Case Study About Wear Out Blades of Impeller ESP Fan 1670893154
Case Study About Wear Out Blades of Impeller ESP Fan 1670893154
EQUIPMENT DETAILS
Eq. Name: ESP FAN
Power: 450 kw
DE Fan Br.: 22228 C3
NDE Fam Br.: 22228 C3
Speed: VFD ( max. 680 rpm)
No. of Blades: 12 Blades
Type of Impeller: Double Row Blades
INTRODUCTION
The fan essentially comprises a radial fan impeller ( mounted on shaft supported in antifriction
bearing) and the housing designed as guide unit. The impeller and the shaft are dynamically
balanced.
The housing of welded steel plate design is split so that the impeller can be mounted and
dismantled without any problem.
Observation
Cooler ESP is a critical process fan in the kiln area. A continuous monitoring of such fan is
required to understand the trend of the machine and to predict the possible defect.
When running with high speed appeared impacts in time wave
1
In previous shutdown Dec. 2021. Inspect the fan bearings condition where not observed
rotational looseness and with offline inspection of impeller was observed regular worn out of
blades.
2
Worn out in Blades DE side Row
In this planned stoppage decided to replace the impeller with new one in stock.
3
On 26.09.2022, After complete fixed new impeller taking trial with 460 rpm where the
vibration is good but must be run the fan with full speed to make sure its condition.
4
Spectrum Horizontal NDE Fan Bearing
5
Time wave Vertical NDE Fan Bearing