30.98 14.83 0.161 0.75 0.986 1.00 1.00 1.05 0.776 0.81 22.7 1.55 1.03 24.99 0.292 1.44 1 0.90 0.377 2.34 Non Liquefiable
17.65 31 1.98 0.98 Cohesionless 9 0.703 33.96 16.31 0.152 0.75 0.986 1.00 1.00 1.05 0.776 0.78 18.7 0.56 1.02 19.53 0.210 1.44 1 0.87 0.263 1.73 Non Liquefiable
20.65 55 1.98 0.98 Cohesionless 9 0.623 39.91 19.26 0.134 0.75 0.986 1.00 1.00 1.05 0.776 0.71 30.5 0.56 1.02 31.53 NA 1.44 1 0.82 NA >1 Non Liquefiable
73 of 84
CEG Test House and Research Centre Pvt. Ltd.
Geotechnical Investigations for Standard Penetration Test and Plate Load Test at Bharatpur. SR-690_22-23
Liquefaction Analysis as per IS: 1893 (Part 1)-2016 & RDSO BS-118
Water Table depth considered for
Location Saras Chauraha BH No.:- 2 Liquefiable upto= 2.65m 0.00
analysis (m):-
Stress Stress
Depth Saturate Subme Plastic Moisture Total Effective Critical SPT
Observe Liquid Plastic Fine Reductio Normali
Below d rged ity Content @ Liquefaction Check Overburd Overburd Stress Correct CRRM
d SPT Limit Limit Strata Type Content n CHT CHW CSS CRL CBD C60 zation α β (N1)60CS CRRM=7.5 KM Kα Kσ FOS Conclusion
G.L. (z) Density Densit Index 100% for Cohesive Strata en Press en (σ'o), Ratio ed w
Value 3 3 (%) (%) (%) Coefficie 2 Factor(C
in m (t/m ) y (t/m ) (%) saturation (σo), t/m t/m2 (CSR) (N1)60
nt (rd) N)
1.50 5 1.92 0.92 27.00 19.00 8.00 31.46 Cohesive Liquefiable 54 0.989 2.70 1.20 0.231 0.75 0.986 1.00 0.75 1.05 0.582 1.70 4.9 5.00 1.20 10.94 0.121 1.44 1 1.00 0.175 0.76 Liquefiable
2.65 7 1.92 0.92 27.00 19.00 8.00 31.46 Cohesive Liquefiable 54 0.980 4.91 2.26 0.222 0.75 0.986 1.00 0.75 1.05 0.582 1.70 6.9 5.00 1.20 13.31 0.144 1.44 1 1.00 0.207 1.00 Non Liquefiable
4.15 13 1.92 0.92 27.00 19.00 8.00 31.46 Cohesive Liquefiable 54 0.968 7.79 3.64 0.216 0.75 0.986 1.00 0.85 1.05 0.660 1.64 14.1 5.00 1.20 21.90 0.241 1.44 1 1.00 0.347 1.61 Non Liquefiable
5.65 12 1.95 0.95 Cohesionless 27 0.957 10.66 5.01 0.212 0.75 0.986 1.00 0.85 1.05 0.660 1.40 11.1 4.48 1.13 16.99 0.181 1.44 1 1.00 0.261 1.23 Non Liquefiable
7.15 15 1.95 0.95 Cohesionless 27 0.945 13.59 6.44 0.207 0.75 0.986 1.00 0.95 1.05 0.738 1.23 13.6 4.48 1.13 19.90 0.214 1.44 1 1.00 0.309 1.49 Non Liquefiable
8.65 21 1.99 0.99 41.00 21.00 20.00 26.93 Cohesive Non-Liquefiable - 0.934 16.52 7.87 0.204 0.75 0.986 1.00 0.95 1.05 0.738 - - - - - - - - - - >1 Non Liquefiable
10.15 23 1.99 0.99 41.00 21.00 20.00 26.93 Cohesive Non-Liquefiable - 0.903 19.51 9.36 0.196 0.75 0.986 1.00 1.00 1.05 0.776 - - - - - - - - - - >1 Non Liquefiable
11.65 27 1.99 0.99 41.00 21.00 20.00 26.93 Cohesive Non-Liquefiable - 0.863 22.50 10.85 0.186 0.75 0.986 1.00 1.00 1.05 0.776 - - - - - - - - - - >1 Non Liquefiable
13.15 28 1.99 0.99 41.00 21.00 20.00 26.93 Cohesive Non-Liquefiable - 0.823 25.49 12.34 0.177 0.75 0.986 1.00 1.00 1.05 0.776 - - - - - - - - - - >1 Non Liquefiable
14.65 32 2.01 1.01 42.00 20.00 22.00 26.13 Cohesive Non-Liquefiable - 0.783 28.48 13.83 0.168 0.75 0.986 1.00 1.00 1.05 0.776 - - - - - - - - - - >1 Non Liquefiable
16.15 34 2.01 1.01 42.00 20.00 22.00 26.13 Cohesive Non-Liquefiable - 0.743 31.49 15.34 0.159 0.75 0.986 1.00 1.00 1.05 0.776 - - - - - - - - - - >1 Non Liquefiable
17.65 33 2.01 1.01 42.00 20.00 22.00 26.13 Cohesive Non-Liquefiable - 0.703 34.49 16.84 0.150 0.75 0.986 1.00 1.00 1.05 0.776 - - - - - - - - - - >1 Non Liquefiable
19.15 35 1.97 0.97 Cohesionless 22 0.663 37.50 18.35 0.141 0.75 0.986 1.00 1.00 1.05 0.776 0.73 19.9 3.93 1.09 25.63 0.305 1.44 1 0.84 0.368 2.61 Non Liquefiable
20.65 48 1.97 0.97 Cohesionless 22 0.623 40.46 19.81 0.132 0.75 0.986 1.00 1.00 1.05 0.776 0.70 26.2 3.93 1.09 32.58 NA 1.44 1 0.82 NA >1 Non Liquefiable
74 of 84
CEG Test House and Research Centre Pvt. Ltd.
