You are on page 1of 3

NEAT WIND INDUSTRIES

INPROCESS INSPECTION REPORT


Part Name :- BASE AND TOP STRUCTRAL ASSMBLY Cust. Name :- REPLUS ENGITECH PVT. LTD. SHIFT : GEN
Drawing No:-REPL/EM/ECD/SEZ/002/003 Report No:-REPL/EM/ECD/SEZ-00R1 Date :- 12/12/22
All diamenstion are in mm as per EN ISO13920 in C class .
Observations
Sr. No. REQ.DIM. TOL.
1 2 3 Remark

1 Outside frame(2438x3141x11582) + / - 04 mm 2439x3142x11583 ok


2 frame inside(2274x2315x2841) + / - 04 mm (2275x2317x2843) ok
3 Total ht. 3141 + / - 04 mm 3142/44 ok
4 Corner block 178x162x118 STD 178x162x118 ok
5 Vertical piller 2114 + / - 04 mm 2115/16 ok
6 Top leghth 11582 + / - 04 mm 11584 ok
7 Total width top 2274 + / - 04 mm 2276/78 ok

Note :-All dimension found ok as per drg .

Result: Accepted

* Visual Check For - Chamfers, Chattermarks, Unclean, Blowholes, Gascutmarks, Burrs, Damages.

checked By :-Chavan Arvind


Sign & Date :- 12.12.22

Format No:- C/QA/pr/01 Rev.No.01


Neat Wind Industries
Incoming Inspection Report
Customer Name: Supplier Name:
Item Name: Part Rev. No: Lot Qty:
Part Name: Lot Size:

Sr No Characteristics Specification Instrument Used Sample Obervation

1 2 3
Date:
es Report No:
t Sample Size:
Row Material Details
Material Grade: Heat code:

mple Obervation Remark

4 5 6