Geotechnical Investigations for Standard Penetration Test and Plate Load Test at Bharatpur. SR-690_22-23
Liquefaction Analysis as per IS: 1893 (Part 1)-2016 & RDSO BS-118
Water Table depth considered for
Location Pushp Vatika Colony BH No.:- 3 Liquefiable upto= NL 0.00
analysis (m):-
Stress Stress
Depth Saturate Subme Plastic Moisture Total Effective Critical SPT
Observe Liquid Plastic Fine Reductio Normali
Below d rged ity Content @ Liquefaction Check Overburd Overburd Stress Correct CRRM
d SPT Limit Limit Strata Type Content n CHT CHW CSS CRL CBD C60 zation α β (N1)60CS CRRM=7.5 KM Kα Kσ FOS Conclusion
G.L. (z) Density Densit Index 100% for Cohesive Strata en Press en (σ'o), Ratio ed w
Value 3 3 (%) (%) (%) Coefficie 2 Factor(C
in m (t/m ) y (t/m ) (%) saturation (σo), t/m t/m2 (CSR) (N1)60
nt (rd) N)
1.50 7 1.94 0.94 41.00 20.00 21.00 30.35 Cohesive Non-Liquefiable - 0.989 2.70 1.20 0.231 0.75 0.986 1.00 0.75 1.05 0.582 - - - - - - - - - - >1 Non Liquefiable
2.65 9 1.94 0.94 41.00 20.00 21.00 30.35 Cohesive Non-Liquefiable - 0.980 4.93 2.28 0.220 0.75 0.986 1.00 0.75 1.05 0.582 - - - - - - - - - - >1 Non Liquefiable
4.15 13 1.97 0.97 31.00 20.00 11.00 27.90 Cohesive Liquefiable 69 0.968 7.85 3.70 0.214 0.75 0.986 1.00 0.85 1.05 0.660 1.63 14.0 5.00 1.20 21.76 0.239 1.44 1 1.00 0.344 1.61 Non Liquefiable
5.65 16 1.97 0.97 31.00 20.00 11.00 27.90 Cohesive Liquefiable 69 0.957 10.80 5.15 0.209 0.75 0.986 1.00 0.85 1.05 0.660 1.38 14.6 5.00 1.20 22.47 0.249 1.44 1 1.00 0.359 1.72 Non Liquefiable
7.15 18 1.99 0.99 42.00 20.00 22.00 27.34 Cohesive Non-Liquefiable - 0.945 13.76 6.61 0.205 0.75 0.986 1.00 0.95 1.05 0.738 - - - - - - - - - - >1 Non Liquefiable
8.65 21 1.99 0.99 42.00 20.00 22.00 27.34 Cohesive Non-Liquefiable - 0.934 16.74 8.09 0.201 0.75 0.986 1.00 0.95 1.05 0.738 - - - - - - - - - - >1 Non Liquefiable
10.15 25 1.99 0.99 42.00 20.00 22.00 27.34 Cohesive Non-Liquefiable - 0.903 19.72 9.57 0.194 0.75 0.986 1.00 1.00 1.05 0.776 - - - - - - - - - - >1 Non Liquefiable
11.65 23 1.99 0.99 42.00 22.00 20.00 26.79 Cohesive Non-Liquefiable - 0.863 22.69 11.04 0.184 0.75 0.986 1.00 1.00 1.05 0.776 - - - - - - - - - - >1 Non Liquefiable
13.15 28 1.99 0.99 42.00 22.00 20.00 26.79 Cohesive Non-Liquefiable - 0.823 25.68 12.53 0.175 0.75 0.986 1.00 1.00 1.05 0.776 - - - - - - - - - - >1 Non Liquefiable
14.65 31 2.01 1.01 43.00 22.00 21.00 25.74 Cohesive Non-Liquefiable - 0.783 28.67 14.02 0.167 0.75 0.986 1.00 1.00 1.05 0.776 - - - - - - - - - - >1 Non Liquefiable
16.15 32 2.01 1.01 43.00 22.00 21.00 25.74 Cohesive Non-Liquefiable - 0.743 31.68 15.53 0.158 0.75 0.986 1.00 1.00 1.05 0.776 - - - - - - - - - - >1 Non Liquefiable
17.65 37 2.01 1.01 44.00 20.00 24.00 25.74 Cohesive Non-Liquefiable - 0.703 34.70 17.05 0.149 0.75 0.986 1.00 1.00 1.05 0.776 - - - - - - - - - - >1 Non Liquefiable
19.15 40 2.01 1.01 44.00 20.00 24.00 25.74 Cohesive Non-Liquefiable - 0.663 37.72 18.57 0.140 0.75 0.986 1.00 1.00 1.05 0.776 - - - - - - - - - - >1 Non Liquefiable
20.65 44 1.97 0.97 27.00 21.00 6.00 27.90 Cohesive Liquefiable 55 0.623 40.74 20.09 0.131 0.75 0.986 1.00 1.00 1.05 0.776 0.70 23.9 5.00 1.20 33.63 NA 1.44 1 0.81 NA >1 Non Liquefiable
75 of 84
CEG Test House and Research Centre Pvt. Ltd.
Geotechnical Investigations for Standard Penetration Test and Plate Load Test at Bharatpur. SR-690_22-23
Liquefaction Analysis as per IS: 1893 (Part 1)-2016 & RDSO BS-118
Water Table depth considered for
Location Red Cross Circle BH No.:- 4 Liquefiable upto= 4.15m 0.00
analysis (m):-
Stress Stress
Depth Saturate Subme Plastic Moisture Total Effective Critical SPT
Observe Liquid Plastic Fine Reductio Normali
Below d rged ity Content @ Liquefaction Check Overburd Overburd Stress Correct CRRM
d SPT Limit Limit Strata Type Content n CHT CHW CSS CRL CBD C60 zation α β (N1)60CS CRRM=7.5 KM Kα Kσ FOS Conclusion
G.L. (z) Density Densit Index 100% for Cohesive Strata en Press en (σ'o), Ratio ed w
Value 3 3 (%) (%) (%) Coefficie 2 Factor(C
in m (t/m ) y (t/m ) (%) saturation (σo), t/m t/m2 (CSR) (N1)60
nt (rd) N)
1.50 4 1.92 0.92 43.00 20.00 23.00 32.20 Cohesive Non-Liquefiable - 0.989 2.70 1.20 0.231 0.75 0.986 1.00 0.75 1.05 0.582 - - - - - - - - - - >1 Non Liquefiable
2.65 5 1.92 0.92 33.00 21.00 12.00 30.85 Cohesive Liquefiable 57 0.980 4.90 2.25 0.222 0.75 0.986 1.00 0.75 1.05 0.582 1.70 4.9 5.00 1.20 10.94 0.121 1.44 1 1.00 0.175 0.79 Liquefiable
4.15 7 1.92 0.92 33.00 21.00 12.00 30.85 Cohesive Liquefiable 57 0.968 7.79 3.64 0.216 0.75 0.986 1.00 0.85 1.05 0.660 1.64 7.6 5.00 1.20 14.10 0.151 1.44 1 1.00 0.218 1.01 Non Liquefiable
5.65 10 1.95 0.95 33.00 21.00 12.00 29.19 Cohesive Liquefiable 57 0.957 10.68 5.03 0.211 0.75 0.986 1.00 0.85 1.05 0.660 1.40 9.2 5.00 1.20 16.06 0.171 1.44 1 1.00 0.246 1.17 Non Liquefiable
7.15 13 1.95 0.95 33.00 21.00 12.00 29.19 Cohesive Liquefiable 57 0.945 13.60 6.45 0.207 0.75 0.986 1.00 0.95 1.05 0.738 1.23 11.8 5.00 1.20 19.18 0.205 1.44 1 1.00 0.296 1.43 Non Liquefiable
8.65 16 1.96 0.96 31.00 20.00 11.00 28.32 Cohesive Liquefiable 67 0.934 16.53 7.88 0.204 0.75 0.986 1.00 0.95 1.05 0.738 1.12 13.2 5.00 1.20 20.79 0.226 1.44 1 1.00 0.325 1.60 Non Liquefiable
10.15 25 1.96 0.96 31.00 20.00 11.00 28.32 Cohesive Liquefiable 67 0.903 19.47 9.32 0.196 0.75 0.986 1.00 1.00 1.05 0.776 1.03 19.9 5.00 1.20 28.88 0.405 1.44 1 1.00 0.583 2.97 Non Liquefiable
11.65 26 2.01 1.01 42.00 21.00 21.00 26.13 Cohesive Non-Liquefiable - 0.863 22.42 10.77 0.187 0.75 0.986 1.00 1.00 1.05 0.776 - - - - - - - - - - >1 Non Liquefiable
13.15 29 2.01 1.01 42.00 21.00 21.00 26.13 Cohesive Non-Liquefiable - 0.823 25.43 12.28 0.177 0.75 0.986 1.00 1.00 1.05 0.776 - - - - - - - - - - >1 Non Liquefiable
14.65 28 2.01 1.01 42.00 21.00 21.00 26.13 Cohesive Non-Liquefiable - 0.783 28.43 13.78 0.168 0.75 0.986 1.00 1.00 1.05 0.776 - - - - - - - - - - >1 Non Liquefiable
16.15 33 2.01 1.01 42.00 21.00 21.00 26.13 Cohesive Non-Liquefiable - 0.743 31.44 15.29 0.159 0.75 0.986 1.00 1.00 1.05 0.776 - - - - - - - - - - >1 Non Liquefiable
17.65 37 2.01 1.01 42.00 23.00 19.00 26.13 Cohesive Non-Liquefiable - 0.703 34.45 16.80 0.150 0.75 0.986 1.00 1.00 1.05 0.776 - - - - - - - - - - >1 Non Liquefiable
19.15 41 2.01 1.01 42.00 23.00 19.00 26.13 Cohesive Non-Liquefiable - 0.663 37.46 18.31 0.141 0.75 0.986 1.00 1.00 1.05 0.776 - - - - - - - - - - >1 Non Liquefiable
20.65 52 2.01 1.01 44.00 23.00 21.00 26.13 Cohesive Non-Liquefiable - 0.623 40.47 19.82 0.132 0.75 0.986 1.00 1.00 1.05 0.776 - - - - - - - - - - >1 Non Liquefiable
76 of 84
CEG Test House and Research Centre Pvt. Ltd.
Geotechnical Investigations for Standard Penetration Test and Plate Load Test at Bharatpur. SR-690_22-23
Liquefaction Analysis as per IS: 1893 (Part 1)-2016 & RDSO BS-118
Water Table depth considered for
Location Ganesh Temple BH No.:- 5 Liquefiable upto= NL 0.00
analysis (m):-
Stress Stress
Depth Saturate Subme Plastic Moisture Total Effective Critical SPT
Observe Liquid Plastic Fine Reductio Normali
Below d rged ity Content @ Liquefaction Check Overburd Overburd Stress Correct CRRM
d SPT Limit Limit Strata Type Content n CHT CHW CSS CRL CBD C60 zation α β (N1)60CS CRRM=7.5 KM Kα Kσ FOS Conclusion
G.L. (z) Density Densit Index 100% for Cohesive Strata en Press en (σ'o), Ratio ed w
Value 3 3 (%) (%) (%) Coefficie 2 Factor(C
in m (t/m ) y (t/m ) (%) saturation (σo), t/m t/m2 (CSR) (N1)60
nt (rd) N)
1.50 6 1.92 0.92 43.00 22.00 21.00 31.73 Cohesive Non-Liquefiable - 0.989 2.70 1.20 0.231 0.75 0.986 1.00 0.75 1.05 0.582 - - - - - - - - - - >1 Non Liquefiable
2.65 8 1.92 0.92 43.00 22.00 21.00 31.73 Cohesive Non-Liquefiable - 0.980 4.91 2.26 0.221 0.75 0.986 1.00 0.75 1.05 0.582 - - - - - - - - - - >1 Non Liquefiable
4.15 11 1.92 0.92 43.00 22.00 21.00 31.73 Cohesive Non-Liquefiable - 0.968 7.80 3.65 0.215 0.75 0.986 1.00 0.85 1.05 0.660 - - - - - - - - - - >1 Non Liquefiable
5.65 16 1.97 0.97 42.00 20.00 22.00 28.17 Cohesive Non-Liquefiable - 0.957 10.68 5.03 0.211 0.75 0.986 1.00 0.85 1.05 0.660 - - - - - - - - - - >1 Non Liquefiable
7.15 21 1.97 0.97 42.00 20.00 22.00 28.17 Cohesive Non-Liquefiable - 0.945 13.64 6.49 0.207 0.75 0.986 1.00 0.95 1.05 0.738 - - - - - - - - - - >1 Non Liquefiable
8.65 24 1.99 0.99 42.00 22.00 22.00 27.06 Cohesive Non-Liquefiable - 0.934 16.60 7.95 0.203 0.75 0.986 1.00 0.95 1.05 0.738 - - - - - - - - - - >1 Non Liquefiable
10.15 27 1.99 0.99 42.00 22.00 22.00 27.06 Cohesive Non-Liquefiable - 0.903 19.60 9.45 0.195 0.75 0.986 1.00 1.00 1.05 0.776 - - - - - - - - - - >1 Non Liquefiable
11.65 26 2.00 1.00 40.00 21.00 19.00 26.39 Cohesive Non-Liquefiable - 0.863 22.59 10.94 0.185 0.75 0.986 1.00 1.00 1.05 0.776 - - - - - - - - - - >1 Non Liquefiable
13.15 28 2.00 1.00 40.00 21.00 19.00 26.39 Cohesive Non-Liquefiable - 0.823 25.58 12.43 0.176 0.75 0.986 1.00 1.00 1.05 0.776 - - - - - - - - - - >1 Non Liquefiable
14.65 29 2.00 1.00 41.00 22.00 19.00 25.99 Cohesive Non-Liquefiable - 0.783 28.58 13.93 0.167 0.75 0.986 1.00 1.00 1.05 0.776 - - - - - - - - - - >1 Non Liquefiable
16.15 32 2.00 1.00 40.00 23.00 17.00 25.99 Cohesive Non-Liquefiable - 0.743 31.58 15.43 0.158 0.75 0.986 1.00 1.00 1.05 0.776 - - - - - - - - - - >1 Non Liquefiable
17.65 36 2.00 1.00 40.00 23.00 17.00 25.99 Cohesive Non-Liquefiable - 0.703 34.59 16.94 0.149 0.75 0.986 1.00 1.00 1.05 0.776 - - - - - - - - - - >1 Non Liquefiable
19.15 44 2.00 1.00 41.00 23.00 18.00 25.99 Cohesive Non-Liquefiable - 0.663 37.59 18.44 0.140 0.75 0.986 1.00 1.00 1.05 0.776 - - - - - - - - - - >1 Non Liquefiable
20.65 49 2.00 1.00 41.00 23.00 18.00 25.99 Cohesive Non-Liquefiable - 0.623 40.60 19.95 0.132 0.75 0.986 1.00 1.00 1.05 0.776 - - - - - - - - - - >1 Non Liquefiable
77 of 84
CEG Test House and Research Centre Pvt. Ltd.
Geotechnical Investigations for Standard Penetration Test and Plate Load Test at Bharatpur. SR-690_22-23
Liquefaction Analysis as per IS: 1893 (Part 1)-2016 & RDSO BS-118
Water Table depth considered for
Location Nimda Gate BH No.:- 6 Liquefiable upto= NL 0.00
analysis (m):-
Stress Stress
Depth Saturate Subme Plastic Moisture Total Effective Critical SPT
Observe Liquid Plastic Fine Reductio Normali
Below d rged ity Content @ Liquefaction Check Overburd Overburd Stress Correct CRRM
d SPT Limit Limit Strata Type Content n CHT CHW CSS CRL CBD C60 zation α β (N1)60CS CRRM=7.5 KM Kα Kσ FOS Conclusion
G.L. (z) Density Densit Index 100% for Cohesive Strata en Press en (σ'o), Ratio ed w
Value 3 3 (%) (%) (%) Coefficie 2 Factor(C
in m (t/m ) y (t/m ) (%) saturation (σo), t/m t/m2 (CSR) (N1)60
nt (rd) N)
1.50 4 1.91 0.91 40.00 20.00 20.00 32.68 Cohesive Non-Liquefiable - 0.989 2.70 1.20 0.231 0.75 0.986 1.00 0.75 1.05 0.582 - - - - - - - - - - >1 Non Liquefiable
2.65 5 1.91 0.91 40.00 20.00 20.00 32.68 Cohesive Non-Liquefiable - 0.980 4.90 2.25 0.222 0.75 0.986 1.00 0.75 1.05 0.582 - - - - - - - - - - >1 Non Liquefiable
4.15 11 1.91 0.91 40.00 20.00 20.00 32.68 Cohesive Non-Liquefiable - 0.968 7.76 3.61 0.216 0.75 0.986 1.00 0.85 1.05 0.660 - - - - - - - - - - >1 Non Liquefiable
5.65 19 1.97 0.97 41.00 22.00 19.00 28.59 Cohesive Non-Liquefiable - 0.957 10.63 4.98 0.212 0.75 0.986 1.00 0.85 1.05 0.660 - - - - - - - - - - >1 Non Liquefiable
7.15 22 1.97 0.97 41.00 22.00 19.00 28.59 Cohesive Non-Liquefiable - 0.945 13.58 6.43 0.208 0.75 0.986 1.00 0.95 1.05 0.738 - - - - - - - - - - >1 Non Liquefiable
8.65 24 1.99 0.99 40.00 24.00 16.00 27.06 Cohesive Non-Liquefiable - 0.934 16.53 7.88 0.204 0.75 0.986 1.00 0.95 1.05 0.738 - - - - - - - - - - >1 Non Liquefiable
10.15 33 1.99 0.99 40.00 24.00 16.00 27.06 Cohesive Non-Liquefiable - 0.903 19.52 9.37 0.196 0.75 0.986 1.00 1.00 1.05 0.776 - - - - - - - - - - >1 Non Liquefiable
11.65 36 2.02 1.02 32.00 20.00 12.00 24.17 Cohesive Non-Liquefiable - 0.863 22.52 10.87 0.186 0.75 0.986 1.00 1.00 1.05 0.776 - - - - - - - - - - >1 Non Liquefiable
13.15 41 2.02 1.02 32.00 20.00 12.00 24.17 Cohesive Non-Liquefiable - 0.823 25.55 12.40 0.176 0.75 0.986 1.00 1.00 1.05 0.776 - - - - - - - - - - >1 Non Liquefiable
14.65 47 2.04 1.04 30.00 22.00 8.00 23.57 Cohesive Non-Liquefiable - 0.783 28.59 13.94 0.167 0.75 0.986 1.00 1.00 1.05 0.776 - - - - - - - - - - >1 Non Liquefiable
16.15 49 2.04 1.04 30.00 22.00 8.00 23.57 Cohesive Non-Liquefiable - 0.743 31.65 15.50 0.158 0.75 0.986 1.00 1.00 1.05 0.776 - - - - - - - - - - >1 Non Liquefiable
17.65 50 2.04 1.04 31.00 21.00 10.00 23.57 Cohesive Non-Liquefiable - 0.703 34.70 17.05 0.149 0.75 0.986 1.00 1.00 1.05 0.776 - - - - - - - - - - >1 Non Liquefiable
19.15 43 2.04 1.04 31.00 21.00 10.00 23.57 Cohesive Non-Liquefiable - 0.663 37.76 18.61 0.140 0.75 0.986 1.00 1.00 1.05 0.776 - - - - - - - - - - >1 Non Liquefiable
20.65 38 2.04 1.04 33.00 24.00 9.00 23.57 Cohesive Non-Liquefiable - 0.623 40.82 20.17 0.131 0.75 0.986 1.00 1.00 1.05 0.776 - - - - - - - - - - >1 Non Liquefiable
78 of 84
CEG Test House and Research Centre Pvt. Ltd.
Geotechnical Investigations for Standard Penetration Test and Plate Load Test at Bharatpur. SR-690_22-23
Liquefaction Analysis as per IS: 1893 (Part 1)-2016 & RDSO BS-118
Water Table depth considered for
Location Annahi Gate BH No.:- 7 Liquefiable upto= 7.15m 0.00
analysis (m):-
Stress Stress
Depth Saturate Subme Plastic Moisture Total Effective Critical SPT
Observe Liquid Plastic Fine Reductio Normali
Below d rged ity Content @ Liquefaction Check Overburd Overburd Stress Correct CRRM
d SPT Limit Limit Strata Type Content n CHT CHW CSS CRL CBD C60 zation α β (N1)60CS CRRM=7.5 KM Kα Kσ FOS Conclusion
G.L. (z) Density Densit Index 100% for Cohesive Strata en Press en (σ'o), Ratio ed w
Value 3 3 (%) (%) (%) Coefficie 2 Factor(C
in m (t/m ) y (t/m ) (%) saturation (σo), t/m t/m2 (CSR) (N1)60
nt (rd) N)
1.50 4 1.89 0.89 Cohesionless 18 0.989 2.70 1.20 0.231 0.75 0.986 1.00 0.75 1.05 0.582 1.70 4.0 3.23 1.07 7.46 0.091 1.44 1 1.00 0.132 0.57 Liquefiable
2.65 4 1.89 0.89 Cohesionless 18 0.980 4.87 2.22 0.223 0.75 0.986 1.00 0.75 1.05 0.582 1.70 4.0 3.23 1.07 7.46 0.091 1.44 1 1.00 0.132 0.59 Liquefiable
4.15 5 1.90 0.90 31.00 20.00 11.00 32.27 Cohesive Liquefiable 60 0.968 7.71 3.56 0.218 0.75 0.986 1.00 0.85 1.05 0.660 1.66 5.5 5.00 1.20 11.57 0.127 1.44 1 1.00 0.183 0.84 Liquefiable
5.65 6 1.90 0.90 31.00 20.00 11.00 32.27 Cohesive Liquefiable 60 0.957 10.57 4.92 0.214 0.75 0.986 1.00 0.85 1.05 0.660 1.41 5.6 5.00 1.20 11.71 0.128 1.44 1 1.00 0.185 0.87 Liquefiable
7.15 9 1.90 0.90 31.00 20.00 11.00 32.27 Cohesive Liquefiable 60 0.945 13.42 6.27 0.210 0.75 0.986 1.00 0.95 1.05 0.738 1.25 8.3 5.00 1.20 14.96 0.160 1.44 1 1.00 0.230 1.09 Non Liquefiable
8.65 12 1.95 0.95 30.00 20.00 10.00 29.19 Cohesive Liquefiable 70 0.934 16.28 7.63 0.207 0.75 0.986 1.00 0.95 1.05 0.738 1.13 10.0 5.00 1.20 17.04 0.181 1.44 1 1.00 0.261 1.26 Non Liquefiable
10.15 14 1.95 0.95 30.00 20.00 10.00 29.19 Cohesive Liquefiable 70 0.903 19.21 9.06 0.199 0.75 0.986 1.00 1.00 1.05 0.776 1.04 11.3 5.00 1.20 18.57 0.198 1.44 1 1.00 0.286 1.44 Non Liquefiable
11.65 19 1.96 0.96 30.00 20.00 10.00 28.32 Cohesive Liquefiable 68 0.863 22.13 10.48 0.189 0.75 0.986 1.00 1.00 1.05 0.776 0.97 14.3 5.00 1.20 22.11 0.244 1.44 1 1.00 0.351 1.85 Non Liquefiable
13.15 23 1.96 0.96 30.00 20.00 10.00 28.32 Cohesive Liquefiable 68 0.823 25.08 11.93 0.180 0.75 0.986 1.00 1.00 1.05 0.776 0.91 16.2 5.00 1.20 24.42 0.281 1.44 1 1.00 0.405 2.25 Non Liquefiable
14.65 29 1.99 0.99 30.00 20.00 10.00 26.66 Cohesive Liquefiable 78 0.783 28.02 13.37 0.171 0.75 0.986 1.00 1.00 1.05 0.776 0.86 19.3 5.00 1.20 28.13 0.374 1.44 1 1.00 0.539 3.16 Non Liquefiable
16.15 34 1.98 0.98 26.00 20.00 6.00 26.10 Cohesive Liquefiable 52 0.743 31.01 14.86 0.161 0.75 0.986 1.00 1.00 1.05 0.776 0.81 21.4 5.00 1.20 30.73 NA 1.44 1 0.90 NA >1 Non Liquefiable
17.65 39 1.98 0.98 26.00 20.00 6.00 26.10 Cohesive Liquefiable 52 0.703 33.98 16.33 0.152 0.75 0.986 1.00 1.00 1.05 0.776 0.77 23.5 5.00 1.20 33.15 NA 1.44 1 0.87 NA >1 Non Liquefiable
19.15 32 2.02 1.02 31.00 21.00 10.00 24.55 Cohesive Non-Liquefiable - 0.663 36.94 17.79 0.143 0.75 0.986 1.00 1.00 1.05 0.776 - - - - - - - - - - >1 Non Liquefiable
20.65 24 2.02 1.02 31.00 21.00 10.00 24.55 Cohesive Non-Liquefiable - 0.623 39.97 19.32 0.134 0.75 0.986 1.00 1.00 1.05 0.776 - - - - - - - - - - >1 Non Liquefiable
79 of 84
CEG Test House and Research Centre Pvt. Ltd.
Geotechnical Investigations for Standard Penetration Test and Plate Load Test at Bharatpur. SR-690_22-23
Liquefaction Analysis as per IS: 1893 (Part 1)-2016 & RDSO BS-118
Water Table depth considered for
Location Kumher Gate BH No.:- 8 Liquefiable upto= 3.00m 0.00
analysis (m):-
Stress Stress
Depth Saturate Subme Plastic Moisture Total Effective Critical SPT
Observe Liquid Plastic Fine Reductio Normali
Below d rged ity Content @ Liquefaction Check Overburd Overburd Stress Correct CRRM
d SPT Limit Limit Strata Type Content n CHT CHW CSS CRL CBD C60 zation α β (N1)60CS CRRM=7.5 KM Kα Kσ FOS Conclusion
G.L. (z) Density Densit Index 100% for Cohesive Strata en Press en (σ'o), Ratio ed w
Value 3 3 (%) (%) (%) Coefficie 2 Factor(C
in m (t/m ) y (t/m ) (%) saturation (σo), t/m t/m2 (CSR) (N1)60
nt (rd) N)
1.50 5 1.94 0.94 32.00 21.00 11.00 29.21 Cohesive Liquefiable 67 0.989 2.70 1.20 0.231 0.75 0.986 1.00 0.75 1.05 0.582 1.70 4.9 5.00 1.20 10.94 0.121 1.44 1 1.00 0.175 0.76 Liquefiable
3.00 9 1.94 0.94 32.00 21.00 11.00 29.21 Cohesive Liquefiable 67 0.977 5.61 2.61 0.219 0.75 0.986 1.00 0.80 1.05 0.621 1.70 9.5 5.00 1.20 16.40 0.174 1.44 1 1.00 0.252 1.15 Non Liquefiable
4.50 12 1.99 0.99 Cohesionless 22 0.966 8.51 4.01 0.213 0.75 0.986 1.00 0.85 1.05 0.660 1.56 12.4 3.93 1.09 17.45 0.186 1.44 1 1.00 0.268 1.26 Non Liquefiable
6.00 14 1.99 0.99 Cohesionless 22 0.954 11.50 5.50 0.208 0.75 0.986 1.00 0.95 1.05 0.738 1.34 13.8 3.93 1.09 19.00 0.203 1.44 1 1.00 0.293 1.41 Non Liquefiable
7.50 8 1.95 0.95 34.00 20.00 14.00 28.48 Cohesive Non-Liquefiable - 0.943 14.48 6.98 0.203 0.75 0.986 1.00 0.95 1.05 0.738 - - - - - - - - - - >1 Non Liquefiable
9.00 12 1.95 0.95 34.00 20.00 14.00 28.48 Cohesive Non-Liquefiable - 0.931 17.41 8.41 0.200 0.75 0.986 1.00 0.95 1.05 0.738 - - - - - - - - - - >1 Non Liquefiable
10.50 19 1.95 0.95 34.00 20.00 14.00 28.48 Cohesive Non-Liquefiable - 0.894 20.34 9.84 0.192 0.75 0.986 1.00 1.00 1.05 0.776 - - - - - - - - - - >1 Non Liquefiable
12.00 24 1.98 0.98 33.00 22.00 11.00 26.38 Cohesive Non-Liquefiable - 0.854 23.27 11.27 0.183 0.75 0.986 1.00 1.00 1.05 0.776 - - - - - - - - - - >1 Non Liquefiable
13.50 23 1.98 0.98 33.00 22.00 11.00 26.38 Cohesive Non-Liquefiable - 0.814 26.24 12.74 0.174 0.75 0.986 1.00 1.00 1.05 0.776 - - - - - - - - - - >1 Non Liquefiable
15.00 32 1.98 0.98 34.00 20.00 14.00 26.38 Cohesive Non-Liquefiable - 0.774 29.22 14.22 0.165 0.75 0.986 1.00 1.00 1.05 0.776 - - - - - - - - - - >1 Non Liquefiable
80 of 84
CEG Test House and Research Centre Pvt. Ltd.
Geotechnical Investigations for Standard Penetration Test and Plate Load Test at Bharatpur. SR-690_22-23
BH No. 1
Type of footing
1 Continuous Strip
2 Rectangular Rectangular 2
3 Square
4 Circular
o
Angle of internal friction (f ) 25.00
2
Cohesion (c in t/m ) 0.50
Void ratio (e), e = (G.γw/γd)-1 0.70
o
Direction of load with vertical ( ) 0.00
3
Density of foundation soil (t/m ) γbulk 1.82
Depth of water table(m) 0.00
Factor of safety 2.50
S.no. Depth (m) of footing (Df) below EGL Width (m) Length (m)
1 2.50 15.00 40.00
2 3.00 15.00 40.00
3 3.50 15.00 40.00
4 4.00 15.00 40.00
5 4.50 15.00 40.00
6 5.00 15.00 40.00
SHEAR FAILURE CRITERIA
Assumptions and formula used in calculation as per IS:6403-1981 are given below -
NOTE: The type of failure used for bearing capacity analysis depends upon the value of void ratio (see IS
6403 : 1981, Page No. 9, Table No. 3).
The ultimate net bearing capacity in case of general shear failure is given by (from IS 6403 : 1981, page
No. 8)
qd = c Nc sc dc ic + q (Nq-1) sq dq iq + (1/2) B g Ng sg dg ig W'
The ultimate net bearing capacity in case of local shear failure is given by (from IS 6403 : 1981, page No.
8)
q'd = (2/3) c N'c sc dc ic + q (N'q-1) sq dq iq + (1/2) B g N'g sg dg ig W'
Where,
dc = 1+ 0.2 (Df/B)*SQRT(Nf )
o
dq = dg = 1 for f <10 (from IS 6403 : 1981, page No. 9)
o
dq = dg = 1 + 0.1 (Df/B)*SQRT(Nf ) for f >10
2
Nf = tan (p/4 +f/2)
f' is friction angle for local shear failure = tan-1 ( 0.67 tanf )
OUTPUT
The computer aided results for shear failure criteria are tabulated below. The results are
interpolated values of bearing capacity obtained from general and local shear failure
criteria.
81 of 84
Geotechnical Investigations for Standard Penetration Test and Plate Load Test at Bharatpur. SR-690_22-23
Bearing capacity factors : (from IS 6403 : 1981, page No. 8, Table No. 1)
2
ic = (1-a / 90) 2 iq = (1-a / 90) 2 ig = (1- a / f)
1.00 1.00 1.00
2
S.no. Depth(m) Width(m) Length (m) SBC in (t/m )
General shear Local shear Actual
1 2.50 15.00 40.00 39.43 14.33 20.76
2 3.00 15.00 40.00 41.42 15.13 21.86
3 3.50 15.00 40.00 43.43 15.94 22.98
4 4.00 15.00 40.00 45.45 16.76 24.10
5 4.50 15.00 40.00 47.50 17.58 25.24
6 5.00 15.00 40.00 49.56 18.41 26.38
NOTE: The type of failure used for bearing capacity analysis depends upon the value of void ratio
(see IS 6403 : 1981, Page No. 9, Table No. 3).
82 of 84
Geotechnical Investigations for Standard Penetration Test and Plate Load Test at Bharatpur. SR-690_22-23
Settlement in Non-
Dispersed Breadth
Height of layer(m)
Elastic Settlement
Geological Factor
Dispersed Length
Depth below FGL
Settlement (mm)
Average N-Value
Total Settlement
Depth (kg/Cm2)
Modulus of Soil
Layer Thickness
Poission's Ratio
Corrected Total
level (Kg/Cm2)
Rigidity Factor
Mvc (Cm /Kg)
Cohesive Soil
Depth Factor
Settlement
(Kg/Cm )
Breadth
Si (mm)
2
Length
(mm)
(mm)
(mm)
Layer
2
From
(m)
(m)
(m)
(m)
(m)
(m)
(m)
(l )
To
Si
Layer 1 2.50 8.65 6.15 6.15 40.00 15.000 1.231 25 0.0000 0.00 93 0.30 11.50 13.36 13.36
Layer 2 8.65 11.65 3.00 3.00 47.650 22.650 0.684 5 0.0303 0.85 52.87 33 0.45 52.87
Layer 3 11.65 20.00 8.35 8.35 49.150 24.150 0.622 16 0.0000 0.00 77.5 0.30 20.60 10.45 10.45
Layer 4 2.50 20.00 20.00 0.00 1.23 40.00 15.00 0.00 57.500 32.500 0.395 25 0.0000 0.00 200 0.30 11.50 0.00 0.00 0.98 1.00 75.00
Layer 5 20.00 20.00 0.00 0.00 57.500 32.500 0.395 25 0.0000 0.00 200 0.30 11.50 0.00 0.00
Layer 6 20.00 20.00 0.00 0.00 57.500 32.500 0.395 25 0.0000 0.00 200 0.30 11.50 0.00 0.00
Layer 7 20.00 20.00 0.00 0.00 57.500 32.500 0.395 25 0.0000 0.00 200 0.30 11.50 0.00 0.00
Layer 1 3.00 8.65 5.65 5.65 40.00 15.000 1.240 25 0.0000 0.00 93 0.30 11.50 12.52 12.52
Layer 2 8.65 11.65 3.00 3.00 47.150 22.150 0.712 5 0.0303 0.85 55.03 33 0.45 55.03
Layer 3 11.65 20.00 8.35 8.35 48.650 23.650 0.646 18 0.0000 0.00 82.5 0.30 17.90 9.61 9.61
Layer 4 3.00 20.00 20.00 0.00 1.24 40.00 15.00 0.00 57.000 32.000 0.408 25 0.0000 0.00 200 0.30 11.50 0.00 0.00 0.97 1.00 75.00
Layer 5 20.00 20.00 0.00 0.00 57.000 32.000 0.408 25 0.0000 0.00 200 0.30 11.50 0.00 0.00
Layer 6 20.00 20.00 0.00 0.00 57.000 32.000 0.408 25 0.0000 0.00 200 0.30 11.50 0.00 0.00
Layer 7 20.00 20.00 0.00 0.00 57.000 32.000 0.408 25 0.0000 0.00 200 0.30 11.50 0.00 0.00
Layer 1 3.50 8.65 5.15 5.15 40.00 15.000 1.242 25 0.0000 0.00 93 0.30 11.50 11.58 11.58
Layer 2 8.65 11.65 3.00 3.00 46.650 21.650 0.738 5 0.0303 0.85 57.01 33 0.45 57.01
Layer 3 11.65 20.00 8.35 8.35 48.150 23.150 0.669 20 0.0000 0.00 87.5 0.30 16.00 9.05 9.05
Layer 4 3.50 20.00 20.00 0.00 1.24 40.00 15.00 0.00 56.500 31.500 0.419 25 0.0000 0.00 200 0.30 11.50 0.00 0.00 0.97 1.00 75.00
Layer 5 20.00 20.00 0.00 0.00 56.500 31.500 0.419 25 0.0000 0.00 200 0.30 11.50 0.00 0.00
Layer 6 20.00 20.00 0.00 0.00 56.500 31.500 0.419 25 0.0000 0.00 200 0.30 11.50 0.00 0.00
Layer 7 20.00 20.00 0.00 0.00 56.500 31.500 0.419 25 0.0000 0.00 200 0.30 11.50 0.00 0.00
83 of 84
Geotechnical Investigations for Standard Penetration Test and Plate Load Test at Bharatpur. SR-690_22-23
Settlement in Non-
Dispersed Breadth
Height of layer(m)
Elastic Settlement
Geological Factor
Dispersed Length
Depth below FGL
Settlement (mm)
Average N-Value
Total Settlement
Depth (kg/Cm2)
Modulus of Soil
Layer Thickness
Poission's Ratio
Corrected Total
level (Kg/Cm2)
Rigidity Factor
Mvc (Cm /Kg)
Cohesive Soil
Depth Factor
Settlement
(Kg/Cm )
Breadth
Si (mm)
2
Length
(mm)
(mm)
(mm)
Layer
2
From
(m)
(m)
(m)
(m)
(m)
(m)
(m)
(l )
To
Si
Layer 1 4.00 8.65 4.65 4.65 40.00 15.000 1.246 25 0.0000 0.00 93 0.30 11.50 10.63 10.63
Layer 2 8.65 11.65 3.00 3.00 46.150 21.150 0.766 5 0.0303 0.85 59.21 33 0.45 59.21
Layer 3 11.65 20.00 8.35 8.35 47.650 22.650 0.693 22 0.0000 0.00 84 0.30 13.90 8.31 8.31
Layer 4 4.00 20.00 20.00 0.00 1.25 40.00 15.00 0.00 56.000 31.000 0.431 25 0.0000 0.00 200 0.30 11.50 0.00 0.00 0.96 1.00 75.00
Layer 5 20.00 20.00 0.00 0.00 56.000 31.000 0.431 25 0.0000 0.00 200 0.30 11.50 0.00 0.00
Layer 6 20.00 20.00 0.00 0.00 56.000 31.000 0.431 25 0.0000 0.00 200 0.30 11.50 0.00 0.00
Layer 7 20.00 20.00 0.00 0.00 56.000 31.000 0.431 25 0.0000 0.00 200 0.30 11.50 0.00 0.00
Layer 1 4.50 8.65 4.15 4.15 40.00 15.000 1.258 25 0.0000 0.00 93 0.30 11.50 9.69 9.69
Layer 2 8.65 11.65 3.00 3.00 45.650 20.650 0.801 5 0.0303 0.85 61.89 33 0.45 61.89
Layer 3 11.65 20.00 8.35 8.35 47.150 22.150 0.723 26 0.0000 0.00 96 0.30 11.10 7.05 7.05
Layer 4 4.50 20.00 20.00 0.00 1.26 40.00 15.00 0.00 55.500 30.500 0.446 25 0.0000 0.00 200 0.30 11.50 0.00 0.00 0.95 1.00 75.00
Layer 5 20.00 20.00 0.00 0.00 55.500 30.500 0.446 25 0.0000 0.00 200 0.30 11.50 0.00 0.00
Layer 6 20.00 20.00 0.00 0.00 55.500 30.500 0.446 25 0.0000 0.00 200 0.30 11.50 0.00 0.00
Layer 7 20.00 20.00 0.00 0.00 55.500 30.500 0.446 25 0.0000 0.00 200 0.30 11.50 0.00 0.00
Layer 1 5.00 8.65 3.65 3.65 40.00 15.000 1.272 25 0.0000 0.00 100 0.30 11.50 8.72 8.72
Layer 2 8.65 11.65 3.00 3.00 45.150 20.150 0.839 5 0.0303 0.85 64.82 33 0.45 64.82
Layer 3 11.65 20.00 8.35 8.35 46.650 21.650 0.756 35 0.0000 0.00 125 0.30 8.30 5.62 5.62
Layer 4 5.00 20.00 20.00 0.00 1.27 40.00 15.00 0.00 55.000 30.000 0.463 25 0.0000 0.00 200 0.30 11.50 0.00 0.00 0.95 1.00 75.00
Layer 5 20.00 20.00 0.00 0.00 55.000 30.000 0.463 25 0.0000 0.00 200 0.30 11.50 0.00 0.00
Layer 6 20.00 20.00 0.00 0.00 55.000 30.000 0.463 25 0.0000 0.00 200 0.30 11.50 0.00 0.00
Layer 7 20.00 20.00 0.00 0.00 55.000 30.000 0.463 25 0.0000 0.00 200 0.30 11.50 0.00 0.00
84 of 84